MAURY USCG vessel records Sign in
← All vessels

COASTAL PROGRESS

COASTAL PROGRESS is a 1988 fishing tender. The Coast Guard has recorded 59 inspections since 1988, most recently in February 2025, along with 48 deficiencies, 1 operational control and 7 casualty investigations between 2009 and 2025.

Records from 1988 to 2025. Most recent: inspection, 10 February 2025.

Built
1988
Last inspected
10 February 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8855463 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC6363
298332
Flag
UNITED STATES
303244000
Maury page id
psix-298332

Inspections, by type

…with no type recorded28
Years with a record 21 calendar years (1988–2025)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)243.9 ft × 40.0 ft × 26.5 ft
Registered tonnagegross 1,920 / net 820
ITC dimensions (L × B × D)243.9 ft × 40.0 ft × 26.5 ft
ITC tonnagegross 1,920 / net 820
BuilderFRED SETTOON, INC. · BELLE RIVER, LA, UNITED STATES · built 1988
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 7 April 2026 · expires 31 May 2027
Service, as the file records itFishing Tender
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it820 - Convention (Subpart B), Net Ton
2833 - Dead Weight, Ton
4410 - Displacement, Ton
1920 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR2701MMSI 303244000 · active · compulsorily equipped · granted 24 June 2026, expires 24 June 2036
WDC6363MMSI 303244000 · expired · compulsorily equipped · granted 28 April 2015, cancelled 16 August 2025
WTE8342MMSI 303244000 · cancelled · compulsorily equipped · granted 9 September 1998, cancelled 8 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 59

10 February 2025 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8141989
15 September 2024 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8012865
28 February 2022 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7408788
14 October 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6835807
10 February 2019 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6659369
19 June 2017 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6183317
4 August 2016 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5962969
27 February 2016 Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5825543
14 January 2009 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3397238
10 April 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2621006
25 October 2005 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2521918
6 October 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2509491
27 July 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2441898
25 January 2005 Re-Inspection · MTSA Verification · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2279920
30 July 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2190423
2 July 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2118908
13 January 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2091135
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997292
1 December 2003 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1957082
9 November 2003 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1950328
14 January 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1730373
5 February 2002 Hull Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1483908
7 October 2000 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 121169
29 September 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 822117
1 June 2000 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 278521
22 December 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 812536
9 November 1999 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1460354
16 April 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 791247
5 March 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 802932
11 February 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1469566
5 November 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1441431
10 December 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1396834
24 July 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465928
2 December 1996 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1421234
28 August 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1090150
29 May 1996 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 46525
29 May 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1084350
2 March 1996 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 121046
18 January 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1184680
9 January 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1187030
15 December 1995 Re-Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359002
11 August 1995 Damage Survey · Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1186118
28 July 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 872286
21 July 1995 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 44390
8 July 1995 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 883144
14 June 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1187243
10 April 1995 MARPOL Annex II Examination · Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1409271
4 April 1995 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 96118
8 March 1995 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 861858
28 February 1995 Damage Survey · Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1367297
17 February 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 122928
12 February 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 146138
10 January 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 374137
5 December 1994 Hull Examination · MARPOL Annex V Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1394188
6 February 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 109060
30 January 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 130639
30 September 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 645100
26 September 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 135068
29 February 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1030091

