Records from 1988 to 1996. Most recent: inspection, 6 February 1996.
Documentation record
Registered dimensions (L × B × D)42.1 ft × 13.2 ft × 5.1 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCERTIFIED MARINE CORP · ANAHEIM CA, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVENTURA, CA
Trade endorsementsRecreational
DocumentationValid · issued 29 August 2022 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Net Ton
18 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
6 February 1996
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 874133
29 September 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430088
14 September 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385321
22 March 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354622
11 February 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1412600
13 January 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399981
16 December 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1403568
16 October 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1247698
23 September 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 941056
16 October 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1236206
27 November 1989
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229594
25 October 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209769
22 September 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 899076
13 December 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 898699
29 November 1988
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 895977
11 October 1988
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 893449
Construction/Loadline
Issued 11 February 1994
Resolved
REMOVE AND RENEW WASTED 2 INCH CONE VALVE FOR HEAD SEA SUCTION THROUGH HULL.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Engineering
Issued 11 February 1994
Resolved
REMOVE WASTED CUTLASS BEARING IN WAY OF STARBOARD TAILSHAFT AND RENEW AS ORIGINAL.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Construction/Loadline
Issued 13 January 1994
Resolved
PROVE PROPER OPERATION OF HAND BILGE/FIRE PUMP PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 11 February 1994
Resolved 16 February 1994
Lifesaving
Issued 13 January 1994
Resolved
PROPERLY MARK LIFE FLOAT PADDLES IAW 46 CFR 185.30-5.
Condition: Unknown
Due 11 February 1994
Resolved 16 February 1994
Lifesaving
Issued 13 January 1994
Resolved
PROPERLY ATTACH WATER LIGHT AND HEAVING LINES SO THAT THEY ARE FED THROUGH AND AROUND THE BODY OF THE RING BUOY. ITEM TO BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS._x001C_ _x001C_
Condition: Unknown
Due 11 February 1994
Resolved 16 February 1994
Accommodation/Occupational Safety
Issued 13 January 1994
Resolved
PROVIDE AND INSTALL LOCKING DEVICE FOR MSD OVERBOARD DISCHARGE VALVES TO SECURE VALVE IN CLOSED POSITION WITHIN 3 MILES OF SHORE.
Condition: Unknown
Due 11 February 1994
Resolved 16 February 1994
Construction/Loadline
Issued 13 January 1994
Resolved
HAUL VESSEL OUT AND MAKE AVAILABLE FOR EXAMINATION BY CG MARINE INSPECTOR AS PER 46 CFR 176.15-1 & 5.
Condition: Unknown
Due 11 February 1994
Resolved 16 February 1994
Fire Fighting
Issued 13 January 1994
Resolved
PROVIDE EVIDENCE OF CURRENT SERVICE FOR ALL PORTABLE FIRE EXTINGUISHERS ANDINSTALLED HALON SYSTEM PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 11 February 1994
Resolved 16 February 1994
Lifesaving
Issued 23 September 1991
Resolved
Renew vessel's lifefloat waterlight battery.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Documentation
Issued 23 September 1991
Resolved
Provide vessel with written refuse disposal plan and substance abuse_x001C_ testing program.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Lifesaving
Issued 23 September 1991
Resolved
Renew vessel's lifering.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Lifesaving
Issued 23 September 1991
Resolved
Renew all emergency flares.
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Lifesaving
Issued 23 September 1991
Resolved
Renew vessel's EPIRB battery.
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Engineering
Issued 23 September 1991
Resolved
Repair starboard main engine tachometer.
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Engineering
Issued 16 October 1990
Resolved
PROVE OPERATION OF FROZEN EMERGENCY FUEL SHUTDOWN FOR GENERATOR FEED LINE.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Lifesaving
Issued 25 October 1989
Resolved
REPLACE ALL GRAB LINES ON 10-PERSON LIFEFLOAT.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Construction/Loadline
Issued 25 October 1989
Resolved
INSTALL HINGED DEAD COVERS ON ALL SIX PORT LIGHTS.
Condition: Unknown
Due 12 January 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 22 September 1989
Resolved
MARK NAME OF VESSEL ON PORT AND STBD BOW AREA OF THE HULL.
Condition: Unknown
Due 22 September 1989
Resolved 22 September 1989
Electrical
Issued 11 October 1988
Resolved
PROVIDE EMERGENCY LIGHT FOR BUNKROOM.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Lifesaving
Issued 11 October 1988
Resolved
MAKE LIFE FLOAT FLOAT-FREE.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Accommodation/Occupational Safety
Issued 11 October 1988
Resolved
STENCIL TOPSIDE OF FWD EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988