Records from 2010 to 2024. Most recent: inspection, 11 November 2024.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 November 2024
No resolution recorded
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Complete dry docking, prove issuance of new Certificate Of Documentation for new vessel ownership and complete annual inspection prior to operations.
Action required: 60 - Rectify deficiencies prior to movement
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2024
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for its required drydocking and internal structural examination. Vessel is prohibited from operations until completion of satisfactory inspections.
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 March 2022
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system must have the following equipment at the operating station: A means to to reset devices used to shut down ventilation systems and engines as required. The port side engine room's fire boy indicator light stays on during normal operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2022
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The port side middle compartment's high water level alarm is not functioning as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 14 March 2022
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The vessel's anchor shank is bent and needs to be renewed.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 March 2022
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instruction. Replace all expired items.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 March 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
The EPIRB battery is expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 June 2021
Resolved
Port forward bilge pump not operating as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2021
Resolved
Ring buoy water light housing is cracked and beyond serviceable. Battery is not the approved screw type. Vessel is restricted to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2021
Resolved
Both 80 B:C portable fire extinguishers located on the main deck is not properly fastened.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 June 2021
Resolved
Forward deck hatch covers are no longer serviceable and pose a hazard to passengers. Passengers are restricted from accessing the forward bow area until repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 October 2020
Resolved
OLD T 46 CFR 182.20-10: Gages to indicate lubricating oil pressure shall be provided for all propulsion engine. Starboard main engine oil pressure inoperable. Prove proper operation of starboard main engine oil pressure gage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2020
Resolved 23 December 2020
Resolution: Vsl rep showed proper operation of stbd main engine oil pressure guage.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 October 2020
Resolved
46 CFR 184.710: A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents. First aid kit missing required items and inspected with expired contents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2020
Resolved 23 December 2020
Resolution: Vsl rep replaced expired contents.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 October 2020
Resolved
46 CFR 182.530(a): A vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station. Prove operation of starboard side high water alarm.
Action required: 10 - Deficiency Rectified
Resolved 26 October 2020
Resolution: New high water alarm installed and tested to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 October 2020
Resolved
46 CFR 180.25-25: Retro-reflective material required by this section must be Type I material that is approved under subpart 164.018 of this subchapter. Replace missing reflective tape on ring buoy with USCG approved.
Action required: 10 - Deficiency Rectified
Resolved 26 October 2020
Resolution: Crew replaced missing reflective tape with SOLAS I approved tape to the satisfaciotn of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2020
Resolved
46 CFR 183.340(b)(4) All cable and wire must be installed with a metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Replace missing chaffing guard on wire hangars in starboard side hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2020
Resolved 23 December 2020
Resolution: Stbd side hull wire hangers observed to have proper chaffing guards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2020
Resolved
46 CFR 182.455(b)(6) Fuel filter and strainer bowls must be highly resistant to failure due to thermal shock. Replace unapproved port side fuel filter with USCG approved.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2020
Resolution: Vsl rep replaced port side fuel bowl with USCG approved filter.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 October 2020
Resolved
46 CFR 177.900(g)(1): On passenger decks of a vessel on an excursion trip the following must be installed...bars, slats, rail courses or an equivalent spaced at intervals of not more than 4 inches. Replace missing chain on forward bow deck rail.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2020
Resolution: Vsl rep replaced missing bow guard rails.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2020
Resolved
OLD T 46 CFR 184.30-1: Vessels shall be equipped with a suitable number of portable battery lights. Replace batteries in portable lights and prove operation to MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2020
Resolved 23 December 2020
Resolution: Vsl rep replaced portable lights.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2020
Resolved
OLD T 46 CFR 181.30-10: Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] side portable fire extinguisher bracket inspected with broken latch. Replace bracket with new for 40-B:C fire extinguisher per NFPA 10.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2020
Resolved 23 December 2020
Resolution: Stbd side portable fire extinguisher bracket was renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 October 2020
Resolved
OLD T 46 CFR 171.124(a): Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. Replace deteriorated weather strip on bow door with new to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2020
Resolved 23 December 2020
Resolution: Bow door weatherstripping was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2019
Resolved
Replace wasted hydraulic hose for steering with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019
Resolved
Re-label electrical distribution panel at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 March 2019
Resolved
Repair or replace port side water pump for main engine with leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 March 2019
Resolved
Replace inoperable RPM for starboard engine at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 March 2019
Resolved
Replace non-marine type gaskets for deck hacth covers with watertight gasktes for marine use.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2019
Resolved
46CFR185.506/508: The vessel is prohibited from conducting simultaneous dive operations and water activities that occur at different locations. The vessel is required to be at the location per its safety passenger orientation for each water/dive activity when passengers are in the water to respond for emergencies.
