Inspection history · 33
12 August 2026
In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8462865
13 July 2025
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8347135
12 July 2025
Damage Survey · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8186617
25 June 2025
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8166818
24 June 2025
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8167592
16 October 2024
Drydock Exam · Administrative Inspection · Damage Survey · Annual Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8020211
23 July 2024
Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7996478
22 July 2024
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7966088
5 June 2024
Deficiency Check · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7926481
8 June 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710737
11 January 2023
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7620093
21 July 2022
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7512385
21 July 2022
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7890235
2 June 2022
Security Plan Amendment Review - ASP · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7460216
1 June 2022
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7465716
27 April 2022
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7444229
27 August 2020
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7043849
1 May 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6946993
29 October 2019
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6848955
21 October 2019
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6841146
4 October 2019
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6829905
25 March 2019
Deficiency Check · Examination of Repairs · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6648835
11 March 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6640510
11 December 2018
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6595776
6 December 2018
Deadweight Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6593741
29 August 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6526938
17 April 2018
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6393679
1 December 2017
Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6316572
27 September 2017
Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6275846
10 May 2017
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6143144
24 March 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6111172
10 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6099724
10 March 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5831590
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 July 2025
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. The port main engine gear box experienced knocking and requires replacement or rebuild. A Marine Inspector must attend to witness completed repairs and conduct sea trials prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2026
Resolved 27 May 2026
Resolution: Conducted sea trials of brand new engines and gear box. All sat. Gearbox def is clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. The port main engine experienced a high jacket water temperature suspected to have been caused by a damaged heat exchanger. A Marine Inspector must attend to witness repairs and conduct sea trials prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2025
Resolution: Cracked cylinder liner replaced. Sea trials sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2025
Resolved
Each individual bilge suction must be fitted with a suitable strainer. Port #4 void strainer not mounted. 46CFR119.510, 46CFR56-50.50(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 May 2025
Resolved
The fire pump must be capable of delivering a single hose stream at a pitot tube pressure of 50 psi. Port pump pressure gauge inaccurate. 46CFR118.300(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 May 2025
Resolved
The arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for protection against fire. Port engine room hatch missing structural fire protection insulation. 46CFR116.100(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 19 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 21 May 2025
Resolved
The emergency lighting must automatically actuate upon failure of the main lighting system. Upper deck emergency lighting inoperable. 46CFR120.432(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 May 2025
Resolved
A crew work space must be with suitable equipment to provide for the safe operation of the vessel and the protection of the crew. Starboard engine room grates at base of ladder are inadequately supported. 46CFR116.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2025
Resolved 3 June 2025
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 June 2024
Resolved
Make both aft engine room to laz bulkhead vapor/ smoke tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 2 July 2024
Resolution: Rectified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2024
Resolved
Cap off unused overboard piping in the port engine room inboard side and in the starboard laz inboard side
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 2 July 2024
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2024
Resolved
Replace Starboard side main deck leaking fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2024
Resolved 12 June 2024
Resolution: Replace both fire hoses.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2024
Resolved
Replace both expired life ring buoy light batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 2 July 2024
Resolution: Rectified
10 - Safety of Navigation › N/A - No Subsystem › Compass correction log
Issued 5 June 2024
Resolved
Provide and post a compass deviation card in wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 2 July 2024
Resolution: Rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2024
Resolved
Reinstall broken and missing grounding straps n both main engine exhaust systems.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 2 July 2024
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 June 2024
Resolved
Post schematic diagram of the CO2 system in the storage location for both engine rooms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 2 July 2024
Resolution: Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2024
Resolved
Remark the vessel’s name on life rings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 2 July 2024
Resolution: Rectified
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2023
Resolved
33 CFR 104.120:Compliance Documentation.
For vessels operating under a Coast Guard-approved Alternative Security Program as provided in § 104.140, a copy of the Alternative Security Program the vessel is using, including a vessel specific security assessment report generated under the Alternative Security Program, as specified in § 101.120(b)(3) of this subchapter, and a letter signed by the vessel owner or operator, stating which Alternative Security Program the vessel is using and certifying that the vessel is in full compliance with that program. Vessel missing one or more required documents pertaining to security.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2024
