BLACK-EYED SUSAN

BLACK-EYED SUSAN is a 1988 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1988, most recently in February 2022, along with 151 deficiencies — 3 with no resolution recorded —.

Records from 1988 to 2022. Most recent: inspection, 7 February 2022.

Built
1988
Last inspected
7 February 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA2815
298436
Flag
UNITED STATES
367789760, 368213990
Maury page id
psix-298436

Inspections, by type

…with no type recorded7
Years with a record 31 calendar years (1988–2022)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it90 - Convention (Subpart B), Net Ton
55 - Regulatory (Subpart C or D), Net Ton
245 - Convention (Subpart B), Gross Ton
82 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDM5244MMSI 368213990 · active · compulsorily equipped · granted 11 August 2021, expires 11 August 2031
WDJ5635MMSI 367789760 · active · compulsorily equipped · granted 19 May 2017, expires 19 May 2027
WDA2815MMSI 367465720 · expired · compulsorily equipped · granted 4 September 2010, cancelled 2 January 2021 · licensed under a name not among this hull’s recorded names (not shown)
WCY9774MMSI not assigned · expired · compulsorily equipped · granted 8 April 1999, cancelled 13 June 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 59

7 February 2022 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7391828
2 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7275276
1 October 2020 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7069986
17 August 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7035722
19 August 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6787734
25 September 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6548491
15 May 2017 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6147095
5 May 2017 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6183503
30 January 2017 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6082927
28 July 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5959658
26 March 2014 DAPI Audit · COI Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4815274
13 July 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4377569
10 July 2012 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4374337
28 February 2012 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4253506
7 February 2012 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4239784
25 March 2009 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3439906
24 June 2008 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3246469
23 February 2007 Hull Examination · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2876342
28 August 2006 Internal Structural Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2764997
7 July 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2423739
26 April 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2052768
16 April 2004 COI Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2044762
12 April 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2043359
31 March 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2049036
5 January 2004 Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2033898
26 April 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1788999
8 July 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1639560
8 January 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1476586
13 June 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1403401
10 January 2001 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1057718
17 October 2000 Administrative
Administrative · THE UNKNOWN UNIT · Activity 823988
31 July 2000 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1051518
9 April 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1451537
17 February 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1413681
12 November 1999 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 805462
9 November 1999 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 808809
25 March 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1397163
17 February 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1411613
21 January 1998 Deficiency Check · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 784872
21 February 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1380766
10 April 1996 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1079559
12 March 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 885052
7 October 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 53616
27 February 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 872214
22 February 1995 Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 852713
7 March 1994 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1164961
23 April 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 118771
15 March 1993 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 841541
27 February 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 957841
5 February 1992 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 953405
21 January 1992 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1007792
8 March 1991 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1224912
23 February 1990 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 929161
4 May 1989 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1339830
24 February 1989 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1205077
17 June 1988 Damage Survey
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 891892
11 May 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1040507
1 April 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1301028
11 March 1988 Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 984726

Deficiency record · 151

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2021 Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Exhaust gas must not leak from the piping or any connections. Engine exhaust was found leaking from the Port and Starboard engines. 46 CFR 182.430(a) & (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: Satifactory repairs made to engine exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2021 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Fixed bilge system was not working properly. 46 CFR 182.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: Witnessed satisfactory testing of bilge system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 August 2021 Resolved
Fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fixed CO2 system for Engine Room had not been serviced. 46 CFR 176.810(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O provided servicing report from Delmarva Fire Protection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2021 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jacket. Lifejacket stowage boxes were not marked properly. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O labeled lifejacket boxes
