MAURY USCG vessel records Sign in
← All vessels

PHOENIX

PHOENIX is a 1987 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1987, most recently in April 2026, along with 61 deficiencies and 1 operational control.

Records from 1987 to 2026. Most recent: inspection, 6 April 2026.

Built
1987
Last inspected
6 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN7503
293238
Flag
UNITED STATES
368309050
Maury page id
psix-293238

Inspections, by type

…with no type recorded5
Years with a record 33 calendar years (1987–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)52.0 ft × 17.6 ft × 7.9 ft
Registered tonnagegross 48 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAVIS BOAT WORKS INC. · PANAMA CITY, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 7 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
38 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN7503MMSI 368309050 · active · compulsorily equipped · granted 19 April 2023, expires 19 April 2033
WDG8148MMSI 367574480 · expired · compulsorily equipped · granted 14 May 2013, cancelled 15 July 2023
WDD7847MMSI 367192160 · expired · compulsorily equipped · granted 5 June 2007, cancelled 5 August 2017 · licensed under a name not among this hull’s recorded names (not shown)
WTG4684MMSI not assigned · expired · compulsorily equipped · granted 14 March 1997, cancelled 12 May 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 70

6 April 2026 Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8343721
19 December 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285602
3 September 2025 Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226482
14 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8112020
11 March 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8093422
24 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7901391
17 January 2024 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7849715
17 January 2024 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7850533
2 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7679755
17 April 2023 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7671287
11 October 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7575104
4 May 2022 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7437995
10 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7378614
26 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7340031
6 May 2021 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7194174
2 March 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6918727
21 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6893228
30 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6824796
11 April 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6661142
15 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6411872
23 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340473
20 April 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6123793
30 August 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5986806
8 December 2015 Administrative Inspection · Hull Examination · Construction Oversight · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5814636
25 August 2015 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5225391
9 August 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4109103
13 January 2011 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3925683
19 August 2008 Annual Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3304759
15 August 2006 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2749706
10 March 2006 Plan Review "T" Boat
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2600099
22 December 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2263660
8 November 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2236761
28 September 2004 Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2207110
16 August 2004 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2167906
8 October 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1924941
17 September 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1906358
5 September 2002 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1671097
27 August 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1666955
6 August 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437959
26 April 2001 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1065282
6 February 2001 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 1521174
12 September 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054192
6 September 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1382028
7 September 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1458683
10 September 1998 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421551
15 April 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1124665
4 September 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460117
10 September 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261001
10 September 1996 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394611
26 October 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 877566
12 September 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414510
20 September 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 860952
6 September 1994 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1425501
10 December 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1159922
15 September 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149377
21 April 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151745
3 September 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943870
1 September 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1255613
15 April 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 943836
20 August 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1247123
16 May 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032243
20 February 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1214695
19 September 1990 COI Inspection · Deficiency Check · Drydock Extension
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222533
6 September 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1347737
1 March 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891980
30 November 1988 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1211984
21 September 1988 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1352732
6 April 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1206203
3 February 1988 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327478
23 September 1987 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1324534

