Records from 2001 to 2016. Most recent: operational control imposed, 9 January 2016.
Inspection history · 19
9 January 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5794428
7 January 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5793341
9 July 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4373458
11 February 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3416079
18 January 2008
MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3127555
29 May 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2945265
7 April 2006
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2611968
1 November 2005
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2526908
18 July 2005
PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2421270
4 April 2005
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2326506
9 December 2004
Random ISPS/MTSA/PSC
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2256267
5 August 2004
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2156258
22 February 2004
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2010573
19 August 2003
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1876234
21 January 2003
Re-Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1732097
10 June 2002
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1627587
30 December 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1482656
30 September 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294136
16 June 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 290949
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 9 January 2016
Resolved
Due to the objective evidence found in deficiencies 1, 2, 3, and 5; the PSCO believes that there are Clear Grounds for believing that the Safety Management System is not being implemented properly. It is recommended by the PSCO that an additional ISM Audit be conducted by the Certificate Issuing Authority prior to departure. 74 SOLAS (14 Cons)XI-1/4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2016
Resolution: NKK has completed SMS survey.
Engineering › Pressure Vessel › Piping
Issued 9 January 2016
Resolved
Machinery, boilers, & other pressure vessels, associated piping systems & fittings shall be of a design & construction adequate for the service for which they are intended & shall be installed & protected as to reduce to a minimum any danger to persons on board..Numerous soft patches not reported to Class or Company (see narrative for details) 74SOLAS(14 Cons) II-1/26.1 17(a)(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2016
Resolution: Received NKK Class report that all repairs have been completed.
Lifesaving › Lifeboat › Hull
Issued 9 January 2016
No resolution recorded
Before the ship leaves port & at all times during the voyage, all life saving appliances shall be in working order. Both Lifeboats have de-laminating patches above propeller & damage near anchoring lift points. Port lifeboat has separation between deck & hull showing light. Restraining strap has damaged/crushed deck. Stbd Lifeboat has signs of hull/deck 74SOLAS(14Cons)III/20.2
Action required: 705 - Other - as specified
Due 24 February 2016 — due date passed with no resolution recorded
Resolution: Flag State Dispensation Letter valid until 24FEB16 as long as vessel carries the required number of extra liferafts
Engineering › Steam System (main) › Piping
Issued 9 January 2016
Resolved
Machinery, boilers, & other pressure vessels, associated piping systems & fittings shall be of a design & construction adequate for the service for which they are intended & shall be installed & protected as to reduce to a minimum any danger to persons on board. Active steam leaks in oil purifier room near valves requiring manual operation from crew. 74SOLAS(14 Cons) II-1/26.1 17(a)(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2016
Resolution: Received NKK Class report that all repairs have been completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2016
Resolved
Electrical installations shall be such that the safety of passengers, crew & ship from electrical hazards shall be ensured. PSCO observed Class approved portable generator on deck in use due to #2Generator inoperable. The electrical wiring is exposed, not in junction box, & signs of heat damage & open wire splicing. 74SOLAS (Cons 14) II-1/40.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2016
Resolution: Received NKK Class report that all repairs have been completed.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 9 January 2016
Resolved
The function of a fixed fire detection & fire alarm systems shall be periodically tested to satisfaction of Administration by means of equipment producing hot air at appropriate temp. or smoke or aerosol particles having appropriate size..PSCO asked crew to test flame detector, crew attempted test with lighter in oil purifying room. 74SOLAS(14Cons)II-2/7.3.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2016
Resolution: Received NKK Class report that all repairs have been completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 January 2016
Resolved
Machinery, boilers, & other pressure vessels, associated piping systems & fittings shall be of a design & construction adequate for the service for which they are intended & shall be installed & protected as to reduce to a minimum any danger to persons on board...Conduit for numerous wiring connections are broken with exposed wires
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2016
Resolution: Received NKK Class report that all repairs have been completed.
Engineering › Steering Gear System › Piping
Issued 9 January 2016
Resolved
Machinery, boilers, & other pressure vessels, associated piping systems & fittings shall be of a design & construction adequate for the service for which they are intended & shall be installed & protected as to reduce to a minimum any danger to persons on board. The steering gear system has multiple leaks at the pump. Crew must refill hydraulic tanks on regular basis. 74SOLAS(14Cons)II-1/26.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2016
Resolution: Received NKK Class report that all repairs have been completed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 January 2016
Resolved
While observing Accomodation space exam, PSCO observed narcotics in a labeled box in unsecured room. Spoke with Captain about his duties / responsibilities for securing all medical narcotics onboard the vessel. ILO 147 / PWSA 33 USC 1223(b)
Action required: 705 - Other - as specified
Due 10 January 2016
Resolved 10 January 2016
Resolution: Captain locked the container in master's cabin.
Documentation › Logs/Records › Oil Record Book
Issued 10 June 2002
Resolved
Update the IOPP certificate to reflect tank capacities as actual onboard vessel. MARPOL 73/78 Annex 1
Action required: 15 - Rectify deficiencies by next port
Resolved 4 July 2002
Resolution: Rcvd fax from master verifying update of the IOPP certificate by class NKK.
Documentation › Logs/Records
Issued 10 June 2002
Resolved
Commence making entries into the oil record book as indicated by the instructions. MARPOL 73/78 Annex 1, Appendix III LEGACY COMPONENT DESC: Oil Record Book
Action required: 705 - Other - as specified
Resolved 4 July 2002
Resolution: Rcvd fax from master verifying update of the IOPP certificate by class NKK.
Navigation
Issued 16 June 2001
Resolved
Missing publication - Inland Navigation Rules (USCG) 33 CFR 164.30.
Condition: Unknown
Due 16 July 2001
Resolved 18 June 2001
Navigation
Issued 16 June 2001
Resolved
Chart not corrected (chart #18526) 33 CFR 14.30.
Condition: Unknown
Due 16 July 2001
Resolved 18 June 2001
Documentation
Issued 16 June 2001
Resolved
Incomplete oil transfer procedures. Missing means of communication, list of products and line tending. 33 CFR 155.720 - 760.
Condition: Unknown
Due 30 September 2001
Resolved 1 October 2001