Action required: 705 - Other - as specified
Due 6 February 2019
Resolved 19 March 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2019
Resolved
46CFR185.506: Vessel owner/operator must submit written procedures for documenting and accounting for each passenger for hire for USCG review and approval. Upon USCG's approval, vsl crew must demonstrate procedures for passenger orientation and accountability, and emergency instructions to the attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 6 February 2019
Resolved 19 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 June 2018
Resolved
46CFR179.360:Replace wasted non-marine type gaskets on watertight and weathertight doors and deck hatch covers with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 June 2018
Resolved
46CFR179.360:Replace missing weathertight gasket around window on forward cabin door with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2018
Resolved
46CFR180.71: Adult and child life jackets must be properly maintained to prevent deterioration from water and mold. Life jackets must be stowed away from being constantly weld to prevent mold and made easily accessible by crew and passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2018
Resolved
46CFR185.604:Remark all adult and child life jackets with the vessel's name in 2" block letters and replace reflective tape with USCG approved type.
Action required: 10 - Deficiency Rectified
Resolved 19 June 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018
Resolved
46CFR177.900:Replace broken D rings and rope guards with new rated for 200lbs as per cite.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2018
Resolved
46CFR183.340(b)(4):Replace plastic tie wraps with wire hangers to secure cable runs every 24 inches in port side hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 June 2018
Resolved
46CFR185.604(b): replace broken bronze clip for ring buoy flotation light with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2018
Resolved
46CFR182.455(b)(4): Replace broken port and starboard main fuel shut off valves with new to as original.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 March 2017
Resolved
46 CFR 183.350: Battery storage box located aft of vessel found with water inside. Battery storage must be free from exposure to water splash and spray to prevent from getting wet.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2017
Resolved
46 CFR 177.100: Make proper repairs to aft embarkation ladder. Hardware for port side grab rail connected to aft embarkation ladder must be secured.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 March 2017
Resolved
46 CFR 185.604(f): Sign for child life jackets must be made in accordance with cite and visibly displayed.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 March 2017
Resolved
46 CFR 180.10: Replace worn reflective tape on both adult and child lifejackets.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily completed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 March 2017
Resolved
46 CFR 180.71: Multiple adult and child lifejackets found with mold. Lifejackets must be serviceable and in good repair. Remove mold and make clean.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2017
Resolved
46 CFR 184.710: Kit must be watertight or stored in a watertight container. Operator to show proof of inventory to ensure all required items are accounted for.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 March 2017
Resolved
46 CFR 177.405(f): Garbage waste receptacle must be of a non-combustible type.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 29 March 2017
Resolved
33 CFR 159.59: Post placard stating sewage overboard discharge is prohibited within 3 nautical miles from shore.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 March 2017
Resolved
46 CFR 184.420: Current Tide Tables required on board as per cite.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 March 2017
Resolved
46 CFR 185.516: Replace missing lifejacket donning placard forward of operating station.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 March 2017
Resolved
46 CFR 185.520/4: Drills for fire and man overboard not logged; new deckhand joined vessel in March 2017; no proof of drills completed with for new hires.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily corrected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 September 2016
Resolved
Starboard "middle" high level bilge alarm activated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2016
Resolution: Corrected to the satisfaction of the MI.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 September 2016
Resolved
Child PFD's not in marked/designated area.
Due 23 September 2016
Resolved 27 September 2016
Resolution: Corrected to the satisfaction of MI.
Engineering › Fuel Oil Service System › Valve
Issued 12 September 2016
Resolved
Emergency fuel valve shutoff instructions unreadable.
