MAURY USCG vessel records Sign in
← All vessels

BELGRACE

BELGRACE is a 1987 tank ship. The Coast Guard has recorded 36 inspections since 1988, most recently in April 2002, along with 21 deficiencies.

Records from 1988 to 2002. Most recent: inspection, 30 April 2002.

Built
1987
Last inspected
30 April 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8313374 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
296831
Flag
LIBERIA
—
Maury page id
psix-296831

Inspections, by type

…with no type recorded25
Years with a record 13 calendar years (1988–2002)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11966 - Simplified, Net Ton
50553 - Displacement, Ton
40890 - Dead Weight, Ton
25457 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

30 April 2002 Letter of Compliance (Initial/Renewal) · Periodic Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1611243
29 April 2002 Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1610744
25 April 2002 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1609501
16 February 2001 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 287276
30 January 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 286712
14 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 76975
13 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 428702
13 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 807374
19 May 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416086
28 December 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 411245
26 December 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1381092
5 July 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 405469
9 April 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 402448
29 January 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 399946
21 February 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 651559
18 February 1996 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 3220
28 November 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 385185
28 November 1995 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 883555
6 September 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 466923
24 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 376613
28 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375695
2 September 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 456279
10 April 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 365938
10 April 1994 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1168051
17 November 1993 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1158734
26 July 1993 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1450784
12 February 1992 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1271067
5 July 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 338098
5 July 1990 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1239258
20 June 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 331048
20 June 1989 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210639
31 October 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 464410
12 July 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 324405
2 February 1988 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 321128
2 February 1988 Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1324929
19 January 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 498166

Deficiency record · 21

Deck/Cargo
Issued 28 December 1997 Resolved
PROVIDE UPDATE DRAEGER TUBES FOR GAS KITS. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Construction/Loadline
Issued 28 December 1997 Resolved
PROVIDE A MARINE CHEMIST TO MAKE BALLAST TANKS GAS FREED. 33. C.F.R. PART 157-140) CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 29 December 1997
Resolved 12 February 1998
Lifesaving
Issued 28 December 1997 Resolved
MAKE PERMANENT REPAIRS TO LIFEBOAT STARBOARD SIDE ROMOTE LOWERING SHEAVE._x001C_ (SOLAS 74 AMENDED CH-III/ REG. 26). CORRECT PRIOR TO NEXT U.S. PORT. PROVIDE LOCAL CG INSPECTOR CLASS SURVEYOR'S REPORT.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Unknown
Issued 28 December 1997 Resolved
CORRECTED
Condition: Unknown
Due 29 January 1998
Resolved 2 January 1998
Electrical
Issued 28 December 1997 Resolved
PROVIDE RUBBER MATTING AROND HIGH VOLTAGE BOXES IN ELECTRICAL STORE ROOM._x001C_ (SOLAS 74 AMENDED REG II-1/45.1) CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Accommodation/Occupational Safety
Issued 28 December 1997 Resolved
MAKE PERMANENT REPAIRS TO LEAK ON MARINE SANITATION DEVICE DISCHARGE PUMP._x001C_(33 C.F.R. 159.7) CORRECT PRIOR TO NEXT U.S. PORT. PROVIDE LOCAL CG INSPECTOR CLASS SURVEYOR'S REPORT.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Engineering
Issued 9 April 1997 Resolved
VESSEL'S AUXILARY COOLING FRESH WATER COOLER HAS TWO SOFT PATCHES IN PLACE.VESSEL IS REQUIRED TO REPAIR PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 7 July 1997
Resolved 7 July 1997
Engineering
Issued 9 April 1997 Resolved
VESSEL'S MAIN LUBE OIL COOLER HAS ONE SOFT PATCH IN PLACE. VESSEL IS REQUIRED TO REPAIR PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 7 July 1997
Resolved 7 July 1997
Accommodation/Occupational Safety
Issued 29 January 1997 Resolved
MARINE SANITATION DEVICE VALVE NOT SURCED TO OVERBOARD PIPING. AS REQUIRED BY 33 C.F.R 159.53(c).
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Deck/Cargo
Issued 29 January 1997 Resolved
VESSELS INERT GAS SYSTEM BLOWER CAPACITY FAILED TO MATAIN REQUIRED O-2% TANKES GAGED AT 15% O-2. AS REQUIRED BY SOLAS 74, AMMENDED, II 2/62.27.1
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Documentation
Issued 28 February 1995 Resolved
SUBMIT CURRENT CERTIFICATE OF FITNESS TO MARINE SAFETY CENTER TO UPDATE CURRENT SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 26 March 1995
Resolved 26 March 1995
Engineering
Issued 28 February 1995 Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 6 March 1995
Resolved 6 March 1995
Accommodation/Occupational Safety
Issued 17 November 1993 Resolved
RENEW HAND RAILS TO DECK LADDERS LEADING TO CARGO TK TOPS AS NEEDED THROUGHOUT THE MAIN DECK.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Engineering
Issued 17 November 1993 Resolved
RENEW TORN FLAME SCREENS TO #2 FORWARD AND AFT FUEL TK VENTS PRIOR TO LOADING BUNKERS, BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Navigation
Issued 5 July 1990 Resolved
US CHART 18645, 18TH EDITION, 11SEP82 NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINERS AS FOLLOWS: 1982-1990 ALL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Navigation
Issued 5 July 1990 Resolved
VESSEL DOES NOT HAVE AN OPERATIONAL ARPA. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Navigation
Issued 5 July 1990 Resolved
US CHART #18649, 53RD,ED NTO CURRENTLY CORRECTED. MISSING NOTICE TO_x001C_ MARINERS CORRECTIONS AS FOLLOWS: 1989: ALL 1990: ALL
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Navigation
Issued 5 July 1990 Resolved
US CHART 18650, 37TH EDITION, 17APR82 NOT CURRENTLY CORRECTED. MISSING_x001C_ NOTICE TO MARINERS AS FOLLOWS: 1982-ALL; 1983-ALL; 1984-ALL; 1985-ALL;_x001C_ 1986-ALL; 1987-ALL; 1988-ALL; 1989-ALL; 1990-ALL_x001C_
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Navigation
Issued 20 June 1989 Resolved
CHARTS 12326 (24TH ED.), 12327 (81ST ED.), 12333 (26TH ED.) AND 12334 (57THED.) ON BOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Navigation
Issued 20 June 1989 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Documentation
Issued 20 June 1989 Resolved
VESSEL COULD NOT PRODUCE A CURRENT RECORD OR EVIDENCE OF A PROPER STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.