Records from 1987 to 2025. Most recent: inspection, 1 December 2025.
- Built
- 1987
- Last inspected
- 1 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 117 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2016–2025
Identity
921176
WBQ3862
293310
Flag
UNITED STATES
367325220
Maury page id
psix-293310
Inspections, by type
…with no type recorded9
Years with a record
37 calendar years (1987–2025)
The 85 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.9 ft × 24.0 ft × 5.8 ft
Registered tonnagegross 46 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCAPTIVA ISLAND, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
31 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WBQ3862MMSI 367325220 · active · compulsorily equipped · granted 15 November 2017, expires 2 February 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 85
1 December 2025
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8269633
27 February 2025
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8086211
2 December 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8041791
5 September 2024
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7995301
8 September 2023
Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7769712
17 October 2022
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579201
4 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7573601
8 September 2022
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7554222
29 November 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7356403
7 December 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7101520
9 September 2020
Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7055193
7 January 2020
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6882658
1 November 2019
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6846995
7 January 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6602106
13 December 2018
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6597152
6 December 2018
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6593005
17 August 2018
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6514182
30 October 2017
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6297359
28 November 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6043565
27 October 2016
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6030698
7 September 2016
Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5975004
30 November 2015
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5758543
26 August 2014
Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4948071
13 February 2012
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4243494
3 January 2012
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4216106
24 January 2011
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3929134
8 September 2010
Hull Examination · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3835026
20 January 2010
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3660737
12 February 2009
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3411534
16 September 2008
Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3270345
14 January 2008
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3114225
9 February 2007
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2869209
26 September 2006
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2786964
8 February 2006
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2580892
14 February 2005
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2292044
31 January 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2284182
12 October 2004
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2211111
5 February 2004
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2018125
26 January 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1992608
17 March 2003
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1758315
14 February 2003
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1744696
14 January 2003
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1729930
18 September 2002
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1671919
5 March 2002
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1491764
5 February 2002
Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1483876
22 October 2001
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489468
7 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057876
16 January 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1439141
9 January 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1369962
14 September 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822802
31 July 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1051523
1 March 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1046485
20 January 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378993
14 June 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446788
29 April 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446787
20 July 1998
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1369001
25 June 1998
Examination of Repairs · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1369002
29 January 1997
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445174
28 May 1996
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1404272
2 April 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1443678
22 January 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 885225
16 March 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 857913
24 January 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 838788
7 July 1994
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1178234
28 February 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1164758
25 January 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 851882
8 March 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1149815
11 February 1993
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152100
11 December 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152097
12 March 1992
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 942977
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1000473
13 May 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 917558
30 January 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 927982
4 January 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 905550
26 October 1989
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1211339
10 October 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1026713
15 May 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1349695
26 September 1988
Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1044911
1 July 1988
Deficiency Check
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1207154
24 June 1988
Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 894007
17 December 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1311418
15 December 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314324
9 December 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1001316
19 November 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1308526
23 October 1987
Initial Certification · Hull Examination · Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1325923
Deficiency record · 117
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2023
Resolved
Equipment mounted on a hinged door of an enclosure must be constructed or shielded so that a person will not accidentally contact energized parts of the door mounted equipment when the door is open and the circuit energized.
Located on the interior of the vessel, main deck, aft of
the refreshment area, behind a wooden door, (2) Electrical breaker panels are missing the panel door covers. (1) Electrical breaker panel is missing two insulated blanks.
Replace the missing panel door covers and insulated blanks to the original manufacturer configuration of the electrical enclosures.
46 CFR 183.10-10(b)
46 CFR 183.330(h)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
46 CFR 176.665
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 January 2019
Resolved
Vessel's forward hydrant has pin hole leak.
Construction/Loadline › Hull › Stiffener
Issued 7 September 2016
Resolved
Port side stringer/channel wasted in way of tiller at steering compartment. Crop and renew wasted stringer in way of port side tiller.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016
Resolved
Hull wastage under sewage tank, starboard side between keel longitudinal, next to forward watertight bulkhead.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016
Resolved
Engine room, observed hull plating near the port shaft wasted, as well as, port side bulkhead in way of chase way.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016
Resolved
Storage/center void, observed hull/frame wastage under plywood decking and at hull plate around through hull.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016
Resolved
Forepeak, observed wasted stringer and hull plate.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016
Resolved
Observed heavy wastage to complete circumference of port/starboard engine/generator exhaust hull penetrations.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 September 2014
Resolved
Provide onboard ampmeter for newly installed generator and show proper operation to the attending marine inspector at next annaul inspection.
