Records from 2016 to 2026. Most recent: inspection, 24 February 2026.
Inspection history · 27
24 February 2026
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8296299
22 May 2025
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8127532
12 March 2025
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8092793
28 February 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8086532
16 January 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8064802
3 September 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7995581
14 June 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7918214
29 November 2023
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7724790
18 January 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7623211
15 December 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7610145
19 August 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7537644
28 March 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7420284
28 March 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7459005
2 February 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7385019
9 September 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7308617
22 February 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7144006
7 January 2021
Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7121028
25 February 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6915256
30 April 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6610583
4 January 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6599927
5 February 2018
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6332694
28 February 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6082019
4 January 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065105
29 November 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6049530
27 November 2016
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6048491
27 November 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6048877
23 February 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5802872
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 28 February 2025
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant OCMI. No anchor on vessel. Provide anchor prior to departing San Diego.
46 CFR 121.300
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2025
Resolved 12 March 2025
Resolution: Anchor provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 February 2025
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. No name on stern of vessel. Provide vessel name on stern of vessel.
46 CFR 67.123 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2025
Resolved 21 March 2025
Resolution: Name and home port properly marked on transom.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 February 2025
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Drills not conducted at inspection. Conduct drills with USCG when vessel returns to homeport LA/LB.
46 CFR 115.808
46 CFR 115.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 12 March 2025
Resolution: Drills conducted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 January 2025
Resolved
Submit repair proposal for cracks along transverse frames in both aft steering platforms.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 February 2025
Resolution: Verified Repairs
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 January 2025
Resolved
Submit repair proposal for areas already identified as requiring crop and renewing.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 February 2025
Resolution: Verified Repairs
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 January 2025
Resolved
Submit repair proposal for the starboard side main void area of pitting both port and starboard side of the keel
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 February 2025
Resolution: Verified Repairs
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 January 2025
Resolved
Submit repair proposal for the port and starboard pitting found in the engine room.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 February 2025
Resolution: Verified Repairs
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 November 2023
Resolved
Guards for exposed hazards. Port engineroom deck plate cracked and wobbly.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2023
Resolution: MIs witnessed welded deck plate with added stiffener. Cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 29 November 2023
Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. Fire control plan shows incorrect fire extinguisher sizes and self-closing doors for the machinery space while that are not installed or required (vestibule has verticle trunk with water tight hatch).
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2023
Resolution: MIs witnessed updated Fire Control Plan. Also stamped plan.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 November 2023
Resolved
Condition of hull. Port transom padpadeye above stabilizer is pulled from deck edge. Operator states was using to hang port stabilizer, which activated and damaged padeye.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 May 2025
Resolution: MI inspected proper repair during ISE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2023
Resolved
Operation of machinery including generators. Port generator exhaust leaks through pipe lagging at flange.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 30 January 2024
Resolution: Operator stated exhaust repairs completed. Cleared by MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 November 2023
Resolved
Inspection of interior of hull. Void (2nd hatch on stbd bow) inboard, side chord weld cracked appx center space at chest level(already labeled with black marker). No adjacent cracking noted, monitor through next drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 14 December 2023
Resolution: MIs witnessed stbd void, crack has been welded (welder on site).
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 November 2023
Resolved
A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or a standard specified by commandant. MI found all six hydrostatic releases for IBA’s did not have expiration dates marked. Vessel corrected during inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 29 November 2023
Resolution: Corrected during inspection.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 November 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. All of vessel’s testing strips are expired. 46 CFR 4.06-15
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2023
Resolution: MIs witnessed updated alcohol swabs onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 November 2023
Resolved
A vessel on an oceans, coastwise, or limited coastwise, route must carry 6 hand red flare distress signals and six hand orange smoke distress signals. MI discovered 8 of 12 expired flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 November 2023
Resolution: Vessel replaced flares during the inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 November 2023
Resolved
A vessel must carry either a first-aid kit or acceptable equivalent. MI discovered vessel did not have a first aid kit onboard. Vessel replaced during inspection.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 29 November 2023
Resolution: Vessel replaced during inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 November 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights, one of the these located at the operating station and the other at the access to the propulsion machinery space. Vessel did not have any portable lights on board. Replaced during inspection.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 29 November 2023
Resolution: Replaced during inspection.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 29 November 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number allowed on an upper deck must be indicated b a durable marking of at least 25 mm (1 Inch) numbers and letters at the entranceway to that deck. Top deck is not marked with max number of passengers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2023
Resolution: MIs witnessed upper deck placarded for 128 passengers at updder deck ladder well and on upper deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 November 2023
Resolved
Cable and wire must be installed with metal support spaced not more than 24 inches apart. During inspection, found emergency fuel pull cables hanging from wire run, spaced more than 24 inches apart.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2023
Resolution: MIs witnessed fuel pull cables not interfere with electric panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2022
Resolved
A vessel must be provided with main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. The vessel experienced a loss of steering while U/W. Vessel must prove proper operation of the steering equipment prior to movement.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2022
Resolved 28 March 2022
Resolution: Installed 02 new hydraulic flexible hoses on STBD steering ram.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 7 January 2021
Resolved
Found 2 inch crack in bulkhead weld for the exhaust in stbd side lazarette.Provide repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 January 2021
Resolution: Satisfactory repaired, NDT via dye penetrant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment... Vessels installed bilge system could not initially take suction from the forward ballast compartment in the starboard hull.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2020
Resolved 25 February 2020
Resolution: Vessels crew was able to quickly troubleshoot and resolve a stuck check valve within minutes of discovering the problem. Crew able to prove proper operation of the system to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 April 2019
Resolved
Each item of survival craft equipment must be efficient for the purpose of its use. Provide serviceable water light for life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 6 May 2019
Resolution: A new water light was installed.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 28 February 2017
Resolved
Mark childsize lifejackets with vessel name.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Childsize lifejackets marked with vessel name.
Lifesaving › Lifefloat › Painter
Issued 28 February 2017
Resolved
Renew worn painters on lifefloats and lifefloat floating waterlights as ID'd by MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Painters and taglines renewed with compliant line.
Lifesaving › Lifefloat › Float Free
Issued 28 February 2017
Resolved
Remove heavy weather holdbacks from lifefloat stowage structures to ensure float-free operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Holdback bars removed from all lifefloats, all sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 February 2017
Resolved
Repair cracked waterproof layer on PFDs as ID'd by MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Affected PFDs repaired with waterproof durable bright orange tape.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 28 February 2017
Resolved
Ensure proper drug and alcohol program consortium is properly reflected in the company's drug and alcohol program policy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Company designated employee representative (DER) updated policy with new consortium information.
Construction/Loadline › Hull › Side Shell
Issued 4 January 2017
Resolved
Repair crack on starboard (outboard) hull at generator exhaust outlet
Action required: 705 - Other - as specified
Resolved 17 January 2017
Resolution: Crack welded to satisfaction of attending Coast Guard Marine Inspector
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 27 November 2016
Resolved
Prove proper operation of port MDE prior to carrying passengers. 46 CFR 119.200(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2016
Resolution: Vsl made necessary repair to hydraulic line. Proved proper operation, all sat.