MAURY USCG vessel records Sign in
← All vessels

STRAITS VOYAGER

STRAITS VOYAGER is a 1987 freight ship. The Coast Guard has recorded 76 inspections since 1987, most recently in October 2016, along with 64 deficiencies and 1 operational control.

Records from 1987 to 2016. Most recent: inspection, 27 October 2016.

Built
1987
Last inspected
27 October 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8613188 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
293446
Flag
MALAYSIA
367381000 (licence lapsed)
Maury page id
psix-293446

Inspections, by type

…with no type recorded33
Years with a record 18 calendar years (1987–2016)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38659 - Convention (Subpart B), Gross Ton
11597 - Convention (Subpart B), Net Ton
13491 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KGTHMMSI 367381000 · cancelled · compulsorily equipped · granted 26 September 1996, cancelled 10 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 76

27 October 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6030851
30 September 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2207523
20 March 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2025055
23 December 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1722476
24 July 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 292125
29 April 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 289577
18 July 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 279867
13 July 2000 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 820169
24 May 2000 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1049836
1 March 2000 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381813
25 February 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1391237
3 January 2000 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 811876
13 September 1999 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361116
30 August 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 56823
21 January 1999 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 786924
10 August 1998 Type not recorded
No type recorded · Activities Europe · Activity 665684
26 July 1998 Re-Inspection
Physical examination · Activities Europe · Activity 1364798
28 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 171058
29 December 1997 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 778293
25 November 1997 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 773926
15 September 1997 COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1381028
14 September 1996 Re-Inspection · Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1367914
20 February 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1192308
19 February 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 37506
19 February 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 83451
8 December 1995 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1186078
7 November 1995 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 881864
28 September 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1182809
7 December 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 829860
30 November 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 868254
15 November 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396206
19 October 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359958
22 June 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 114118
14 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 366924
4 January 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 853790
11 October 1993 COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154853
25 August 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 9564
25 August 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 120262
12 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 128314
8 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 6022
22 April 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1137177
16 April 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 477291
15 December 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 829673
21 November 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 447883
17 November 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 354694
2 November 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1257134
24 May 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 514501
11 October 1991 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248025
31 July 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 528554
10 October 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907808
22 September 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 914196
14 February 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 539533
8 January 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 901895
26 November 1989 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 919615
8 October 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 905997
25 May 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 464113
19 May 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1347282
5 November 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 487048
24 October 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 891003
6 October 1988 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1199120
2 May 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1347558
13 April 1988 Deficiency Check · Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1343122
24 March 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 998046
17 March 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1299872
17 March 1988 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1300394
28 February 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 510994
29 January 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015710
29 January 1988 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1324049
28 January 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1324634
27 January 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324094
20 January 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1016197
6 January 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1317419
15 December 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004294
14 December 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1314316
30 October 1987 Construction Oversight · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331157
28 October 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1013690