Deficiency record · 61

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022 Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Life float drop down platform weld failed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 10 May 2022
Resolution: Repaired life float.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2022 Resolved
Inspect hull in accordance with 46 CFR 176.802. Port intermediate platform seam was untabbed in forepeak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 10 May 2022
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2019 Resolved
Waterlight must be attached to lifefloat via 18ft line. Vessel was using a 10 ft line. 46 CFR 180.175(f)(4)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 30 September 2019
Resolved 30 September 2019
Resolution: Vessel purchased 18 ft line and attahced it prior to the end of the inspectin.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 September 2019 Resolved
Emergency escape must be marked EMERGENCY EXIT KEEP CLEAR. Vsl did not have KEEP CLEAR. 46 CFR 185.606
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2019
Resolved 30 September 2019
Resolution: Vessel had appropriate markings stenciled on at the emergency exit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2019 Resolved
Safety Radio Telephony Certificate was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 17 May 2019
Resolution: Received proof of valid FCC saftey radio telephony certicate.
Construction/Loadline › Hull › Side Shell
Issued 23 January 2018 Resolved
Repair fiberglass tabbing in fwd rope compartment
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 2 February 2018
Resolution: Vessel repaired tabbing
Construction/Loadline › Hull › Stiffener
Issued 23 January 2018 Resolved
Replace identified section of cracked transverse frame stiffener in E/R overhead portside.
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 2 February 2018
Resolution: Vessel repaired transverse frame.
Electrical › Lighting (emergency) › Switch
Issued 30 August 2016 Resolved
No emergency lighting was installed
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Emergency lighting was installed
Fire Fighting › Fire Bucket › Stenciling
Issued 30 August 2016 Resolved
Stencil fire bucket
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Fire buckets were stenciled
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 30 August 2016 Resolved
Visual alarm for aft high level alarm was not operational
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Light was replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 25 August 2015 Resolved
Provide one fire extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2015
Resolution: Vessel provided fire extinguisher
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 August 2015 Resolved
Kit missing burn gel, ammonia and eye wash
Due 2 September 2015
Resolved 4 September 2015
Resolution: Vessel provided first aid kit items.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 August 2015 Resolved
provide valid system service report
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2015
Resolution: Vessel provided service report.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 August 2015 Resolved
provide 2 additional alcohol test kits
Due 9 September 2015
Resolved 4 September 2015
Resolution: Vessel provided alcohol test equipment
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 August 2015 Resolved
install intake vent covers
Due 9 September 2015
Resolved 22 October 2015
Resolution: Vessel repaired vent covers.
Fire Fighting › Means of Escape › Blocked
Issued 9 August 2011 Resolved
Provide means of opening the fwd emergency escapae hatch from both sides.
Due 11 August 2011
Resolved 11 August 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 9 August 2011 Resolved
Provide servicing certicate for the portable fire extinguishers and fire boy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Documentation › Logs/Records › Logbook (official)
Issued 9 August 2011 Resolved
Provide updated charts.
Action required: 705 - Other - as specified
Due 9 September 2011
Resolved 11 August 2011
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 August 2011 Resolved
Provide new battery for the EPIRB.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 11 August 2011
Lifesaving › Hand Flares › Expired
Issued 9 August 2011 Resolved
Provide one new smoke flare.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 August 2011 Resolved
Provide whistles on all life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Engineering › Bilge Water Management System › Not Operational
Issued 9 August 2011 Resolved
Label all bilge alarms.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 11 August 2011
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 August 2008 Resolved
Demonstrate high level bilge alarm (forward); and label bilge alarm panel.
Due 19 September 2008
Resolved 30 September 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 August 2008 Resolved
Demonstrate operation of single side band radio.
Due 19 September 2008
Resolved 30 September 2008
Engineering › Bilge Water Management System › Valve
Issued 8 November 2004 Resolved
Install positive closure device (ball valve) on machinery space electric bilge pump overboard as close to hull penetration as practicable. 46 CFR 182.520e
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 22 December 2004
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Bilge Water Management System › Hose
Issued 8 November 2004 Resolved
Install suitable flexible hose on machinery space electric bilge pump discharge. 46 CFR 182.520e.
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 22 December 2004
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Bilge Water Management System › Hose
Issued 8 November 2004 Resolved
Install suitable fitting on aft machinery space bulkhead for flex hose penetration (aft steering bilge pump discharge hose). 46 CFR 182.720
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 22 December 2004
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 November 2004 Resolved
Install emergency lighting in passenger accommodation below main deck. 46 CFR 183.432.
Action required: 705 - Other - as specified
Due 8 January 2005
Resolved 22 November 2004
Communications › Radio Communications › EPIRB
Issued 8 November 2004 Resolved
Install EPIRB in a suitable float free arrangement. 46 CFR 185.728.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 22 December 2004