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2021 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel had no alcohol test kits. 46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2021
Resolved 16 August 2021
Resolution: O/O purchased new alcohol test kits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 August 2021 No resolution recorded
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 6 inches above the deepest subdivision load line must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Hydraulic Coolers missing Overboard discharge valves. Install No Later Than next drydock. 46 CFR 171.119(b)
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2021 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and must be in satisfactory condition. Oil accumulation was found on coils and vents of generator. 46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 16 August 2021
Resolution: Generators were cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 August 2021 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be marked at the entranceway to that deck. Max Passengers not marked on vessel. 46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O marked upper deck pax count.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 August 2021 Resolved
A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 inches in diameter. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 16 August 2021
Resolution: O/O purchased new life buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 August 2020 No resolution recorded
Vessel is operating with outdated DAPI program
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 August 2020 Resolved
Expired aspirin in first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2020
Resolved 22 September 2020
Resolution: Aspirin repalced
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 August 2020 Resolved
Wastage found forward of the entrance to the engine rooom. repair proposal required.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 October 2020
Resolution: Witnessed satisfactory repair and NDT testing (soap/ 50psi airlance)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 August 2020 Resolved
Forward end of the vessel near the ramp there is a deck rail with a crack at the base and unable to withstand a point load of 200 pounds.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2020
Resolution: Witnessed satisfactory repairs
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 August 2020 No resolution recorded
Vessel was unable to conduct drills due to insufficient crew availability at the time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 August 2020 Resolved
CO2 System on board has not been serviced since 2018.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 October 2020
Resolution: System serviced by Harris Fire Protection, Baltimore MD
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 17 August 2020 Resolved
Vessel had sever wastage in MSD piping upon inspection. Repair proposal required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2020
Resolution: Repaired on 9.22.2020, verified on 10.1.2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019 Resolved
Life rings missing reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2019
Resolution: New reflective tape was added to the life rings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019 Resolved
Life rings had grab lines that were weathered and falling apart.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2019
Resolution: Added new life rings.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 August 2019 Resolved
Need new first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 23 August 2019
Resolution: Vessel recieved new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 August 2019 Resolved
MIssing nav pubs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2019
Resolution: Vessel had added pubs onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 August 2019 Resolved
Vessel had no current charts onboard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2019
Resolution: Vessel has current charts onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2019 Resolved
Vessel's STBD generator was inop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 23 August 2019
Resolution: Tech came out and repaired the gen.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2019 Resolved
FCC Safety Cert was expired.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 31 August 2019
Resolution: Radio service tech came out and gave them a new certificate.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 August 2019 Resolved
No drills have been logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2019
Resolved 23 August 2019
Resolution: Inspectors conducted drills with crew and the crew logged it.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2019 Resolved
Waterlight for life ring had an expired battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 23 August 2019
Resolution: Waterlight battery was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 August 2019 Resolved
Fire pump wasn't working properly. not primed and did not work consistantly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2019
Resolution: Fire system tech came out and worked through the system. Found no issues. System was not primed at the begining of the charter season.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019 Resolved
Fuel filters for Port and STBD eng still have pet cocks on them.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2019
Resolved 24 September 2019
Resolution: Verified that the petcocks in the flame shield for the MDE fuel filters were removed and replaced with bolts and nuts. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2019 Resolved
2 Hydraulic hoses on each engine had leaks.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 24 August 2019
Resolution: Verified no leaks from (02) hydraulic hoses which are located on each engine, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2019 Resolved
Improper splicing of wires into port battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2019
Resolved 24 September 2019
Resolution: Verified that the wiring for the Port side battery was properly spliced, ALL SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2018 Resolved
Navigation Stern Light inoperable due to burnt out bulb.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2018
Resolved 4 October 2018
Resolution: Received proof via email that the above deficiency eas corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2018 Resolved
Pressure Test of Air Receiver overdue.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 27 September 2018
Resolution: Received proof via email that the above deficiency eas corrected.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 May 2017 Resolved
Provide current Certificate of Documentation on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 4 June 2017
Resolution: Received email of new Certificate of Documentaion.
