Behind this panel: 21 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 21
21 April 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8354098
14 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8251679
5 March 2025
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8088823
20 March 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7883450
10 October 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7808112
25 January 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7626695
26 January 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7386083
24 January 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384551
27 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7339362
5 April 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7169153
2 April 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7168812
1 April 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7173766
3 February 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6901447
23 October 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6841270
23 July 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6759311
8 April 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6657863
19 April 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6394760
21 March 2018
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6375784
25 October 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6294393
6 January 2017
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6066823
27 January 2016
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5804146
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 April 2026
Resolved
Shutoff valves must be fitted in the fuel supply lines. handle was missing and stem was corroded inhibiting operation of fuel shutoff.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2026
Resolved 21 April 2026
Resolution: Replaced valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 April 2026
Resolved
A vessel must be provided with bilge bumps in accordance with Table 182.520(a). Forward port bilge pump was not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2026
Resolved 21 April 2026
Resolution: Replaced bilge pump.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 February 2022
Resolved
Provide Radio Station Authorization Certificate and Radio Telephony certificate. Vessel is restricted to 1,000 ft from shore until valid certificates are provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 15 March 2022
Resolution: Vessel changed routes and doesn't require Radio Telephony Certificate anymore.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2022
Resolved
01 life ring is required on board. The life ring is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2022
Resolved 15 March 2022
Resolution: New lifebuoy installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2022
Resolved
Waterlight is required to have lanyard attached. Lanyard is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2022
Resolved 2 February 2022
Resolution: Vessel rep replaced lanyard. Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 February 2022
Resolved
Charts, tide tables, Coast Pilot, and Light List are expired or not on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2022
Resolved 15 March 2022
Resolution: Updated Charts, tide tables, Coast Pilot, and Light List were purchased and placed on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 January 2022
Resolved
A Certificate of Inspection is valid for 5 years. Vessel's COI expired 12JAN2022 and is not permitted to operate until an inspection for certification has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2022
Resolution: Vessel completed inspction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2020
Resolved
Batteries do not have any protection from exposure to water or spray. Provide protection for batteries.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 24 February 2020
Resolution: Batteries are now in insullated boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2020
Resolved
Dead end wiring found under the helm. Remove or insulate as necessary.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 24 February 2020
Resolution: Dead end wiring removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2020
Resolved
Fuel shut off is not labeled. Provide marking of location and direction of operation.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 3 February 2020
Resolution: New labels were placed on board.
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 January 2017
Resolved
Provide lifejacket donning placard specific for each life jacket carried on-board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 18 January 2017
Resolution: Lifejacket placard provided for both life jackets carried on board.