Records from 1987 to 1999. Most recent: inspection, 30 April 1999.
Documentation record
Registered dimensions (L × B × D)42.3 ft × 14.0 ft × 6.5 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELDEN G WILLIAMS · SOUTH LAKE TAHOE, CA, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portJUNEAU, AK
Trade endorsementsFishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Net Ton
25 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
30 April 1999
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 799730
30 April 1999
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 799731
21 May 1998
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 127717
19 June 1997
Deficiency Check · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1380902
7 June 1997
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 174558
28 April 1997
Hull Examination · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1396760
18 June 1996
Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1374801
6 April 1995
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 17495
13 March 1995
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1357100
3 November 1994
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1174780
12 May 1994
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1463124
14 May 1993
Re-Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1403617
30 April 1992
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1410731
10 August 1991
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 940370
26 April 1991
Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999404
11 April 1991
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1235445
24 April 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220733
17 April 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1039545
23 August 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1346496
21 April 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1194041
21 April 1988
Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1198860
23 July 1987
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1198856
23 July 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1198859
Engineering
Issued 19 June 1997
Resolved
REPLACE PORT FUEL OIL TANK VENT FLAMESCREEN.
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 19 June 1997
Resolved
MARK IDENITIFICATION ON FIRE & BILGE MANIFOLD VALVES AND DIAGRAM PIPING ALIGNMENT TO SHOW PROPER SUCTION & DISCHARGE FOR FIRE MAIN OR BILGE PUMPING
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Lifesaving
Issued 19 June 1997
Resolved
REPLACE THREE ADULT LIFEJACKETS, REPAIR OR REPLACE ADDITIONAL ONE ADULT LIFE JACKET.
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Electrical
Issued 19 June 1997
Resolved
CLEAN BATTERY TERMINALS AND WIRE CONNECTIONS, REMOVE STANDING WATER FROM PLASTIC BATTERY BOXES. PROVIDE ADDITIONAL COVER OVER BOXES TO PREVENT WATERENTRY OR MODIFY BOXES (DRILL) DRAIN HOLES IN BOX BOTTOMS.
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Accommodation/Occupational Safety
Issued 19 June 1997
Resolved
CLOSE MSD OVERBOARD VALVE & LOCK IN CLOSED POSITION (WIRE TIE). TAG VALVE WITH SIGN STATING VALVE IS NOT TO BE OPENED INSIDE OF THREE MILES OF US COASTAL WATERS.
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Engineering
Issued 19 June 1997
Resolved
REPAIR/REPLACE PORT SIDE ENGINE COMPARTMENT EXHAUST VENT MOTOR, PLACE DUCTING ON STBD SIDE EXHAUST VENT MOTOR TO TAKE SUCTION FROM THE LOWER PARTOF THE COMPARTMENT BILGES.,
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 19 June 1997
Resolved
REPAIR MECHANICAL (ENGINE DRIVEN) FIRE/BILGE PUMP
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Accommodation/Occupational Safety
Issued 19 June 1997
Resolved
INSTALL A VACUME BREAKER/ANTI-SIPHION VALVE BETWEEN FRESH WATER TANK PUMP DISCHARGE AND MARINE HEAD SUPPLY LINES
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Lifesaving
Issued 19 June 1997
Resolved
REPLACE SUN ERRODED LINE AROUND 2 RING BOUYS ON UPPER DECK
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Lifesaving
Issued 19 June 1997
Resolved
SECURE PAINTER LINE AND WATERLIGHT LINES AROUND BODY OF LIFE FLOAT, SECURE BUCKET HOLDING PAINTER LINE, STOW PAINTER LINE TO PAY OUT OF BUCKET IN A TANGLE FREE MODE.
Condition: Unknown
Due 20 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 28 April 1997
Resolved
CLEAN BILGES IN WAY OF SUCTION STRAINERS & REMOVE OIL AND GREASE FROM ENG ROOM BILGES.
Condition: Unknown
Due 1 June 1997
Resolved 28 May 1997
Construction/Loadline
Issued 28 April 1997
Resolved
REPLACE PLASTIC/NYLON SPEED INDICATING TRANSDUCER THROUGH HULL FITTING WITHA SUITABLE METAL TYPE FITTING AND/OR ENCLOSE & BOX WITH A COFFERDAM.
