OCEAN SPIRIT
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Oceania District (CGD-O) · Other hulls named OCEAN SPIRIT
OCEAN SPIRIT is a 1987 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1987, most recently in November 2024, along with 207 deficiencies — 2 with no resolution recorded —, 4 operational controls and 3 casualty investigations between 2010 and 2015.
Records from 1987 to 2024. Most recent: inspection, 11 November 2024.
- Built
- 1987
- Last inspected
- 11 November 2024
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 207 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2010–2015
Identity
986979
WDK3210
293264
Flag
UNITED STATES
367350430
Maury page id
psix-293264
Inspections, by type
…with no type recorded16
Years with a record
35 calendar years (1987–2024)
The 90 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 16.7 ft × 3.7 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND DESIGNED BOATS · TAMUNING, GUAM · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationTwin Hull
Hailing portPITI, GU
Trade endorsementsRecreational
DocumentationValid · issued 5 May 2025 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
6 - Simplified, Net Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK3210MMSI 367350430 · active · compulsorily equipped · granted 5 June 2018, expires 5 June 2028
WDE4228MMSI 367350430 · terminated · compulsorily equipped · granted 18 April 2008, cancelled 1 June 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 90
11 November 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8036753
29 April 2024
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7903724
6 July 2023
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7734341
17 April 2022
Examination of Repairs · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7431431
3 March 2022
Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7404865
2 June 2021
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7212899
23 December 2020
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7115401
23 March 2020
Internal Structural Exam · Drydock Extension · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6935779
18 March 2020
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6929864
10 August 2019
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 6778471
4 June 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6702928
3 April 2019
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 6669858
19 March 2019
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6675780
4 February 2019
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6620703
19 June 2018
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6450976
10 April 2018
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6410596
23 November 2017
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 6311933
29 March 2017
COI Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6113361
12 September 2016
Deficiency Check · In-Service Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5998289
1 September 2016
In-Service Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5990005
4 April 2016
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5847389
17 March 2016
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5834837
15 March 2016
In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5833321
15 March 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5842502
19 October 2014
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 5007745
11 October 2014
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 5003256
15 May 2014
DAPI Audit · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4950433
30 July 2012
Spot Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4394965
28 July 2011
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4096745
27 July 2011
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4095489
25 July 2011
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4093213
22 October 2010
In-Service Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3874986
13 October 2010
Type not recorded
No type recorded · Station Apra Harbor · USCG Oceania District (CGD-O) · Activity 3869553
23 April 2009
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3458561
23 April 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3461514
20 March 2008
Annual Inspection · Hull Examination · Plan Review "T" Boat
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3167853
2 May 2007
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2920185
9 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2740862
28 June 2006
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2639147
5 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2670286
30 January 2006
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2575600
29 January 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2575697
23 January 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2571211
19 January 2006
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2569139
23 December 2004
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2263840
1 September 2004
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2182868
11 June 2004
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2102027
19 May 2003
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1796085
7 May 2003
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1788122
5 June 2002
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1626422
15 May 2002
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1617400
1 May 2002
COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1611663
3 September 2001
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1073238
12 June 2001
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1070607
11 May 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1387070
3 March 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1059092
14 June 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1052427
8 June 2000
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365813
5 May 2000
Excursion Permit
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1049687
4 May 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1399362
12 September 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 783926
17 August 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 777976
8 June 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 813149
6 May 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1360851
30 October 1998
Plan Review "T" Boat
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 804374
15 June 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 797184
3 June 1998
Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1123898
26 July 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1371932
8 June 1997
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 774815
14 May 1997
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 774813
30 May 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1087302
15 May 1996
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1086213
30 April 1996
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1082883
6 July 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 689309
23 September 1994
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1175554
24 March 1994
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1165875
24 September 1993
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 829494
22 December 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1137558
5 October 1992
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1260825
16 March 1992
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1258825
27 September 1991
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 934653
27 September 1991
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 940197
24 September 1990
Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1220156
14 January 1989
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1202718
8 November 1988
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1202222
4 November 1988
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1203511
23 August 1988
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1349615
16 August 1988
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1349616
4 August 1987
Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1016283
4 August 1987
COI Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1349614
Deficiency record · 207
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 November 2024
No resolution recorded
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Complete dry docking, prove issuance of new Certificate Of Documentation for new vessel ownership and complete annual inspection prior to operations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2024
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for its required drydocking and internal structural examination. Vessel is prohibited from operations until completion of satisfactory inspections.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 March 2022