Construction/Loadline › Structures › End Bulkhead
Issued 26 August 2014
Resolved
Crop and renew section of bulkhead in the #2 bulkhead 1' to 2' stbd of the keel.
Construction/Loadline › Hull › Bottom Plating
Issued 26 August 2014
Resolved
De-scale the identified frame bays and make available for inspection
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 26 August 2014
Resolved
Replace 2" sewage overboard valve with new one.
Construction/Loadline › Structures › Scuttle
Issued 26 August 2014
Resolved
Replace fwd compartment deck scuttle sealing ring with new one.
Engineering › Bilge Water Management System › Piping
Issued 3 January 2012
Resolved
Replace flexible hoses in the bilge manifold connection to the bilge pump and coolant supply hose to the generator IAW 46 CFR 182.20-40 (ii).
Engineering › Fuel Oil Service System › Hose
Issued 3 January 2012
Resolved
Repair fuel oil leaks in the fill line and supply line to the generator IAW 46 CFR 182.20-40 (a).
Fire Fighting › Fire Pumps › Pressure
Issued 3 January 2012
Resolved
Replace gauge on the firemain IAW 46 CFR 181.10-1(c).
Construction/Loadline › Structures › Door
Issued 3 January 2012
Resolved
Repair the watertight door leading to the aft deck IAW 46 CFR 171.124.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 January 2011
Resolved
Paint running lights frames black matt in color.
Construction/Loadline › Structures › Superstructure
Issued 24 January 2011
Resolved
Make permanent repairs to port navigation light mounts, step leading into the pilothouse and forward watertight door.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2011
Resolved
Replace expired ammonia inhalants in the first aid kit.
Lifesaving › Lifefloat › Lifeline
Issued 24 January 2011
Resolved
Install or demonstrate lifefloats painters are of sufficent length IAW 46 CFR 180.130(a)(4) to deploy overboard.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 January 2010
Resolved
Have current charts of applicable routes on board the vessel.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 January 2010
Resolved
Install keeper chain for hatch behind the bar.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 12 February 2009
Resolved
Re-install structural fire protection in engine space.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 February 2009
Resolved
Re-install exhaust lagging on port engine.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 February 2009
Resolved
Re-install exhaust lagging starboard side sewage compartment.
Engineering › Fuel Oil Service System › Valve
Issued 12 February 2009
Resolved
Adjust fuel shut off cables.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 January 2008
Resolved
Replace navigation pubs.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 January 2008
Resolved
Update emergency instruction
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 January 2008
Resolved
Install machinery guards in E/R.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 31 January 2005
Resolved
PROVIDE WRITTEN SMI POLICY FOR DRUG TESTING PROGRAM.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 31 January 2005
Resolved
PROVIDE CONSCISE DESCRIPTION OF EMERGENCY DRILLS IN TRAINING LOGBOOK.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 31 January 2005
Resolved
PROVIDE CONCISE DESCRIPTION OF LIFESAVING EQUIPMENT MAINTAINENCE IN VESSEL LOGBOOK.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 31 January 2005
Resolved
ENTER MONTHLY EPIRB TEST IN VESSEL LOGBOOK.
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2005
Resolved
SUBMIT A REPAIR PROPOSAL FOR WASTED MAIN DECK UNDER FORWARD BAR SINK.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 31 January 2005
Resolved
PROVIDE 7 ADDITIONAL ADULT TYPE I PFD'S ONBOARD VESSEL. VESSEL IS RESTRICTED TO CARRYING A TOTAL OF 141 PASSENGERS UNTIL CORRECTED.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 January 2005
Resolved
RENEW ASPIRIN AND EYE WASH IN FIRST AID KIT.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 31 January 2005
Resolved
STRAP DOWN /SECURE THE FROZEN DRINK MACHINE ON MAIN DECK FORWARD BAR.
Construction/Loadline › Structures › Manhole
Issued 1 October 2004
Resolved
Forward void hatch (forward of refreshment stand/bar, inside enclosed passenger cabin), approximately 5 inch fracture along edge, compromising watertight integrity. Repair or replace.
