MAURY USCG vessel records
← All vessels

UDALLS COVE

UDALLS COVE is a 1987 freight barge. The Coast Guard has recorded 19 inspections since 1987, most recently in December 1998, along with 20 deficiencies.

Records from 1987 to 1998. Most recent: inspection, 4 December 1998.

Built
1987
Last inspected
4 December 1998
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 4 December 1998
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (1987–1998)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

293151
Flag
UNITED STATES
Maury page id
psix-293151

Documentation record

Tonnage as PSIX records it5736 - Regulatory (Subpart C or D), Gross Ton
5533 - Regulatory (Subpart C or D), Net Ton
13485 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

4 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 61333
23 December 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140053
13 January 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261316
4 September 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937051
4 September 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938337
22 August 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245755
31 October 1990 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234401
19 June 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922896
29 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909761
1 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905330
1 May 1990 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226479
6 October 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039021
20 September 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900632
7 September 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338548
16 November 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347806
11 January 1988 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1025400
30 December 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1315263
6 November 1987 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023801
4 September 1987 Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1322990

Deficiency record · 20

Electrical
Issued 22 August 1991 Resolved
DEMONSTRATE LOW LUB OIL PRESSURE SHUT DOWN ON #1 GENERATOR.
Condition: Unknown
Due 4 November 1991
Resolved 4 November 1991
Electrical
Issued 31 October 1990 Resolved
PROVIDE OPERATIONAL TEST OF AUXILIARY GENERATOR.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Fire Fighting
Issued 31 October 1990 Resolved
PROVE OPERATIONAL CONTROL OF VALVE CONTROL PNEUMATIC HEAD FOR AFT FIXED CO2SYSTEM TO THE SATISFACTORY OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Construction/Loadline
Issued 1 May 1990 Resolved
PROVIDE PROPOSAL FOR PERMANENT REPAIR OF STRUCTURAL FAILURE OF WB1S & WB1P WITH PROPER APPROVAL TO THE [name withheld] 30 MAY 90.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 1 May 1990 Resolved
COMPLETE COAST GUARD APPROVED PERMANENT REPAIR IN WB1S AND WB1P NO LATER THAN 30 SEP 90.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Fire Fighting
Issued 7 September 1989 Resolved
REPLACE OR RENEW THE COMBINATION MANUAL/ELECTRICAL-ACTUATION HEADS ON THE FIXED FIRE EXTINGUISHING SYSTEM IN THE AFT SECTION OF THE VESSEL, GENERATOR ROOM
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Electrical
Issued 7 September 1989 Resolved
REPLACE OR REPAIR THE AUDIO ALARM ON THE AUXILIARY GENERATOR ALARM PANEL.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Accommodation/Occupational Safety
Issued 7 September 1989 Resolved
REPLACE ALL SNAP SHACKLES ON ALL LIFELINE PASSAGE/ACCESS CHAINS ABOARD THE VESSEL. ALL WERE EITHER BROKEN OR RUSTED TO THE POINT OF INOPERATION.
Condition: Unknown
Due 7 September 1989
Resolved 7 September 1989
Construction/Loadline
Issued 6 November 1987 Resolved
GOUGE OUT AND REWELD CRACKED WELD IN SIDE SHELL SEAM AT STARBOARD QUARTER BETWEEN THE 2ND AND 3ND CORNER GUSSET FROM THE TOP.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Construction/Loadline
Issued 6 November 1987 Resolved
MAKE SATISFACTORY REPAIRS TO DAMAGES TO SIDE SHELL AND ASSOCIATED INTERNALSIN WAY OF DAMAGED AREA ON STARBOARD BOW/SIDE/AND QUARTER.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Electrical
Issued 4 September 1987 Resolved
SONIC LEVEL PROBES INSTALLED IN TANKS ARE TO BE INTRINSICALLY SAFE AND UL, FM OR CSA APPROVED.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Unknown
Issued 4 September 1987 Resolved
CONFIRM THE MATERIALS USED IN THE CONSTRUCTION OF SLUDGE DUMP VALVES.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Unknown
Issued 4 September 1987 Resolved
SAFETY CONTROLS ON THE ELECTRIC HEATER ARE TO BE OF THE MANUALLY RESETTABLETYPE IN ACCORDANCE WITH 46 CFR 111.87-3 (C).
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Electrical
Issued 4 September 1987 Resolved
EACH BATTERY CHARGER IS TO BEAR THE UL MARINE LISTING MARK. OTHERWISE, A LINE BY LINE COMPARISON TO UL 1236 INCLUDING THE MARINE SUPPLEMENT IS TO BESUBMITTED. THE CHARGERS ARE TO BE AT LEAST DRIP-PROOF.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Deck/Cargo
Issued 4 September 1987 Resolved
IN ACCORDANCE WITH ABS LTR DTD 13 FEB 87, DWG. M244-H01, ITEMS 4 AND 5, PROVIDE EVIDENCE THAT THE DISCH HOSE (INCL END FTNGS) HAVE BEEN ACCEPTED BYUSCG G-MTH. THE HYDRAULIC ACCUMULATOR SHALL BE ACCEPTED AND APPROVED BY THEUSCG AS REQUIRED BY CFR 58,30-25(C).
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Documentation
Issued 4 September 1987 Resolved
OBTAIN AND PLACE ONBOARD A COAST GUARD CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Documentation
Issued 4 September 1987 Resolved
OBTAIN AND PLACE ONBOARD A CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Deck/Cargo
Issued 4 September 1987 Resolved
IN ACCORDANCE WITH ABS/J.B. CO. LTR DTD 5 MAR 87, PROVIDE THE REQUIRED BURST TEST REPORTS.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Electrical
Issued 4 September 1987 Resolved
THE RECEPTACLE FOR THE TUG/BARGE COMBINATION SHALL BE OF THE MALE AND REVERSE SERVICE TYPE IN ACCORDANCE WITH 46 CFR 111.79-9 (B).
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Electrical
Issued 4 September 1987 Resolved
ALL ELECT. EQUIP. INSTALLED ON DK WITHIN 3 MTRS. OF ANY TANK OUTLET IS TO BE EITHER INTRINSICALLY SAFE, OR EXPLOSION PROOF. ANY ELECT. EQUIP. IN- STALLED WITHIN THE TANK IS TO BE OF THE INTRINSICALLY SAFE TYPE. EQUIP MUSTBE UL,FM OR CSA APPROVED FOR USE IN CLASS 1,DIV. 1,GROUP D LOCATIONS.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.