MAURY USCG vessel records Sign in
← All vessels

WATER TAXI MIAMI 1

WATER TAXI MIAMI 1 is a 1987 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1987, most recently in April 2026, along with 60 deficiencies.

Records from 1987 to 2026. Most recent: inspection, 21 April 2026.

Built
1987
Last inspected
21 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

296939
Flag
UNITED STATES
—
Maury page id
psix-296939

Inspections, by type

…with no type recorded7
Years with a record 34 calendar years (1987–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
3 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 70

21 April 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8354098
14 October 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8251679
5 March 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8088823
20 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7883450
10 October 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7808112
25 January 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7626695
26 January 2022 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7386083
24 January 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384551
27 October 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7339362
5 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7169153
2 April 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7168812
1 April 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7173766
3 February 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6901447
23 October 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6841270
23 July 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6759311
8 April 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6657863
19 April 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6394760
21 March 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6375784
25 October 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6294393
6 January 2017 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6066823
27 January 2016 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5804146
16 December 2015 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5797303
6 October 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5739601
11 July 2012 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4375277
13 January 2012 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4217304
7 October 2008 COI Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3327481
13 April 2007 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3023442
16 August 2006 Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2748867
2 March 2006 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2594586
17 December 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2261466
8 December 2004 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2255760
4 October 2004 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2212684
27 January 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1993703
28 May 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1803999
30 January 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1737364
9 January 2003 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1727615
20 February 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1488215
27 February 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1462184
24 January 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1403287
11 January 2000 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1395335
4 February 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126238
12 January 1999 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415112
15 January 1998 Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 774235
18 March 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094450
23 January 1997 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1101534
15 January 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098886
16 January 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 875818
15 March 1995 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 841651
9 January 1995 Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 835713
15 December 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 844609
23 March 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1166232
20 January 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160829
26 February 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840241
28 January 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 832671
12 January 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 827357
13 July 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 648388
1 July 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134184
21 June 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 948272
22 January 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942930
5 July 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916750
15 February 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 909190
16 January 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 906080
16 January 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253616
7 December 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916062
13 January 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 926664
13 January 1989 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1198683
16 September 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1352971
25 January 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1326841
17 December 1987 Initial Construction-Excluding Oversight
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1321972
1 December 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1013757