Documentation › Certificates/Documents › FCC SSL
Issued 15 May 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifebuoys › Quantity
Issued 15 May 2017 Resolved
Provide 3 total Life Ring buoys, 1 with a light and approved light holder.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Fire Fighting › Fire Hydrants › Material
Issued 15 May 2017 Resolved
Forward fire station onnetor and hose not standard. Replace with approved sedt-up.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Bilge Water Management System › Pump
Issued 15 May 2017 Resolved
Electric bilge pump leaking. Repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 15 May 2017 Resolved
Rudder angle indicator not operating/repair.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 May 2017 Resolved
Demonstrate satisfactory MOB drill with CPR proceedures.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Steering Gear System › Linkage
Issued 15 May 2017 Resolved
Free up rudder connector rod.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Cylinder (jet)
Issued 31 January 2017 Resolved
Repair deteriorated hydraulic lines located on the exterior portside Aft stern in way of the paddle wheel. At least 2 of the lines are leaking hydraulic fluid.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2017 Resolved
Provide ultrasonic test report in way of the following areas: * Starboard Amidships to Starboard Bow (Side Shell) * Starboard Aft Quarter/Stern * Port Amidships to Port Bow (Side Shell) * Port Aft Quarter/Stern * Weld seam from port to starboard along bottom plating near forward "chine change" * Ultrasonic testing grid shall be no more than 18 inches apart Vessel operato
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2017
Resolved 1 February 2017
Resolution: Vessel operator provided results from Ultrasonic Testing of aforementioned areas- ALL SAT.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 30 January 2017 Resolved
Repair exhaust leaks for both the Port and Starboard Main Engine exhaust systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 30 January 2017 Resolved
Renew/Replace missing section of heat-shield protection for the starboard main engine's exhaust system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 30 January 2017 Resolved
Provide ultrasonic Testing results to address the concerns associated with heavy scaling on the sea chest.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2017
Resolved 1 February 2017
Resolution: Vessel operator provided results from Ultrasonic Testing of sea chest – ALL SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 January 2017 Resolved
Remove all "solid-core" wiring located on the main deck lounge's ceiling fan; and replace with approved marine-grade wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Deck/Cargo › Holds/Tanks › Hatch
Issued 30 January 2017 Resolved
Replace the forward Maindeck/Aft access hatch. Existing hatch is excessively deteriorated. (Note: This task will be performed by the new owner/operator)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 5 May 2017
Resolution: Verified the installation of new Maindeck/Aft access hatch; ALL SAT.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 30 January 2017 Resolved
Renew/Repair the deteriorated portion of the starboard-side fuel fill overflow containment system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2017
Resolved 9 March 2017
Resolution: Attended and cleared above deficiency.
Engineering › Sea-water System (primary cooling) › Valve
Issued 30 January 2017 Resolved
Remove existing sea chest valve for inspection; and properly install with two unions on either side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2017
Resolved 1 February 2017
Resolution: Verified new installation and operation of new sea chest valve with “two union” configuration which will aid in future inspections of the thru-hull.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 July 2016 Resolved
Repair/renew hatch cover for the forward peak compartment. Condition of hatch cover is severely corroded/deteriorate.
Due 28 August 2016
Resolved 20 October 2016
Resolution: Received email picture of hatch installed properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 28 July 2016 Resolved
Replace missing hammer that breaks the glass on CO2 system remote activation device located outside of engine compartment.
Due 11 August 2016
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 July 2016 Resolved
Repair cracked frame where the steering ram stop impacts a frame.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.
Lifesaving › Lifebuoys › Serviceable
Issued 28 July 2016 Resolved
Replace grabline on life ring
Due 5 August 2016
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 July 2016 Resolved
Provide proof of original Certificate of Documentation
Due 11 August 2016
Resolved 17 August 2016
Resolution: Received via email picture of above item correction.