Deficiency record · 64

Navigation › Collision/Grounding Avoidance › Radar
Issued 20 March 2004 Resolved
Repair 3 cm radar IAW 33 CFR 164.37(a).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2004
Resolution: Received technician report stating the the radar has been repaired.
Navigation
Issued 25 February 2000 Resolved
Repair main gyrocompass. The vessel may operate only if temporary repairs approved by the local OCMI have been made or a letter of deviation has beenissued by the COTP.
Condition: Unknown
Due 25 February 2000
Resolved 25 February 2000
Lifesaving
Issued 26 July 1998 Resolved
Failure to lower/release/operate lifeboats since 12MAR98.
Condition: Unknown
Due 26 July 1998
Resolved 26 July 1998
Construction/Loadline
Issued 15 September 1997 Resolved
Prove operation of all mechanically remote actuated sea valves.
Condition: Unknown
Due 15 September 1997
Resolved 15 September 1997
Fire Fighting
Issued 15 September 1997 Resolved
Remove unauthorized fire screen door hold backs on the door just forward ofthe elevator on the accommodation level and the door between the unlicensedquarters and the galley area on the accommodation level.
Condition: Unknown
Due 15 September 1997
Resolved 15 September 1997
Lifesaving
Issued 15 September 1997 Resolved
Provide a non skid surface leading to and around the steering gear room operating station.
Condition: Unknown
Due 15 September 1997
Resolved 15 September 1997
Navigation
Issued 14 September 1996 Resolved
Renew deviation table for magnetic compass, last one dated 15OCT87._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 1996
Resolved 22 September 1996
Lifesaving
Issued 14 September 1996 Resolved
Replace all eleven (11) U.K. approved ring buoys(which were installed on a temporary basis to replace rejected ring buoys) with USCG approved ring buoys prior to leaving Japanese waters._x001C_ _x001C_
Condition: Unknown
Due 18 September 1996
Resolved 22 September 1996
Fire Fighting
Issued 14 September 1996 Resolved
Place three of the ships spare portable CO2 15 lb bottles on station outside the paint locker, securely rigged, while having the 100 psi bottle hydrostatically tested, serviced, refilled, returned to the ship and installed prior to leaving Japanese waters. Use an approved test facility.
Condition: Unknown
Due 17 September 1996
Resolved 22 September 1996
Engineering
Issued 14 September 1996 Resolved
Conduct actual control tests of main engine in accordance with approved procedures from all locations, including testing of automatic shutdown frompilothouse and a loss of lube oil shutdown._x001C_ _x001C_
Condition: Unknown
Due 21 September 1996
Resolved 22 September 1996
Lifesaving
Issued 28 September 1995 Resolved
SERVICE LIFERAFTS IN ACCORDANCE WITH 46CFR91.25-15
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Documentation
Issued 28 September 1995 Resolved
PROVIDE COPY OF ABS 3RD ANNUAL SURVEY FOR SAFETY CONSTRUCTION, LOADLINE ANDCARGO GEAR CERTIFICATES IN ACCORDANCE WITH 46CFR91.60
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Fire Fighting
Issued 28 September 1995 Resolved
HYDROSTATIC TEST AND FILL 100LB CO2 BOTTLE FOR PAINT LOCKER FIXED SYSTEM ATAPPROVED D.O.T. FACILITY. IN ACCORDANCE WITH 46CFR91.25-20(a)(2)
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Lifesaving
Issued 28 September 1995 Resolved
RENEW LIFEBOAT SEAT BELTS; 4 EACH IN #1 LIFEBOAT, 7 EACH IN #2 LIFEBOAT. IN ACCORDANCE WITH 46CFR94.20-5(a)
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Lifesaving
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF THE GENERAL ALARM BELL LOCATED ON THE #5 CAR DECK LEVEL FORWARD STARBOARD SIDE.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
PROVIDE A SELF CLOSING DEVICE FOR THE GALLEY FIRE SCREEN DOOR TO THE CREW'SMESS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION FOR THE SMOKE DETECTION SYSTEM FOR CARGO HOLD ZONE 53.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
PROVIDE 6 NEW 50' X 2.5" FIRE HOSES.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
For the fixed low pressure CO2 system, prove operation of the high & low tank pressure alarms, low level alarm, & refrigeration failure alarm. Refill tank to the 90% level.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Accommodation/Occupational Safety
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS TO THE GALLEY MAIN VENTILATION FIRE DAMPER AND PROVEPROPER OPERATION TO A U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Electrical
