Records from 1987 to 2016. Most recent: inspection, 31 May 2016.
Inspection history · 78
31 May 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5892852
12 August 2008
Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3510941
22 July 2008
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3283194
26 April 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3201760
1 April 2008
Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3175427
1 February 2008
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3140674
19 December 2007
In-Service Inspection · Drydock Extension · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3118074
13 December 2007
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3114986
22 November 2007
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3103133
10 October 2007
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3077180
6 October 2007
Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3075425
28 July 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3009718
13 July 2007
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2993859
9 July 2007
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2989024
25 October 2006
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2872419
2 August 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2733755
2 August 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2733807
1 August 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2732348
31 July 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2732331
12 June 2006
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2678105
30 May 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2667964
17 May 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2656685
5 May 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2641205
20 April 2006
MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2629114
28 February 2006
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2594294
13 January 2006
Deficiency Check · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2566385
3 January 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2563872
6 August 2005
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2473146
9 June 2005
MTSA Verification · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2390580
12 April 2005
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2334411
23 January 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2286491
9 July 2004
MTSA Verification · In-Service Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2127179
27 May 2004
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2079545
9 October 2003
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1923838
29 August 2001
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1418958
4 April 2001
Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1064683
5 February 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1384666
23 June 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1095329
4 December 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1416603
5 June 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1388295
7 February 1997
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1421283
24 October 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1374780
24 October 1996
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1416372
9 November 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1182666
7 November 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1407571
25 September 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1188672
19 April 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 854287
27 March 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 829882
15 February 1995
Deadweight Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355101
6 February 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1143745
28 September 1994
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1394177
21 March 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1165588
24 January 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850541
30 November 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 691618
17 November 1993
MARPOL Annex V Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1467395
16 February 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 834314
21 November 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 119930
18 November 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410757
27 October 1992
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1415778
8 October 1992
Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 826227
9 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1268298
11 May 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1266021
16 January 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 948782
21 November 1991
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 959495
3 October 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 932535
2 October 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1247869
21 April 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 921848
15 April 1991
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1227404
11 February 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 915132
26 November 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 916817
26 November 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 923814
30 March 1990
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908178
28 February 1990
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 907593
12 January 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1223815
28 November 1989
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1239322
6 December 1988
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1208990
1 December 1988
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 897342
18 December 1987
Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1316044
Construction/Loadline › Hull › Hull Plating
Issued 22 July 2008
Resolved
Water blast paint off of hull prior to dry dock exam.
// [name withheld]
Action required: 705 - Other - as specified
Resolved 12 August 2008
Resolution: Vessel condition did not require the hull to be water blasted.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 2 February 2008
Resolved
Vessel replaced existing port MDE with an identical rebuilt MDE to affect repairs on the original. Prove proper operation underway to USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2008
Resolution: Conducted sea trials, engine is working properly.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 December 2007
Resolved
Return spring for throttle linking became dislodged from fwd attachment point on Stbd MDE.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 13 December 2007
Resolution: Return spring was re-attached to fwd attachment point.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 October 2007
Resolved
Replace battery cable running from battery box to port MDE. Cable is chaffed due to contact with broken bracket
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2007
Stability › Incline Test › General
Issued 12 October 2007
Resolved
Provide specs. for 03 A/C overhead units installed in main passenger cabin for stability calculations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2007
Stability › Unintentional Flooding › General
Issued 12 October 2007
Resolved
Clean area around shaft seal and make ready for inspection. "Mud" from packing replacment obscuring potential leaks.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 22 November 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 October 2007
Resolved
Mark fuel shutoff handle in main passenger cabin with directional labels (open/closed).
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 22 November 2007
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 12 October 2007
Resolved
Replace chaffed line to oil gauge on port MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2007
Stability › Incline Test › General
Issued 10 October 2007
Resolved
Provide specs on new generator and old generator to determine weight change.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2007
Resolution: New Stability letter issued by MSC after satisfactory inclining experiment and stability calculations.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 October 2007
Resolved
Remove oil and oily water from engine room bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 October 2007
Resolved
Remote fuel cutoff for engine room doesn't function. Repair/replace and test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2007
Resolution: Fuel shutoff valve operational.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 October 2007
Resolved
Starboard aft upper deck seat foundation is loose. Repair seat.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 22 November 2007
Engineering › Fuel Oil Service System › Hose
Issued 10 October 2007
Resolved
Replace cracked fuel hoses on both MDEs. (Lines from hard pipe to fuel filter)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 October 2007
Resolved
Label upper deck lifejacket storage child/adult specific.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 12 October 2007
Resolution: Storage unit labeled.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 October 2007
Resolved
Re-attach light cover on 2nd deck under overhang.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 12 October 2007
Resolution: Light cover replaced.
