Records from 1988 to 2025. Most recent: inspection, 30 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
30 July 2025
Type not recorded
No type recorded · Station Castle Hill · USCG Northeast District (CGD-NE) · Activity 8199967
17 August 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1416944
5 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784368
17 July 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1448943
20 March 1997
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1102679
3 May 1995
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203751
3 April 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842568
10 March 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861939
4 May 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332668
26 May 1993
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827425
9 November 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957499
15 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265849
13 July 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955323
25 June 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958100
9 June 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949978
6 October 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259907
7 May 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212397
2 July 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228932
13 March 1990
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 912953
21 February 1990
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1216629
15 May 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206066
30 November 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1350418
13 June 1988
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200791
15 April 1988
Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1301499
14 April 1988
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034834
17 March 1988
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1277041
Lifesaving › Lifebuoys › Not on Board
Issued 17 August 1999
Resolved
Provide life ring buoy IAW 46CFR180.70
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was not cleared.
Construction/Loadline › Hull › Hull Plating
Issued 17 August 1999
Resolved
Make subdivision bulkheads watertight._x001C_ _x001C_ Example: engine room/galley bulkhead below decking; provide suffing tubes for electrical runs and proper piping penetrations.
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI Expired and def was never cleared.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 August 1999
Resolved
Provide copy of 46CFR Subchapter "T"
Condition: Unknown
Due 17 September 1999
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Construction/Loadline › Structures › Scuttle
Issued 17 August 1999
Resolved
Prove proper operation of all emergency exits and hatches.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 17 August 1999
Resolved
Hydrostatically test air compresser tank in the presence of the attending USCG Marine Inspector IAW 46CFR176.812 which refers to 46CFR61.10
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 August 1999
Resolved
Prove proper operation of bilge system and bilge high level alarms IAW 46CFR182.500 _x001C_ _x001C_ Make repairs to reach rod for closure of collision bulkhead bilge valve.
Condition: Unknown
Due 17 August 1999
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 17 August 1999
Resolved
Provide rentention against movement for refrigerator and stove, locking devices for refrigerator and stove doors, and sea rails for stove IAW 46CFR184.220
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Construction/Loadline › Hull › Hull Plating
Issued 17 August 1999
Resolved
Dry dock vessel and make available for inspection IAW (In Accordance With) 46CFR176.600
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 17 August 1999
Resolved
Ensure all flooring, carpets, furnishings and replacement of such are IAW 46CFR177.410 which refers to 46CFR116.423
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 17 August 1999
Resolved
Prove proper operation of controls and guages at both navigation stations
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 17 August 1999
Resolved
Stencil vessel name on each life jacket and ensure that they weet the requirements of 46CFR180.71
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Lifesaving › Hand Flares › Not on Board
Issued 17 August 1999
Resolved
Provide visual distress flares IAW 46CFR180.68
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Construction/Loadline › Structures › Door
Issued 17 August 1999
Resolved
Renew port and starboard Pilot House windows.
Condition: Unknown
Due 1 January 2000
Resolved 17 August 1999
Resolution: COI expired and def was never cleared.
Engineering
Issued 20 March 1997
Resolved
COMPLETE INSTALLATION OF THE FWD SEA SUCTION MANIFOLD PIPING SYSTEM.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 20 March 1997
Resolved
PROVE PROPER OPERATION OF THE FIRE DETECTION SYSTEM.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 20 March 1997
Resolved
PROVIDE INFORMATION REGUARDING THE ORANGE ELECTRICAL WIRE CABLE THAT IS_x001C_ USED TO HARD WIRE MANY APPLIANCES.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 March 1997
Resolved
SERVICE THE FOREPEAK VALVE/STRAINER.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 March 1997
Resolved
CLEAN ALL BILGE STRAINERS IN THE ENGINEROOM.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 March 1997
Resolved
CAP/PLUG ALL UNUSED PIPE PENETRATIONS LOCATED ON THE AFT ENGINEROOM BULKHEAD.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 March 1997
Resolved
PROVIDE WEIGHT INFORMATION OF THE CEMENT AND IRON BALLAST IN AFT AREA.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 March 1997
Resolved
PROPERLY MOUNT BILGE STRAINERS WITH METALLIC BRACKETS.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 20 March 1997
Resolved
RE-INSTALL THE FLORESENT LIGHT COVER STBD SIDE ENGINEROOM.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 20 March 1997
Resolved
COMPLETE AN INSPECTION FOR CERTIFICATION PRIOR TO THE CARRAGE OF PASSENGERS
Condition: Unknown
Due 4 May 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 March 1997
Resolved
PROVIDE COPIES OF AUDIOGAUGING REPORTS AND STABILITY LETTER.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 20 March 1997
Resolved
PROVIDE A DETAILED WIRING DIAGRAM FOR ALL NEW ELECTRICAL INSTALLATIONS AND MODIFICATIONS.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 20 March 1997
Resolved
REPLACE PORT AND STARBOARD FUEL TANK SIGHT GLASSES.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 20 March 1997
Resolved
PROVE PROPER OPERATION OF THE REMOTE FUEL VALVE, STBD SIDE.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 20 March 1997
Resolved
LABEL ALL BILGE VALVES.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 20 March 1997
Resolved
INSTALL DRIP-PROOF COVERS OVER BATTERY CHARGERS.
