Records from 1987 to 2016. Most recent: inspection, 21 February 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
21 February 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5819112
7 December 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5776754
30 January 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1997208
30 January 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1997799
30 May 2000
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 278535
7 April 1999
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 426923
12 May 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 415692
13 April 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 414705
21 May 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 391474
27 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 388401
31 October 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 699145
26 September 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 462090
22 May 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 378704
2 January 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 386427
17 June 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 367749
17 June 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1023835
27 December 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 334463
10 July 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 483741
17 December 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 327348
14 December 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 320064
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 7 December 2015
Resolved
Code 2199: Each incinerator shall be approved by the admin taking into account the standards specifications for shipboard incinerators. Incinerator walls are to be protected with insulated fire bricks or refractory. Vessel incinerator refractory materials deteriorating both on the door and within the incinerator. MARPOL Annex VI/Reg 16.2(a)
Action required: 705 - Other - as specified
Due 6 January 2016
Resolved 24 February 2016
Resolution: Received class report attesting to repairs.
Accommodation/Occupational Safety
Issued 7 April 1999
Resolved
Plumbing for toilet in hospital space was not connected. ILO 147 _x001C_ Correct prior to next U.S. port call.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Accommodation/Occupational Safety
Issued 7 April 1999
Resolved
Overboard discharge valve for Marine Sanitation Device was not properly secured. 33 CFR 159.7
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Unknown
Issued 13 April 1998
Resolved
LIFEBOAT FALLS DUE FOR REQUIRED MAINTENCE, END FOR END.
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Unknown
Issued 13 April 1998
Resolved
INSTALL LIGHT BULB, GLOBE, AND GUARD FOR EMERGENCY LIGHT ESCAPE FROM SHAFT ALLEY.
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Fire Fighting
Issued 22 May 1995
Resolved
FIRE MAIN IS CRACKED AT AFT LINE DRAIN.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Documentation
Issued 14 December 1987
Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OTP REQ BY 33 CFR 155.720 WERE INCOMPL-ETE. THE OTP DID NOT CONTAIN A LIST OF EACH PRODUCT TRANSFERRED, PROCEDUR-ES FOR:EMPTYING DISCHARGE CONTAINENT,TOPPING OFF TANKS,REPORTING OIL DISCH-ARGES IN THE WATER,TENDING MOORING LINES & LOCATION OF THE SHUTOFF VALVE.
Condition: Unknown
Due 14 December 1987
Resolved 14 December 1987