MIGHTY SERVANT 1 is a 1983 freight ship. The Coast Guard has recorded 26 inspections since 1988, most recently in June 2026, along with 5 deficiencies and 2 operational controls.

Records from 1988 to 2026. Most recent: inspection, 30 June 2026.

Built
1983
Last inspected
30 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8130875 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA6543
297505
Flag
MALTA
—
Maury page id
psix-297505

Inspections, by type

…with no type recorded14
Years with a record 18 calendar years (1988–2026)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8557 - Convention (Subpart B), Net Ton
40910 - Dead Weight, Ton
29193 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

30 June 2026 PSC A
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8420152
29 June 2026 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8418327
21 April 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7173754
26 December 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6873348
23 December 2019 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6878540
19 December 2019 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6876792
13 December 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6873354
12 December 2011 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4206271
28 October 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3871003
5 March 2008 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3150507
1 March 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3151250
15 June 2007 MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2939068
2 September 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2481908
26 May 2005 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2368996
27 January 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1994263
24 June 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1815178
14 April 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1770165
26 August 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 293164
17 July 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 280044
21 June 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 276024
21 June 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 429627
14 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 399486
7 July 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 379977
10 November 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 362133
24 August 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 345527
7 February 1988 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 438448

Deficiency record · 5

Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2011 Resolved
1299 - Other (Load Lines) - After any survey of the ship under Article 14 has been completed, no change shall be made in the structure, equipment, arrangements, material, or scantlings covered by the survey, without the sanction of the Administration. Vessel has cement box on auxiliary engine cooling water pipe - ICLL 66 (88p) I/15.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2011
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 12 December 2011 Resolved
1760 - Standard discharge connection - To enable pipes of reception facilities to be connected with the ship's discharge pipeline from machinery bilges and from sludge tanks, both lines shall be fitted with standard discharge connection in accordance with Regulation 13. Vessel's standard discharge connection does not comply with Regulation 13 dimensions - MARPOL 73(78) I/13
Condition: Design Flaw
Due 19 December 2011
Resolved 21 December 2011
Construction/Loadline › Penetrations › Gasket
Issued 15 June 2007 Resolved
When vessel submerges during cargo opperations, stern door in port and starboard steering gear rooms are not watertight. Several inches of water was found on deck. SOLAS 1974 (2004 Consolidated Ed.} ch. I/11
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 16 August 2007
Resolution: Received Class report attesting to satisfactory repairs of the doors stated. All tested for efficient closure and rubber packing material found in good condition.
Communications › Alarms/Indicators › General Alarm
Issued 15 June 2007 Resolved
The audible fire and general alarm in the emergency generator room was inoperable. SOLAS 1974 Ch II-2/13 (i) (k)
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 16 August 2007
Resolution: Received Class report attesting to satisfactory repairs of the Fire and General Alarm in the Emergency Generator Room.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 September 2005 Resolved
M/V MIGHTY SERVANT 1 WAS PLACED ON DO NOT DEOART LIST FOR MALFUNCTION OF 5 ALPHA RADIO TELEPHONE
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 September 2005
Resolution: TECHNICAL REPORT WAS APPROVED AND COMMUNICATIONS ARE OPERATIONAL.