Records from 2016 to 2022. Most recent: inspection, 7 February 2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2021
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Exhaust gas must not leak from the piping or any connections. Engine exhaust was found leaking from the Port and Starboard engines.
46 CFR 182.430(a) & (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: Satifactory repairs made to engine exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2021
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Fixed bilge system was not working properly.
46 CFR 182.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: Witnessed satisfactory testing of bilge system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 August 2021
Resolved
Fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fixed CO2 system for Engine Room had not been serviced.
46 CFR 176.810(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O provided servicing report from Delmarva Fire Protection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2021
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jacket. Lifejacket stowage boxes were not marked properly.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O labeled lifejacket boxes
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2021
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel had no alcohol test kits.
46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 16 August 2021
Resolution: O/O purchased new alcohol test kits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2021
No resolution recorded
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 6 inches above the deepest subdivision load line must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Hydraulic Coolers missing Overboard discharge valves. Install No Later Than next drydock.
46 CFR 171.119(b)
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and must be in satisfactory condition. Oil accumulation was found on coils and vents of generator.
46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: Generators were cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 August 2021
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be marked at the entranceway to that deck. Max Passengers not marked on vessel.
46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O marked upper deck pax count.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 August 2021
Resolved
A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 inches in diameter.
46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O purchased new life buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 August 2020
No resolution recorded
Vessel is operating with outdated DAPI program
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 August 2020
Resolved
Expired aspirin in first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2020
Resolved 22 September 2020
Resolution: Aspirin repalced
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 August 2020
Resolved
Wastage found forward of the entrance to the engine rooom. repair proposal required.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 October 2020
Resolution: Witnessed satisfactory repair and NDT testing (soap/ 50psi airlance)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 August 2020
Resolved
Forward end of the vessel near the ramp there is a deck rail with a crack at the base and unable to withstand a point load of 200 pounds.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2020
Resolution: Witnessed satisfactory repairs
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 August 2020
No resolution recorded
Vessel was unable to conduct drills due to insufficient crew availability at the time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 August 2020
Resolved
CO2 System on board has not been serviced since 2018.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 October 2020
Resolution: System serviced by Harris Fire Protection, Baltimore MD
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 17 August 2020
Resolved
Vessel had sever wastage in MSD piping upon inspection. Repair proposal required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2020
Resolution: Repaired on 9.22.2020, verified on 10.1.2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019
Resolved
Life rings missing reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2019
Resolution: New reflective tape was added to the life rings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019
Resolved
Life rings had grab lines that were weathered and falling apart.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2019
Resolution: Added new life rings.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 August 2019
Resolved
Need new first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 23 August 2019
Resolution: Vessel recieved new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 August 2019
Resolved
MIssing nav pubs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2019
Resolution: Vessel had added pubs onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 August 2019
Resolved
Vessel had no current charts onboard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2019
Resolution: Vessel has current charts onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2019
Resolved
Vessel's STBD generator was inop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 23 August 2019
Resolution: Tech came out and repaired the gen.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2019
Resolved
FCC Safety Cert was expired.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 31 August 2019
Resolution: Radio service tech came out and gave them a new certificate.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 August 2019
Resolved
No drills have been logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2019
Resolved 23 August 2019
Resolution: Inspectors conducted drills with crew and the crew logged it.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019
Resolved
Waterlight for life ring had an expired battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 23 August 2019
Resolution: Waterlight battery was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 August 2019
Resolved
Fire pump wasn't working properly. not primed and did not work consistantly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2019
Resolution: Fire system tech came out and worked through the system. Found no issues. System was not primed at the begining of the charter season.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019
Resolved
Fuel filters for Port and STBD eng still have pet cocks on them.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2019
Resolved 24 September 2019
Resolution: Verified that the petcocks in the flame shield for the MDE fuel filters were removed and replaced with bolts and nuts. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019
Resolved
2 Hydraulic hoses on each engine had leaks.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 24 August 2019
Resolution: Verified no leaks from (02) hydraulic hoses which are located on each engine, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2019
Resolved
Improper splicing of wires into port battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 24 September 2019
Resolution: Verified that the wiring for the Port side battery was properly spliced, ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2018
Resolved
Navigation Stern Light inoperable due to burnt out bulb.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2018
Resolved 4 October 2018
Resolution: Received proof via email that the above deficiency eas corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2018
Resolved
Pressure Test of Air Receiver overdue.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 27 September 2018
Resolution: Received proof via email that the above deficiency eas corrected.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 May 2017
Resolved
Provide current Certificate of Documentation on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 4 June 2017
Resolution: Received email of new Certificate of Documentaion.
