AIDA is a 1960 freight ship. The Coast Guard has recorded 12 inspections since 1987, most recently in June 1993, along with 20 deficiencies and 1 operational control.

Records from 1987 to 1993. Most recent: inspection, 30 June 1993.

Built
1960
Last inspected
30 June 1993
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5141718 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
293351
Flag
HONDURAS
—
Maury page id
psix-293351

Inspections, by type

…with no type recorded12
Years with a record 4 calendar years (1987–1993)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it131 - Regulatory (Subpart C or D), Net Ton
285 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

30 June 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 652575
4 May 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 358097
13 November 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 531326
19 October 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 676689
17 September 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 492810
19 August 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 511196
12 August 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 443225
25 February 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 343198
25 February 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 343241
4 November 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 326991
13 December 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 320236
26 October 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 319359

Deficiency record · 20

Documentation
Issued 4 May 1993 Resolved
A violation of 46 CFR 42.07-5 in that the vessel did not have a valid loadline as required by CFR 42.07-45(b). Vessel subject to U.S. regulationsper 46 CFR 2.01-13(b).
Condition: Unknown
Due 20 June 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 May 1993 Resolved
A violation of 46 CFR 42.15-10(a) in that the superstructure could not be made weathertight due to the position of the padlocks on the doors. Vessel subject to U.S. regulations per 46 CFR 2.01-13(b).
Condition: Unknown
Due 20 June 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 4 May 1993 Resolved
Vessel had "PROPANE" compressed gas cylinders which is a flammable gas under table 101 of 49 C.F.R. not labeled as such.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Lifesaving
Issued 4 May 1993 Resolved
Lights need covers and all electrical wiring needs to be made permanent.
Condition: Unknown
Due 17 May 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 4 May 1993 Resolved
A violation of 46 CFR 42.07-60(f) in that the loadline of the vessel did not correspond to the markings on the loadline certificate. Vessel subject to U.S. regulations per 46 CFR 2.01-13(b)
Condition: Unknown
Due 6 May 1993
Resolved 16 June 1993
Deck/Cargo
Issued 25 February 1991 Resolved
A VIOLATION OF ILO 147 IN THAT THE VESSEL FAILED TO MAINTIAN THE ANCHOR STATIONS CLEAR AND FREE FROM GENERAL CARGO._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Construction/Loadline
Issued 25 February 1991 Resolved
A VIOLATION OF 46 CFR 42.13-40 (A) IN THAT THE VESSEL'S LOADLINE LETTERS WAS NON CONTRASTING TO THE VESSEL'S HULL. THE LOADLINE LETTERS WERE PAINTEDBLACK WHICH WAS THE SAME COLOR OF THE VESSELS HULL._x001C_ _x001C_
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Construction/Loadline
Issued 25 February 1991 Resolved
VEESEL FOUND IN VIOLATION OF 46CFR42.13-40 DUE TO LOADLINE MARKS NOT _x001C_ PERMANENT TO HULL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Electrical
Issued 25 February 1991 Resolved
VESSEL FOUND IN VIOLATION OF ILO-147 DUE TO NO RUBBER MATTING FOR ELECTRICAL PANEL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 25 February 1991 Resolved
VESSEL FOUND IN VIOLATION OF ILO-147 DUE TO FAULTY LIGHTING IN ENGINROOM_x001C_ AND ANCHOR ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 25 February 1991 Resolved
VESSEL FOUND IN VIOLATION OF ILO-147 DUE TO DOORS ON MAIN DECK NEED TO BE _x001C_FIXED AND MADE WATERTIGHT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 25 February 1991 Resolved
VESSEL FOUND IN VIOLATION OF 46CFR25.30 DUE TO FIRE EXTINGUISHERS NEED RECHARGED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Deck/Cargo
Issued 25 February 1991 Resolved
VESSEL FOUND IN VIOLATION OF ILO-147 DUE TO CARGO IN FOREPEAK TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Accommodation/Occupational Safety
Issued 25 February 1991 Resolved
VESSEL FOUND IN VIOLATIION OF ILO-147 DUE TO HOSE ON GAS STOVE IS IN_x001C_ NEED OF REPAIR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Documentation
Issued 25 February 1991 Resolved
VESSEL FOUND IN VIOLATION OF 33CFR160.113 DUE TO MARKS ON FUEL DRUMS NOT _x001C_ PROPERLY LABELED,NOR HAS NO DUNNAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 October 1991
Resolved 30 October 1991
Documentation
Issued 4 November 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Construction/Loadline
Issued 4 November 1988 Resolved
VSL'S LOADLINE WAS SUBMERGED APPROXIMATELY 4-6 INCHES. WHILE LOADLINE WAS SUBMERGED VSL CONTINUED TO LOAD. MSO I.O.'S DID A LOADLINE INSPECTION REPORT ON VSL. MASTER [name withheld] STATED THAT HE PLANNED TO PUMP OUT HIS BALLAST TANKS WHEN VSL WAS FINISHED LOADING.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Accommodation/Occupational Safety
Issued 4 November 1988 Resolved
VSL HAS TWO TOILET FACILITIES BUT ONLY ONE IS HOOKED TO THE MSD. MASTER [name withheld] STATED THE REMAINING TOILET WAS NOT HOOKED UP DUE TO EXCESSIVE COST. MASTER ALSO STATED TOILET WAS LOCKED AT ALL TIMES.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Accommodation/Occupational Safety
Issued 26 October 1987 Resolved
VESSEL FAILED TO HAVE AN APPROVED TYPE II OR TYPE III MSD INSTALLED. VESSEL'S MSD WAS OVERBOARD DISCHARGE TYPE
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987
Engineering
Issued 26 October 1987 Resolved
VESSEL FAILED TO HAVE PIPING AND DISCHARGE CONNECTION AS REQUIRED BY 33 CFR155.420.
Condition: Unknown
Due 26 October 1987
Resolved 26 October 1987

Ownership record