Engineering › Steering Gear System › Ram
Issued 26 March 2014 Resolved
Starboard side rudder hydraulic leak.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2014
Resolution: Hydraulic ram and rudder angle indicator replaced by [name withheld] parts onboard as well. Parts received from Baltimore Hydraulics.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 July 2012 Resolved
Emergency instruction not on board. Post them IAW 46 CFR 185.510
Due 10 August 2012
Resolved 7 August 2012
Resolution: Emergency instruction are posted in the pilot house.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 July 2012 Resolved
Coast Pilot is expired. Renew Coast Pilot. Also, the light list is not on board. It is required. 46 CFR 184.420.
Condition: Invalid
Due 10 August 2012
Resolved 7 August 2012
Resolution: Purchased new coast pilot, and light list book. Now kept inside pilot house.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 July 2012 Resolved
Replace electrical outlet on 02 deck starboard side (overhead). Outlet appeared to be burned/melted
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2012
Resolution: Installed new electrical outlet.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 July 2012 Resolved
Show prove of annual service of fixed fire system. Expired on June 2012.
Condition: Improper/Lack of Maintenance
Due 10 August 2012
Resolved 7 August 2012
Resolution: Showed proof of inspection.
Electrical › Electric Supply System (service) › Cable
Issued 10 July 2012 Resolved
Yellow electrical cable jumping from one electrical box to a second electrical box is require to be a marine grade cable. Replace accordingly. Located at engine room.
Condition: Improper Installation
Due 10 August 2012
Resolved 7 August 2012
Resolution: Removed yellow electrical cable. Installed new marine grade cable.
Electrical › Electric Supply System (service) › Cable
Issued 10 July 2012 Resolved
Electrical extension cord run on port side 02 deck need to be removed. It needs to be a permanent marine grade cable.
Condition: Improper Installation
Due 10 August 2012
Resolved 7 August 2012
Resolution: Extension cord has been removed, and new marine cable has been installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 July 2012 Resolved
Removed wire ties from electrical cable runs. Metal brackets need to be used instead.
Condition: Improper Installation
Due 10 August 2012
Resolved 7 August 2012
Resolution: Removed wire ties, and metal brackets are use instead.
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2012 Resolved
Plugged port aft bulkhead through hole in the lazarette compartment.
Due 10 August 2012
Resolved 7 August 2012
Resolution: Plug hole with sealing compound.
Deck/Cargo › Ballast › SBT
Issued 28 February 2012 Resolved
Remove ballast in vessel to make internal hull available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2012
Resolution: Ballast re-arranged to allow for CG marine inspectors to inspect areas underneath ballast.
Fire Fighting › Fire Main › Condition
Issued 15 April 2009 Resolved
Firemain leaking from elbow fitting leading from fire pump in engine room. Repair/replace prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2009
Resolution: Fitting on firemain repaired to the satisfaction of CG Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 April 2009 Resolved
Anchor light and stern light inoperable. Replace as new prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2009
Resolution: Anchor light and stern light replaced.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 15 April 2009 Resolved
High water alarm inoperable in engine room. Replace as new prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2009
Resolution: High water alarm in engine room replaced with new alarm and functioning properly.
Engineering › Lubricating Oil Service System › Hose
Issued 25 March 2009 Resolved
Hydraulic leak in hose fitting from hydraulic oil storage tank to #2 main engine. Repair/replace as new within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2009
Resolved 27 April 2009
Resolution: Hydraulic hoses replaced as new.
Electrical › Electric Supply System (service) › Cable
Issued 28 August 2006 Resolved
Provide cover for electrical contactor for the air compressor.
Due 28 September 2006
Resolved 18 September 2006
Resolution: cover installed.
Electrical › Electric Generation Source (service) › Generator
Issued 28 August 2006 Resolved
Remove oily residue from generator air intake.
Due 28 September 2006
Resolved 18 September 2006
Resolution: intakes cleaned.
Engineering › Freshwater System (air cooling) › Drainage
Issued 28 August 2006 Resolved
Provide a cap for the freshwater line in the sewage compt.
