CAP STREETER

CAP STREETER is a 1987 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in April 2026, along with 15 deficiencies and 2 casualty investigations between 2012 and 2021.

Records from 2012 to 2026. Most recent: inspection, 30 April 2026.

Built
1987
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX3809
295974
Flag
UNITED STATES
Maury page id
psix-295974

Documentation record

Registered dimensions (L × B × D)63.6 ft × 24.0 ft × 7.7 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE SHIPBUILDING · SALISBURY, MD, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

30 April 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8358790
5 March 2026 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8314568
12 November 2025 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8267091
31 July 2025 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8199616
24 April 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8118293
7 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8015663
4 April 2024 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7889714
5 February 2024 Construction Oversight · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7867477
17 May 2023 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7683745
17 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7709366
23 March 2023 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7655425
14 March 2022 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7411256
12 December 2021 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7366724
12 December 2021 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7368250
18 March 2021 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7156600
19 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6936079
1 October 2019 Plan Review (Other than "T") · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6840665
16 May 2019 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6686754
28 August 2018 Plan Review (Other than "T") · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6526035
3 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6574840
4 May 2017 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6139006
15 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6088905
15 September 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6001267
7 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5900254
19 April 2016 COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5857537

Deficiency record · 15

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2026 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Engine room escape hatch not marked on main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2026
Resolved 30 April 2026
Resolution: Escape hatch marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2026 Resolved
All portable fire extinguishers installed on vessels shall be of an approved type. Aft main deck CO2 and pilothouse extinguishers not mounted with approved brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2026
Resolved 30 April 2026
Resolution: Correct bracket installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 April 2025 Resolved
Fire load calculations must be submitted to the Marine Safety Center when the OCMI determines based on the quantity of combustibles present in a high risk service space may exceed 7.5 lbs of combustibles per square foot of deck area. Voids #2 and #3 contain a high volume of combustibles and is being used a storage changing the space designation from aux machinery to service space. Submit fire load calculations to Marine Safety Center to determine the fire load in #2 and #3 void and install structural fire protection as may be required OR remove all combustibles from the #2 and #3 voids.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2025
Resolution: Witnessed satisfactory removal of combustible material from void spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 April 2024 Resolved
An extension cord was found being used in a permanent application. Remove extension cord as a permanent application. 46 CFR 183.10-20(a)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
Resolution: Extension cord was removed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 April 2024 Resolved
A steering system pin connecting the tiller to the hydraulic ram is missing its retaining pin. Install new retaining pin. 46 CFR 182.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
Resolution: A new retaining pin was installed.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 March 2023 Resolved
Vessel draft marks need to be repainted. Ensure draft marks are painted fwd/aft and port/stbd.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 17 May 2023
Resolution: Draft marks have been painted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2023 Resolved
Install drip shields on 3 battery chargers in port side engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 17 May 2023
Resolution: Drip shields were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2023 Resolved
Install knockout cover plug for "dress ship lights" j-box on aft bridge bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 17 May 2023
Resolution: Knockouts were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 December 2021 Resolved
Vessel aft generator shut down unexpectedly creating a loss of power event. Vessel shall assess aft generator, make relevant repairs, and test to the satisfaction of local OCMI prior to the carriage of passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2021
Resolved 13 December 2021
Resolution: Vessel made repairs to faulty impeller for cooling system and tested genset under load for one hour to the satisfaction of local OCMI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2020 Resolved
Vessel is missing proper structural fire protection (insulation) in engine. Please replace or repair to the satisfaction of attending marine inspector. 46 CFR 176.25-50
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 3 August 2020
Electrical › Lighting (service) › Lighting Fixture
Issued 7 June 2016 Resolved
Renew light fixtures throughout passenger accomidation spaces with type meeting UL 1598
Due 1 March 2017
Resolved 15 September 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2016 Resolved
Replace missing light covers in paint locker, lower passenger deck & bar. 46 CRF 120.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 7 June 2016
Electrical › Lighting (service) › Outlet Box
Issued 19 April 2016 Resolved
Fix all Electrical outlets throughout vessel. 46 CFR 120.220
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 7 June 2016
Electrical › Electric Supply System (service) › Cable
Issued 19 April 2016 Resolved
Provide metal supports every 24" for all electrical wiring in engineroom- no plastic tie's. 46 CFR 120.340(b)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 7 June 2016
Stability › Weathertight Integrity › General
Issued 19 April 2016 Resolved
Replace broken window port side pilot house. 46 CFR 116.1010
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 7 June 2016

Casualty record · 2

12 August 2012Routine · role: Involved in a Marine Casualty · activity 4470373
12 December 2021Routine · role: Involved in a Marine Casualty · activity 7368250
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.