HEY BABE

HEY BABE is a 2001 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2019, most recently in May 2026, along with 30 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 5 May 2026.

Built
2001
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 May 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK7875
Flag
UNITED STATES
Maury page id
psix-29645

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 19 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

5 May 2026 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8367468
11 June 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8157068
5 December 2024 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8043717
1 February 2024 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7869379
7 November 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824111
15 September 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7790721
7 November 2022 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7602500
15 September 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7622922
22 August 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7541027
11 August 2021 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7283399
23 March 2021 Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161224
7 August 2020 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7026462
5 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6849474
21 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6839083
6 March 2019 COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637378

Deficiency record · 30

05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 May 2026 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel's FCC Safety Radiotelephony Certificate was expired. Vessel's route is limited to 20 nm. 46 CFR 184.502 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 June 2026
Resolution: Vessel rep had certified FCC technician inspect and issue new FCC Safety radio telephony certificate to include satelite phone
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 May 2026 Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel's insulation in the aft engine room and engine room access panels insulation damaged. Requires replacement 46 CFR 177.410(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 3 June 2026
Resolution: Confirmed proper replacement of egnine room insulation on access panels and aft portion of engine room overhead
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2026 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2.5 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel is missing one fire bucket. 46 CFR 181.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 3 June 2026
Resolution: Confirmed vessel had 3 proper fire buckets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2026 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Vessel's aft engine room bilge pump did not work in auto. 46 CFR 182.250
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 3 June 2026
Resolution: Witnessed proper function of aft engine room automatic bilge pump
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Vessel's starboard fuel tank shutoff valve does not close completely. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 3 June 2026
Resolution: Witness proper closure of stbd fuel tank shutoff valve
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2026 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Vessel's batteries in the steering compartment were not secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 3 June 2026
Resolution: Confirmed batteries were properly secured and covered
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock... Vessel had several exposed wires above the Port Main Engine. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 3 June 2026
Resolution: Verified proper wire terminations/insulations above port engine
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 June 2025 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is to cease passenger operations until a USCG marine inspection takes place. 46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2025
Resolution: Conducted annual inspection, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel lines. Shutoff valve's handle was rusted and unable to properly close the valve. Show proper operation of the valve.46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2024
Resolved 7 March 2024
Resolution: Received objective evidence of new valve handle installed and operable.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 March 2024 Resolved
Interconnected fire detection system shall be installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel's fire detectors were not interconnected. Install an interconnected fire detectors that meet UL217, be audible and visual, contain independent power source, and alarm on low power.46 CFR 181.450
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 18 March 2024
Resolution: Received objective evidence of approved integrated smoke detectors installed and operable.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 March 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts. Vessels charts were not updated, Provide up to date charts.46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2024
Resolved 18 March 2024
Resolution: Received objective evidence of newly purchased up-to-date charts.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 September 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has exceeded 3 months past anniversary date. Vessel is prohibited from carrying passengers until annual inspection is complete. 46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2023
Resolution: Conducted annual exam on 15SEP23. No major deficiencies identified. Vessel SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2023 Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. Vessels with a keel laid date after March 28, 2022, must include plans for the monitoring device(s) within the plan submissions required in 46 CFR 177.202. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. The monitoring device(s) must: (1) Ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive; (2) Remain operable during the nighttime watch; and (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Vessel has not installed monitoring device to ensure the wakefulness of the watchmen. Vessel has 30 days to install approved system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 December 2023
Resolution: Received evidence that vessel installed watch monitoring device. Seee vessel activity #7622922
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 August 2022 Resolved
All vessels must have navigation lights that are in compliance with Inland Nav Rules. Vessel's Port navigation light was extinguished. Fix/repair Port navigation light. Vessel is restricted to daytime operations until rectified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2022
Resolved 25 August 2022
Resolution: Documentary evidence recieved, deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 August 2022 Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. vessel did not have charts on board. Equip vessel with charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 24 August 2022
Resolution: Rectified deficiency
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 August 2022 Resolved
Gauges to indicate engine revolutions per minute, jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. Stbd engine did not read accurate oil pressure. Fix/ repair oil pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 1 September 2022
Resolution: Deficiency rectified
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 August 2022 Resolved
A vessel must carry either a first-aid kid approved under approval series 160.041 or a kit with equivalent contents. Items required listed in 46 CFR 160.041-4(b)table. Vessel's eye wash in first aid kit expired. Replace eye wash.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 25 August 2022
Resolution: Documentary evidence recieved, deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 August 2021 Resolved
A vessel must carry one floating water light as certificated on COI. Battery connections broken on water light. Replace Water light. Restrict operations to daytime only until replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 2 September 2021
Resolution: Owner provided photgraphic evidence of new Water Light
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 August 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date Charts of large enough scale to make safe navigation. Charts outdated. Replace with up to date Charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 2 September 2021
Resolution: Owner provided photographic evidence of updated charts.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 August 2021 Resolved
Mandatory Chemical Testing Requirements. Consortium crew list is out of date. Provide current crew list from consortium.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 2 September 2021
Resolution: Owner provided photgraphic evidence of up to date consortium list.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2021 Resolved
Vessel must carry a first aid kid approved under approval series 160.041 or a kit with equivalent contents and instructions. Aspirin is expired. Replace with 100 count aspirin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 2 September 2021
Resolution: Owner provided photographic evidence of new aspirin for first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 24 August 2021 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 deg F, must be suitably insulated where necessary to prevent injuries. Turbo has no insulation/heat shield. Insulate to prevent injury.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2021
Resolved 23 September 2021
Resolution: Turbo covers installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019 Resolved
Ring bouy not marked with vessel name. Master used vinyl decals that didn't adhere to surface of ring buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 5 November 2019
Resolution: Ring Buoy was properly labeled. ALL SAT
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 October 2019 Resolved
NAV Rules expired; Obtain current NAV Rules
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 5 November 2019
Resolution: Vessel representative provided his new and up to date rules of the road book. ALL SAT
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 October 2019 Resolved
Coast Pilot expired; obtain current coast pilot
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 5 November 2019
Resolution: Vessel Representative provided his up to date Coast Pilot. ALL SAT
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 23 October 2019 Resolved
Non FCC approved SAT phone on board with no FCC waiver and no SSB radio. Obtain FCC approved satellite phone & waiver in lieu of SSB radio or acquire SSB radio and install.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 14 November 2019
Resolution: Received valid FCC Exemption Certificate.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 October 2019 Resolved
Repair inoperable anchor light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 5 November 2019
Resolution: Vessel successfully tested Anchor Light. ALL SAT
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 October 2019 Resolved
Repair inoperable bilge light for aft bilge pump. Bilge indicator light at operating station was not coming on.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 5 November 2019
Resolution: Vessel Successfuly tested Bilge light for aft bilge pump. ALL SAT
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 October 2019 Resolved
VHF programmed with incorrect MMSI and had no GPS feature; Replace cabin VHF with approved VHF (with GPS feature) and program with correct MMSI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 5 November 2019
Resolution: Vessel successfully provided both VHF stations had correct MMSI number input and satisfactory GPS compliance. ALL SAT
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 October 2019 Resolved
Public address system was not operational.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 23 October 2019
Resolved 23 October 2019
Resolution: Corrected prior to departure

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.