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system must have the following equipment at the operating station: A means to to reset devices used to shut down ventilation systems and engines as required. The port side engine room's fire boy indicator light stays on during normal operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 March 2022
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The port side middle compartment's high water level alarm is not functioning as designed.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 14 March 2022
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The vessel's anchor shank is bent and needs to be renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 March 2022
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instruction. Replace all expired items.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 March 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
The EPIRB battery is expired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 June 2021
Resolved
Port forward bilge pump not operating as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2021
Resolved
Ring buoy water light housing is cracked and beyond serviceable. Battery is not the approved screw type. Vessel is restricted to daylight operations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2021
Resolved
Both 80 B:C portable fire extinguishers located on the main deck is not properly fastened.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 June 2021
Resolved
Forward deck hatch covers are no longer serviceable and pose a hazard to passengers. Passengers are restricted from accessing the forward bow area until repaired or replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 October 2020
Resolved
OLD T 46 CFR 182.20-10: Gages to indicate lubricating oil pressure shall be provided for all propulsion engine. Starboard main engine oil pressure inoperable. Prove proper operation of starboard main engine oil pressure gage.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 October 2020
Resolved
46 CFR 184.710: A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents. First aid kit missing required items and inspected with expired contents.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 October 2020
Resolved
46 CFR 182.530(a): A vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station. Prove operation of starboard side high water alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 October 2020
Resolved
46 CFR 180.25-25: Retro-reflective material required by this section must be Type I material that is approved under subpart 164.018 of this subchapter. Replace missing reflective tape on ring buoy with USCG approved.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 October 2020
Resolved
46 CFR 183.340(b)(4) All cable and wire must be installed with a metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Replace missing chaffing guard on wire hangars in starboard side hull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2020
Resolved
46 CFR 182.455(b)(6) Fuel filter and strainer bowls must be highly resistant to failure due to thermal shock. Replace unapproved port side fuel filter with USCG approved.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 October 2020
Resolved
46 CFR 177.900(g)(1): On passenger decks of a vessel on an excursion trip the following must be installed...bars, slats, rail courses or an equivalent spaced at intervals of not more than 4 inches. Replace missing chain on forward bow deck rail.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2020
Resolved
OLD T 46 CFR 184.30-1: Vessels shall be equipped with a suitable number of portable battery lights. Replace batteries in portable lights and prove operation to MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2020
Resolved
OLD T 46 CFR 181.30-10: Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] side portable fire extinguisher bracket inspected with broken latch. Replace bracket with new for 40-B:C fire extinguisher per NFPA 10.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 October 2020
Resolved
OLD T 46 CFR 171.124(a): Each hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. Replace deteriorated weather strip on bow door with new to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2019
Resolved
Replace wasted hydraulic hose for steering with new.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2019
Resolved
Re-label electrical distribution panel at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 March 2019
Resolved
Repair or replace port side water pump for main engine with leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 March 2019
Resolved
Replace inoperable RPM for starboard engine at operating station.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 March 2019
Resolved
Replace non-marine type gaskets for deck hacth covers with watertight gasktes for marine use.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2019
Resolved
46CFR185.506/508: The vessel is prohibited from conducting simultaneous dive operations and water activities that occur at different locations. The vessel is required to be at the location per its safety passenger orientation for each water/dive activity when passengers are in the water to respond for emergencies.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2019
Resolved
46CFR185.506: Vessel owner/operator must submit written procedures for documenting and accounting for each passenger for hire for USCG review and approval. Upon USCG's approval, vsl crew must demonstrate procedures for passenger orientation and accountability, and emergency instructions to the attending USCG Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 June 2018
Resolved
46CFR179.360:Replace wasted non-marine type gaskets on watertight and weathertight doors and deck hatch covers with new.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 June 2018
Resolved
46CFR179.360:Replace missing weathertight gasket around window on forward cabin door with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2018
Resolved
46CFR180.71: Adult and child life jackets must be properly maintained to prevent deterioration from water and mold. Life jackets must be stowed away from being constantly weld to prevent mold and made easily accessible by crew and passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2018
Resolved
46CFR185.604:Remark all adult and child life jackets with the vessel's name in 2" block letters and replace reflective tape with USCG approved type.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 June 2018
Resolved
46CFR177.900:Replace broken D rings and rope guards with new rated for 200lbs as per cite.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2018
Resolved
46CFR183.340(b)(4):Replace plastic tie wraps with wire hangers to secure cable runs every 24 inches in port side hull.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 June 2018
Resolved
46CFR185.604(b): replace broken bronze clip for ring buoy flotation light with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2018
Resolved
46CFR182.455(b)(4): Replace broken port and starboard main fuel shut off valves with new to as original.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 March 2017
Resolved
46 CFR 183.350: Battery storage box located aft of vessel found with water inside. Battery storage must be free from exposure to water splash and spray to prevent from getting wet.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2017
Resolved
46 CFR 177.100: Make proper repairs to aft embarkation ladder. Hardware for port side grab rail connected to aft embarkation ladder must be secured.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 March 2017
Resolved
46 CFR 185.604(f): Sign for child life jackets must be made in accordance with cite and visibly displayed.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 March 2017
Resolved
46 CFR 180.10: Replace worn reflective tape on both adult and child lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 March 2017
Resolved
46 CFR 180.71: Multiple adult and child lifejackets found with mold. Lifejackets must be serviceable and in good repair. Remove mold and make clean.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2017
Resolved
46 CFR 184.710: Kit must be watertight or stored in a watertight container. Operator to show proof of inventory to ensure all required items are accounted for.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 March 2017
Resolved
46 CFR 177.405(f): Garbage waste receptacle must be of a non-combustible type.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 29 March 2017
Resolved
33 CFR 159.59: Post placard stating sewage overboard discharge is prohibited within 3 nautical miles from shore.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 March 2017