Electrical › Electric Supply System (service)
Issued 26 January 2004
Resolved
Replace wing nuts on battery terminals with hex nuts. LEGACY COMPONENT DESC: Battery Conductor
Electrical › Electrical Distribution System (service)
Issued 26 January 2004
Resolved
Properly support wiring in engine room. LEGACY COMPONENT DESC: Conductor
Engineering › Freshwater System (air cooling)
Issued 26 January 2004
Resolved
Bolt AC raw water pump to deck. LEGACY COMPONENT DESC: Pump
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 January 2004
Resolved
Replace 41 adult PFDs and 8 child PFDs. Vessel is restricted to 120 adults and 6 children until PFDs are replaced. LEGACY COMPONENT DESC: Condition
Operations/Management › Drug and Alcohol Testing
Issued 14 January 2003
Resolved
Provide negative test result records for 26 tests as listed on MIS form. Provide current contract for EAP program, post company policy, post EAP information, provide evidence that lab is DHHS certified, provide current letter for MRO designation. LEGACY COMPONENT DESC: Recordkeeping
Electrical › Electric Supply System (service)
Issued 14 January 2003
Resolved
Remove unused wiring from overhead in "soda" void. LEGACY COMPONENT DESC: Cable
Documentation › Markings/Placards › Garbage Placard
Issued 14 January 2003
Resolved
Provide MARPOL V placard.
Construction/Loadline › Penetrations
Issued 14 January 2003
Resolved
Cap off pipe at sideshell penetration, starboard side of AC void. LEGACY COMPONENT DESC: Pipe Flange
Construction/Loadline › Hull
Issued 14 January 2003
Resolved
Weld inside of doubler plates on port and starboard wastage plates for exhaust penetrations. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Structures
Issued 14 January 2003
Resolved
Replace gasket on watertight hatch for sewage tank void. LEGACY COMPONENT DESC: Manhole
Communications › Alarms/Indicators
Issued 14 January 2003
Resolved
Re-mount high water bilge alarm under sewage tank. LEGACY COMPONENT DESC: High Water Alarm
Navigation › Collision/Grounding Avoidance
Issued 14 January 2003
Resolved
Clean lenses for navigation lights and ensure lights provide correct lumination. LEGACY COMPONENT DESC: Navigation Lights
Documentation › Markings/Placards
Issued 14 January 2003
Resolved
Display additional lifejacket donning procedures.
Fire Fighting › Means of Escape
Issued 14 January 2003
Resolved
Label emergency escape from main passenger cabin. LEGACY COMPONENT DESC: Escape Route Signs
Lifesaving › Lifebuoys
Issued 14 January 2003
Resolved
Provide proper u/v resistant floating line for ringlife buoy and light. LEGACY COMPONENT DESC: Buoyant Lifeline
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 January 2003
Resolved
Provide 4 adult type I PFDs - vessel restricted to to carrying 144 passengers. LEGACY COMPONENT DESC: Condition
Lifesaving › Buoyant Apparatus
Issued 14 January 2003
Resolved
Remove wireties from lifefloat paddles.
Lifesaving › Buoyant Apparatus
Issued 14 January 2003
Resolved
Provide proper u/v resistant floating line for lifefloat lights.
Electrical › Electric Supply System (service)
Issued 14 January 2003
Resolved
Clean battery terminals. LEGACY COMPONENT DESC: Battery Conductor
Engineering › Fuel Oil Service System
Issued 14 January 2003
Resolved
Provide proper J 1942 hoses and fittings for generator fuel system. LEGACY COMPONENT DESC: Piping
Electrical › Electric Supply System (service)
Issued 14 January 2003
Resolved
Properly support electrical cables throughout vessel. LEGACY COMPONENT DESC: Cable
Stability › Weathertight Integrity
Issued 14 January 2003
Resolved
Provide gasket for forward weathertight door on main deck.
Construction/Loadline › Penetrations
Issued 5 September 2002
Resolved
RENEW ALL 3 EXHAUST PIPE PENETRATIONS AFT. LEGACY COMPONENT DESC: Weld
Engineering › Steering Gear System
Issued 5 September 2002
Resolved
DOUBLE NUT OR LOCK NUT QUADRANT TO RUDDER STOCK CONNECTION PORT AND STARBOARD SIDE. LEGACY COMPONENT DESC: Fastener
Construction/Loadline › Penetrations
Issued 5 September 2002
Resolved
RENEW AND SEAL LEAKING PORT RUB RAIL BOLTS IN WAY OF
#3 HOLD.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 5 September 2002
Resolved
RENEW BOTH WASTED WINDOW FRAMES IN WAY OF MAIN DECK PASSENGER SPACE.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 September 2002
Resolved
PROPERLY MOUNT SODA PUMP AND HARDWIRE POWER SUPPLY IN #2 HOLD.
