MAURY USCG vessel records Sign in
← All vessels

SPRING BREEZE 1

SPRING BREEZE 1 is a 1984 freight ship. The Coast Guard has recorded 34 inspections since 1987, most recently in September 2010, along with 41 deficiencies and 5 operational controls.

Records from 1987 to 2010. Most recent: inspection, 17 September 2010.

Built
1984
Last inspected
17 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8026139 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
293383
Flag
PANAMA
—
Maury page id
psix-293383

Inspections, by type

…with no type recorded26
Years with a record 14 calendar years (1987–2010)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9293 - Convention (Subpart B), Net Ton
34125 - Displacement, Ton
26710 - Dead Weight, Ton
16829 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

17 September 2010 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3851946
10 September 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3846979
21 January 2008 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3133926
20 January 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3133546
25 September 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3065897
20 September 2007 ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3062003
12 May 2007 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2925186
10 May 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2926647
28 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2250292
28 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2307439
24 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2247850
23 November 2004 Loadline Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ILO-147 Exam · ISM Exam · Ballast Water Examination · STCW 95 Exam · PII Safety Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2247016
18 November 2004 ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2245842
25 July 2003 Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1856948
22 July 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1854627
22 July 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1859870
14 July 2003 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1847200
30 June 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 279009
18 June 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 31861
12 June 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 278757
20 December 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 97280
14 December 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 435451
10 December 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 85294
1 December 1999 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 517013
23 November 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 434837
22 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 390159
21 July 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 652591
19 July 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 368575
6 November 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 362178
3 November 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 362321
11 September 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 345881
20 February 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 328600
23 June 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 514125
2 November 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 319381