Resolved
46 CFR 184.420: Current Tide Tables required on board as per cite.
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 March 2017
Resolved
46 CFR 185.516: Replace missing lifejacket donning placard forward of operating station.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 March 2017
Resolved
46 CFR 185.520/4: Drills for fire and man overboard not logged; new deckhand joined vessel in March 2017; no proof of drills completed with for new hires.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 September 2016
Resolved
Starboard "middle" high level bilge alarm activated.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 September 2016
Resolved
Child PFD's not in marked/designated area.
Engineering › Fuel Oil Service System › Valve
Issued 12 September 2016
Resolved
Emergency fuel valve shutoff instructions unreadable.
Engineering › Diesel Engine (propulsion-direct drive) › Piston Ring
Issued 1 September 2016
Resolved
Marine Inspector discovered that operator removed engine for repair due to casualty (CG was not notified).
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 September 2016
Resolved
Excess fuel and coolant was obsevred in both bilges.
Fire Fighting › Fire Bucket › Availability
Issued 1 September 2016
Resolved
Provide proper fire buckets for vessel prior to operating.
Engineering › Sea-water System (primary cooling) › Pump
Issued 17 March 2016
Resolved
46 CFR 182.100: Starboard side engine sea water pump seal failing.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 March 2016
Resolved
46 CFR 184.502: Battery expired on EPIRB.
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 March 2016
Resolved
46 CFR 182.100: Port engine alternator belt loose.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 March 2016
Resolved
46 CFR 184.710: First aid kit missing tourniquet, forcepts, scissors, 12 safety pins, wire splint, ammonia inhalants, and iodine applicators.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 17 March 2016
Resolved
46 CFR 184.502: Captain found with no proof of FCC operator's permit. Captain is limited to 1000 feet from shore pending proof of FCC permit.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 17 March 2016
Resolved
46 CFR 182.720(e)(v)(B): Port engine water/exhaust discharge pipe is equipped with a single hose clamp on discharge side.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2016
Resolved
48 CFR 183.200(b): Navigation lighting wiring on roof of vessel spliced with open screw connections.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 March 2016
Resolved
46 CFR 183.200(b): Portable CD player and speakers improperly installed-wires were splice and not properly connected to distribution panel underneath operator's station.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 March 2016
Resolved
IMO Res A.658(16) Annex 2 (3.1): Retro-reflective tape on PFDs found worn.
Construction/Loadline › Structures › Superstructure
Issued 17 March 2016
Resolved
46 CFR 177.1030(b): Port and starboard forward windows are damaged and difficult to see through. Replace with new.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 17 March 2016
Resolved
46 CFR 182.455(b): No method available for starboard fuel tank. Provide as required.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 March 2016
Resolved
46 CFR 177.100: Suspected de-lamination of FRP in port forward collision space. Monitor condition until next avble. dry dock scheduled for 04APR16.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 17 March 2016
Resolved
46 CFR 182.410(b): Port engine tachometer inoperable. Repair as required.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 March 2016
Resolved
Owner/Operator is to provide a licensed master at all times during operation with passengers. Master of vessel was observed operating the vessel with 29 passengers without a valid Masters license.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 March 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 July 2012
Resolved
On passenger decks of a vessel on an excursion trip the following must be installed on vessels with 39.5 inch handrails: 1. Bulwarks 2. Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter or 3. Bars, slats, rail courses, or an equivalent spaced at intervals of not more 100 millimeters (4 inches) IAW 46 CFR 177.900 (g)(1) (i)-(iii)
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 25 July 2011
Resolved
Show proof of Marine radio operators permit for [name withheld] Vessel is limited to not more than a thousand feet from shore while he's operating until proof is shown.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 July 2011
Resolved
First page of the COI was missing. Vessel operator stated that the insurance rep took it and hasn't brought it back. First page needs to be returned or another one needs to be issued.