Resolved 21 May 2025
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 June 2023
Resolved
46 CFR 171.080: Damage stability standards.
(a) Calculations. Each vessel with Type I or Type II subdivision must be shown by design calculations to meet the survival conditions in paragraph (e), (f), or (g) of this section in each condition of loading and operation assuming the extent and character of damage specified in paragraph (b) of this section. Update stability calculations to account for weight changes/shift and sail area modification.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2024
Resolved 15 June 2024
Resolution: Stability letter issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 January 2023
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Both engine rooms flooded due to the sea strainers freezing and breaking the hose fittings off. Both MDEs, SSDG's, switchboards, all wiring, and pumps have been compromised. Make all repairs to the satisfaction of the attending Marine Inspector prior to carrying passengers. 46 CFR 119.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 July 2022
Resolved
EXCESSIVE WATER WAS FOUND IN THE STARBOARD HULL STEERING GEAR VOID. MAKE PERMANENT REPAIRS TO STARBOARD AFT STEERING VOID HATCH SEAL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 22 August 2022
Resolution: Operator replaced the recently damaged hatch gasket with a brand new one and hose tested - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 July 2022
Resolved
PROVIDE INSPECTION REPORT OF INTERNAL EXAMINATION OF STARBOARD HULL AND IDENTIFY LOCATION OF WATER INGRESS THAT CAUSED FLOODING TO SATISFACTION OF USCG MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 22 August 2022
Resolution: Operator discovered the hatch gasket was previously damaged allowing water flow into the void from the flush deck. Operator replaced the gasket with a brand new gasket and hose tested - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 July 2022
Resolved
VISUALLY INSPECT STARBOARD HULL VOID PRIOR TO EACH TRIP AND DOCUMENT INTO SHIP'S LOG BOOK UNTIL PERMANENT REPAIRS ARE MADE TO SATISFACTION OF USCG MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 22 August 2022
Resolution: Operator inspected and logged inspections of the starboard aft steering void until the hatch was repaired - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The port Main Diesel Engine shut down unexpectedly upon further investigation the jacket water coolant drained into the oil sump. Properly repair the port engine to the satisfaction of the attending Marine Inspector prior to carrying passengers. 46 CFR 119.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2022
Resolved
Electrical equipment in a machinery space or other wet location must be dripproof. The 110 vt outlet in the stbd side aft MSD space is not a dripproof fixture. Install proper dripproof electrical fixture for the MSD space 110 vt outlet. 46 CFR 120.210
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2022
Resolved 28 June 2022
Resolution: The owner installed a weather proof 110vt outlet box - all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2022
Resolved
The use of twist on type wire nuts is permitted under the following conditions. The connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration, twist on connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of the circuit. The heat detector wiring over the stbd main diesel engine has exposed wire nuts for wire connectinos. Properly repair the wire connections for the stbd engine room heat detection system. 46 CFR 120.340
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2022
Resolved 28 June 2022
Resolution: Owners mechanic replaced the twist connectors with waterproof pressure connectors and secured wiring - all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect the crew and the vessel from electrical hazards. The electrical cover for the shore power terminal block on the port side of the vessel is loose and not secured. Properly secure the electrical terminal block cover. 46 CFR 120.200
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2022
Resolved 29 June 2022
Resolution: Owners electrician properly secured the electrical cover - all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2022
Resolved
Bilge high level alarms must be provided with a visual and audible alarm at the operating station to indicate a high water level. At the operating station the port bilge high level alarm indicator light is out of commission. Properly repair the port high bilge level alarm indicator light. 46 CFR 119.530
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2022
Resolved 24 June 2022
Resolution: Owner replaced the faulty light - all sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 June 2022
Resolved
Ventilation of the engine room, provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The forward engine room supply fan and duct vent closures are not closing 100%. Properly repair vent closures in the port and starboard engine rooms to ensure the supply vent ducts are 100% closed when closures are activated. 46 CFR 119.465
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2022
Resolved 28 June 2022
Resolution: Owner replaced worn out vent closure springs vents now fully close when activated - all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 October 2019
Resolved
During fixed CO2 system testing, port system released at 43 seconds and starboard system released at 37 seconds. These systems are both equipped with 30 second time delays. Restore system to release within tolerance and demonstrate to the attending CG marine inspector. - 46 CFR 118.410
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2020
Resolved 1 May 2020
Resolution: Cleared upon surrender of COI. See activity 6946993 narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2018
Resolved
Repair Fuel leak on port main engine fwd raycor fuel filter
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2019
Resolution: Filter no longer leaking fuel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 December 2018
Resolved
Provide a horn that produces the required dB and audibility range listed in 33 CFR 86