Documentation › Certificates/Documents › FCC SSL
Issued 15 May 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifebuoys › Quantity
Issued 15 May 2017
Resolved
Provide 3 total Life Ring buoys, 1 with a light and approved light holder.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Fire Fighting › Fire Hydrants › Material
Issued 15 May 2017
Resolved
Forward fire station onnetor and hose not standard. Replace with approved sedt-up.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Bilge Water Management System › Pump
Issued 15 May 2017
Resolved
Electric bilge pump leaking. Repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 15 May 2017
Resolved
Rudder angle indicator not operating/repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 May 2017
Resolved
Demonstrate satisfactory MOB drill with CPR proceedures.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Steering Gear System › Linkage
Issued 15 May 2017
Resolved
Free up rudder connector rod.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Cylinder (jet)
Issued 31 January 2017
Resolved
Repair deteriorated hydraulic lines located on the exterior portside Aft stern in way of the paddle wheel. At least 2 of the lines are leaking hydraulic fluid.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2017
Resolved
Provide ultrasonic test report in way of the following areas:
* Starboard Amidships to Starboard Bow (Side Shell)
* Starboard Aft Quarter/Stern
* Port Amidships to Port Bow (Side Shell)
* Port Aft Quarter/Stern
* Weld seam from port to starboard along bottom plating near forward "chine change"
* Ultrasonic testing grid shall be no more than 18 inches apart
Vessel operato
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2017
Resolved 1 February 2017
Resolution: Vessel operator provided results from Ultrasonic Testing of aforementioned areas- ALL SAT.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 30 January 2017
Resolved
Repair exhaust leaks for both the Port and Starboard Main Engine exhaust systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 30 January 2017
Resolved
Renew/Replace missing section of heat-shield protection for the starboard main engine's exhaust system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 30 January 2017
Resolved
Provide ultrasonic Testing results to address the concerns associated with heavy scaling on the sea chest.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2017
Resolved 1 February 2017
Resolution: Vessel operator provided results from Ultrasonic Testing of sea chest – ALL SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 January 2017
Resolved
Remove all "solid-core" wiring located on the main deck lounge's ceiling fan; and replace with approved marine-grade wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Deck/Cargo › Holds/Tanks › Hatch
Issued 30 January 2017
Resolved
Replace the forward Maindeck/Aft access hatch. Existing hatch is excessively deteriorated. (Note: This task will be performed by the new owner/operator)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 5 May 2017
Resolution: Verified the installation of new Maindeck/Aft access hatch; ALL SAT.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 30 January 2017
Resolved
Renew/Repair the deteriorated portion of the starboard-side fuel fill overflow containment system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Engineering › Sea-water System (primary cooling) › Valve
Issued 30 January 2017
Resolved
Remove existing sea chest valve for inspection; and properly install with two unions on either side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 1 February 2017
Resolution: Verified new installation and operation of new sea chest valve with “two union” configuration which will aid in future inspections of the thru-hull.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 July 2016
Resolved
Repair/renew hatch cover for the forward peak compartment. Condition of hatch cover is severely corroded/deteriorate.
Due 28 August 2016
Resolved 20 October 2016
Resolution: Received email picture of hatch installed properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 28 July 2016
Resolved
Replace missing hammer that breaks the glass on CO2 system remote activation device located outside of engine compartment.
Due 11 August 2016
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 July 2016
Resolved
Repair cracked frame where the steering ram stop impacts a frame.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.
Lifesaving › Lifebuoys › Serviceable
Issued 28 July 2016
Resolved
Replace grabline on life ring
Due 5 August 2016
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 July 2016
Resolved
Provide proof of original Certificate of Documentation
Due 11 August 2016
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.