Documentation › Logs/Records › Logbook (official)
Issued 10 October 2007
Resolved
Provide proof of proper vessle logbook entries by all captais who operate vsl.
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 22 November 2007
Stability › Weathertight Integrity › General
Issued 10 October 2007
Resolved
Replace cracked window in bridge door, stbd side.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 12 October 2007
Resolution: Window replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 10 October 2007
Resolved
Provide proof of all 06 B-II portable fire extinguishers onboard vsl IAW COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 October 2007
Resolved
Post Certificate of Inspection (COI) in view of passengers (all pages).
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 22 November 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 October 2007
Resolved
Conduct underway drills with attending USCG Marine Inspector to include operational test of stbd engine repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2007
Electrical › Electric Supply System (service) › Cable
Issued 6 October 2007
Resolved
Renew defective battery cable and provide missing battery for service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2007
Resolution: Corrected.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 6 October 2007
Resolved
Make vessel available for engine trials with crew once vessel ready.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2007
Resolution: Conducted operational tests.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 28 July 2007
Resolved
Bridge throttle control installed incorrectly.
Action required: 705 - Other - as specified
Resolved 28 July 2007
Resolution: Technician re-installed the gear. Marine Inspectors conducted check ride and verified proper operation of the equipment.
Engineering › Steering Gear System › Chain
Issued 13 July 2007
Resolved
The chain for the steering trottle came off, engineers fixed the problem.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Adjustment was made to the chain.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 25 October 2006
Resolved
Vessel gen set found in opertive,
Action required: 705 - Other - as specified
Resolved 30 June 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 July 2006
Resolved
Remove obstruction of engine cooling pipe iwo screener and test system prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 June 2006
Resolved
Provide safe passenger loading ramp that will allow for safe loading during all tidal stages, current ramp present unsafe due to angle more than 60 %
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2006
Resolution: Vessel made repairs to hyd ramp which allows movement during all tidal stages Inspected and found sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 May 2006
Resolved
Repair vessel starting system to operate as designed. Vessel has 24v problems engines will not start properly. (troubleshoot batteries and charger)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2006
Resolution: cleared
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 May 2006
Resolved
repair rear door lock (safety hazard for passengers).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2006
Resolution: cleared
Engineering › Lubricating Oil Service System › Gauge
Issued 30 May 2006
Resolved
Repair all inoperative pilothouse gauges and temporarely install gauges bezel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 May 2006
Resolved
Vsl has its mooring lines tangled in the stbd prop. Remove line and isnp shaft/prop. Prove proper operation of system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2006
Resolution: Vsl has cleared and proved proper operation.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 20 April 2006
Resolved
Vessel L/O pressure gauges does not work, replace/repair L/O gauges
Due 28 April 2006
Resolved 30 June 2007
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 20 April 2006
Resolved
Vessel rudder angle indicator does not operate
Due 28 April 2006
Resolved 2 May 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 February 2006
Resolved
Repair cracked 4 person seating row.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 3 May 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 28 February 2006
Resolved
Remove hold downs on engineroom fire dampers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 28 February 2006
Resolved
Remove hold downs on engineroom fire dampers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2006
Communications › Audible Communications › SPD (Other)
Issued 28 February 2006
Resolved
Repair inoperative PA system.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 3 May 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 February 2006
Resolved
Repair all cracked welds found on maindeck stern side gangways and rails.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 February 2006
Resolved
Properly align both shafts.
Action required: 705 - Other - as specified
Resolved 18 February 2006
Engineering › Bilge Water Management System › Strainer
Issued 7 February 2006
Resolved
Missing handle found in Port strainer
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 February 2006
Resolved
Secure all battery covers.
