MAURY USCG vessel records Sign in
← All vessels

PACIFIC SPIRIT

PACIFIC SPIRIT is a 1987 freight ship. The Coast Guard has recorded 17 inspections since 1987, most recently in July 2011, along with 14 deficiencies and 2 operational controls.

Records from 1987 to 2011. Most recent: operational control imposed, 8 July 2011.

Built
1987
Last inspected
8 July 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8600193 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
295713
Flag
LIBERIA
—
Maury page id
psix-295713

Inspections, by type

…with no type recorded15
Years with a record 11 calendar years (1987–2011)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it53578 - Regulatory (Subpart C or D), Gross Ton
19701 - Regulatory (Subpart C or D), Net Ton
21436 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

8 July 2011 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4074072
20 February 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1487923
1 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 287567
27 February 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 287400
1 October 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 528185
10 August 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 431558
29 July 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 431146
28 April 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415321
25 January 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 412205
21 March 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401771
28 August 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 394748
13 February 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 364443
13 February 1994 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 854085
24 September 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 332783
12 April 1988 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 484163
20 December 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 320304
18 December 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 320288

Deficiency record · 14

Engineering
Issued 27 February 2001 Resolved
CLEAN OIL IN CONTAINMENT IN PURIFIER ROOM.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Engineering
Issued 27 February 2001 Resolved
REPLACE/REPAIR FUEL OIL SUPPLY LINE ON #2 GENERATOR, NEEDS REPLACING DUE TOCHAFFING/WEARING OF THE LINE.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Navigation
Issued 27 February 2001 Resolved
EXCESSIVE OIL ON DECK IN STEERING GEAR FLATS.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
System not recorded
Issued 27 February 2001 Resolved
REPAIR HYDRAULIC OIL LEAKS ON #1 AND #2 STEERING GEAR PUMP SHAFT SEALS.
Condition: Unknown
Due 27 March 2001
Resolved 19 February 2002
Resolution: Inspected both saft seal under hdraulic load, both saisfactory.
Unknown
Issued 27 February 2001 Resolved
LEAKING SLUDGE LINE ON #2 FUEL OIL PURIFIER.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 29 July 1999 Resolved
LIFEBOUY WATERLIGHT LOCATED AFT OF PORT-SIDE LIFEBOAT INOPERATIVE.
Condition: Unknown
Due 30 July 1999
Resolved 1 August 1999
Lifesaving
Issued 29 July 1999 Resolved
VESSEL WAS UNABLE TO PROVE PROPER OPERATION OF STEERING FOR PRIMARY LIFESAVING EQUIPMENT, SUBSEQUENT ATTEMPTS TO EXERCISE RUDDER CAUSED BOTH THE PORT AND THE STARBOARD SIDE LIFEBOATS TO BE RENDERED INOPERATIVE IN THEMANNER IN WHICH THEY WERE DESIGNED, VESSEL HELD UNDER SOLAS REGULATIONS.
Condition: Unknown
Due 10 August 1999
Resolved 10 August 1999
Engineering
Issued 28 August 1996 Resolved
Provide operational audible alarm for oily water separator.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Documentation
Issued 28 August 1996 Resolved
Provide a record of Hazmat training for three deck officers.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Documentation
Issued 20 December 1987 Resolved
A VIO OF 33CFR155.750 IN THAT THE OTP REQ BY 33CFR155.720 AND FURTHER DESCRIBED BY REF TO 33CFR154.310 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN LIST OF ECH PRODUCTED XFERED,PROCEDURES FOR EMPTYING CONTAINMENT, CLOSING & OPENING VSL OPENINGS,# OF PERSONS,& DUTY ASSIGNMENTS.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Navigation
Issued 18 December 1987 Resolved
VSL DID NOT HAVE A CURRENT U.S. COAST PILOT (VOLUME 2) ONBOARD. AS REQUIREDBY 33 CFR 164.33 (A)(2)(I). COAST PILOT WAS 1986 EDITION WITH NO CORRECTIONE.G. 3/86 NARRAGANSETT BAY, RI PROHIBITED AREA. VSL TRANSITTED NARRAGANSETTBAY ON 18 DEC 87 DURING A DAYLIGHT TRANSIT. VSL IS 53578 GROSS TONS.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Documentation
Issued 18 December 1987 Resolved
DANGEROUS CARGO MANIFEST WAS MISSING THE FOLLOWING INFORMATION: VESSEL OFFICIAL NUMBER OR CALL SIGN AS REQUIRED BY 49 CFR 176.30 (A)(1).
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Navigation
Issued 18 December 1987 Resolved
VESSELS LOCAL CHARTS (NOAA CHARTS) 13221 AND 13223 NOT CORRECTED AS REQUIRED BY 33 CFR 164.33 (A)(1)(II). E.G. 49/87 DELETE BUOYS A,CC AND SR, ADD LIGHT 3 FL Y 15S. VESSEL TRANSITTED NARRAGANSETT BAY ON 18 DEC 87. VESSEL IS 53578 GROSS TONS.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987
Documentation
Issued 18 December 1987 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. MISSING INFORMATION AS REQUIRED BY 33 CFR 155.750 (A)(1)(I), (2)(III),(3),(4),(5),(6),(9) AND (10). THIS WAS NOTED ON MSO PROVIDENCE FOREIGN FREIGHT VSL EXAM FORM DATED 18 DEC 87. TRANSFER OPERATION WAS NOT IN PROGRESS WHEN DISCREPANCY WAS NOTED.
Condition: Unknown
Due 18 December 1987
Resolved 18 December 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.