Records from 1988 to 2008. Most recent: inspection, 17 July 2008.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAKECRAFT WELDING INCORPO · PORT CLINTON OH, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portCLEVELAND, OH
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
17 July 2008
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3270340
20 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3001372
28 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2762260
10 August 2005
COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2455655
20 May 2005
Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2363014
10 June 2004
Annual Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2094033
26 June 2003
Annual Inspection · Administrative Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1828091
11 July 2002
Deficiency Check · Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1645287
7 November 2001
Deficiency Check · Annual Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1618984
30 June 2000
COI Inspection · Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1450554
30 June 1999
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1087251
15 June 1998
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1453500
23 May 1997
COI Inspection · Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1404385
15 May 1996
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1385717
19 May 1995
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1169659
9 May 1994
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 852930
3 June 1993
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1135522
24 March 1993
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 834784
29 May 1992
Hull Examination · Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 955640
18 November 1991
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 675355
4 September 1991
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1373709
1 August 1991
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1246941
10 July 1991
Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1246965
22 April 1991
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 919456
6 February 1991
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1260674
17 May 1989
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1200777
27 July 1988
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1344139
2 June 1988
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1198086
Operations/Management › Drills/Instruction
Issued 26 June 2003
Resolved
Provide an acceptable means of recovering someone from the water. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 18 July 2003
Resolution: Cleared
Lifesaving › Lifejacket/PFD (General)
Issued 11 July 2002
Resolved
Label child's lifejacket storage compartment. LEGACY COMPONENT DESC: Storage
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 18 July 2002
Resolution: Witnessed correction.
Documentation › Certificates/Documents
Issued 11 July 2002
Resolved
Keep original COD on board. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 18 July 2002
Resolution: Witnessed correction.
Operations/Management › Pollution
Issued 11 July 2002
Resolved
Install new oil discharge placard at operating station. LEGACY COMPONENT DESC: Control of Discharge of Oil
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 18 July 2002
Resolution: Witnessed correction.
Communications › Alarms/Indicators
Issued 11 July 2002
Resolved
Replace audible bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 18 July 2002
Resolution: Witnessed correction.
Electrical › Electrical Distribution System (service)
Issued 7 November 2001
Resolved
Remove all extraneous wiring throughout boat. Eliminate screw type wire caps. Clean up all wiring and secure in bundles, where possible, to overhead. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Engineering › Bilge Water Management System
Issued 7 November 2001
Resolved
Prove proper operation of bilge high level alarms and pumps. LEGACY COMPONENT DESC: Interface Detector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Stability › Weathertight Integrity
Issued 7 November 2001
Resolved
Crop & renew engine room hatch gasket combing. LEGACY COMPONENT DESC: Engine room hatch
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Stability › Watertight Integrity
Issued 7 November 2001
Resolved
Remove and/or cap off overboard pipe originating at starboard aft engine room hatch combing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2001
Resolved
Repair rotten upper slat on starboard rail (cut/remove to good wood). LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Stability › Weathertight Integrity
Issued 7 November 2001
Resolved
Re-gasket deck hatches. LEGACY COMPONENT DESC: Gaskets
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2001
Resolved
Crop & renew port (#2 from aft) stanchion. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2001
Resolved
Remove exposed screw port uppermost rail midship. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 7 November 2001
Resolved
Replace both aft wood slat doors with stable rail/panel material suitable to withstand 200 lb point load. LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Construction/Loadline › Hull
Issued 7 November 2001
Resolved
Gauge, crop, and renew aft gunwale, transom (turn of the deck), and lower port aft stanchion to good metal. LEGACY COMPONENT DESC: Sheerstrake
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 November 2001
Resolved
Have all fire extinguishers and fixed fire fighting systems serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 7 November 2001
Resolved
Provide means for securing forward life jacket container. LEGACY COMPONENT DESC: Storage
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Electrical › Lighting (service)
Issued 7 November 2001
Resolved
Secure stern light. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Fire Fighting
Issued 30 June 2000
Resolved
MOUNT PORTABLE FIRE EXT. IN APPROPRIATE BRACKETS AND LOCATIONS.
Condition: Unknown
Due 5 July 2000
Resolved 6 July 2000
Construction/Loadline
Issued 30 June 2000
Resolved
REPLACE BOTTOM PLATING DUE TO EXCESSIVE WEAR IN SEVERAL AREAS.
Condition: Unknown
Due 30 June 2000
Resolved 4 December 2000
Fire Fighting
Issued 30 June 2000
Resolved
SERVICE FIXED HALON SYSTEM.
Condition: Unknown
Due 5 July 2000
Resolved 6 July 2000
Construction/Loadline
Issued 23 May 1997
Resolved
AFTERMOST STBD STANCHION WHICH SUPPORTS OVERHEAD ROOF AND SUPERSTRUCTURE WAS BENT. CAUSE IS UNKNOWN, BUT IT IS SUSPECTED THAT THE DAMAGE OCCURRED WHILE REMOVING OR RETURNING THE BOAT FROM THE WATER FOR DRYDOCKING AT MARINA.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Fire Fighting
Issued 22 April 1991
Resolved
PROVIDE AN ADDITIONAL TWO (2) B-II FIRE EXTINGUISHERS IAW [name withheld] OF 14SEP87 FOR A TOTAL OF FOUR OR INSTALL A POWER DRIVEN FIRE PUMP AND HOSE IAW 46 CFR 181.15 TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR NOT LATER THAN 10 JULY 1991.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991