Due 28 September 2006
Resolved 18 September 2006
Resolution: Cap provided.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 28 August 2006 Resolved
Make repairs to 3" pipe where soft patch is located in the sewage compt.
Due 28 September 2006
Resolved 10 October 2006
Resolution: Repairs completed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 July 2005 Resolved
Service fixed and portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2005
Resolved 20 July 2005
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 7 July 2005 Resolved
Provide proof of consortium enrollment in a drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2005
Resolved 20 July 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 July 2005 Resolved
Provide emergency lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2005
Resolved 20 July 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 July 2005 Resolved
Provide grab lines on Stbd ring buoy.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 20 July 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 July 2005 Resolved
Renew 60ft throw line on Port Ring buoy.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 20 July 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 July 2005 Resolved
Mark number of lifejackets in each storgae box.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 20 July 2005
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 7 July 2005 Resolved
Double clamp all thru-hole hose connections to mde's.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 20 July 2005
Construction/Loadline › Penetrations › Gasket
Issued 7 July 2005 Resolved
FWD two voids hatch cover gaskets wasted and leaking through replace as original.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 20 July 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 July 2005 Resolved
Remove all oily waste in void space aft of forepeake void.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 20 July 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 April 2004 Resolved
Provide Certificate of Documentation
Due 16 May 2004
Resolved 23 December 2004
Resolution: COD provided.
Documentation › Certificates/Documents › FCC SSL
Issued 16 April 2004 Resolved
Provide FCC Radio Safety Certificate
Due 16 May 2004
Resolved 28 July 2004
Resolution: RSC provided.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 16 April 2004 Resolved
Provide FCC Marine Radio Operators Permit
Due 16 May 2004
Resolved 14 May 2004
Resolution: operator''''spermit provided.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 April 2004 Resolved
Permanently secure wires on port aft bridge outlet
Due 16 May 2004
Resolved 28 July 2004
Resolution: secured.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 16 April 2004 Resolved
Provide lagging on main engine exhaust
Due 16 May 2004
Resolved 28 July 2004
Resolution: lagging installed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankshaft
Issued 16 April 2004 Resolved
Remove extra belts from around generator crankshaft
Due 16 May 2004
Resolved 14 May 2004
Resolution: belts removed.
Stability › Watertight Integrity › General
Issued 16 April 2004 Resolved
Seal bulkhead penetration in stbd, fwd CO2 space
Due 16 May 2004
Resolved 14 May 2004
Resolution: bulkhead sealed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 April 2004 Resolved
Provide brackets for beverage CO2 bottles
Due 16 May 2004
Resolved 14 May 2004
Resolution: brackets provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 April 2004 Resolved
Remove excess wire from CO2 pull cable
Due 16 May 2004
Resolved 14 May 2004
Resolution: excess cable removed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 16 April 2004 Resolved
Repair exhaust leak on port engine
Due 16 May 2004
Resolved 14 May 2004
Resolution: exhaust leak repaired.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 April 2004 Resolved
Provide cover for junction box in lazarette
Due 16 May 2004
Resolved 14 May 2004
Resolution: cover provided.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Cylinder (jet)
Issued 16 April 2004 Resolved
Provide proof that all flex hoses comply with SAE J1942.
Due 16 May 2004
Resolved 14 May 2004
Resolution: hoses comply.
Stability › Incline Test › General
Issued 16 April 2004 Resolved
Secure ballast in lazarette.
Due 16 May 2004
Resolved 28 July 2004
Resolution: ballast secured.
Engineering › Steering Gear System › Linkage
Issued 16 April 2004 Resolved
Secure pipe iwo flanking rudder bar.
Due 16 May 2004
Resolved 14 May 2004
Resolution: pipe secured.
Stability › Unintentional Flooding › General
Issued 16 April 2004 Resolved
Remove toggle switch on high water alarm on bridge.
Due 16 May 2004
Resolved 14 May 2004
Resolution: switch removed.