Deficiency record · 48

Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 5 February 2002 Resolved
INSTALL BLANKS IN COVER OF ENGINEROOM 120/240V DISTRIBUTION PANEL.
Condition: Unknown
Due 5 February 2002
Resolved 5 February 2002
Resolution: COMPLETED DURING INSPECTION.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 February 2002 Resolved
DEAD END ELECTRICAL CABLE TO HYDRALIC OIL TANK HEATING ELEMENT.
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Resolution: CORRECTED DURING INSPECTION.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 February 2002 Resolved
PROPERLY MOUNT PORT MAIN ENGINE LOWER AIR STARTER.
Condition: Improper/Lack of Maintenance
Due 5 February 2002
Resolved 5 February 2002
Resolution: CORRECTED PRIOR TO COMPLETION OF INSPECTION.
Lifesaving
Issued 5 November 1998 Resolved
Provide and install (2) quick release ring buoys on navigation bridge with attached self activating smoke signals.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Engineering
Issued 5 November 1998 Resolved
Provide, install & prove proper operation of remotely operated fuel shutoffvalves for fuel oil service tanks.
Condition: Unknown
Due 16 December 1998
Resolved 16 December 1998
Fire Fighting
Issued 2 December 1996 Resolved
REPORTS OF INSPECTION BY WESTERN FIRE OF THE FIXED CO2 AND PORTABLES DUE INOFFICE BY 05 DEC96.
Condition: Unknown
Due 5 December 1996
Resolved 13 December 1996
Documentation
Issued 15 December 1995 Resolved
Provide a copy of ABS Cargo Gear Safety Certificate.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Fire Fighting
Issued 15 December 1995 Resolved
Provide fire axes for two fireman outfits.
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Construction/Loadline
Issued 15 December 1995 Resolved
Restore watertight integrity on #1 and #8 WTD's.
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Construction/Loadline
Issued 15 December 1995 Resolved
Mark escape hatch out of engineroom to main deck.
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Electrical
Issued 15 December 1995 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM/SHUTDOWN, AND HIGH WATER TEMP.ALARM ON #1 GENERATOR.
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Deck/Cargo
Issued 15 December 1995 Resolved
PROVE PROPER OPERATION OF THE OWS ALARM INDICATOR TO ACTIVATE AT 15PPM.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Construction/Loadline
Issued 15 December 1995 Resolved
Mark watertight door at frame 70 "Doors shall not be opened while at sea." as required by vessel stability letter.
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Navigation
Issued 15 December 1995 Resolved
Prove proper operation of port bridge VHF radio. Microphone is missing.
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Navigation
Issued 15 December 1995 Resolved
Swing ship and provide updated compass deviation card.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Navigation
Issued 15 December 1995 Resolved
Prove proper operation of navigation light alarm panel._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Electrical
Issued 15 December 1995 Resolved
INSTALL SLIDE BAR ON CONTROL PANEL TO PREVENT BOTH GENERATORS FROM BEING INTHE ON POSITION AND OPERATING SIMULTANEOUSLY.
Condition: Unknown
Due 15 January 1996
Resolved 9 January 1996
Construction/Loadline
Issued 11 August 1995 Resolved
Make repairs to weeping weld in the side shell in way of frame No. 7 in thestarbord chain locker prior to departure from Dutch Harbor.
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Documentation
Issued 14 June 1995 Resolved
SUBMIT APPROVED PLANS IN ACCORDANCE WITH NVIC 10-81 CHANGE 1. EIGHT PLANS HAVE BEEN SUBMITTED FOR REVIEW TO MSC.
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995
Engineering
Issued 28 February 1995 Resolved
MAKE PERMANENT REPAIRS OR REPLACE IN KIND AIR THROTTLE CONTROL DEHUMIDIFIER.
Condition: Unknown
Due 8 March 1995
Resolved 10 March 1995
Deck/Cargo
Issued 28 February 1995 Resolved
REPLACE TO ORIGINAL CONDITION VSL'S AFT PORT CARGO BOOM; INCLUDING GOOSENECK, KING PIN, & CONNECTION DEVICES.
Condition: Unknown
Due 1 March 1995
Resolved 2 March 1995
Deck/Cargo
Issued 28 February 1995 Resolved
REPLACE TO ORIGINAL CONDITION DAMAGED LOOSE GEAR ITEMS OF VSL'S AFT STARBOARD CARGO BOOM.
Condition: Unknown
Due 1 March 1995
Resolved 2 March 1995
Deck/Cargo
Issued 28 February 1995 Resolved
CONDUCT PROOF TEST FOR CARGO BOOM AFT UNIT IAW 46 CFR 91.37-40. TEST SHALLBE WITNESSED BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 1 March 1995
Resolved 2 March 1995
Navigation
Issued 28 February 1995 Resolved
REPAIR GYRO COMPASS & PROVE OPERATION.
Condition: Unknown
Due 8 March 1995
Resolved 10 March 1995
Deck/Cargo
Issued 28 February 1995 Resolved
REPLACE IN KIND DAMAGED HYDRAULIC PIPING FOR AFT STARBOARD CARGO BOOM.
Condition: Unknown
Due 1 March 1995
Resolved 2 March 1995
Documentation
Issued 5 December 1994 Resolved
