MAURY USCG vessel records
← All vessels

LADY CHADWICK

Built
1987
Last inspected
1 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 December 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBQ3862
293310
Flag
UNITED STATES
Maury page id
psix-293310

Documentation record

Registered dimensions (L × B × D)61.9 ft × 24.0 ft × 5.8 ft
Registered tonnagegross 46 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LA CROSSE, WI, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCAPTIVA ISLAND, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

1 December 2025 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8269633
27 February 2025 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8086211
2 December 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8041791
5 September 2024 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7995301
8 September 2023 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7769712
17 October 2022 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579201
4 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7573601
8 September 2022 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7554222
29 November 2021 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7356403
7 December 2020 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7101520
9 September 2020 Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7055193
7 January 2020 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6882658
1 November 2019 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6846995
7 January 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6602106
13 December 2018 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6597152
6 December 2018 Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6593005
17 August 2018 Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6514182
30 October 2017 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6297359
28 November 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6043565
27 October 2016 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6030698
7 September 2016 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5975004

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2023 Resolved
Equipment mounted on a hinged door of an enclosure must be constructed or shielded so that a person will not accidentally contact energized parts of the door mounted equipment when the door is open and the circuit energized. Located on the interior of the vessel, main deck, aft of the refreshment area, behind a wooden door, (2) Electrical breaker panels are missing the panel door covers. (1) Electrical breaker panel is missing two insulated blanks. Replace the missing panel door covers and insulated blanks to the original manufacturer configuration of the electrical enclosures. 46 CFR 183.10-10(b) 46 CFR 183.330(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2023
Resolved 14 September 2023
Resolution: (2) New electrical panel door covers were installed, complete with sufficient insulated blanks.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022 Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector. 46 CFR 176.665
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 May 2023
Resolution: Underway sea trials were conducted and vessel determined fir for service.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 January 2019 Resolved
Vessel's forward hydrant has pin hole leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2019
Resolved 8 January 2019
Resolution: Threaded new piece of pipe where leak was.
Construction/Loadline › Hull › Stiffener
Issued 7 September 2016 Resolved
Port side stringer/channel wasted in way of tiller at steering compartment. Crop and renew wasted stringer in way of port side tiller.
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: Replaced stringer.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016 Resolved
Hull wastage under sewage tank, starboard side between keel longitudinal, next to forward watertight bulkhead.
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: Examined welds, witnessed satisfactory airtest of plate insert.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016 Resolved
Engine room, observed hull plating near the port shaft wasted, as well as, port side bulkhead in way of chase way.
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: Examined welds, witnessed satisfactory air test of plate insert.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016 Resolved
Storage/center void, observed hull/frame wastage under plywood decking and at hull plate around through hull.
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: Examined welds, witnessed satisfactory air test of plate insert.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016 Resolved
Forepeak, observed wasted stringer and hull plate.
Action required: 705 - Other - as specified
Resolved 23 September 2016
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2016 Resolved
Observed heavy wastage to complete circumference of port/starboard engine/generator exhaust hull penetrations.
Action required: 705 - Other - as specified
Resolved 3 October 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.