Records in 2003. Most recent: inspection, 22 May 2003.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Electrical › Lighting (service)
Issued 29 April 2003
Resolved
03 light covers missing from lights located in bosun's locker. ILO 147. Correct prior to next U.S. port after sailing foreign. LEGACY COMPONENT DESC: Light Covers
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2003
Resolution: Received proper documentation satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 29 April 2003
Resolved
02 manifold connections for main engine lube oil, located on fantail, must have permanent containment. 33 CFR 156.310, 33 CFR 155.320. Correct prior to next LUBE OIL bunkering, in a U.S. port or waterway. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper Installation
Action required: 703 - Prior to bunkering operations
Resolved 18 May 2003
Resolution: Received proper documentation satisfying requirement.
Communications › Alarms/Indicators
Issued 29 April 2003
Resolved
Audio and visual alarm must be present on the bridge for an emergency loss of power for the steering gear. Solas 74(81 Amendments), Ch. II-1, Reg. 29.5.2. Correct prior to departure from port, have class society attest to satisfactory repairs. LEGACY COMPONENT DESC: Steering Failure Alarm System
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2003
Resolution: Rcvd class survey rpt, attesting to the satisfactory repairs of the steering failure audio alarm on the bridge. Def. cleared.
Accommodation/Occupational Safety › Occupational Safety
Issued 29 April 2003
Resolved
Fire door for passageway on crew accomodation deck is missing it's handle. ILO 147. Correct prior to departure from port to the satisfaction of the class society. LEGACY COMPONENT DESC: Fire door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2003
Resolution: Rcvd class survey rpt, attesting to the installation of the msg handle & to the proper operation of the same. Def. cleared.
Operations/Management › Pollution
Issued 29 April 2003
Resolved
Oil product observed leaking from stern propulsion area causing a sheen on the water. Solas 74 (81 Amendments), CH. II-1, Reg. 29.2.1. Correct prior to departure from port, to the satisfaction of the class society. LEGACY COMPONENT DESC: Control of Discharge of Oil
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2003