Communications › Alarms/Indicators › High Water Alarm
Issued 22 October 2010
Resolved
Repair audible alarm for port fwd bilge high water alarm.
Vsl crew must make 5 minute rounds checking the port fwd space until corrected.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 April 2009
Resolved
Provide a valid/current COD.
Lifesaving › Lifefloat › Markings
Issued 23 April 2009
Resolved
Restencil vessel name on LF.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 April 2009
Resolved
Repair weld crack on aft starboard hand rail. Next available dry dock.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 April 2009
Resolved
Install a detachment clip on Ring Life Bouy lanyard.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 April 2009
Resolved
Provide a valid FCC safety certification.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 23 April 2009
Resolved
Provide a valid FCC operator permit.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 April 2009
Resolved
Provide a proof of enrollment for vessel crew.
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2008
Resolved
Repair all marked off hull damage and delaminated area's on hull and repair port hull intermidiate frame between frames 5-6.
Construction/Loadline › Structures › Superstructure
Issued 20 March 2008
Resolved
Repair deck house area which are marked off on all areas that the bow rail bolted and was not backed, damaged the deck house, build up the area with new glass.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 20 March 2008
Resolved
Replace port sea strainer in the bottom of the hull due to deteriation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2008
Resolved
Replace all plastic wire ties with steel hangars.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 20 March 2008
Resolved
Repair fuel leak on stbd engine return line @ the engine.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 March 2008
Resolved
Replace out dated items in 1st aid kit.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 20 March 2008
Resolved
Repair faulty fresh water temp gauge, trouble shoot reason for gauge not working properly.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 2 May 2007
Resolved
Found vessel operator unable to provide fixed firefighting system servicing certificate. Prove vessels fixed system has had annual servicing.
Communications › Radio Communications › EPIRB
Issued 2 May 2007
Resolved
Found EPIRB with an expired battery. Replace prior to operating more than three miles from shore.
Documentation › Certificates/Documents › FCC SSL
Issued 2 May 2007
Resolved
Found vessel operator without a FCC Marine Radio Operator Permit. Prove operator carries a valid permit.
Navigation › Piloting/Steering › Marine Charts
Issued 2 May 2007
Resolved
Found vessels charts not corrected. Prove charts are current with local notice to mariners.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 May 2007
Resolved
Found vessel missing tidal current tables. Prove vessel has on board tidal current tables or calculation method.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2007
Resolved
Found bow deck rail opening not fitted with a rope 12 inches from the deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2007
Resolved
Found aft deck rail rope connection broken. Make permanent repairs to connection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2007
Resolved
Found forward life buoy water light not connected with a corrosion resistant clip. Make waterlight lanyard proper with clip.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2007
Resolved
Found forward life buoy grab line dryrotted. Replace grab line.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2007
Resolved
Found first aid kit storage location not marked. Properly mark storage location of first aid kit.
Engineering › Lubricating Oil Service System › Gauge
Issued 2 May 2007
Resolved
Found both main engine oil pressure gauges not properly operating. Prove proper operation of both oil pressure gauges.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 May 2007
Resolved
Found both remote emergency fuel shutoffs for main engines not labeled. Properly label both remote shutoffs.
Fire Fighting › Ventilation Systems › Ducts
Issued 2 May 2007
Resolved
Found starboard engine room ventilation closure unable to close. Prove proper operation of ventilation closure.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2007
Resolved
Found port center bilge pump visual indicator not properly operating. Prove proper operation of bilge pump visual indicators.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2007
Resolved
Found multiple dead end wires in way of operators station. Remove all dead end wires or properly label both ends and end in a junction box.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2007
Resolved
Found improper wire connections in way of operators station. Make all connections with proper connectors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2007
Resolved
Found worne and exposed wiring in way of operators station. Replace worn wiring.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 28 June 2006
Resolved
Found retro reflective material worn. Replace retro reflective material.
Lifesaving › Lifebuoys › Serviceable
Issued 28 June 2006
Resolved
Found retro reflective material worn. Replace retro reflective material.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 June 2006
Resolved
Found navigational publications out of date. Replace publications with current 2006 editions.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 June 2006
Resolved
Found EPIRB missing vessel name. Stencil vessel name on EPIRB.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 28 June 2006
Resolved
Found vessel missing emergency fuel oil shutoff valves to engines. Install emergency fuel oil shutoff valves to each engine.