Engineering › Bilge Water Management System
Issued 5 September 2002
Resolved
REMOVE/BLANK OFF UNUSED OVERBOARD PIPE IN #2 HOLD. LEGACY COMPONENT DESC: Piping
Construction/Loadline › Penetrations
Issued 5 September 2002
Resolved
RENEW MISSING RUB RAIL BOLT STARBOARD SIDE ENGINE ROOM.
Electrical › Electrical Distribution System (service)
Issued 5 September 2002
Resolved
PROPERLY SUPPORT WIRE RUNS PORT SIDE ENGINE ROOM SIDESHELL. LEGACY COMPONENT DESC: Wiring
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 September 2002
Resolved
RENEW NINE (9) CONDEMNED TYPE I PFD'S. LEGACY COMPONENT DESC: Condition
Fire Fighting › Fire Pumps
Issued 5 February 2002
Resolved
BRING VESSELS FIRE PUMP INTO COMPLIANCE WITH 46CFR181.10-1(b) OLD T. FIRE PUMP IS TO BE SELFPRIMING AND OF SUCH SIZE AS TO DISCHARGE AN EFFECTIVE STREAM FROM A HOSE CONNECTED TO THE HIGHEST OUTLET. PRESENT PUMP DOES NOT PRODUCE AN EFFECTIVE STREAM TO FIGHT A FIRE. LEGACY COMPONENT DESC: Capacity
Electrical › Lighting (service)
Issued 4 February 2002
Resolved
INSTALL GUARDS AROUND GLASS GLOBES FOR LIGHTS IN A/C VOID AND VOID UNDER GALLEY AS POINTED OUT BY CG MARINE INSPECTOR. LEGACY COMPONENT DESC: Lighting Fixture
Accommodation/Occupational Safety › Occupational Safety
Issued 4 February 2002
Resolved
PROPERLY MOUNT COFFEE MAKER AND INSTALL GUARDS AROUND WARMER PLATE TO PREVENT POTS FROM FALLING. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Electrical › Electric Supply System (service)
Issued 4 February 2002
Resolved
PROPERLY MOUNT BATTERY BOXES TO PREVENT SHIFTING. LEGACY COMPONENT DESC: Battery Installation
Construction/Loadline › Hull
Issued 4 February 2002
Resolved
REPAIR HOLES IN SIDE SHELL PORT SIDE AFT VOID AS INDICATED BY CG MARINE INSPECTOR. LEGACY COMPONENT DESC: Side Shell
Lifesaving
Issued 9 January 2001
Resolved
PROVIDE CONTENTS LIST FOR FIRST AID KIT.
Lifesaving
Issued 9 January 2001
Resolved
MARK ALL LIFEFLOAT PADDLES WITH VESSEL'S NAME.
Lifesaving
Issued 9 January 2001
Resolved
REPAIR/REPLACE ALL LIFEFLOATS DUE TO WORN.
Accommodation/Occupational Safety
Issued 9 January 2001
Resolved
PROVIDE PROOF THAT ALL WASTE RECEPTICLES ARE NON-FLAMMABLE.
Lifesaving
Issued 9 January 2001
Resolved
REPLACE 36 ADULT PFD'S.
Accommodation/Occupational Safety
Issued 9 January 2001
Resolved
MOUNT COFFEE MAKER AND MICROWAVE TO PREVENT MOVEMENT,
Documentation
Issued 20 January 2000
Resolved
PROVIDE AND POST COPY OF RENEWED FCC CERTIFICATE.
Engineering
Issued 20 January 2000
Resolved
INSTALL PROTECTIVE GUARD ON BACKSIDE OF PULLEY ON STBD MAIN ENGINE.
Electrical
Issued 20 January 2000
Resolved
MOUNT BATTERY BOXES TO PREVENT MOVEMENT AND INSTALL WOOD BLOCKING AS NEEDED.
Documentation
Issued 20 January 2000
Resolved
PROVIDE AND POST LEGIBLE STABILITY LETTER.
Electrical
Issued 20 January 2000
Resolved
INSTALL COVERS OR DRIPSHIELDS ON PANEL BOXES IN WET LOCATIONS AND ON RECEPTICLES INWAY OF SINKS.
Electrical
Issued 20 January 2000
Resolved
REMOVE NON-MARINE CHRISTMAS LIGHTS OR PROPERLY INSTALL TO MAKE WATERTIGHT AND HARDWIRE SAME.
