Records from 2016 to 2025. Most recent: inspection, 28 August 2025.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 13.3 ft × 6.0 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBBINS BOAT BUILDERS INC · CAMBRIDGE, MD, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portNORTH BEACH, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 22 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
28 August 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8230088
9 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8109080
23 August 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7987528
23 August 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7780121
29 March 2023
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7659223
26 May 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7394761
24 August 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7295503
18 March 2021
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7188634
26 August 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7043262
20 August 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6783993
19 March 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6651915
21 August 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6517108
7 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6232878
25 April 2017
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6132292
21 March 2017
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6121099
23 August 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5980269
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 29 March 2023
Resolved
03112 - Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. The starboard through hull ball valve for the sink would not close.
46 CFR 179.350(c)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2023
Resolution: Received photographic evidence from the vessel owner showing repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2023
Resolved
13199 - Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The piping from the hydraulic oil tank was leaking and needs to be replaced.
46 CFR 182.100
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2023
Resolution: Received photographic evidence from the vessel owner showing repairs.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 24 August 2021
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Vessel collision bulkhead had silicone caulk on stbd side and FRP tabbing was de-laminated on port side.
46 CFR 179.320(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2021
Resolution: Owner repaired tabbing on collision bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 August 2021
Resolved
The minimum number of portable fire extinguishers required on vessel must not be fewer than the minimum number required by Table 181.500(b). Vessel was missing (01) 40-B:C extinguisher for machinery space.
46 CFR 181.500(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2021
Resolution: Owner purchased new extinguisher to meet requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 August 2021
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart in such a manner to avoid chafing and other damage. Wiring for anchor windlass in #2 space was laying in bilge.
46 CFR 183.340(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2021
Resolution: Owner installed supports for electrical wiring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 August 2020
Resolved
At the time of the inspection the main propulsion engine would not start.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 September 2020
Resolution: Verified proper operation of vessel engine. Tested Fireboy shutdown and conducted sea trial.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 May 2017
Resolved
Replace expired battery with approved battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 7 August 2017
Resolution: Replaced battery.
Lifesaving › Lifebuoys › Serviceable
Issued 16 May 2017
Resolved
Repair/replace wasted grab line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2017
Resolved 9 August 2017
Resolution: O/O replaced entire life ring buoy.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 May 2017
Resolved
1 Adult PFD unserviceable. Replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2017
Resolved 9 August 2017
Resolution: O/O purchased new adult PFD.