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2019
Resolution: Horn repaired and sounded.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 December 2018
Resolved
Prove proper operation of port engine room high level bilge alarm
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 March 2019
Resolution: Alarms work.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 December 2018
Resolved
Conduct underway fire and abandon ship drills with CG inspectors attending
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Conducted underway drills, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 December 2018
Resolved
Vessel's passenger count is reduced to 72 adults and 9 children until remaining life jackets are replaced or repaired per NVIC 2-63
Action required: 705 - Other - as specified
Resolved 29 April 2019
Resolution: Vessel has replaced all lifejackets
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 December 2018
Resolved
Fill port engine room fwd bulkhead wire thought bulkhead run to make it smoke tight
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2019
Resolution: Vessel has filled wire run.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 December 2018
Resolved
Repair exhaust raw cooling water leak on starboard main engine
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2019
Resolution: Vessel has completed repairs to the exhaust raw cooling water leak on starboard main engine
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2018
Resolved
Permanently attach life buoy floating water light to life buoy as per 46 CFR 117.70 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2019
Resolution: vessel has Permanently attach life buoy floating water light to life buoy
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 December 2018
Resolved
Get FCC Bridge to Bridge updated with a expiration date
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2019
Resolution: vessel has a current FCC Bridge to Bridge
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2018
Resolved
Provide covers on electrical outlets in both engine rooms
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2019
Resolution: Elec. covers have been installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2018
Resolved
During annual security exercise properly list all participants attending exercise
Action required: 705 - Other - as specified
Due 11 December 2019
Resolved 11 March 2019
Resolution: Vessel has correctly listed all participants attending exercise
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 December 2018
Resolved
Within 1 month temporary mark starboard aft Draft mark and permanently fix within 6 months
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 3 April 2019
Resolution: Vessel has installed draft marks
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 18 April 2018
Resolved
The port engine room fixed CO2 system discharge piping does not have the odorizing unit connected, resulted in an opening in the discharge piping that would immediately release CO2 into the activation area. Replace odorizing unit on discharge piping.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 25 April 2018
Resolution: Odorizer installed.
Operations/Management › Drills/Instruction › Fire
Issued 18 April 2018
Resolved
Records of fire and abandon ship/man overboard drills are not available onboard. Provide documentation of the completion of required drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 December 2018
Resolution: Vessel has been documenting all drills
Lifesaving › Lifebuoys › Serviceable
Issued 18 April 2018
Resolved
Two ring lifebuoys are unservicable. Replace unservicable lifebuoys.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2018
Resolution: Lifebuoys replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 April 2018
Resolved
Floating waterlight on port side upper deck ring buoy contains unapproved battery. Replace with approved battery of appropriate weight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2018
Resolution: battery replaced with approved battery.
Construction/Loadline › Hull › Bottom Plating
Issued 18 April 2018
Resolved
A pit in excess of 1/8" in depth is present in starboard fuel tank space hull plating. Repair hull plating to the satisfaction of the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2018
Resolution: Pit repaired with insert.
Stability › Watertight Integrity › General
Issued 18 April 2018
Resolved
An unprotected bulkhead penetration exists between the port engine room and lazarette. Restore watertight integrity of bulkhead to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2018
Resolution: Penetration sealed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 April 2018
Resolved
Lighting guard on light above sink area in main passenger compartment broken. Replace guard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 April 2018
Resolution: Guard replaced.
Accommodation/Occupational Safety › Potable Water System › General
Issued 18 April 2018
Resolved
Potable water pump and filter housing are both cracked. Repair or replace pump and replace filter housing.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 April 2018
Resolution: Pump and filter housing replaced.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 March 2017
Resolved
Properly repair the port forward engine room supply vent fan damper. Bracket broke off keeping the damper in the closed position.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Maintenance personnel installed a new cable bracket. Tested SAT.
Personnel › Training › Passenger Safety
Issued 11 March 2017
Resolved
Conduct u/w emergency drills in the presence of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 10 May 2017
Resolution: Witnessed satisfactory drills.
Engineering › Bilge Water Management System › Manifold
Issued 11 March 2017
Resolved
Prove proper operation of the emergency bilge cross over. During inspection cross over line was blocked with frozen water. Both the port and stbd bilge systems op tested - SAT.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Test bilge cross over using the port and stbd bilge pumps - All SAT.
