Records from 1987 to 1993. Most recent: inspection, 9 September 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
9 September 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 832788
11 September 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 99676
28 August 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 960054
19 May 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1263345
29 November 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 938389
17 October 1991
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254238
4 March 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1240178
22 January 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 910145
30 November 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1218040
26 October 1990
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1237149
14 September 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1197596
2 May 1989
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1209489
18 October 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 899250
6 October 1988
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1038124
10 December 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1002951
8 December 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1308395
29 October 1987
Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1024566
Engineering
Issued 19 May 1992
Resolved
PROVIDE A SECOND MEANS OF VENTILATION TO THE MACHINERY SPACES AS REQUIRED BY 46 CFR 182.20-45(C).
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Construction/Loadline
Issued 19 May 1992
Resolved
PROVIDE CAPTIVE CHAINS FOR THE HATCH COVERS ON THE BOW.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Engineering
Issued 19 May 1992
Resolved
PROVIDE A MEANS TO OPERATE THE FUEL SHUTOFF VALVES OUTSIDE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 17 October 1991
Resolved
PROVIDE SIX ADDITIONAL CHILD TYPE I LIFE PRESERVERS WITH PROPER MARKINGS._x001C_ VESSEL IS LIMITED TO THE CARRIAGE OF 100 TOTAL PERSONS UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Lifesaving
Issued 17 October 1991
Resolved
PROVIDE A SUITABLE RING LIFE BUOY 24 INCHES IN DIAMETER OR LARGER WITH PROPER MARKINGS, LINE AND WATERLIGHT.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Construction/Loadline
Issued 30 November 1990
Resolved
REPLACE IN ACCORDANCE WITH GOOD MARINE PRACTICE THE CROPPED OUT SECTION OF BOTTOM SIDE STRINGER FROM THE FIRST FRAME TO 6 INCHES AFT OF THE COLLISION BULKHEAD IN THE FORWARD COMPARTMENT OF THE PORT HULL.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Documentation
Issued 6 October 1988
Resolved
PROVIDE DISCHARGE OF OIL PROHIBITED PLACARD.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Lifesaving
Issued 29 October 1987
Resolved
PRIOR TO OPERATION, PROVIDE WATERTIGHT CONTAINER FOR DISTRESS FLARES.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Engineering
Issued 29 October 1987
Resolved
PROVIDE FLAME DEFLECTOR SHIELDS FOR PLASTIC RACOR FUEL FILTERS..
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Navigation
Issued 29 October 1987
Resolved
PRIOR TO OPERATION, PAINT BLACK MATT STRIP FORWARD OF PORT AND STARBOARD RUNNING LIGHTS.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Navigation
Issued 29 October 1987
Resolved
PERMANENTLY INSTALL HORN.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Documentation
Issued 29 October 1987
Resolved
PLACE ON BOARD THE CERTIFICATE OF DOCUMENTATION AND PERMANENTLY MARK THE OFFICIAL NUMBER ON THE INTERIOR HULL.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Navigation
Issued 29 October 1987
Resolved
PROVIDE VHF RADIO AND FCC FORM 824. UNTIL THIS ITEM IS CORRECTED, VESSEL'SROUTE IS RESTRICTED TO NOT MORE THAN 1,000 FEET FROM SHORE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Construction/Loadline
Issued 29 October 1987
Resolved
PROVIDE DOCUMENTATION CONCERNING NYLON THROUGH HULL FITTINGS, OR RENEW ALL THROUGH HULL FITTINGS WITH METALLIC FITTINGS.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Engineering
Issued 29 October 1987
Resolved
PRIOR TO OPERATYION, INSTALL FIXED HAND BILGE PUMP IN MAIN HULL.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Unknown
Issued 29 October 1987
Resolved
PRIOR TO OPERATION, PROVIDE PORTABLE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987
Resolved
PRIOR TO OPERATION, PROVIDE RETROREFLECTIVE TAPE FOR 10 CHILD LIFE JACKETS.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987
Resolved
PROVIDE 1 ADDITIONAL CHILD AND 6 ADDITIONAL ADULT LIFE JACKETS, UNTIL SUCH TIME, VESSEL'S TOTAL PASSENGER CAPACITY IS RESTRICTED TO 94 ADULTS AND 10 CHILDREN.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987