Action required: 705 - Other - as specified
Resolved 17 February 2006
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 13 January 2006
Resolved
Replace both shaft cutlass bearings on port and starboard side.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 13 January 2006
Resolved
Replace port and starboard side rudder cutlass bearings.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Construction/Loadline › Hull › Transverse Frame
Issued 13 January 2006
Resolved
Renew marked area of transverse deck frame #12, underneath the water tank.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2006
Resolved
Renew stuffing box, starboard side engine room entrance.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Electrical › Electric Generation Source (service) › Generator Cable
Issued 13 January 2006
Resolved
Replace generator ground cable.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 13 January 2006
Resolved
Replace missing sections of insulation throughout in the engine room.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2006
Resolved
Ensure all wiring and cables are properly attached throughout the vessel.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 January 2006
Resolved
Properly mount pressurized water tank in port side engine room.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 January 2006
Resolved
Replace gauges on DC panel, port side engine room.
Action required: 705 - Other - as specified
Resolved 2 May 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 January 2006
Resolved
Renew framing of the DC panel, port side engine room.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 13 January 2006
Resolved
Repair port side engine room entrance fire damper.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2006
Resolved
Repair railing throughout vessel as needed.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Completed
Construction/Loadline › Structures › Door
Issued 13 January 2006
Resolved
Re-install port and starboard passenger access doors.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Construction/Loadline › Structures › Deck Plating
Issued 13 January 2006
Resolved
Make permanent repairs to structural frames on the deck extension (skirt).
Action required: 705 - Other - as specified
Resolved 7 February 2006
Engineering › Sea-water System (primary cooling) › Valve
Issued 13 January 2006
Resolved
Replace valve handle on inboard sea chest.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Engineering › Sea-water System (primary cooling) › Valve
Issued 13 January 2006
Resolved
Remove all through-hull fittings and have available for visual inspection.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 January 2006
Resolved
Clean bilges underneath the sewage tank and have ready for inspection.
Action required: 705 - Other - as specified
Resolved 7 February 2006
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 13 January 2006
Resolved
Provide anchor with chain, shackle and rope of sufficient length in accordance with manufacturer specs.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Engineering › Steering Gear System › Pin
Issued 13 January 2006
Resolved
Replace cutter pins installed or missing for the rudders steering crossbar at steering compartment.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Construction/Loadline › Hull › Transverse Frame
Issued 13 January 2006
Resolved
Repair all cracked welds identified in the frames at steering compartment.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Engineering › Bilge Water Management System › Piping
Issued 13 January 2006
Resolved
Repair all 3 piping brackets found carcked at sewage tank compartment.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Construction/Loadline › Structures › Superstructure
Issued 13 January 2006
Resolved
Repair creacked welds on rail located port/aft on 2nd deck.
Action required: 705 - Other - as specified
Resolved 14 February 2006
Resolution: Corrected
Operations/Management › Passenger Operations › Safety Orientation
Issued 13 January 2006
Resolved
Post passenger capacity sign for 2nd deck.
Action required: 705 - Other - as specified
Resolved 17 February 2006
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 3 January 2006
Resolved
Renew both main diesel engines and ship service generator or provide evidence of rebult condition. And install hourmeters on all engines. Conduct at next drydock.
Action required: 705 - Other - as specified
Resolved 30 June 2007
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 6 August 2005
Resolved
Repair inoperative port a/c unit. COI passenger count downgraded to 148 passengers.
Due 13 August 2005
Resolved 11 August 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 August 2005
Resolved
Remove all excess oil & water in bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Electrical › Electric Generation Source (service) › Number of Sources
Issued 6 August 2005
Resolved
Remove all old laying batteries and excess trash from engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2005
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 6 August 2005
Resolved
Correct all machinery oil leaks.
Due 13 August 2005
Resolved 24 September 2005
Engineering › Fuel Oil Service System › Valve
Issued 9 June 2005
Resolved
REPAIR SEIZED EMERGENCY FUEL SHUTOFFS.
Due 10 June 2005
Resolved 15 June 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 June 2005
Resolved
CROP AND RENEW MISSING BIT AND DAMAGED HANDRAIL FORWARD.
Action required: 705 - Other - as specified
Due 9 July 2005
Resolved 15 June 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 12 April 2005
Resolved
Prior to carrying passengers provide potable water thruout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 April 2005
Resolved
Prior to carrying passengers provide operational sewage system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2005
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 12 April 2005
Resolved
Prior to carrying passengers, repair exhaust leak on portside muffler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 9 July 2004
Resolved
Proved a proper embarkation gangway at the Catano Ferry Terminal.