Fire Fighting › Remote Fuel Shutoff › General
Issued 11 March 2017
Resolved
Properly secure emergency fuel shut off valve control cable to bracket for the port SSDG. Control cable secured the fuel valve however it is slipping through the support bracket making it unreliable and potential to fail.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Maintenance personnel secured the fuel cable. Tested - SAT.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 11 March 2017
Resolved
Repair or renew x4 Type 1 adult PFD's and x1 child Type 1 PFD. PFD's retro-flective tape is heavily worn and some the vessels name has worn off or has the incorrect name.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Ships crew repaired the life jackets by adding new SOLAS retro tape and placed the vessels name onto the same - All SAT.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 March 2017
Resolved
Properly secure the A60 insulation iwo the port and stbd aft engine room ventilation dampers. The dampers are rubbing on the insulation wearing it out and slowing the operation of the dampers.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Maintenance personnel secured the insulation out of the way of the ventilation dampers port and stbd engine rooms - Tested SAT.
Electrical › Electric Generation Source (emergency) › Conductor
Issued 11 March 2017
Resolved
Properly secure and cover exposed battery terminals under the stbd bridge counsel.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Maintenance personnel installed a proper battery cover. All SAT.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 March 2017
Resolved
Properly repair second deck port side aft Emergency light and secure all loose light covers on the weather decks.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Maintenance personnel replaced a burned out light bulb and secure the light covers. All SAT.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 11 March 2017
Resolved
Properly mark distress flare container "DISTRESS SIGNALS" minimum of 1/2 high lettering in a contrasting color.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Ships crew marked DISTRESS SIGNALS onto the VDS container. All SAT.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 March 2016
Resolved
CO2 System instructions are for the old system and do not match the current arrangement.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2016
Resolved 28 March 2016
Resolution: New Instructions posted in each CO2 Control Space.
Engineering › Bilge Water Management System › Piping
Issued 10 March 2016
Resolved
Bilge crossover is not capable of taking suction. Operation must be proved to the USCG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2016
Resolved 28 March 2016
Resolution: Piping to crossover pipe in each hull was replaced due to excessive wear and non sealing ability. Vessel was able to prove operation of the bilge crossover system after replacing.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 March 2016
Resolved
Battery Operated Emergency Exit lighting needs to have batteries replaced. None of them function when the ship loses power.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 28 March 2016
Resolution: Batterys were replaced and operation was verified.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 March 2016
Resolved
Expired items in first aid kit, including Iodine, Ammonia, and Aspirin are expired and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 28 March 2016
Resolution: Expired items were replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 March 2016
Resolved
Retro Reflective tape is peeling off two of the Ring buoys and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2016
Resolved 28 March 2016
Resolution: Retro Reflective tape was replaced where worn on 3 lifebuoys onboard.
Engineering › Bilge Water Management System › Interface Detector
Issued 10 March 2016
Resolved
Audible alarm was not witnessed to be operational while onboard the vessel. Proper operation must be proved to a USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2016
Resolved 28 March 2016
Resolution: 1 Bilge float sensor was replaced and proper operation of alarm panel was shown. it was determined that when 1 alarm has been silenced and has not been fully cleared, the audible alarm will not sound for any other bilge sensors until the first is clear.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 10 March 2016
Resolved
Retro Reflective tape on 1 child sized PFD was un satisfactory and must be renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 28 March 2016
Resolution: PFD retro reflective tape was replaced.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 March 2016
Resolved
Ventilation shut downs in the engineering spaces would not properly close.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2016
Resolved 28 March 2016
Resolution: Fire dampers were proved to be operational. It was found that the all thread material at the end of the cable was causing the pull to be difficult to pull. The all thread was filed down to make it easier to release.
Engineering › Freshwater Generation System › Pump
Issued 10 March 2016
Resolved
Permenantly mount potable water pump in aft void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 28 March 2016
Resolution: Water pump was permenantly mounted.
Engineering › Freshwater Generation System › Pump
Issued 10 March 2016
Resolved
Remount psi switch to potable water pump and secure wiring in port aft void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 28 March 2016
Resolution: Pump switch was secured to pump.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2016
Resolved
Replace port aft void light fixture.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 28 March 2016
Resolution: Light fixture was replaced with new unit.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2016
Resolved
Replace missing clip on stbd aft light fixture.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2016
Resolved 28 March 2016
Resolution: Missing clip was replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 March 2016
Resolved
Repair loose fuel shut off cable on port generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2016
Resolved 28 March 2016
Resolution: Fuel shut off was secured properly and proved to operate.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 March 2016
Resolved
Properly install placard(s) in both engine rooms close to the typhoon alarms stating "WHEN ALARM SOUNDS-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED".
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 28 March 2016
Resolution: Placard placed in engine compartment.