Issued 15 November 1994 Resolved
REPAIR ALL BROKEN LIGHTS AND DEMONSTRATE OPERATION OF ALL LIGHTS IN THE BOWTHRUSTER ROOM.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Electrical
Issued 15 November 1994 Resolved
PROVIDE NO SMOKING SIGNS FOR BOTH THE PORT AND STARBOARD BATTERY LOCKER.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
FOR #1 LIFEBOAT, ADJUST THE FALL LENGTHS SO THAT BOTH THE AFT AND FORWARD FALLS ARE OF EQUAL LENGTH, ADJUST THE HAND BRAKE COUNTER WEIGHT ARM SO THATWHEN THE REMOTE BRAKE RELEASE CABLE IS RELEASED THE BRAKE WILL STOP THE BOATS DESCENT, AND ADJUST THE HAND CRANK MECHANISM TO ALLOW THE MANUAL OPS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Documentation
Issued 15 November 1994 Resolved
REPAINT STARBOARD DRAFT AND LOAD LINE MARKS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
AT NEXT U. S. PORT, HOLD A BOAT DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Fire Fighting
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS TO THE BROKEN CO2 ALARM HORN IN THE CARGO HOLD, CAR DECK LEVEL 5, STARBOARD SIDE IN WAY OF FRAME 106.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Construction/Loadline
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD SIDE SHELL DAMAGE AND ASSOCIATED INTERNAL STIFFENERS IN WAY OF CAR DECK LEVEL 9, FRAMES 153-157.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS TO THE TORN GLUE SEAM IN THE HANDS BETWEEN THE THUMBAND FINGERS ON 7 EXPOSURE SUITS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS TO THE TWO 02/EXPLOSIVE METERS AND PROVE PROPER OPERATION TO A COAST GUARD INSPECTOR.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Accommodation/Occupational Safety
Issued 15 November 1994 Resolved
PROVIDE PROPER VACUUM BREAKERS FOR THE GALLEY ICE MACHINES.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Unknown
Issued 15 November 1994 Resolved
MAKE PERMANENT REPAIRS TO THE AFT LOADING RAMP ATTACHMENT PIN SAFETY PLATESON THE STARBOARD AND CENTER PINS. RETAINING PLATES ARE NOT PROPERLY POSITIONED INTO THE PIN SLOT AND THE LOWER RETAINING BOLTS HAVE BEEN SHEERED.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 11 October 1993 Resolved
PROVIDE ONE METAL STORM OIL DISPENSER FOR EACH LIFEBOAT IN ACCORDANCE WITH 46CFR94.20-15.
Condition: Unknown
Due 11 October 1993
Resolved 11 October 1993
Electrical
Issued 2 November 1992 Resolved
INSTALL HIGH VOLTAGE MATTING IN FRONT OF AND BEHIND ALL 440 VOLT PANELS IN FAN ROOMS.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Navigation
Issued 2 November 1992 Resolved
PROVE PROPER OPERATION OF SPEED LOG.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Fire Fighting
Issued 2 November 1992 Resolved
HYDROSTATICALLY TEST ALL 5 PORTABLE CO2 FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Construction/Loadline
Issued 2 November 1992 Resolved
REPAIR OR RENEW CORRODED OUTSIDE ACCESS DOORS AND CASINGS ON UPPER DECK.
Condition: Unknown
Due 2 November 1992
Resolved 2 November 1992
Engineering
Issued 11 October 1991 Resolved
Complete test of automation procedures in sections a(wheelhouse control system) and B (main engine automatic protection system) to the satisfactionof the attending marine inspector.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Engineering
Issued 11 October 1991 Resolved
Resubmit revised test procedure for automation system to [name withheld] for approval.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Navigation
Issued 22 September 1990 Resolved
PRIOR TO DEPARTURE NEXT U.S. PORT, PROVE PROPER OPERATION OF UPPER STERN NAVIGATION LIGHT.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Fire Fighting
Issued 22 September 1990 Resolved
CONDUCT SATISFACTORY HYDROSTATIC TEST OF ALL FIRE HOSES FROM CAR DECKS ONE THRU FOUR.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Lifesaving
Issued 22 September 1990 Resolved
PROVIDE DOCUMENTATION OF SOLAS APPROVAL FOR PERSONNAL FLOATATION DEVICES ( PFD'S) PFD LIGHTS, AND RING BOUY'S.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Fire Fighting
Issued 22 September 1990 Resolved
REPAIR AND SHOW PROPER OPERATION OF GENERAL ALARM FLASHING LIGHT IN ENGINE ROOM AMIDSHIPS, GENERAL ALARM BELLS AT THE FOLLOWING LOCATIONS; CAR DECK #3, FR 21 C/L - CAR DECK #4, FR 197 C/L - AND CAR DECK #7, FR 21 C/L.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Engineering
Issued 22 September 1990 Resolved
