Records from 2016 to 2026. Most recent: inspection, 6 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)52.0 ft × 17.6 ft × 7.9 ft
Registered tonnagegross 48 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAVIS BOAT WORKS INC. · PANAMA CITY, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 7 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
38 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
23 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 23
6 April 2026
Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8343721
19 December 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285602
3 September 2025
Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226482
14 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8112020
11 March 2025
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8093422
24 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7901391
17 January 2024
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7849715
17 January 2024
Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7850533
2 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7679755
17 April 2023
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7671287
11 October 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7575104
4 May 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7437995
10 January 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7378614
26 October 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7340031
6 May 2021
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7194174
2 March 2020
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6918727
21 January 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6893228
30 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6824796
11 April 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6661142
15 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6411872
23 January 2018
Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340473
20 April 2017
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6123793
30 August 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5986806
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 May 2022
Resolved
Inspect lifesaving in accordance with 46 CFR 176.808. Life float drop down platform weld failed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 10 May 2022
Resolution: Repaired life float.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2022
Resolved
Inspect hull in accordance with 46 CFR 176.802. Port intermediate platform seam was untabbed in forepeak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 10 May 2022
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2019
Resolved
Waterlight must be attached to lifefloat via 18ft line. Vessel was using a 10 ft line.
46 CFR 180.175(f)(4)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 30 September 2019
Resolved 30 September 2019
Resolution: Vessel purchased 18 ft line and attahced it prior to the end of the inspectin.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 September 2019
Resolved
Emergency escape must be marked EMERGENCY EXIT KEEP CLEAR. Vsl did not have KEEP CLEAR.
46 CFR 185.606
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2019
Resolved 30 September 2019
Resolution: Vessel had appropriate markings stenciled on at the emergency exit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2019
Resolved
Safety Radio Telephony Certificate was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2019
Resolved 17 May 2019
Resolution: Received proof of valid FCC saftey radio telephony certicate.
Construction/Loadline › Hull › Side Shell
Issued 23 January 2018
Resolved
Repair fiberglass tabbing in fwd rope compartment
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 2 February 2018
Resolution: Vessel repaired tabbing
Construction/Loadline › Hull › Stiffener
Issued 23 January 2018
Resolved
Replace identified section of cracked transverse frame stiffener in E/R overhead portside.
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 2 February 2018
Resolution: Vessel repaired transverse frame.
Electrical › Lighting (emergency) › Switch
Issued 30 August 2016
Resolved
No emergency lighting was installed
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Emergency lighting was installed
Fire Fighting › Fire Bucket › Stenciling
Issued 30 August 2016
Resolved
Stencil fire bucket
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Fire buckets were stenciled
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 30 August 2016
Resolved
Visual alarm for aft high level alarm was not operational
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 30 August 2016
Resolution: Light was replaced.