Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
7 January 2026
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8283701
6 January 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8050966
28 March 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7890743
18 August 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7800972
20 March 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7658006
14 September 2022
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7560546
10 March 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7409679
11 January 2021
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7118296
18 May 2020
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6961235
11 December 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6872217
14 November 2019
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6848866
26 December 2018
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6602851
21 October 2018
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6566813
21 October 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6575816
30 January 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6347287
23 October 2017
Annual Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6297819
8 December 2016
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6054947
5 January 2016
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5785563
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 January 2026
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Marine Inspector found all portable fire extinguishers expired. 46 CFR 181.500 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2026
Resolved 26 January 2026
Resolution: Received portable fire extinguisher servicing report.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 January 2026
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Marine Inspector found Mariner's medical certificate expired. 46 CFR 10.301 (a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2026
Resolved 26 February 2026
Resolution: Vessel is aware a captain without an up to date medical endorsement can not operate the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2024
Resolved
All flexible fuel lines designed for use with hose clamps must be installed with clamps at both ends of the hose. Main fuel lines only have one clamp on each end. Must rectify to the satisfaction of the USCG OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 6 January 2025
Resolution: Double hose clamps provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2024
Resolved
All cables for electrical installations must meet 46 CFR 111.60-1 and 111.60.11 for marine applications. 12 volt batteries use welding cables as primary power supply. Vessel operator must provide evidence that cables are allowed for marine use IAW federal regulations or replace in kind with approved battery cabling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2024
Resolved 1 May 2025
Resolution: Welding cable removed and boat cable installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2022
Resolved
Ring life buoy grab line weathered; and battery light expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 28 March 2022
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 November 2019
Resolved
Purchase 02 additional hand red flares (total of 6 required) in accordance with 46CFR180.68. Due 14Dec2019.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 21 December 2019
Resolution: Received photo of new flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 December 2018
Resolved
Update active crewmember list for drug and alcohol program. Provide letter of enrollment from consortium.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 February 2019
Resolution: Crew member list updated and enrollment letter provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 December 2018
Resolved
Provide covered battery trays/boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 February 2019
Resolution: Battery covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 December 2018
Resolved
All hands rails cracked welds. Repair welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2019
Resolved 15 February 2019
Resolution: Hand rail repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2018
Resolved
Lower unit siezed causing loss of propulsion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2018
Resolved 22 October 2018
Resolution: New lower unit installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 October 2017
Resolved
Replace expired medical gear.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 26 October 2017
Engineering › Fuel Oil Service System › Hose
Issued 14 December 2016
Resolved
Install metal hose clamps for all flexible fuel hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 10 January 2017
Resolution: Hose clamps properly installed.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 14 December 2016
Resolved
Properly stow batteries and cover terminals.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 10 January 2017
Resolution: Batteries properly stowed and terminals covered.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 December 2016
Resolved
Provide proof of consortium enrollment, i.e. crew list, MIS submission, and enrollment certificate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 10 January 2017
Resolution: Owner of the vessel showed proof of enrollment.