Deficiency record · 60

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 April 2026 Resolved
Shutoff valves must be fitted in the fuel supply lines. handle was missing and stem was corroded inhibiting operation of fuel shutoff.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2026
Resolved 21 April 2026
Resolution: Replaced valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 April 2026 Resolved
A vessel must be provided with bilge bumps in accordance with Table 182.520(a). Forward port bilge pump was not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2026
Resolved 21 April 2026
Resolution: Replaced bilge pump.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 February 2022 Resolved
Provide Radio Station Authorization Certificate and Radio Telephony certificate. Vessel is restricted to 1,000 ft from shore until valid certificates are provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 15 March 2022
Resolution: Vessel changed routes and doesn't require Radio Telephony Certificate anymore.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2022 Resolved
01 life ring is required on board. The life ring is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2022
Resolved 15 March 2022
Resolution: New lifebuoy installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2022 Resolved
Waterlight is required to have lanyard attached. Lanyard is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2022
Resolved 2 February 2022
Resolution: Vessel rep replaced lanyard. Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 February 2022 Resolved
Charts, tide tables, Coast Pilot, and Light List are expired or not on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2022
Resolved 15 March 2022
Resolution: Updated Charts, tide tables, Coast Pilot, and Light List were purchased and placed on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 January 2022 Resolved
A Certificate of Inspection is valid for 5 years. Vessel's COI expired 12JAN2022 and is not permitted to operate until an inspection for certification has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 March 2022
Resolution: Vessel completed inspction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2020 Resolved
Batteries do not have any protection from exposure to water or spray. Provide protection for batteries.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 24 February 2020
Resolution: Batteries are now in insullated boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2020 Resolved
Dead end wiring found under the helm. Remove or insulate as necessary.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 24 February 2020
Resolution: Dead end wiring removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2020 Resolved
Fuel shut off is not labeled. Provide marking of location and direction of operation.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 3 February 2020
Resolution: New labels were placed on board.
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 January 2017 Resolved
Provide lifejacket donning placard specific for each life jacket carried on-board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 18 January 2017
Resolution: Lifejacket placard provided for both life jackets carried on board.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 January 2012 Resolved
Complete chemical testing program compliance audit. Chemical testing program was found not in compliance with 46 CFR Part 4 & 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Fire Fighting › Fire Bucket › Capacity
Issued 4 January 2012 Resolved
Provide 3, 2.5 gallon fire buckets as required by 46 CFR 181.610.
Action required: 705 - Other - as specified
Resolved 13 January 2012
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 January 2012 Resolved
Provide required marking of aft life jacket locker.
Action required: 705 - Other - as specified
Resolved 13 January 2012
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 January 2012 Resolved
Make distribution panel weather tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Electrical › Electric Supply System (service) › Battery Charger
Issued 4 January 2012 Resolved
Make proper connections to battery as required by 46 CFR 183.350.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 December 2004 Resolved
Remove all dead end wires from vsl. This is going to be a ongoing project. There are numerous wires runs which are in tight spaces which are not easily accessed. No dead end wires noticed by inspector pose a safety threat.
Action required: 705 - Other - as specified
Due 14 January 2006
Resolved 2 March 2006
Resolution: CLEARED
Engineering › Bilge Water Management System › Hose
Issued 8 December 2004 Resolved
Remove kink from bilge pump discharge hose.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 15 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 December 2004 Resolved
Go thorugh vsl wiring as properly wire IAW good marine practice. Vsl may not be used as return conductor.
Action required: 705 - Other - as specified
Due 14 January 2005
Resolved 15 December 2004
Fire Fighting › Fire Hoses › Number
Issued 27 January 2004 Resolved
Provide hose for portable fire pump. The portable bilge pump is not equipped with a hose for use as fire pump.
Condition: Improper/Lack of Maintenance
Due 27 February 2004
Resolved 15 December 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 January 2004 Resolved
Provide a complete first-aid kit. Current kit is missing splint and tornequet.
Condition: Placed in Improper Service
Due 27 February 2004
Resolved 15 December 2004
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 27 January 2004 Resolved
Provide life jackets to replace the three condemned adult vests, and provide 2 additional child vests.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2004
Resolved 27 January 2004
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2004 Resolved
Make a written request of [name withheld] to ammend the current COI entry limiting the vessel to voyage of less than 30 minutes. The vessel's normal tour is well over 30 minutes. The vessel is equipped with 3 day and 3 night flares and meets the regulation. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Improper/Lack of Maintenance
Due 27 March 2004
Resolved 15 December 2004
Construction/Loadline › Penetrations
Issued 30 January 2003 Resolved
Remove plastic thru hull pieces for all electrical submersible pumps and install aluminum pieces welded in place. LEGACY COMPONENT DESC: Spool pieces