PRIOR TO OPERATING AS A CERTIFICATED FREIGHT VESSEL, CLEAR OUTSTANDING REQUIREMENTS ISSUED 17 OCT 1988.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Documentation
Issued 5 December 1994 Resolved
SUBMIT PLANS IN ACCORDANCE WITH NVIC 10-81 CHANGE 1 (NOTE LAST PARAGRAPH ONPAGE 3 OF NVIC) PLANS MUST BE SUBMITTED AS BUILT.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994 Resolved
PERMANENTLY INSTALL A VAPOR TIGHT ENCLOSURE AROUND THE BATTERIES CURRENTLY LOCATED IN FORE PEAK STORES. EQUIPMENT INSIDE ENCLOSURE MUST BE INTRINSICALLY SAFE. POWER VENTILATION MUST BE IAW 46 CFR 111.15-10
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Electrical
Issued 5 December 1994 Resolved
MOVE THE EMERGENCY SOURCE OF POWER OUTSIDE THE ENGINE ROOM.
Condition: Unknown
Due 5 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 5 December 1994 Resolved
INSTALL INDEPENDANT BILGE SUCTION FOR THE ENGINE ROOM.
Condition: Unknown
Due 5 January 1995
Resolved 6 January 1995
Navigation
Issued 5 December 1994 Resolved
INSTALL CHANGE OVER INSTRUCTIONS AS PER 46CFR97.37-33 FOR STEERING GEAR.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Navigation
Issued 5 December 1994 Resolved
PROVIDE AUDIBLE ALARM FOR STEERING POWER FAILURE ON BRIDGE.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Documentation
Issued 5 December 1994 Resolved
SUPPLY DATA ON SOLID BALLAST INSTALLATION. IE: DATE INSTALLED, AMOUNT INSTALLED, AND TYPE OF MATERIAL.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Electrical
Issued 5 December 1994 Resolved
INSTALL EMERGENCY LIGHTING IN CO2 STORAGE ROOM AND ATOP LADDER LEADING FROMTHE ENGINE ROOM.
Condition: Unknown
Due 5 January 1995
Resolved 6 January 1995
Fire Fighting
Issued 5 December 1994 Resolved
PRIOR TO OPERATING AS A CERTIFICATED FREIGHT VESSEL, THE FIRE MAIN SYSTEM MUST BE ABLE TO BE ENERGIZED FROM THE BRIDGE SO THAT THE ENTIRE FIREMAIN CAN BE ENERGIZED.
Condition: Unknown
Due 5 January 1995
Resolved 7 January 1995
Navigation
Issued 5 December 1994 Resolved
TEST LOW OIL RESERVOIR ALARM.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Navigation
Issued 5 December 1994 Resolved
INSTALL A SOUND POWERED PHONE SYSTEM IAW 46CFR113.30 AS REQUIRED BY 46CFR 96.05-1.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Fire Fighting
Issued 5 December 1994 Resolved
PRIOR TO OPERATING AS A CERTIFICATED FREIGHT VESSEL, INSTALL A FIRE STATIONTO COVER THE AFT DECK AREA AND INSTALL A SECOND FIRE STATION IN THE ENGINE ROOM.
Condition: Unknown
Due 5 January 1995
Resolved 7 January 1995
Documentation
Issued 5 December 1994 Resolved
WHILE VESSEL IS OPERATING AS A CERTIFICATED FREIGHT VESSEL, IT IS NOT PERMITTED TO TRANSFER VESSELS FUEL OIL AS CARGO. UNTIL APPROPRIATE ENDORSEMENT IS PLACED ON COI.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Documentation
Issued 5 December 1994 Resolved
PRIOR TO OPERATING AS A CERTIFICATED FREIGHT VESSEL, SUBMIT TIME SCHEDULE FOR COMPLETION OF CG-835'S 6-21 ISSUED 05DEC94.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Lifesaving
Issued 5 December 1994 Resolved
FINALIZE LAUNCHING PLAN FOR RESCUE BOAT. IF TO BE MOVED TO AN AREA FOR LAUNCHING THIS AREA IS TO BE DESIGNATED FOR THAT PUPOSE ONLY SO THAT CARGO IS NOT STORED IN THAT AREA.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Lifesaving
Issued 5 December 1994 Resolved
INSTALL HOISTING BRIDLE FOR THE RESCUE BOAT.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Navigation
Issued 5 December 1994 Resolved
INSTALL ENGINE ORDER TELEGRAPH IAW 46CFR113.35 AS REQUIRED BY 46CFR96.05-1.
Condition: Unknown
Due 5 January 1995
Resolved 6 January 1995
Electrical
Issued 5 December 1994 Resolved
INSTALL ELECTRICAL OUTLETS IN ENGINE ROOM IAW 46CFR111.79-5
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Lifesaving
Issued 5 December 1994 Resolved
INSTALL RING BOUYS AS REQUIRED BY 94.43-15(a).
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 5 December 1994 Resolved
PROVE HATCHES FOR CARGO HOLDS ARE WATERTIGHT.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Lifesaving
Issued 5 December 1994 Resolved
CONDUCT FIRE, ABANDON SHIP, AND MAN OVERBOARD DRILLS.
Condition: Unknown
Due 4 January 1995
Resolved 6 January 1995
Navigation
Issued 5 December 1994 Resolved
INSTALL NAVIGATION LIGHTS IAW 46CFR111.75-17 AS REQUIRED BY 96.05-1.
Condition: Unknown
Due 5 January 1995
Resolved 6 January 1995

Casualty record · 7

14 January 2009Routine · role: Involved in a Marine Casualty · activity 3397238
27 February 2016Routine · role: Involved in a Marine Casualty · activity 5825543
4 August 2016Routine · role: Involved in a Marine Casualty · activity 5962969
19 June 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6183317
10 February 2019Routine · role: Involved in a Marine Casualty · activity 6659369
15 September 2024Routine · role: Involved in a Marine Casualty · activity 8012865
10 February 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8141989
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.