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Hull › Side Shell
Issued 16 August 2004 Resolved
Noted excessive blistering, (25-32 small areas), starboard side, below chine, fore thru aft. Expose, inspect and repair as needed. Several test areas noted to only blister as far down as first mat layer over structural FRP layer.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2004
Resolved 19 August 2004
Resolution: Completed.
Construction/Loadline › Hull › Side Shell
Issued 16 August 2004 Resolved
Repair large blister area 4"x 4" forward portside.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2004
Resolved 19 August 2004
Resolution: Completed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 16 August 2004 Resolved
Repair or renew portable fire extinguisher in engine room mounted on aft bulkhead to be extinguished w/ hose and nozzle assembly seperated.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2004
Resolved 19 August 2004
Resolution: Completed.
Construction/Loadline › Structures › Deck Plating
Issued 16 August 2004 Resolved
Repair as original 4"x 6" damage caused by loose anchor in forepeak/anchor locker.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2004
Resolved 19 August 2004
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 September 2003 Resolved
Provide public address system as required by 46 CFR 184.610. LEGACY COMPONENT DESC: Public Address System
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 8 October 2003
Resolution: Owner provided public address system.
Fire Fighting › Means of Escape
Issued 17 September 2003 Resolved
Mark emergency escape hatch as required by 46 CFR 185.606. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 8 October 2003
Resolution: Owner labeled emergency escape hatch.
Personnel › Training
Issued 17 September 2003 Resolved
Provide CPR/First Aid training for 50% of the crew IAW NVIC 1-91. LEGACY COMPONENT DESC: First Aid/CPR
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 8 October 2003
Resolution: Owner provided CPR/First aid training.
Lifesaving
Issued 7 September 1999 Resolved
46 CFR 180 - REPAIR LIFE FLOAT TO ORGINAL CONDITION AS PER MANUFACTURER'S RECOMMENDATIONS.
Condition: Unknown
Due 9 September 1999
Resolved 14 February 2000
Construction/Loadline
Issued 7 September 1999 Resolved
46 CFR 182 - INSTALL REQUIRED HIGH WATER BILGE ALARMS WITH THEAPPROPRIATE AUDIBLE AND VISUAL ALARMS.
Condition: Unknown
Due 9 September 1999
Resolved 14 February 2000
Lifesaving
Issued 4 September 1997 Resolved
PROVIDE ON VESSEL A MARINE FIRST AID KIT THAT MEETS THE REQUIREMENTS OF 46 CFR 184.710 AND 160.041
Condition: Unknown
Due 4 October 1997
Resolved 30 September 1997
Lifesaving
Issued 4 September 1997 Resolved
REPLACE ONE PFD (LIFE PRESERVER) LIGHT. (LIGHT WOULD NOT CUTOFF ONCE ACTIVATED)
Condition: Unknown
Due 4 October 1997
Resolved 30 September 1997
Accommodation/Occupational Safety
Issued 12 September 1995 Resolved
INSTALL A MEANS TO DETERMINE WHEN MSD TANK IS 3/4 FULL BY VOLUME.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Engineering
Issued 12 September 1995 Resolved
INSTALL MACHINERY GUARDS ON PORT ENGINE/AC COMPRESSOR PULLY SYSTEM.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Electrical
Issued 12 September 1995 Resolved
INSTALL METAL CLAMPS ON ALL VERTICLE AND OVERHEAD WIRE/PIPE RUNS EVERY 18" TO 24"
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Documentation
Issued 12 September 1995 Resolved
PROVIDE UPDATED COPY OF 46CFR PARTS 166-199.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Construction/Loadline
Issued 12 September 1995 Resolved
PROPERLY SEAL STBD ENGINE ROOM VENT WHEN CLOSED.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Construction/Loadline
Issued 12 September 1995 Resolved
INSTALL DOUBLE HOSE CLAMP ON SINK DRAIN.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Fire Fighting
Issued 12 September 1995 Resolved
PROVIDE PROPER BRACKET FOR MAIN CABIN B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Electrical
Issued 12 September 1995 Resolved
RENEW 110V ELECTRICAL OUTLET COVER MAIN CABIN STBD SIDE.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Navigation
Issued 6 September 1994 Resolved
REVERSE BOLT AND DOUBLE NUT, NYLOCK OR COTTER PIN RAM TO TILLER ARM.
Condition: Unknown
Due 4 October 1994
Resolved 23 September 1994
Navigation
Issued 6 September 1994 Resolved
RENEW TWO HYDRAULIC HOSE ON STEERING RAM.
Condition: Unknown
Due 4 October 1994
Resolved 23 September 1994
Navigation
Issued 6 September 1994 Resolved
PROVIDE COMPASS DEVIATION TABLE FOR VESSEL
Condition: Unknown
Due 4 October 1994
Resolved 23 September 1994
Navigation
Issued 6 September 1994 Resolved
REPAIR LEAK ON HYDRAULIC STEERING SYSTEM HOSE JUNCTION.
Condition: Unknown
Due 4 October 1994
Resolved 23 September 1994
Lifesaving
Issued 15 September 1993 Resolved
INSTALL 6 FEET OF LINE CONNECTING WATERLIGHT TO RING BOUY. SEE 46 CFR 180.30-10(C).
Condition: Unknown
Due 15 September 1993
Resolved 21 September 1993
Lifesaving
Issued 15 September 1993 Resolved
POST EMERGENCY CHECK OFF LIST IN AREA VIEWABLE BY PASSENGERS.
Condition: Unknown
Due 15 September 1993
Resolved 21 September 1993
Fire Fighting
Issued 15 September 1993 Resolved
PROVE OPERATION OF AUTOMATIC VENT SHUTDOWNS SERVING ENGINE ROOM WITH FIXED FIRE SYSTEM. SEE 46 CFR 181.210-35.
Condition: Unknown
Due 15 September 1993
Resolved 21 September 1993
Construction/Loadline
Issued 15 September 1993 Resolved
INSTALL RETAINING CHAIN TO WELL DECK WATERTIGHT HATCH. SEE 46 CFR 171.124(b).
Condition: Unknown
Due 21 September 1993
Resolved 21 September 1993
Accommodation/Occupational Safety
Issued 20 August 1991 Resolved
REMOVE TINT FILM FROM PILOTHOUSE SIDE WINDOWS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1991
Resolved 20 August 1991
Engineering
Issued 20 February 1991 Resolved
INSTALL 30 X 30 WIRE MESH FLAME SCREENS TO FUEL AND MARINE SANITATION DEVICE VENT.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Documentation
Issued 23 September 1987 Resolved
PROVIDE AND PLACE ONBOARD VALID FCC LICENSE
Condition: Unknown
Due 23 September 1987
Resolved 23 September 1987
Documentation
Issued 23 September 1987 Resolved
PROVIDE AND PLACE ONBOARD VALID FCC SAFETY RADIOTELEPHONEY CERTIFICATE.
Condition: Unknown
Due 23 September 1987
Resolved 23 September 1987
Documentation
Issued 23 September 1987 Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 23 September 1987
Resolved 23 September 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.