Condition: Improper Installation
Due 14 March 2003
Resolved 21 May 2003
Construction/Loadline › Penetrations
Issued 30 January 2003 Resolved
Repair/replace rubber boots/grommets of which engine controls penetrate. LEGACY COMPONENT DESC: Outboard engine controls
Condition: Improper/Lack of Maintenance
Due 1 March 2003
Resolved 21 May 2003
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 9 January 2003 Resolved
Renew 18 lifejackets or reduce the number of passenger count by same. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2003
Resolved 15 December 2004
Documentation › Markings/Placards › Certificate of Number (state)
Issued 9 January 2003 Resolved
Properly mark the registration number on the hull. LEGACY COMPONENT DESC: Vessel Number (state)
Condition: Improper/Lack of Maintenance
Due 9 February 2003
Resolved 15 December 2004
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 9 January 2003 Resolved
Renew the anchor line. LEGACY COMPONENT DESC: Anchor Rope
Condition: Improper/Lack of Maintenance
Due 9 February 2003
Resolved 15 December 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 January 2003 Resolved
Provide a first aid kit.
Condition: Improper/Lack of Maintenance
Due 9 February 2003
Resolved 15 December 2004
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 January 2003 Resolved
Re-route the fuel vent lines "away from possible ignition sources." LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Due 9 February 2003
Resolved 15 December 2004
Construction/Loadline
Issued 24 January 2001 Resolved
FWD safety railing is missing and railing support stantion is cracked.
Condition: Unknown
Due 29 January 2001
Resolved 30 January 2001
Lifesaving
Issued 12 January 1999 Resolved
PROVIDE 19 ADULT LIFEJACKETS _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Navigation
Issued 23 January 1997 Resolved
Permanently post emergency VHF radio operation placard at control station. Photocopy placard and fax to MSO Miami
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 23 January 1997 Resolved
Post emergency check off list after updating existing list to make it specific to vessel. Fax copy of list to MSO Miami.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997 Resolved
Develop written passenger safety orientation plan and fax copy to MSO Miami.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Electrical
Issued 16 January 1996 Resolved
INSTALL MASTER SWITCH IN POSITIVE BATTERY CABLE FEEDING STARTER.
Condition: Unknown
Due 30 January 1996
Resolved 31 January 1996
Unknown
Issued 16 January 1996 Resolved
COMPLY WITH 46 CFR PART 16, (DRUG PROGRAM).
Condition: Unknown
Due 23 January 1996
Resolved 29 January 1996
Fire Fighting
Issued 16 January 1996 Resolved
B-I FIRE EXT. REQUIRES PIN & SEAL.
Condition: Unknown
Due 23 January 1996
Resolved 31 January 1996
Documentation
Issued 16 January 1996 Resolved
PROCURE "T" REGS, 1994 OR NEWER
Condition: Unknown
Due 16 February 1996
Resolved 18 January 1996
Electrical
Issued 16 January 1996 Resolved
REPAIR 12 VOLT WIRING TO VHF RADIO & HAILER.
Condition: Unknown
Due 23 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 9 January 1995 Resolved
Recap all welds located below the waterline.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Electrical
Issued 20 January 1994 Resolved
SECURE BATTERY TO PREVENT MOVEMENT.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Electrical
Issued 20 January 1994 Resolved
PROVIDE OVERCURRENT PROTECTION FOR #8 CONDUCTOR AT BATTERY.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Construction/Loadline
Issued 28 January 1993 Resolved
REPAIR BY WELDING THE 3/4 INCH FRACTRUE LOCATED 33 INCHES AFT OF THE SECONDPORT THRU HULL, 24 INCHES ABOVE THE WATER LINE.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Construction/Loadline
Issued 28 January 1993 Resolved
RENEW SECOND THRU HULL FITTING FOR BILGE PUMP OVBD ON PORT SIDE.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Construction/Loadline
Issued 28 January 1993 Resolved
UPGRADE INSTALLED 400 GPH ELECTRIC BILGE PUMPS TO PUMPS WITH SUFFICIENT CAPACITY TO PUMP EACH SPACE AT 10 GALLONS PER MINUTE AS REQUIRED BY 46 CFR 182.25-10.
Condition: Unknown
Due 28 January 1993
Resolved 28 January 1993
Engineering
Issued 12 January 1993 Resolved
INSTALL PROPER AEROQUIP TYPE WIRE INSERTED FUEL HOSE AS PER 46 CFR 182.15- 40 (A) (3).
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Lifesaving
Issued 12 January 1993 Resolved
RENEW REFLECTIVE TAPE ON 25 ADULT AND 5 CHILD LIFEJACKETS.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Lifesaving
Issued 12 January 1993 Resolved
RESTENCIL CHILD LIFEJACKET LOCKER.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Electrical
Issued 12 January 1993 Resolved
PUT BATTERY IN PROPER BATTERY BOX.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Accommodation/Occupational Safety
Issued 12 January 1993 Resolved
SECURE LOOSE SEAT.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Accommodation/Occupational Safety
Issued 12 January 1993 Resolved
LABEL EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Accommodation/Occupational Safety
Issued 12 January 1993 Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Accommodation/Occupational Safety
Issued 12 January 1993 Resolved
REPAIR BROKEN PORT RAIL.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Documentation
Issued 21 June 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 June 1992
Resolved 13 July 1992
Lifesaving
Issued 16 January 1991 Resolved
MARK PFD STOWAGE TO INDICATE NUMBER AND TYPE IN CHARACTERS AT LEAST 1 1/2" HIGH.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Documentation
Issued 16 January 1991 Resolved
POST GARBAGE POLLUTION PLACARD ONBD.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Electrical
Issued 16 January 1991 Resolved
PROVE PROPER OPERATION OF ALL ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Engineering
Issued 16 January 1991 Resolved
MARK FUEL SHUT-OFF VALVE LOCATION AND DIRECTION OF OPERATION IN LETTERS AT LEAST 1" IN HEIGHT.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991
Accommodation/Occupational Safety
Issued 16 January 1991 Resolved
PERMANENTLY REPAIR MISSING LOWER COURSES IN RAILING IN VICINITY OF FWD STBDCORNER AND PORT SIDE. PERMANENTLY REPAIR AS TO ORIGINAL THE JUNCTION WHERE STANCHION MEETS MAIN DECK AT PORT SIDE BOARDING GATE.
Condition: Unknown
Due 16 January 1991
Resolved 16 January 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.