MAURY USCG vessel records
← All vessels

PHOENIX

PHOENIX is a 1987 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in April 2026, along with 10 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 6 April 2026.

Built
1987
Last inspected
6 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN7503
293238
Flag
UNITED STATES
Maury page id
psix-293238

Documentation record

Registered dimensions (L × B × D)52.0 ft × 17.6 ft × 7.9 ft
Registered tonnagegross 48 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAVIS BOAT WORKS INC. · PANAMA CITY, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 7 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
38 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

23 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 23

6 April 2026 Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8343721
19 December 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285602
3 September 2025 Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226482
14 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8112020
11 March 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8093422
24 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7901391
17 January 2024 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7849715
17 January 2024 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7850533
2 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7679755
17 April 2023 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7671287
11 October 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7575104
4 May 2022 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7437995
10 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7378614
26 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7340031
6 May 2021 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7194174
2 March 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6918727
21 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6893228
30 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6824796
11 April 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6661142
15 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6411872
23 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340473
20 April 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6123793
30 August 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5986806

Deficiency record · 10

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022 Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Life float drop down platform weld failed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 10 May 2022
Resolution: Repaired life float.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2022 Resolved
Inspect hull in accordance with 46 CFR 176.802. Port intermediate platform seam was untabbed in forepeak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 10 May 2022
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2019 Resolved
Waterlight must be attached to lifefloat via 18ft line. Vessel was using a 10 ft line. 46 CFR 180.175(f)(4)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 30 September 2019
Resolved 30 September 2019
Resolution: Vessel purchased 18 ft line and attahced it prior to the end of the inspectin.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 September 2019 Resolved
Emergency escape must be marked EMERGENCY EXIT KEEP CLEAR. Vsl did not have KEEP CLEAR. 46 CFR 185.606
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2019
Resolved 30 September 2019
Resolution: Vessel had appropriate markings stenciled on at the emergency exit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2019 Resolved
Safety Radio Telephony Certificate was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 17 May 2019
Resolution: Received proof of valid FCC saftey radio telephony certicate.
Construction/Loadline › Hull › Side Shell
Issued 23 January 2018 Resolved
Repair fiberglass tabbing in fwd rope compartment
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 2 February 2018
Resolution: Vessel repaired tabbing
Construction/Loadline › Hull › Stiffener
Issued 23 January 2018 Resolved
Replace identified section of cracked transverse frame stiffener in E/R overhead portside.
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 2 February 2018
Resolution: Vessel repaired transverse frame.
Electrical › Lighting (emergency) › Switch
Issued 30 August 2016 Resolved
No emergency lighting was installed
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Emergency lighting was installed
Fire Fighting › Fire Bucket › Stenciling
Issued 30 August 2016 Resolved
Stencil fire bucket
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Fire buckets were stenciled
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 30 August 2016 Resolved
Visual alarm for aft high level alarm was not operational
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Light was replaced.

Ownership record