Action required: 705 - Other - as specified
Due 12 July 2004
Resolved 16 July 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 May 2004
Resolved
Provide evidence of all conducted Man Overboard drills.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Operations/Management › Drills/Instruction › Fire
Issued 27 May 2004
Resolved
Provide proper evidence of all Fire fighting drills.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Operations/Management › Drills/Instruction › Safety Orientation
Issued 27 May 2004
Resolved
Provide evidence of a proper passenger safety orientation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 May 2004
Resolved
Provide proof of enrollment in the drug and alcohol testing program.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2004
Resolved
Provide a new first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 27 May 2004
Resolved
Make proper housekeeping "cleaning" of both restrooms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 27 May 2004
Resolved
Demonstrate proper operations of vessels' radios under battery back up " emergency source of power".
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 May 2004
Resolved
Demonstrate proper operations of the visual high bilge alarm for rudder room and label two lights with the name of the space protected. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 17 June 2004
Fire Fighting › Fire Pumps › Capacity
Issued 27 May 2004
Resolved
Demonstrate proper operations of the fire pump to meet max PSI of 60.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 27 May 2004
Resolved
Provide five new lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 May 2004
Resolved
Provide a copy of Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2004
Resolved 17 June 2004
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 27 May 2004
Resolved
Provide a copy of Local Notices to Mariners. LEGACY COMPONENT DESC: Local Notices to Mariners
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Navigation › Piloting/Steering › Marine Charts
Issued 27 May 2004
Resolved
Provide a copy of the local marine charts. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 May 2004
Resolved
Provide a copy of Tide and Currents table. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2004
Resolved 17 June 2004
Engineering › Shafting/Propeller Arrangements
Issued 9 October 2003
Resolved
Found extensive evidence of pitting in critical areas around propeller hub. Remove Repair and balance both installed propellers. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 November 2003
Resolved 16 October 2003
Resolution: CLEARED
Engineering
Issued 9 October 2003
Resolved
Found all hull zinc anodes at borderline wastage. Remove all wasted zincs and renew. LEGACY COMPONENT DESC: HULL ZINCS
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 November 2003
Resolved 16 October 2003
Resolution: CLEARED
Engineering › Sea-water System (primary cooling)
Issued 9 October 2003
Resolved
Remove and repair/clean all sea strainers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 November 2003
Resolved 16 October 2003
Resolution: CLEARED
Lifesaving
Issued 4 December 1997
Resolved
RENEW RETRORELECTIVE MATERIAL ON LIFE JACKETS
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Lifesaving
Issued 4 December 1997
Resolved
PROVIDE CG APPROVED FIRST AID KIT
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Electrical
Issued 4 December 1997
Resolved
PROVIDE RUBBER MAT IN FRONT OF SWITHCBOARD
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Construction/Loadline
Issued 7 November 1995
Resolved
RENEW ALL WASTED BILGE SUCTION PIPING IN LAZARETTE.
Condition: Unknown
Due 8 November 1995
Resolved 9 November 1995
Fire Fighting
Issued 7 November 1995
Resolved
INSTALL CORRECT FIRE EXTINGUISHER BRACKETS.
Condition: Unknown
Due 9 November 1995
Resolved 9 November 1995
Lifesaving
Issued 7 November 1995
Resolved
PROPERLY SECURE THE PORT AND STBD BUOYANT APPARATUS.
Condition: Unknown
Due 8 November 1995
Resolved 9 November 1995
Documentation
Issued 27 March 1995
Resolved
COMPLETE ONE OF THE TWO ALTERNATIVES IN MARINE SAFETY CENTER LETTER DATED 23 MARCH 95.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Documentation
Issued 28 September 1994
Resolved
PROVE PROPER APPLICATION OF DRAFT MARKS. PROVE VESSEL MEETS MINIMUN DRAFT REQUIREMENTS AS PER STABILITY LETTER IN ALL LOADED CONDITIONS.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Construction/Loadline
Issued 28 September 1994
Resolved
PROVIDE PROPOSAL FOR AND MAKE REPAIRS TO DAMAGED SIDESHELL AND SUPPORTING FRAMES IN STEERING COMPARTMENT, STARBOARD SIDE, NEAR TRANSOM.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Construction/Loadline
Issued 28 September 1994
Resolved
Renew as original and NDT 3, 18" X 18" inserts along the port side sideshell and 1, 18" X 18" insert along the starboard side sideshell.