Construction/Loadline › Hull › Weld
Issued 16 April 2004 Resolved
Provide approved plans for modifications from MSC
Due 16 May 2004
Resolved 28 July 2004
Resolution: approved plans from MSC.
Documentation › Certificates/Documents › Stability Letter
Issued 16 April 2004 Resolved
Provide stability letter
Due 16 May 2004
Resolved 28 July 2004
Resolution: Stab letter provided.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 April 2004 Resolved
Prior to carrying pasengers on the upper deck or 16 May 04: secure area iwo stairs or install rails at top of spiral stairs
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2004
Resolved 14 May 2004
Resolution: rails installed
Engineering › Pressure Vessel › Shell Plate
Issued 16 April 2004 Resolved
Prior to using air compressor and before 16 May 04: provide thickness gauge of the bottom of cylinder and percent wastage.
Due 16 May 2004
Resolved 14 May 2004
Resolution: reciever gaged.
Fire Fighting › Fire Main › Condition
Issued 31 March 2004 Resolved
Provide proper gauge prior to carrying passengers. LEGACY COMPONENT DESC: Pressure gauge
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2004
Resolved 7 July 2005
Documentation › Certificates/Documents › Stability Letter
Issued 31 March 2004 Resolved
Provide stability letter prior to carrying passengers. LEGACY COMPONENT DESC: Stability Letter
Action required: 705 - Other - as specified
Due 1 May 2004
Resolved 7 July 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 January 2004 Resolved
Update COD with current vessel length, GT, NT prior to carrying passengers. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 1 May 2004
Resolved 7 July 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 January 2004 Resolved
Provide proof of all plan approvals prior to carrying passengers. LEGACY COMPONENT DESC: Plan review/approvals
Action required: 705 - Other - as specified
Due 1 May 2004
Resolved 7 July 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 April 2003 Resolved
Conduct MOB in presence of a Marine Inspector.
Due 10 May 2003
Resolved 7 July 2005
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 26 April 2003 Resolved
Place non-conductive matting at main electrical switchboard in E/R.
Due 10 May 2003
Resolved 7 July 2005
Electrical › Lighting (emergency)
Issued 8 July 2002 Resolved
REPAIR/RENEW AFT EMERGENCY LIGHTING IN MAIN SALON.
Due 8 August 2002
Resolved 2 August 2002
Electrical › Lighting (service)
Issued 8 July 2002 Resolved
PROVIDE COVER OVER ELECTRICAL OUTLET IN GALLEY. LEGACY COMPONENT DESC: Outlet Box
Due 8 August 2002
Resolved 2 August 2002
Navigation › Piloting/Steering
Issued 8 July 2002 Resolved
PROVIDE CURRENT COPY OF TIDE TABLES. LEGACY COMPONENT DESC: River Current Tables
Due 8 August 2002
Resolved 2 August 2002
Lifesaving › Lifebuoys
Issued 8 July 2002 Resolved
PROVIDE RETRO REFLECTIVE TAPE ON REAR OF BOTH RING BUOYS. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 8 August 2002
Resolved 2 August 2002
Communications › Radio Communications › VHF Radiotelephone
Issued 8 July 2002 Resolved
OBTAIN FCC SAFETY CERTIFICATE. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 8 August 2002
Resolved 27 April 2005
Documentation
Issued 13 June 2001 Resolved
PROVIDE COPY OF PRE-1997 (OLD T) 46 CFR SUBCHAPTER T, PARTS 166-199.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Engineering
Issued 13 June 2001 Resolved
REPAIR R.P.M. GUAGE.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Lifesaving
Issued 13 June 2001 Resolved
PROVIDE VESSEL LOGS FOR: ABANDON SHIP / MAN OVERBOARD - 185.520_x001C_ FIRE DRILL - 185.524_x001C_ LIVESAVING MAINTENANCE - 185.702
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Navigation
Issued 13 June 2001 Resolved
REPAIR RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Documentation
Issued 9 April 2000 Resolved
HAVE VESSEL'S DOCUMENTATION CHANGED TO REFLECT NEW OWNER AND OPERATOR.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Navigation
Issued 9 April 2000 Resolved
PROVIDE CURRENT COPY OF 46 CFR PARTS 166-199.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Engineering
Issued 9 April 2000 Resolved
PROVIDE GUARDS OVER ROTATING MACHINERY IN ENGINE ROOM.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Engineering
Issued 9 April 2000 Resolved
PROVIDE INSULATION ON DRY EXHAUST PIPES FROM MAIN DIESEL ENGINES.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Accommodation/Occupational Safety
Issued 9 April 2000 Resolved
MODIFY VESSEL'S FWD GANGWAY TO REACH WATER'S EDGE FOR USE AS A RESCUE PLATFORM, AND CONDUCT MAN OVERBOARD DRILLS.