Lifesaving › Hand Flares › Quantity
Issued 28 June 2006
Resolved
Found vessel missing 3 red hand flares. Prove vessel has proper quantity of hand flares.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 January 2006
Resolved
Found certificate of documentation expired. Prove vessel has current certificate of documentation.
Operations/Management › Pollution › Control of Garbage
Issued 30 January 2006
Resolved
Found vessel did not have a waste management plan.
Personnel › Training › First Aid/CPR
Issued 30 January 2006
Resolved
Found CPR/first aid cards expired. Prove 50% of crew have valid CPR/first aid cards.
Operations/Management › Drills/Instruction › Fire
Issued 30 January 2006
Resolved
Found vessel missing training, lifesaving equipment and bridge logs. Establish logs.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 January 2006
Resolved
Found vessel missing or out dated navigational publications. Prove vessel has current corrected chart, U.S Coast Pilot, Coast Guard light list, Tide Tables and Tidal Current Tables.
Lifesaving › Hand Flares › Quantity
Issued 30 January 2006
Resolved
Found vessel missing proper quantity of signaling devises. Prove vessel has 6 red hand flares and 6 orange smokes.
Lifesaving › Lifefloat › Paddle
Issued 30 January 2006
Resolved
Found life float missing paddles. Prove life float has 2 paddle, attached and with the vessels names stenciled on them.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 January 2006
Resolved
Found vessel missing approved fixed fire extinguishing system. Prove vessel has approved system. Authorization to continue to operate is based on 2 addition 30 pound ABC extinguishers on board IWO engine room.
Engineering › Bilge Water Management System › Interface Detector
Issued 30 January 2006
Resolved
Found bilge pump visual indicators not operational. Prove visual indicators work on all bilge pumps.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 30 January 2006
Resolved
Found bilge high level alarm in starboard amidships not operational. Prove all bilge alarms operate.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 January 2006
Resolved
Found vessel not ready for inspection, removed COI for 2 week to allow them to complete repairs.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 January 2006
Resolved
Found vessel had not completed required annual inspection within the approved time period. Completed annual inspection prior to operating with passenger.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 1 September 2004
Resolved
MARK LIFEJACKET STOWAGE AREAS
Lifesaving › Lifefloat › Pendant
Issued 1 September 2004
Resolved
INSTALL LIFE LINE/PENDANTS IAW 46 CFR 160,010-4
Engineering › Fuel Oil Service System › Filter
Issued 1 September 2004
Resolved
INSTALL FUEL FILTER FLAME SHIELD ON FUEL FILTER BOWL.
Engineering › Bilge Water Management System › Not Operational
Issued 1 September 2004
Resolved
REPAIR PORT AND STBD AMIDSHIPS AUTO-BILGE AND ALARM OPERATION. CONDUCT FREQUENT INSPECTIONS WHILE UNDERWAY UNTIL REPAIRED.
Engineering › Bilge Water Management System › Not Operational
Issued 1 September 2004
Resolved
REPAIR STBD ENGINE ROOM AUTO-BILGE AND ALARM OPERATION. CONDUCT FREQUENT INSPECTIONS WHILE UNDERWAY UNTIL REPAIRED.
Lifesaving
Issued 7 May 2003
Resolved
Deteriorated retroreflective material requires renewal of LF/BA and PFDs per 46 CFR 185.604.
Engineering
Issued 7 May 2003
Resolved
Owner/operator to demonstrate proper operation of emergency fuel shutoffs, mandated under 46 CFR 182.455, not later than 21 May 2003.