Deficiency record · 41

Engineering › Steering Gear System › Rudder
Issued 22 January 2008 Resolved
While testing the No. 2 steering pump the rudder stopped at 10 degrees port and 22 degrees starboard and did not go any farther. The rudder did go to 35 degrees starboard and port while running the No.1 steering gear pump.
Due 22 January 2008
Resolved 22 January 2008
Resolution: The Chief Engineer bled air out of the system and a test was conducted in all modes to the satisfaction of the attending Coast Guard marine inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 September 2007 Resolved
The medicine stores for the vessel hospital are depleted. The vessel does not have the adequate items to provide general first aid as outlined in its ISM. This was confirmed and issued as non conformity by vessel superintendent. Re-supply hospital so that vessel is in compliance with ISM requirements. Make arrangements to the satisfaction of the administration.
Due 27 September 2007
Resolved 24 September 2007
Resolution: Received class report from American Bureau of Shipping stating that adequate medicine stores have been provided for the vessel.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 May 2007 Resolved
[name withheld] reported that the LCD screen on the VHF radio is not clearly readable. During the bridge exam, the PSCO witnessed the technician repairing the radio. Provide technician's report to COTP [name withheld] attesting to satisfactory operation of the VHF.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 12 May 2007
Resolution: Received technicians report, stating that the VHF has been repaired and tested and is now in good working condition.
Accommodation/Occupational Safety › Potable Water System
Issued 25 July 2003 Resolved
Hot Water Tanks in galley are inoperable. The galley does not have hot running water. LEGACY COMPONENT DESC: Hot Water Heater
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 28 July 2003
Resolution: Received a copy of the delivery receipt of the newly supplied hot water heater and a telex from the captain stating the old hot water heater was removed and the new one was insatalled in working order.
Electrical › Lighting (service)
Issued 14 July 2003 Resolved
Naked wiring outside galley on overhead.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2003
Resolved 15 July 2003
Resolution: Naked wiring was made secure.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 July 2003 Resolved
Main deck railing on port side midships was found to be broken. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 14 August 2003
Resolved 15 July 2003
Resolution: Vessel welded and made proper repairs to Deck Hand Rail.
Engineering › Fuel Oil Service System
Issued 14 July 2003 Resolved
All three heavy fuel oil and diesel oil purifiers are in need of repair. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2003
Resolved 18 July 2003
Resolution: Class report from ABS States NO2 HFO Purifier was repaired tested and considered satisfactory.
Pollution Prevention/Response › Prevention Equipment
Issued 14 July 2003 Resolved
The plug for the F/O vent containment was seized due to excessive rust. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Improper/Lack of Maintenance
Due 14 July 2003
Resolved 15 July 2003
Resolution: Plug was unseized and lubed for easy operation.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 14 July 2003 Resolved
Sewage overboard piping and pipes before and after MSD in engine room are holed and leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2003
Resolved 18 July 2003
Resolution: Class report from ABS states that sewage overboard pipe complete and repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2003 Resolved
The inlet and outlet pipe for diesel oil coolers for generators #2 and #3 have holes and are leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS states inlet/outlet piping on diesel oil coolers on generators No 2 & 3 were repaired tested and considered satisfactory.
Electrical › Lighting (emergency)
Issued 14 July 2003 Resolved
Missing light bulbs in the engine room escape trunk. LEGACY COMPONENT DESC: Missing light bulbs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: blown lights in the engine room escape trunk were found to be replaced and in good working order By USCG Marine Inspector [name withheld] and [name withheld].
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 July 2003 Resolved
Fresh Water inlet pipe for OWS holed and leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS States Fresh water hose for ows has been repaired and considered Satisfactory.
Engineering › Sea-water System (primary cooling)
Issued 14 July 2003 Resolved
Main Engine Sea water cooling inlet & outlet piping holed and leaking. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS States Main Engine air cooling sea water inlet piping cleaned repaired and considered opearable for continus use.
Engineering › Sea-water System (primary cooling)
Issued 14 July 2003 Resolved
S/W inlet pipe for piston water cooler for M/E has holes and leaks. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS States that main engine piston water cooler sea water inlet/outlet leakes completely repaired.
Engineering › Sea-water System (primary cooling)
Issued 14 July 2003 Resolved
Main S/W pipe overboard and fresh water evaporator return piping holed and leaking. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS States that Evaporator inlet condenser salt water pipe (bracket Temporarly repaired.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 14 July 2003 Resolved
#2 generator fuel oil pump #3 is leaking. LEGACY COMPONENT DESC: F/O pump
Condition: Improper/Lack of Maintenance
Due 14 August 2003
Resolved 15 July 2003
Resolution: #2 and #3 genarator fuel oil pump was repaired and cleared by USCG Marine Inspector [name withheld] and [name withheld].
Engineering › Generator (propulsion-electric) › Receptacle
Issued 14 July 2003 Resolved
All three generators fuel oil drain lines are missing or needs to be reattached.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 25 July 2004