Condition: Unknown
Due 9 April 2000
Resolved 12 April 2000
Electrical
Issued 9 April 2000 Resolved
PROVIDE SAFETY CAGES ON 02 DECK LIGHTS, ONE PORTSIDE AND ONE STBD SIDE.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Lifesaving
Issued 9 April 2000 Resolved
PROVIDE GUARD FOR ROTATING MACHINERY (PADDLE WHEELS) FROM FWD DIAGONAL STANCHION, TO AFT HOUSE BULKHEAD TO 6FT ABOVE WATERLINE. TO PROTECT CREWMANWORKING AFT CLEATS.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Navigation
Issued 17 February 2000 Resolved
PROPERLY SUPPORT HYDRAULIC LINES FOR STEERING SYSTEM IWO PADDLE FRAMES.
Condition: Unknown
Due 28 March 2000
Resolved 30 March 2000
Electrical
Issued 17 February 2000 Resolved
REPLACE MISSING GUARDS ON DECK LIGHTS AND REPLACE GASKET ON #3 LIGHT AFT ONSTBD MAIN DECK.
Condition: Unknown
Due 28 March 2000
Resolved 30 March 2000
Accommodation/Occupational Safety
Issued 17 February 2000 Resolved
REPLACE BOTH AFT HEAD VENTS.
Condition: Unknown
Due 28 March 2000
Resolved 30 March 2000
Engineering
Issued 17 February 2000 Resolved
PROVIDE FLAME SCREEN FOR STBD FUEL VENT.
Condition: Unknown
Due 28 March 2000
Resolved 30 March 2000
Navigation
Issued 25 March 1999 Resolved
PROVIDE PROPER MASTHEAD AND STERN LIGHTS IN RESPECTIVE LOCATIONS.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Electrical
Issued 25 March 1999 Resolved
REPLACE WIRING FOR SPOTLIGHT ON FORWARD MAST.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Electrical
Issued 17 February 1998 Resolved
REPLACE WORN WATERTIGHT COVER ON SECOND DECK EXTERIOR OUTLET, STBD SIDE.
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Construction/Loadline
Issued 17 February 1998 Resolved
REPLACE WORN GASKETS ON 2 FORWARD FLUSH DECK ROUND HATCHES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Unknown
Issued 21 January 1998 Resolved
REPLACE RELIEF VALVE FOR SHIP'S SERVICE AIR RECEIVER WITH THE PROPER TYPE WITH A HAND RELIEVING DEVICE.
Condition: Unknown
Due 21 February 1998
Resolved 23 January 1998
Electrical
Issued 12 March 1996 Resolved
PROVIDE NEW SHORE TIE CABLE PRIOR TO LOADING ANY PASSENGERS.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Electrical
Issued 12 March 1996 Resolved
PROVIDE NEW GLASS COVERING FOR LIGHT BULB LOCATED IN E/R PRIOR TO 31MAR96.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Electrical
Issued 12 March 1996 Resolved
PROVIDE JUNCTION BOX FOR INTERCOM WIRES LOCATED FORWARD MAINDECK OUTSIDE PRIOR TO 31MAR96.