Construction/Loadline › Structures
Issued 5 June 2002
Resolved
Railing fractured in way of bow. Permanent repair required prior to completion of drydock. LEGACY COMPONENT DESC: Railing
Construction/Loadline › Structures
Issued 5 June 2002
Resolved
Roof support in way of portside centerline seating aft fractured. Permanent repair required prior to completion of drydock. LEGACY COMPONENT DESC: Roof support (Pipe style)
Construction/Loadline › Penetrations
Issued 5 June 2002
Resolved
Upper bow compartments missing threaded drain plugs. Permanent correction required prior to completion of drydock. LEGACY COMPONENT DESC: Bottom Plug
Construction/Loadline › Hull
Issued 5 June 2002
Resolved
Several port centerline bow compartment deck support fasteners loose/missing. Proper corrective action required prior to drydock completion. LEGACY COMPONENT DESC: Support bracket fasteners
Construction/Loadline › Penetrations
Issued 5 June 2002
Resolved
Centerline bow door gasket material not connected. Corrective action required prior to drydock completion. LEGACY COMPONENT DESC: Gasket
Construction/Loadline › Structures
Issued 5 June 2002
Resolved
Bow hatch hinges loose, potentially allowing ingress of water into upper bow compartment. Corrective action required prior to drydock completion. LEGACY COMPONENT DESC: Bow Hatch Hinges
Engineering › Fuel Oil Storage/Transfer System
Issued 5 June 2002
Resolved
On stbd fuel tank the fuel line fitting attached to the fuel tank is loose creating possible fuel leakage & creation of an explosive atmosphere. Permanent correction prior to drydocking completion required. Use of sealant considered to be an unsatisfactory permanent corrective action. LEGACY COMPONENT DESC: Piping
Engineering › Gasoline Engine (propulsion)
Issued 5 June 2002
Resolved
Upper port outdrive casing severely corroded/wasted. Permanent corrective action required prior to drydock completion. LEGACY COMPONENT DESC: Outdrive casing
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 5 June 2002
Resolved
Port and stbd fixed gas fire extinguishing systems disconnected by owner/operator to facilitate inspection. Prior to completion of drydock the systems shall be reinstalled and inspected by a qualified technician iaw manufacturer's instructions & federal requirements. LEGACY COMPONENT DESC: Quantity of Gas
Construction/Loadline › Hull
Issued 5 June 2002
Resolved
Lower roof bracket, aft port side centerline in way of passenger seating, deteriorated. Permanent repair required prior to drydock completion. LEGACY COMPONENT DESC: Bracket
Lifesaving
Issued 1 May 2002
Resolved
Vsl's 406 mHz EPIRB not registered with the National Oceanic and Atmospheric Administration (NOAA). Corrective action shall be implemented not later than 15 May 02. LEGACY COMPONENT DESC: 406 mHz EPIRB Registration
Documentation › Logs/Records
Issued 1 May 2002
Resolved
Log Book entries pertaining to man overboard drills, firefighting drills, monthly EPIRB tests, & survival craft maintenance not conducted in non-adherence w/46 CFR 185. Corrective action shall be commenced immediatly w/drills conducted 01 May 02 logged. LEGACY COMPONENT DESC: Logbook Entries
Electrical › Lighting (service)
Issued 1 May 2002
Resolved
Compass light not operable in non-adherence with 46 CFR 184.402. Corrective action shall be implemented not later than 15 May 02. LEGACY COMPONENT DESC: Compass Light
Electrical › Lighting (emergency)
Issued 1 May 2002
Resolved
DC overhead lighting, previously installed in aft portion of vsl along the centerline, removed w/o authorization. DC overhead lighting shall be installed per plan approval conducted in accordance with 46 CFR Subchapter T not later than 15 May 02. LEGACY COMPONENT DESC: Emergency Overhead Lighting
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 May 2002
Resolved
B-I portable fire extinguisher, required pursuant to 46 CFR 181, not serviced in non-adherence with NFPA 10. Corrective action required not later than 15 May 02.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 1 May 2002
Resolved
Port and Stbd fixed fire extinguishing systems not serviced in non-adherence with 46 CFR 181 and manufacturer's requirements. Servicing shall be conducted by qualified party and documentation of such servicing made available to the USCG not later than 01 Jun 02. LEGACY COMPONENT DESC: Servicing
Navigation › Piloting/Steering
Issued 1 May 2002
Resolved
Chart 81067 dated 1990 not currently corrected in non-adherence with 46 CFR 184. Chart shall be corrected to date not later than 15 May 02. LEGACY COMPONENT DESC: Marine Charts
Navigation › Piloting/Steering
Issued 1 May 2002
Resolved
Coast Pilot not currently corrected in non-adherence with 46 CFR 184. Corrective action shall be implemented not later than 15 May 02. LEGACY COMPONENT DESC: US Coast Pilot
Navigation › Piloting/Steering
Issued 1 May 2002
Resolved
Light List not currently corrected in non-adherence with 46 CFR 184. Corrective action shall be implemented not later than 15 May 02. LEGACY COMPONENT DESC: Light List
Fire Fighting › Fire Pumps
Issued 1 May 2002
Resolved
Hand fire pump discharge hose leaking in non-adherence with 46 CFR 181. Corrective action to be implemented not later than 15 May 02. LEGACY COMPONENT DESC: Hand Pump
Engineering › Fuel Oil Storage/Transfer System
Issued 1 May 2002
Resolved
Stbd engine emergency fuel shutoff not serving its intended purpose in non-adherence with 46 CFR 182.455. Owner/operator shall demonstrate proper function of fuel shutoff not later than 15 May 02. LEGACY COMPONENT DESC: Emergency Fuel ShutOff
Engineering
Issued 1 May 2002
Resolved
Port & Stbd engine compartment ventilation closures not functioning in non-adherence to 46 CFR Subchapter T due to improper design thereby allowing escape of fire extinguishing gases in an emergency situation. Corrective action shall be implemented not later than 15 May 02. LEGACY COMPONENT DESC: Engine Compartment Ventilation Closures
Unknown
Issued 11 May 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 11 May 2001
Resolved
Renew the ring buoy at the operating station.