Lifesaving
Issued 20 January 2000
Resolved
PROVIDE RESCUE LADDER WITH PLATFORM FOR MAN-OVERBOARD RESCUE.
Lifesaving
Issued 29 April 1999
Resolved
RENEW 3 RED FLARES PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 April 1999
Resolved
RELOCATED ORANGE RING BUOY TO VICINITY OF WHEELHOUSE. ATTACH WATERLIGHT AND60' LINE._x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 January 1997
Resolved
PROVIDE 3 ADDITIONAL ORANGE AND 3 ADDITIONAL RED FLARES PRIOR TO OPERATING COASTWISE.
Lifesaving
Issued 29 January 1997
Resolved
REPAIR INOPERABLE STROBE FOR LIFEFLOAT._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 January 1997
Resolved
PROVIDE EMERGENCY BROADCAST INSTRUCTIONS._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 29 January 1997
Resolved
RENEW CRACKED WINDOW GLASS IN WHEELHOUSE._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 January 1997
Resolved
REPAINT RING BUOY INTERNATIONAL ORANGE, RELABEL WITH VESSEL NAME._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 January 1997
Resolved
PROVIDE 406 MHZ EPIRB W/FLOAT FREE CAPABILITY._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 January 1997
Resolved
PAINT FLARE CONTAINER BRIGHT COLOR, LABEL "DISTRESS SIGNALS"._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 22 January 1996
Resolved
LABEL CHILD AND ADULT PFD STOWAGE IN OVERHEAD.
Accommodation/Occupational Safety
Issued 22 January 1996
Resolved
LABEL UPPER DECK "70 PERSONS MAXIMUM"._x001C_
Lifesaving
Issued 22 January 1996
Resolved
PROVIDE 6 RED FLARES WITH CURRENT DATES PRIOR TO OPERATING.
Lifesaving
Issued 22 January 1996
Resolved
REPAIR OR REPAINT FOUR LIFEFLOATS AND RENEW ALL PADDLES.
Accommodation/Occupational Safety
Issued 24 January 1995
Resolved
Renew both aft lower window frames on the wheelhouse.
Lifesaving
Issued 24 January 1995
Resolved
Stencil vessel name and capacity of each on 4 lifefloats.
Documentation
Issued 24 January 1995
Resolved
Provid FCC Safety Radiotelephonyt certifcate. Vessel's route is restrictedto not more than 1000' feet from shore until complete.
Construction/Loadline
Issued 25 January 1994
Resolved
Renew wasted bilge strainers.
Lifesaving
Issued 25 January 1994
Resolved
Renew all 6 orange smoke flares.
Fire Fighting
Issued 25 January 1994
Resolved
Repair bearings en elctrical fire pump.
Electrical
Issued 25 January 1994
Resolved
Repair exhaust fan for engineroom.
Construction/Loadline
Issued 25 January 1994
Resolved
Install one additional vent in steering gear & sewage tank compartments.
Lifesaving
Issued 25 January 1994
Resolved
Renew lifelines and painters on all 4 lifefloats.
Navigation
Issued 11 February 1993
Resolved
Have adjustment performed on magnetic compass.
Electrical
Issued 12 March 1992
Resolved
Rewire electrical shore tie cable to junction box using U.L. approved mainetype box connectors.
Lifesaving
Issued 12 March 1992
Resolved
Remove all lifefloats from stowage brackets, clean thoroughly, renew lifelines and paddles as required.
Lifesaving
Issued 24 June 1988
Resolved
TOTAL PERSONS ALLOWED REDUCED TO 145 UNTIL 15 ADDITIONAL ADULT PFD,S ARE PROVIDED
Construction/Loadline
Issued 23 October 1987
Resolved
COMPLETE INSTALLATION OF ENGINE ROOM VENTILATION DUCTING.
Navigation
Issued 23 October 1987
Resolved
ROVIDE 6 HAND RED FLARES AND 6 HAND ORANGE SMOKE OR 12 HAND COMBINATION FLARE AND SMOKE DISTRESS SIGNALS AND STOWED IN A PORTABLE WATERTIGHT CONTAINER.
Casualty record · 5
27 October 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6030698
13 December 2018Routine · role: Involved in a Marine Casualty · activity 6597152
1 November 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6846995
17 October 2022Routine · role: Involved in a Marine Casualty · activity 7579201
27 February 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8086211
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.