Condition: Unknown
Due 9 November 1994
Resolved 15 November 1994
Engineering
Issued 28 September 1994
Resolved
PROVE PROPER OPERATION OF STARBOARD MAIN ENGINE LUBE OIL PRESSURE GAUGE, AND BOTH REDUCTION GEAR OIL PRESSURE GAUGES IN WHEEL HOUSE.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Electrical
Issued 28 September 1994
Resolved
REMOVE MULTIPLE DEAD-ENDED WIRE RUNS FROM STEERING COMPARTMENT.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Documentation
Issued 28 September 1994
Resolved
CONDUCT A DEADWEIGHT SURVEY IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR AND SUBMIT CALCULATIONS TO COMMANDANT (G-MSC) FOR REVIEW OF THE WEIGHT CHANGES MADE DURING THIS INSPECTION. (REMOVAL OF THE CENTER ENGINE AND TYPE II MSD AND INSTALLATION OF THE NEW HOLDING TANK)
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Engineering
Issued 28 September 1994
Resolved
REMOVE OR COVER UNUSED CENTER ENGINE ALARM PANEL IN WHEELHOUSE.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Electrical
Issued 28 September 1994
Resolved
REMOVE WATER FROM FROM ENGINE ROOM BATTERY BOXES.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Navigation
Issued 28 September 1994
Resolved
REMOVE OR PROVE PROPER OPERATION OF PORT AND STARBOARD SHAFT TACHOMETERS.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Engineering
Issued 28 September 1994
Resolved
PROPERLY LABEL SERVICE GENERATOR ALARM PANEL IN PILOT HOUSE.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Lifesaving
Issued 28 September 1994
Resolved
INSTALL WOODEN BATTENS BETWEEN ALL BUOYANT APPARATUS'.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Lifesaving
Issued 28 September 1994
Resolved
PLACE PYROTECHNIC DISTRESS SIGNALS IN WATERTIGHT CONTAINER.
Condition: Unknown
Due 1 November 1994
Resolved 8 November 1994
Construction/Loadline
Issued 28 September 1994
Resolved
Renew as original and NDT 1, 4' X 4' insert along bottom plate of port sidetransom and 1, 18" X 18" insert along bottom plate stbd side.
Condition: Unknown
Due 9 November 1994
Resolved 15 November 1994
Construction/Loadline
Issued 28 September 1994
Resolved
SERVICE AND PROVE PROPER OPERATION OF ALL MAIN DECK SCUTTLE CLOSURE DEVICES.
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Documentation
Issued 24 January 1994
Resolved
Paint proper home port on stern of vessel.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 24 January 1994
Resolved
Remove deadbolts on both inside and outside of the port and starboard pilothouse doors and install latches that can be opened from both sides of the doors.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 24 January 1994
Resolved
Remove deadbolts from port and starboard doors leading from passenger area to pilot house.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Electrical
Issued 24 January 1994
Resolved
Properly wire A/C unit circulating pump in #3 void.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Accommodation/Occupational Safety
Issued 17 November 1993
Resolved
Prove proper operation of mens and womens toilets.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 17 November 1993
Resolved
RENEW HARDWARE FOR PIPE HANGER AT FRESH WATER FILL PIPE BELOW MAIN DECK IN THIRD VOID.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Accommodation/Occupational Safety
Issued 17 November 1993
Resolved
Cap urinal piping from men's toilet.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Engineering
Issued 17 November 1993
Resolved
Renew inoperative port main engine reduction gear oil pressure guage on thebridge.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Accommodation/Occupational Safety
Issued 17 November 1993
Resolved
PROPERLY REPAIR BROKEN WELDS AT DECK TO HANDRAILS ON PORT AND STBD SIDES OFBRIDGE.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 17 November 1993
Resolved
Provide a waterlight for each buoyant apparatus on the port side.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 17 November 1993
Resolved
PROVE PROPER OPERATION AND CONDITION OF FORWARD PASSENGER AREA ESCAPE HATCH. RENEW AND PROPERLY INSTALL RUBBER HATCH GASKET. CLEAN, SERVICE AND LUBRICATE ALL CLOSURE DOGS.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 17 November 1993
