Records from 1992 to 2002. Most recent: inspection, 8 July 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
8 July 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1643468
17 June 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 291134
6 June 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 278723
23 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 426818
10 September 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 420286
23 April 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 415173
24 February 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 400977
9 October 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 396300
27 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 388376
16 August 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 381766
1 March 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 704095
21 February 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 375533
3 December 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 376245
27 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 476946
6 November 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 447698
17 April 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 357607
4 January 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 444635
10 April 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 350074
Electrical › Electric Generation Source (emergency)
Issued 8 July 2002
Resolved
VESSEL WAS UNABLE TO PROVIDE PROPER OPERATION OF EMERGENCY GENERATOR (AUTO-START AND AUTOMATICALLY TAKE LOAD). VESSEL MUST PROVIDE PROPER OPERATION TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO NEXT U.S. PORT. SOLAS 60 II/25
Action required: 15 - Rectify deficiencies by next port
Due 29 August 2002
Resolved 12 August 2002
Resolution: RECEIVED CLASS REPORT STATING VESSEL HAS COMPLETED PERIODICAL SURVEY SATISFACTORILY AND OUTSTANDING DEFICIENCY CONCERNING EMERGENCY GENERATOR AUTOSTART HAS BEEN RECTIFIED, TESTED, AND FOUND IN GOOD ORDER.
Construction/Loadline
Issued 23 April 1998
Resolved
THE VESSEL HAD A CONCRETE PATCH ON A GREY WATER LINE OUTBOARD OF A THROUGH-HULL CHECKVALVE LOCATED IN LOWER LEVEL OF ENGINE ROOM BELOW THE WATERLINE. CLASS IS REQUIRED TO PROVIDE A REPORT ON THIS PRIORT TO THE VESSEL'S NEXT U.S. PORT.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Lifesaving
Issued 24 February 1997
Resolved
THE VESSEL'S LIFEBOATS DID NOT HAVE THE REQUIRED RETRO-REFLECTIVE TAPE ON THE OUTSIDE OF THEIR LIFEBOATS AS REQUIRED BY SOLAS. THE VESSEL WAS INSTRUCTED TO CORRECT THE DEFICIENCY PRIOR TO NEXT U.S. PORT
Condition: Unknown
Due 5 June 1997
Resolved 5 June 1997
Construction/Loadline
Issued 24 February 1997
Resolved
VESSEL'S HULL HAD A T-SHAPED FRACTURE ON THE PORT SIDE IN WAY OF THE FOREPEAK TANK (APPROXIMATELY 1' X 8") 10 FEET FORWARD OF DRAFT MARKINGS; LEAKING WATER FROM FRACTURE. THE VESSEL WAS REQUIRED TO MAKE TEMP REPAIRS PRIOR TO DEPARTURE AND PERMANENT REPAIRS PRIOR TO ENTERING NEXT U.S PORT.
Condition: Unknown
Due 3 June 1997
Resolved 3 June 1997
Navigation
Issued 21 February 1995
Resolved
VESSELS' ARPA WAS NOT PROPERLY LABELED.
Condition: Unknown
Due 17 August 1995
Resolved 17 August 1995