MAURY USCG vessel records
← All vessels

ROBIN E

ROBIN E is a 1987 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in June 2026, along with 14 deficiencies and 1 casualty investigation in 2006.

Records from 2006 to 2026. Most recent: inspection, 3 June 2026.

Built
1987
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA6870
297908
Flag
UNITED STATES
Maury page id
psix-297908

Documentation record

Registered dimensions (L × B × D)55.0 ft × 16.0 ft × 8.2 ft
Registered tonnagegross 48 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC W B ENTERPRISES INC · MEDLEY, FL, UNITED STATES · built 1987
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 21 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Net Ton
48 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

3 June 2026 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8390465
18 June 2025 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8126568
13 September 2024 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8001796
18 June 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7969935
16 May 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7701857
19 September 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7582863
13 June 2022 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7476067
9 August 2021 Annual Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7343206
15 September 2020 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7042478
2 October 2019 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6841938
2 October 2018 Examination of Repairs · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6566832
17 September 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6543126
19 September 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6271960
28 June 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6247029
23 March 2017 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6148937
18 October 2016 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6261687
27 September 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6016183

Deficiency record · 14

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Forward inboard mount for starboard engine has a crack in the weld. Make repairs to the satisfaction of CG Marine Inspectors. 46CFR182.100
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 June 2026
Resolution: Vessel made repairs to engine mount. All Sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2024 Resolved
Found exposed wiring in the overhead of the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 10 July 2024
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 August 2021 Resolved
Make vessel available for underway operational testing and demonstration of emergency drills. **All to be witnessed by CG Marine Inspectors, prior to operation/the carriage of passengers.**
Action required: 705 - Other - as specified
Due 9 August 2021
Resolved 1 July 2022
Resolution: completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 August 2021 Resolved
Multiple wiring discrepancies sighted under vessels helm/dash. Correct as agreed upon during inspection.
Action required: 705 - Other - as specified
Due 9 August 2021
Resolved 11 July 2023
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 September 2020 Resolved
Bilge alarm and electric bilge pump found to be not operational. Repair prior to carriage of passengers or make alternate arrangements for checking the spce with the cognizant OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2020
Resolved 15 September 2020
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2020 Resolved
The engineroom bilge piping/manifold fractured. repair/replace & demostrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 16 September 2020
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 September 2020 Resolved
Lazarette fixed bilge pipe corroded at fwd bulkhead. repair/replace and demonstrate proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 9 August 2021
Resolution: replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 October 2019 Resolved
Vessel is not fitted with an anchor light, one must be installed IAW applicable Nav Rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 November 2019
Resolved 23 October 2019
Resolution: installed and witnessed operational test, all sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 September 2018 Resolved
Make proper repairs to wood rot at internal wing void space hatches on both port and starboard side with oversight from CG Marine Inspector prior to next Spring Operating Season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 October 2018
Resolution: Repairs completed, all sat.
Documentation › Markings/Placards › Capacity Marking
Issued 19 September 2017 Resolved
Post maximum passenger limit at entrance to the upper deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 October 2017
Resolved 28 September 2017
Resolution: posted.
Stability › Intact Righting Energy › General
Issued 15 June 2017 Resolved
Vessel is limited to 88 total persons based on weight change during recent vessel modifications.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 18 September 2017
Resolution: cleared based on newly amended COI reflecting 88 total persons maximum.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 March 2017 Resolved
Discovered signs of cooling water leak in stbd wing void outboard viewing well. Will be corrected during hull exam but will need to be verified/cleared during spring visit scheduled for 6 June.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 28 June 2017
Resolution: corrected.
Engineering › Bilge Water Management System › Piping
Issued 27 September 2016 Resolved
Replace wasted bilge suction/piping and rot in space below the galley IWO bilge piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 27 November 2016
Resolution: Received photo confirming repair.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 September 2016 Resolved
Replace rot in space below the galley IWO bilge piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 27 November 2016
Resolution: Received photo confirming repair.

Casualty record · 1

24 July 2006Routine · role: Involved in a Marine Casualty · activity 2723620
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

FIRE BALL (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.