Resolution: Received Class report of repairs.
Engineering › Freshwater System (cylinder head cooling)
Issued 14 July 2003 Resolved
The no flow indicator on #3 Cylinder of the main engine piston cooling was found to be disconnected. LEGACY COMPONENT DESC: Main engine piston cooloing indicator
Condition: Improper/Lack of Maintenance
Due 14 August 2003
Resolved 15 July 2003
Resolution: The no flow inicator on #3 cylinder for the M/E piston cooling was repaired and cleared by USCG Marine Inspector [name withheld] and [name withheld].
Engineering › Fuel Oil Service System › Heater
Issued 14 July 2003 Resolved
F/O heating pipe above saltwater jacket cooling valve has soft patch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS states F/O heating pipe above saltwater jacket cooling valve was renewed tested and considered satisfactory.
Fire Fighting › Miscellaneous Items
Issued 14 July 2003 Resolved
A wood panel was used on the ceiling instead of proper fire resitant panels. Solas 74unamended CH2/reg 51 (b) (c) LEGACY COMPONENT DESC: ceiling tile
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2003
Resolved 15 July 2003
Resolution: Panel was replaced and deficiency was cleared by Marine Inspector [name withheld] and [name withheld]
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2003 Resolved
Replace packing in aft sea water tank valve in shaft alley.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2003
Resolved 18 July 2003
Resolution: Class report from ABS states packing on aft peak tank valve in shaft alley was renwewed..
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 14 July 2003 Resolved
Replace all oil soaked and missing insulation in way of lube oil manifold next to lube oil purifier, heavy fuel oil manifold, boiler hot well tank on engine room lower level and on fuel oil return line for main engine. LEGACY COMPONENT DESC: Insulation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 25 July 2004
Resolution: Received Class report of repairs.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 July 2003 Resolved
Repair hole in deck below Fresh Water Hydrophor. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2003
Resolved 18 July 2003
Resolution: Class report from ABS States Engine Room 01 deck frame 22-23 doubler has been installed.
Engineering › Freshwater System (cylinder head cooling)
Issued 14 July 2003 Resolved
Main engine jacket water piping outlet pipe for cooler is holed and leaking. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS States Main engine jacket water cooler saltwater outlet leakes have been completly repaired.
Engineering › Sea-water System (primary cooling)
Issued 14 July 2003 Resolved
Salt Water outlet for M/E lube oil cooler holed and leaking. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 18 July 2003
Resolution: Class report from ABS States that main engine lube oil cooler saltwater outlet leakes completly repaired.
Accommodation/Occupational Safety
Issued 30 June 2000 Resolved
PRIOR TO THE DEPARTURE OF THIS U.S. PORT, PROVIDE FUMIGATION OF GALLEY AND AJOINING AREAS BY EXTERMINATION CONTRACTOR.
Condition: Unknown
Due 30 June 2000
Resolved 26 November 2000
Documentation
Issued 30 June 2000 Resolved
PRIOR TO THE DEPARTURE OF THIS U.S. PORT PROVIDE TO THE SATISFACTION OF ATTENDING INSPECTOR, A COPY OF OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 30 June 2000
Resolved 26 November 2000
Fire Fighting
Issued 12 June 2000 Resolved
FORWARD FIRE HYDRANT ON PORT SIDE IS BROKE. REPAIR OR RENEW AND PROVIDE CLASS REPORT PRIOR TO 13JUN00.
Condition: Unknown
Due 13 June 2000
Resolved 14 July 2003
Resolution: Tested fire system and inspected all fire hydrants found in satisfactory condition.
Lifesaving
Issued 12 June 2000 Resolved
DAMAGE TO LIFEBOAT IN NOVEMBER, 99 HAS NO DOCUMENTATION FOR ISM. PROVIDE DOCUMENTATION FROM COMPANY THAT NON CONFORMITY WAS REPORTED PRIOR TO RETURNTO U.S. OR HAVE A FULL ISM AUDIT CONDUCTED BY FLAG STATE.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Documentation
Issued 12 June 2000 Resolved
BOSN HAS NO CURRENT STCW LICENCE. PROVIDE DOCUMENTATION PRIOR TO RETURN U.S.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Lifesaving
Issued 12 June 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 June 2000
Resolved 16 June 2000
Lifesaving
Issued 12 June 2000 Resolved
REPAIR TO HULL OF PORT LIFEBOAT, WATER IN WATER TIGHT COMPARTMENT. PROVIDEDOCUMENTATION FROM CLASS THAT REPAIR IS MADE AND ALL WATERTIGHT BY 12JUL00,AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 12 July 2000
Resolved 16 June 2000
Navigation
Issued 12 June 2000 Resolved
OIL COMING FROM SOLONOID ON STBD STEERING MOTOR. REPAIR OR RENEW AND PROVIDE CLASS REPORT BY 13JUN00.
Condition: Unknown
Due 13 June 2000
Resolved 16 June 2000
Accommodation/Occupational Safety
Issued 23 November 1999 Resolved
Sewage system not operational. 2 holding tanks of 20 cubic meters to be used.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Deck/Cargo
Issued 23 November 1999 Resolved
Cranes/holds on main deck leaking hydraulic oil.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Navigation
Issued 19 July 1994 Resolved
THE VESSEL TRANSITED THE COLUMBIA AND WILLAMETTE RIVERS WITH AN INOPERABLE ECHO DEPTH SOUNDING DEVICE.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Navigation
Issued 19 July 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Fire Fighting
Issued 3 November 1993 Resolved
REPLACE GASKETS IN ALL FIRE HOSES AND FIRE STATIONS, AS PER SOLAS REGULATION 51. PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 November 1993
Resolved 10 November 1993
Fire Fighting
Issued 3 November 1993 Resolved
INSTALL FIRE HOSES, NOZELS AND COUPLINGS IN ALL FIRE STATIONS AS PER SOLAS REGULATION 51 PRIOR TO DEPATURE.
Condition: Unknown
Due 3 November 1993
Resolved 10 November 1993
Navigation
Issued 11 September 1991 Resolved
VESSELS B.A. CHARTS WERE NOT CORRECTED TO DATE
Condition: Unknown
Due 15 September 1991
Resolved 16 September 1991
Navigation
Issued 20 February 1989 Resolved
CHART #18523 NOT ON BOARD.
Condition: Unknown
Due 20 February 1989
Resolved 20 February 1989

Ownership record