Condition: Unknown
Due 12 March 1996
Resolved 12 March 1996
Navigation
Issued 22 February 1995 Resolved
REPLACE WORN PORT HYDRAULIC STEERING HOSE PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Lifesaving
Issued 22 February 1995 Resolved
PROVE PROPER OPERATION OF AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Documentation
Issued 7 March 1994 Resolved
PROVIDE PROOF THAT ALL EMPLOYEES HAVE HAD DRUG AWARENESS TRAINING IN THE PAST 12 MONTHS.
Condition: Unknown
Due 15 March 1994
Resolved 10 March 1994
Navigation
Issued 7 March 1994 Resolved
RENEW WORN PINS IN AFT HYDRAULIC STEERING SYSTEM.
Condition: Unknown
Due 23 March 1994
Resolved 3 May 1994
Fire Fighting
Issued 7 March 1994 Resolved
REPAIR/REPLACE HAND FIRE PUMP AND PROVE PROPER OPERATION.
Condition: Unknown
Due 15 March 1994
Resolved 10 March 1994
Construction/Loadline
Issued 21 January 1992 Resolved
PROPERLY REPAIR PORT STERN CLEAT.
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Construction/Loadline
Issued 21 January 1992 Resolved
CLAD WELD ARC BLOW IN HULL PLATINE IN FORE PEAK TANK.
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Construction/Loadline
Issued 21 January 1992 Resolved
CROP AND RENEW, AS ORIGINAL, DECK UNDER STARBOARD STERN LADDER.
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Engineering
Issued 8 March 1991 Resolved
PROVIDE DOCUMENTATION OF SHOP TEST OF RELIEF VALVE ON AIR RECIEVER. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 8 March 1991 Resolved
MAKE TEMPORARY REPAIRS TO THE FRACTURE ON THE DIESEL FUEL TANK. PERMANENT REPAIRS TO BE COMPLETED NO LATER THAN 15JAN92._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 March 1991
Resolved 8 March 1991
Engineering
Issued 11 May 1988 Resolved
RELOCATE EMERGENGY SHUTOFFS FOR FUEL TO FUEL TANK END OF FUEL LINE.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Construction/Loadline
Issued 11 May 1988 Resolved
REMEASURE VESSEL TO DETERMINE LENGTH FOR INSPECTION PURPOSES.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Electrical
Issued 11 May 1988 Resolved
REPLACE 4 QUARTZ TYPE SPOTLIGHTS WITH UL APPROVED FOR MARINE USE FIXTURES.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Fire Fighting
Issued 11 March 1988 Resolved
MARK LOCATION OF FIRE AXE ON OUTER DOOR OF A/C ROOM PRIOR TO CARRYING PASSENGERS AND/OR ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Accommodation/Occupational Safety
Issued 11 March 1988 Resolved
MARK/STENCIL POTABLE WATER AND SEWAGE TANKS PRIOR TO CARRYING PASSENGERS AND/OR ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Lifesaving
Issued 11 March 1988 Resolved
PROVIDE SIX (6) HAND ORANGE SMOKE DISTRESS SIGNALS AND PROPER STOWAGE CONTAINERS PRIOR TO CARRYING PASSENGERS AND/OR ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Engineering
Issued 11 March 1988 Resolved
RELOCATE EMERGENCY FUEL SHUTDOWN AFT OF MAIN FUEL FILTER BANKS PORT AND STARBOARD ENGINE AND TEST PRIOR TO CARRYING PASSENGERS AND/OR ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Lifesaving
Issued 11 March 1988 Resolved
PROVIDE 10 ADDITIONAL ADULT AND 1 CHILD SIZE LIFE JACKETS PRIOR TO CARRYING PASSENGERS AND/OR ASSIGNED COMPLIANCE DATE.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988

Ownership record