Due 23 September 2016
Resolved 27 September 2016
Resolution: Corrected to the satisfaction of MI.
Engineering › Diesel Engine (propulsion-direct drive) › Piston Ring
Issued 1 September 2016
Resolved
Marine Inspector discovered that operator removed engine for repair due to casualty (CG was not notified).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2016
Resolution: Repairs and operational test completed to the satisfaction of the attending MI.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 September 2016
Resolved
Excess fuel and coolant was obsevred in both bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2016
Resolution: All oily mixtures removed to the satisfaction of attending MI.
Fire Fighting › Fire Bucket › Availability
Issued 1 September 2016
Resolved
Provide proper fire buckets for vessel prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2016
Resolution: Corrected to the satisfaction of attending MI.
Engineering › Sea-water System (primary cooling) › Pump
Issued 17 March 2016
Resolved
46 CFR 182.100: Starboard side engine sea water pump seal failing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: New sea water pump seal installed and pump tested with no leaks to the satisfaction of attending MI.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 March 2016
Resolved
46 CFR 184.502: Battery expired on EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2016
Resolution: Battery renewed for EPIRB to the satisfaction of attending MI.
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 March 2016
Resolved
46 CFR 182.100: Port engine alternator belt loose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2016
Resolution: Port engine alternator belt by applying tension in accordance with manufacture's specifications to the satisfaction of the attending MI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 March 2016
Resolved
46 CFR 184.710: First aid kit missing tourniquet, forcepts, scissors, 12 safety pins, wire splint, ammonia inhalants, and iodine applicators.
Due 17 April 2016
Resolved 4 April 2016
Resolution: Verified by attending MI.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 17 March 2016
Resolved
46 CFR 184.502: Captain found with no proof of FCC operator's permit. Captain is limited to 1000 feet from shore pending proof of FCC permit.
Due 17 April 2016
Resolved 22 April 2016
Resolution: Pending FCC Marine Operator Permit, O/O will operate within 1000 feet from shore.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 17 March 2016
Resolved
46 CFR 182.720(e)(v)(B): Port engine water/exhaust discharge pipe is equipped with a single hose clamp on discharge side.
Due 17 April 2016
Resolved 4 April 2016
Resolution: Verified by attending MI.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2016
Resolved
48 CFR 183.200(b): Navigation lighting wiring on roof of vessel spliced with open screw connections.
Due 17 April 2016
Resolved 5 April 2016
Resolution: Verified by attending MI.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 March 2016
Resolved
46 CFR 183.200(b): Portable CD player and speakers improperly installed-wires were splice and not properly connected to distribution panel underneath operator's station.
Due 17 April 2016
Resolved 5 April 2016
Resolution: Verified by attending MI.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 March 2016
Resolved
IMO Res A.658(16) Annex 2 (3.1): Retro-reflective tape on PFDs found worn.
Due 17 April 2016
Resolved 4 April 2016
Resolution: Verified by attending MI.
Construction/Loadline › Structures › Superstructure
Issued 17 March 2016
Resolved
46 CFR 177.1030(b): Port and starboard forward windows are damaged and difficult to see through. Replace with new.
Due 17 April 2016
Resolved 22 April 2016
Resolution: Verified by attending MI.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 17 March 2016
Resolved
46 CFR 182.455(b): No method available for starboard fuel tank. Provide as required.
Due 17 April 2016
Resolved 5 April 2016
Resolution: Verified by attending MI.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 March 2016
Resolved
46 CFR 177.100: Suspected de-lamination of FRP in port forward collision space. Monitor condition until next avble. dry dock scheduled for 04APR16.
Action required: 705 - Other - as specified
Resolved 5 April 2016
Resolution: Verified by attending MI.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 17 March 2016
Resolved
46 CFR 182.410(b): Port engine tachometer inoperable. Repair as required.
Due 17 April 2016
Resolved 22 April 2016
Resolution: Inspected to the satisfaction of attending MI.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 March 2016
Resolved
Owner/Operator is to provide a licensed master at all times during operation with passengers. Master of vessel was observed operating the vessel with 29 passengers without a valid Masters license.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 March 2016
Resolution: Owner/Operator is to provided a licensed master at all times during operation with passengers.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 March 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 1 April 2016