Lifesaving
Issued 11 May 2001
Resolved
Replace buoyant apparatus with life floats and associated equipment having sufficient capacity for 26 persons. In lieu of this, the company may provide a 406 MHZ, Cat I EPIRB for the vessel.
Construction/Loadline
Issued 11 May 2001
Resolved
Prove the operation of the visible indicator light for the aft high level bilge alarm in the stbd hull.
Lifesaving
Issued 11 May 2001
Resolved
Update the equipment in the first aid kit.
Engineering
Issued 11 May 2001
Resolved
Install valve stop guides on the port and stbd emergency fuel tank shut-offvalves.
Construction/Loadline
Issued 4 May 2000
Resolved
Seal all openings on the forward bulkheads of the port and stbd engine rooms.
Construction/Loadline
Issued 4 May 2000
Resolved
Prove the operation of the aft bilge pump in the center compartment of the stbd hull.
Fire Fighting
Issued 4 May 2000
Resolved
Prove the operation of the safeties and alarms for the fixed firefighting systems in both engine rooms.
Construction/Loadline
Issued 4 May 2000
Resolved
Provide sufficient length of hose for the portable bilge pump capable of dewatering any compartment on the vessel and discharging directly overboard.
Lifesaving
Issued 4 May 2000
Resolved
Provide one additional adult lifejacket. Passenger capacity is reduced to a maximum of 48 until completion.
Engineering
Issued 4 May 2000
Resolved
Prove the operation of the port and stbd engine ignition/remote shut-down switches.
Navigation
Issued 4 May 2000
Resolved
Provide a copy of the Navigation rules (72 COLREGS) for the vessel.
Lifesaving
Issued 4 May 2000
Resolved
Conduct fire and abandon ship drills in the presence of USCG marine inspector.
Fire Fighting
Issued 4 May 2000
Resolved
Service all portable fire extinguishers.
Engineering
Issued 6 May 1999
Resolved
Repair/replace remote fuel shut-off valve starboard side.
Accommodation/Occupational Safety
Issued 6 May 1999
Resolved
Lock MSD overboard discharge valve.
Construction/Loadline
Issued 6 May 1999
Resolved
Double clamp all bilge discharge hoses.
Construction/Loadline
Issued 6 May 1999
Resolved
Replace forward port bilge discharge hose.
Electrical
Issued 6 May 1999
Resolved
Elect bond fuel fill pipe.
Lifesaving
Issued 6 May 1999
Resolved
Replace retroreflective tape on lifejackets (10).
Navigation
Issued 6 May 1999
Resolved
Permanently install radio.
Accommodation/Occupational Safety
Issued 6 May 1999
Resolved
Change rail courses to proper spacing intervals.
Lifesaving
Issued 6 May 1999
Resolved
Post lifejacket donning placards for both types carried on board.
Navigation
Issued 6 May 1999
Resolved
Place on board navigation chart for operating area.
Documentation
Issued 6 May 1999
Resolved
All operators of vessel must obtain valid FCC operator licenses.
Lifesaving
Issued 3 June 1998
Resolved
Conduct Man Overboard and Firefighting drills and log the date/general description on vsl's logbook as per 46 CFR 185.520/.524.
Navigation
Issued 3 June 1998
Resolved
Provide updated navigation charts, tide tables, lightlist for area of operation.
Electrical
Issued 14 May 1997
Resolved
COVER PORT & STBD BATTERIES WITH BATTERY COVERS.
Navigation
Issued 14 May 1997
Resolved
PROVIDE NAVIGATION CHART, RULES OF THE ROAD, TIDE TABLES FOR AREA OF OPERATION.
Engineering
Issued 14 May 1997
Resolved
PROVIDE ROTATING MACHINERY GUARDS ON PORT AND STBD MDE._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 14 May 1997
Resolved
REPLACE BILGE LINE WITH WIRE REENFORCED HOSES. REMOVE ALL PLASTIC PIPING AMIDSHIPS.
Construction/Loadline
Issued 14 May 1997
Resolved
REPLACE ENGINE ROOM BILGE LINE WITH WIRE REENFORCED HOSES.
Documentation
Issued 14 May 1997
Resolved
OBTAIN ORIGINAL COI FOR ENDORSEMENT OF REINSPECTION.