Resolved
RENEW BROKEN BILGE SUCTION STRAINER ASSEMBLY WITHIN THIRD VOID.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Engineering
Issued 17 November 1993
Resolved
RENEW TURBOCHARGER HEAT BLANKETS ON STBD MAIN ENGINE.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Engineering
Issued 17 November 1993
Resolved
RENEW EXHAUST INSULATION BLANKETS WITHIN FOURTH VOID.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 17 November 1993
Resolved
RENEW FRESH WATER SUCTION PIPE HANGER AND HARDWARE IMMEDIATELY AFT AND BELOW FRESH WATER TANK.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 17 November 1993
Resolved
PROPERLY GRIND AND REPAIR 4 WELDED JOINTS AS MARKED WITHIN FORWARD VOID.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 17 November 1993
Resolved
PROPERLY GRIND AND REPAIR 5 WELDED JOINTS AS MARKED WITHIN SECOND VOID.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 17 November 1993
Resolved
PROPERLY GRIND AND REPAIR 2 WELDED JOINTS AS MARKED IN THIRD VOID.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Documentation
Issued 17 November 1993
Resolved
Carry on board an approperate waste management plan.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Accommodation/Occupational Safety
Issued 17 November 1993
Resolved
REPAIR STBD DRAIN PIPING FROM FEMALE TOILET IN FOURTH VOID.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Accommodation/Occupational Safety
Issued 17 November 1993
Resolved
PROVE PROPER OPERATION OF MSD OR INSTALL HOLDING TANK.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Lifesaving
Issued 17 November 1993
Resolved
Complete satisfactory man overboard drill.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Accommodation/Occupational Safety
Issued 17 November 1993
Resolved
Install proper trap in men's sink drain.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Electrical
Issued 17 November 1993
Resolved
Renew blocking materal in all battery boxes.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Lifesaving
Issued 17 November 1993
Resolved
Install proper capacity sign in passenger area - second deck: max. capacity125.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 18 November 1992
Resolved
Renew as original the port aft mooring cleat that is missing.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Lifesaving
Issued 18 November 1992
Resolved
Provide a suitable means for retrieving a victim that has fallen overboard.This is to be in addition to the rescue ladder already in use.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Lifesaving
Issued 18 November 1992
Resolved
Provide onboard a rescue swimmers harness to be used by a member of the crew when there is a man overboard.
Condition: Unknown
Due 18 November 1992
Resolved 18 November 1992
Electrical
Issued 27 October 1992
Resolved
Permanently wire back to a breaker panel both port/stbd engineroom fan motors.
Condition: Unknown
Due 21 November 1992
Resolved 23 November 1992
Accommodation/Occupational Safety
Issued 27 October 1992
Resolved
In #4 void, replace stbd. side fan motor and prove proper operation.
Condition: Unknown
Due 21 November 1992
Resolved 23 November 1992
Construction/Loadline
Issued 27 October 1992
Resolved
Remove temporary deck stanchions in #2 void on both port and stbd sides.
Condition: Unknown
Due 21 November 1992
Resolved 23 November 1992
Accommodation/Occupational Safety
Issued 27 October 1992
Resolved
Submit plans showing marine sanitation device (MSD) that Ports Authority intends to install on the vessel. MSD must comply with 33 CFR 159. MSD pumps are not working on current system requiring tank to be manually pumped out. Current set-up does not create pollution or health hazard.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Accommodation/Occupational Safety
Issued 21 November 1991
Resolved
INSTALL AND PROVE PROPER OPERATION OF P/S ENGINROOM SUPPLY BLOWERS THAT HAVE BEEN REMOVED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Electrical
Issued 21 November 1991
Resolved