RENEW OR REPAIR AND SHOW PROPER OPERATION OF #1 AND #2 SHIPS SERVICE AIR RECIEVER RELIEF VALVES PRIOR TO DEPARTURE NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Engineering
Issued 22 September 1990 Resolved
RENEW OR REPAIR AND SHOW PROPER OPERATION OF EMERGENCY GENERATOR AIR RECIEVER RELIEF VALVE PRIOR TO DEPARTURE NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Fire Fighting
Issued 22 September 1990 Resolved
PROPERLY MOUNT ALL ENGINE ROOM SMOKE DETECTION UNITS PRESENTLY HANGING BY WIRE / NYLON WIRE TIES.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Documentation
Issued 22 September 1990 Resolved
PROVIDE COAST GUARD APPROVAL LETTER FOR OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Lifesaving
Issued 22 September 1990 Resolved
PRIOR TO VESSEL DEPARTURE CHIBA, JAPAN, PROVIDE ON BOARD SEA SICK PILLS FOR LIFEBOATS ONE AND TWO.
Condition: Unknown
Due 22 September 1990
Resolved 22 September 1990
Lifesaving
Issued 8 January 1990 Resolved
PROVIDE ONBOARD SOLAS 83 APPROVED PERSONAL FLOTATION DEVICES (PFD'S), PFD LIGHTS AND RING BUOYS.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Engineering
Issued 6 October 1988 Resolved
SUBMIT REVISED PERIODIC TEST PROCEDURES FOR MACHINERY AUTOMATION TO [name withheld].
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Fire Fighting
Issued 6 October 1988 Resolved
POST REVISED FIRE CONTROL PLAN APPROVED BY [name withheld] ON 10NOV88.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Fire Fighting
Issued 13 April 1988 Resolved
INSTALL REMOTE CONTROL SWITCH FOR EMERGENCY FIRE PUMP IN THE ENGINE ROOM CONTROL BOOTH.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 24 March 1988 Resolved
PROVIDE BACK RESTS FOR PORT AND STARBOARD LIFEBOATS IN ACCORDANCE WITH APPROVED IHI CRAFT DWG. NO. K-11B.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Construction/Loadline
Issued 17 March 1988 Resolved
EFFECT PERMANET REPAIRS TO THE FOLLOWING FRACTURE: #7 CAR DECK, FRAME #31 AT THE PORT AFT ENGINEROOM CASING BULKHEAD TO CAR DECK #7 INTERSECTION.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Construction/Loadline
Issued 17 March 1988 Resolved
EFFECT PERMANENT REPAIRS TO THE FOLLOWING FRACTURE: #10 CAR DECK, FRAME 141; VENTILATION DUCTS, BOTH PORT AND STARBOARD.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Fire Fighting
Issued 29 January 1988 Resolved
REPLACE ALL IMPROPER SPANNER WRENCHES AT FIRE STATIONS THROUGHOUT VESSEL WITH WRENCHES WHICH ARE COMPATABLE WITH THE INSTALLED FIRE HOSES.
Condition: Unknown
Due 29 January 1988
Resolved 29 January 1988
Fire Fighting
Issued 30 October 1987 Resolved
INSTALL A REMOTE OPERATED SUCTION VALVE ON THE FIRE PUMP TO COMPLY WITH G-MSC COMMENTS OF LETTER M-70391 DATED 31 JULY 1987.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Electrical
Issued 30 October 1987 Resolved
PROVIDE AN ACCEPTABLE WATER TIGHT "PULL FREE" PLUG/RECEPTACLE FOR THE PORT AND STARBOARD LIFE BOAT BATTERY CHARGING CABLES.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Fire Fighting
Issued 30 October 1987 Resolved
PROVIDE COAST GUARD APPROVAL FOR THE INSTALLED CO2 PRE-DISCHARGE HORN LOCATED ON THE CAR DECK CO2 SYSTEM.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Lifesaving
Issued 30 October 1987 Resolved
OBTAIN COAST GUARD APPROVAL OF THE INSTALLED LIFE RAFTS TO MEET THE REQUIREMENTS OF SOLAS AS AMENDED OF REPLACE WITH SOLAS 83 APPROVED LIFE RAFTS.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Fire Fighting
Issued 30 October 1987 Resolved
REPLACE THE INSTALLED WYE FITTING(S) LOCATED IN THE ACCOMODATION AREA WITH WYE FITTINGS HAVING STOP VALVES FITTED TO EACH WYE BRANCH.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Fire Fighting
Issued 30 October 1987 Resolved
REPLACE THE INSTALLED 1 1/2" FIRE HOSES, NOZZLES AND FOG APPLICATORS ON CARDECKS WITH 2 1/2" USCG APPROVED HOSES, NOZZLES AND FOG APPLICATORS.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Fire Fighting
Issued 30 October 1987 Resolved
REPLACE THE INSTALLED INTERNATIONAL SHORE CONNECTION WITH ONE COMPLYING WITH 46 CFR 162.034.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Unknown
Issued 30 October 1987 Resolved
REMOVE ALL THE NON-DOT APPROVED COMPRESSED GAS CYLINDERS AT FIRST U. S. PORT.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Unknown
Issued 30 October 1987 Resolved
WHERE INSULATION IS INSTALLED ON THE VERTICAL SURFACES, DECK-TO-DECK INSULATING MATERIAL IS REQUIRED.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.