Navigation
Issued 14 May 1997
Resolved
CLEAN RUSTY HYDRAULIC STEERING COUPLINGS ON STBD SIDE ENGINE ROOM.
Unknown
Issued 14 May 1997
Resolved
SHOW EVIDENCE OF DRUG TESTING PROGRAM.
Engineering
Issued 14 May 1997
Resolved
REPLACE RUBBER HOSES ON PORT & STBD MDE. HOSES RUN FROM FUEL TANK TO MDE. REPLACE AS ORIGINAL WITH COPPER FUEL LINES.
Lifesaving
Issued 14 May 1997
Resolved
PROVIDE ONE RED PARACHUTE FLARE, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Navigation
Issued 14 May 1997
Resolved
PROVIDE VHF-FM RADIO, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Lifesaving
Issued 14 May 1997
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, STENCIL THE 12 AND 20 PERSON BUOYANTAPPARATUS WITH VSL NAME AND NUMBER OF PERSONS ALLOWED. ALL TO BE IN 1 INCHLETTERS.
Lifesaving
Issued 14 May 1997
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPLACE RING BUOY LIGHT W/OPERABLE WATERLIGHT AND PUT REQUIRED RETRO-REFLECTIVE TAPE TO ENCOMPASS RING BUOY IN4 RINGS. ALSO PUT NAME OF VSL AND SAIPAN ON RING BUOY.
Lifesaving
Issued 14 May 1997
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE EMERGENCY CHECK-OFF LIST ANDPOST IN JAPANESE AND ENGLISH.
Navigation
Issued 14 May 1997
Resolved
PRIOR TO VSL OPERATION, PROVIDE ADEQUATE VSL HORN.
Fire Fighting
Issued 14 May 1997
Resolved
PRIOR TO VSL OPERATION, LABEL FIRE EXTINGUISHER BOXES.
Fire Fighting
Issued 14 May 1997
Resolved
PROVIDE HAND FIRE/BILGE PUMP.
Engineering
Issued 14 May 1997
Resolved
RELABEL FUEL SHUT-OFF VALVES WITH "EMERGENCY FUEL SHUT OF VALVES" WITH 1" LETTERS.
Lifesaving
Issued 14 May 1997
Resolved
PROVIDE 22 ADULT LIFEJACKETS AND REAPPLY RETRO-REFLECTIVE TAPE TO 36 ADULT LIFEJACKETS. NO PASSENGERS SHALL BE CARRIED UNTIL ALL 36 HAVE RETRO. WHENALL 36 HAVE RETRO, VSL RESTRICTED TO 36 PASSENGERS. WHEN ADDITIONAL LIFEJACKETS ARE OBTAINED PASSENGER ALLOWANCE WILL BE ADJUSTED ACCORDINGLY.
Fire Fighting
Issued 14 May 1997
Resolved
PROVIDE 3 2&1/2 GAL BUCKETS.
Navigation
Issued 14 May 1997
Resolved
PROVIDE 18 INCH FLAT BLACK NAV LIGHT SCREEN FOR PORT AND STBD NAV LIGHTS.
Lifesaving
Issued 15 May 1996
Resolved
Obtain one orange smoke and three red flares to replace outdated/missing pyrotechnics.
Fire Fighting
Issued 15 May 1996
Resolved
Provide proof of service of all portable fire extinguishers aboard vessel by certified inspector.
Accommodation/Occupational Safety
Issued 24 September 1990
Resolved
INSTALL A TOILET AS REQUIRED BY 46 CFR 177.30-5
Documentation
Issued 24 September 1990
Resolved
OBTAIN PERMANENT STABILITY LETTER.
Documentation
Issued 14 January 1989
Resolved
PROVIDE U.S.COAST GUARD DOCUMENDTION IN ACCORDANCE WITH 46CFR PART 67
Engineering
Issued 4 November 1988
Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD ENGINE CONTROLS AND DEMONSTRATE PROPER OPERATION OF VESSEL'S REVERSE GEAR.VESSEL NOT TO BE OPERATED UNTIL THIS ITEM HAS BEEN CORRECTED TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Engineering
Issued 4 November 1988
Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD POWER TRIM TO THE SATISFACTIONOF COAST GUARD MARINE INSPECTOR. VESSEL NOT TO BE OPERATED UNTIL THIS ITEM CORRECTED.
Documentation
Issued 4 August 1987
Resolved
PROVIDE FCC STATION LICENSE FOR THE VESSEL.
Casualty record · 3
4 May 2010Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 3790437
23 April 2013Routine · role: Involved in a Marine Casualty · 1 dead · activity 4591771
28 February 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5076476
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.