Condition: Unknown
Due 1 June 1997
Resolved 28 May 1997
Construction/Loadline
Issued 28 April 1997
Resolved
REPLACE EXISTING PLASTIC/NYLON MSD THROUGH HULL FITTING WITH A SUITABLE METAL TYPE FITTING AND INSTALL A SKIN VALVE WHICH CAN BE READLY ACCESSED & AND OPERATED.
Condition: Unknown
Due 1 June 1997
Resolved 28 May 1997
Construction/Loadline
Issued 28 April 1997
Resolved
LABEL/TAG ALL VALVES IN THE BILGE SUCTION & FIRE MAIN MANIFOLD SYSTEM. DIAGRAM & POST PROPER VALVE ALLIGNMENT ORDER FOR CHARGING FIRE MAIN, OR _x001C_ TAKING BILGE SUCTION.
Condition: Unknown
Due 1 June 1997
Resolved 28 May 1997
Engineering
Issued 28 April 1997
Resolved
REPLACE OR REPAIR ENG RM EXHAUST DUCTING TO TAKE SUCTION FROM LOWER AREA OFENG RM BILGES.
Condition: Unknown
Due 1 June 1997
Resolved 28 May 1997
Electrical
Issued 13 March 1995
Resolved
PROPERLY SECURE WIRE RUNS THRU BILGE VOIDS, MAKE UP WIRE RUNS AS HIGH FROM BILGE AREAS AS PRACTICABLE, AND REMOVE OR PROPERLY DEAD END WIRES TO EXTRA HEATERS IN CABIN.
Condition: Unknown
Due 1 April 1995
Resolved 16 April 1995
Fire Fighting
Issued 13 March 1995
Resolved
COMPLETE REPAIRS ON FIRE/BILGE PUMP & PROVE SAT OPERATION. VESSEL MAY NOT OPERATE UNDER TERMS OF COI UNTIL PUMP IS OPERATIONAL.
Condition: Unknown
Due 1 April 1995
Resolved 16 April 1995
Lifesaving
Issued 13 March 1995
Resolved
PLACE ALL LIFE SAVING GEAR AT PROPER LOCATIONS, TO INCLUDE LIGHTS ON RING BOUYS, RING BOUYS ON DECK STATIONS, LIFE JACKETS IN MARKED LOCATIONS AND GENERALLY PREPARE VESSEL'S SAFETY GEAR FOR THIS SEASON'S OPERATIONS.
Condition: Unknown
Due 1 April 1995
Resolved 16 April 1995
Fire Fighting
Issued 13 March 1995
Resolved
CONNECT THE CO2 CYLINDER TO THE FIXED SYSTEM FOR ENG COMPARTMENT.
Condition: Unknown
Due 1 April 1995
Resolved 16 April 1995
Accommodation/Occupational Safety
Issued 13 March 1995
Resolved
SECURE OVBD DISCHARGE VALVE/LOCK CLOSED & TAG "DO NOT OPEN U.S. WATERS".
Condition: Unknown
Due 1 April 1995
Resolved 16 April 1995
Unknown
Issued 13 March 1995
Resolved
REMOVE OIL FROM ENG RM BILGE.
Condition: Unknown
Due 1 April 1995
Resolved 16 April 1995
Documentation
Issued 12 May 1994
Resolved
PREPARE & POST WRITTEN WASTE MANAGEMENT PLAN/MAKE AVAILABLE TO BOTH CREW & PASSENGERS.
Condition: Unknown
Due 12 May 1994
Resolved 12 May 1994
Navigation
Issued 12 May 1994
Resolved
PREPARE DEVIATION TABLE FOR SHIP'S COMPASS.
Condition: Unknown
Due 12 May 1994
Resolved 12 May 1994
Electrical
Issued 11 April 1991
Resolved
SUBMIT FOR APPROVAL PLANS FOR NEW INSTALLED INVERTER ELECTRICAL SYSTEM AND MAKE SAME AVAILABLE FOR EXAMINATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991