PROPERLY CONNECT ALL LOOSE WIRING ON UPPER DECK LIGHTING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Electrical
Issued 21 November 1991
Resolved
INSTALL LIGHTBULB AND GLOBE IN FEMALE RESTROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Electrical
Issued 21 November 1991
Resolved
INSTALL ALTERNATOR BELT GUARD ON PORT MAIN DIESEL ENGINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Accommodation/Occupational Safety
Issued 21 November 1991
Resolved
MAKE PERMANENT REPAIRS TO F/W PUMP SUCTION AND DISCHARGE PIPING IN ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Lifesaving
Issued 21 November 1991
Resolved
SEPERATE ALL BUOYANT APPARATUS WITH SPACERS IAW 46CFR180.20-1(A)(7)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Engineering
Issued 21 November 1991
Resolved
RENEW ALL TORN OR DETERIORATED EXHAUST LAGGING ON ALL MAIN DIESEL ENGINES._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Engineering
Issued 21 November 1991
Resolved
PROVE PROPER OPERATION OF FUEL OIL SHUT-OFF VALVE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Construction/Loadline
Issued 2 October 1991
Resolved
IN THE #1 VOID GAUGE AND REWELD EIGHT CRACKED WELDS LOCATED AN OVERHEAD BETWEEN #4 AND #7 TRANSVERSE FRAMES AS MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 2 October 1991
Resolved
IN THE #1 VOID WELD ALL FRAMING IN WAY OF DECK INSERT. INSERT IS LOCATED BETWEEN #1 AND #3 OVERHEAD TRANSVERSE FRAMES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Accommodation/Occupational Safety
Issued 2 October 1991
Resolved
REMOUNT TRANSFORMER FOR MARINE SANITATION DEVICE LOCATED ON PORTSIDE IN AFTSTEERING GEAR VOID._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 2 October 1991
Resolved
DUE TO RECENT PROBLEMS WITH VESSELS HULL AND THE UN-SHELTERED WATERS OF SONDA DE VIEQUES, THE VESSEL WILL UNDERGO A DRYDOCK INSPECTION EVERY YEAR. THE NEXT DRYDOCK INSPECTION WILL BE 02 OCT 92. ALSO IN ADDITION EVERY SIX MONTHS WE WILL NEED TO INSPECT THE INTERIOR OF THE HULL.
Condition: Unknown
Due 2 October 1991
Resolved 2 October 1991
Construction/Loadline
Issued 2 October 1991
Resolved
GAS FREE, USING A CERTIFIED MARINE CHEMIST THE AFT STEERING COMPARTMENT ANDMAKE SPACES AVAILABLE FOR COAST GUARD INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Electrical
Issued 2 October 1991
Resolved
PROVIDE BULBS AND PROTECTIVE CAGES FOR ALL LIGHT FIXTURES IN AFT STEERING VOID._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1991
Resolved 8 October 1991
Construction/Loadline
Issued 21 April 1991
Resolved
DUE TO RECENT PROBLEMS WITH VESSELS HULL AND THE UN-SHELTERED WATERS OF SONDA DE VIEQUES. THE VESSEL WILL UNDERGO A DRYDOCK INSPECTION EVERY YEAR._x001C_THE NEXT DRYDOCK INSPECTION WILL BE 30 SEPT 91. ALSO IN ADDITION EVERY SIX MONTHS WE WILL NEED TO INSPECT THE INTERIOR OF THE HULL._x001C_
Condition: Unknown
Due 21 April 1991
Resolved 21 April 1991
Construction/Loadline
Issued 11 February 1991
Resolved
VESSEL MAY NOT CARRY PASSENGERS UNTIL A STRUTURAL HULL ANALYSIS REPORT HAS BEEN SUBMITTED TO THIS OFFICE AND PERMENANT REPAIRS ENCLUDING EXSTINSIVE FRAME REPLACEMENT AND POSSIBLY ADDITIONAL FRAMING FOR ADDED HULL STRENGHT HAS BEEN COMPLETED IN #2, #3 AND ENGINEROOM COMPARTMENTS.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Accommodation/Occupational Safety
Issued 26 November 1990
Resolved
MAKE ALL FIRE DAMPNERS TO ENGINEROOM COMPARTMENT OPERATIONAL AND TEST IN PRESENCE OF CG INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Lifesaving
Issued 26 November 1990
Resolved
RECONNECT AND TIE PROPERLY ALL BOUYANT APPARATUS ONBOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Construction/Loadline
Issued 28 February 1990
Resolved
DRYDOCK VESSEL AND REPAIR CRACK AS MARKED IN BOTTOM SHELL PLATE IN #2 VOID BETWEEN 5TH AND 6TH BOTTOM LONG TO PORT IN WAY OF THE 1ST TRANSVERSE FRAME AFT OF FWD BUL;KHEAD. VESSEL IS NOT TO BE OPERATED UNTIL REPAIRS HAVE BEENMADE.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Accommodation/Occupational Safety
Issued 28 November 1989
Resolved
MAKE OPERATIONAL VESSELS TYPE II SEWAGE TREATMENT PLANT BY 15DEC89.
Condition: Unknown
Due 28 November 1989
Resolved 28 November 1989