Condition: Unknown
Due 20 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 10 March 1995
Resolved
PROVIDE CURRENT COPIES OF LIFERAFT SERVICING REPORTS. VESSEL RESTRICTED TO WITHIN ONE MILE OF LAND UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Engineering
Issued 4 May 1994
Resolved
REPLACE BROKEN SIGHT GLASS FOR THE STARBOARD FUEL TANK, NLT 20MAY94.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Engineering
Issued 4 May 1994
Resolved
MAKE TEMPORARY REPAIR TO LEAK ON PORT FUEL OIL TANK, ISOLATE THE TANK AND THE SAME IS NOT TO BE USED UNTIL PERMANENT REPAIR IS COMPLETED TO THE SATISFACTION OF ATTENDING USCG INSPECTORS.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Engineering
Issued 4 May 1994
Resolved
MAKE PERMANENT REPAIR TO WELD ON THE TRANSFER PIPE FOR THE PORT FUEL OIL TANK IN WAY OF TANK PENETRATION, NLT 31DEC94.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Accommodation/Occupational Safety
Issued 25 June 1992
Resolved
REPAIR/REPLACE GASKET ON GALLEY ESCAPE SCUTTLE LOCATED FORWARD OF_x001C_ THE PILOT HOUSE. INSURE THAT IT WILL PASS WATERTIGHT TEST.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Lifesaving
Issued 25 June 1992
Resolved
OBTAIN PRIMARY LIFESAVING EQUIPMENT (I.E. LIFERAFT, LIFEFLOAT) FOR 10 MORE PERSONS TO MAINTAIN PRESENT COASTWISE ROUTE.
Condition: Unknown
Due 10 July 1992
Resolved 16 July 1992
Electrical
Issued 25 June 1992
Resolved
SECURE BATTERIES IN BATTERY BOX IN VOID BELOW GALLEY DECK.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Accommodation/Occupational Safety
Issued 25 June 1992
Resolved
SCUTTLE AFT OF PILOT HOUSE IN MAIN CABIN USED AS EMERGENCY EXIT FROM ENGINEROOM: CUT CARPET AROUND SCUTTLE TO ALLOW FOR EASY OPENING OF SAME FROM ENGINE SPACE.
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Navigation
Issued 25 June 1992
Resolved
OBTAIN DEVIATION TABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Fire Fighting
Issued 25 June 1992
Resolved
HAVE TWO (2) CO2 FIRE EXTINGUISHERS (BII'S) WHICH ARE KEPT IN THE ENGINEROOM HYDROSTATIC TESTED.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Documentation
Issued 25 June 1992
Resolved
OPTAIN FCC LICENSE AND RADIOTELEPHONY CERTIFICATE. ALSO, PROVIDE RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Electrical
Issued 25 June 1992
Resolved
PLACE RUBBER MAT UNDER GENERATOR PANEL IN ENGINEROOM.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Electrical
Issued 6 October 1991
Resolved
REMOVE EXTENSION CORD WIRING FROM VESSEL (SEE BILGE ACCESS AREA IN COMPT FWD OF ENGINE ROOM).
Condition: Unknown
Due 10 October 1991
Resolved 7 February 1992
Construction/Loadline
Issued 6 October 1991
Resolved
FREE REACH ROD FOR FOREPEAL BILGE SUCTION CONTROL VALVE.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Navigation
Issued 6 October 1991
Resolved
PAINT SIDE LIGHT SCREENS BLACK 3 FEET FWD OF LIGHT. MOVE SIDE LIGHTS OR NAME BOARD SO THAT SIDE LIGHTS ARE VISIBLE THROUGH FULL REQUIRED ARC.
Condition: Unknown
Due 6 October 1991
Resolved 6 October 1991
Construction/Loadline
Issued 6 October 1991
Resolved
SECURE WATER TIGHT ACCESS COVER PLATE ON DECK FWD OF WTD TO ENGINE ROOM PRIOR TO CARRYING PESSENGER ON VESSEL.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 6 October 1991
Resolved
REPACK BOTH SHAFTS GLARDS.
Condition: Unknown
Due 10 December 1991
Resolved 6 February 1992
Electrical
Issued 6 October 1991
Resolved
GROUND INNERTOR FOR STEREO SYSTEM POWER SUPPLY NEAR STBD RUDDER POST. RENEWDAMAGE WIRE SUPPLYING POWER AND SECURE, SO ALL WIRING IS CLEAR OF STEERING GEAR.
Condition: Unknown
Due 30 October 1991
Resolved 6 February 1992
Engineering
Issued 6 October 1991
Resolved
RENEW INTERNAL INTERMEDIATE BEARINGS (AFT) ON BOTH SHAFTS PRIOR TO PLACING VESSEL SERVICE.
Condition: Unknown
Due 6 February 1992
Resolved 6 February 1992
Engineering
Issued 6 October 1991
Resolved
REMOVE OPEN ENDED SPRING RETAINER STYLE PET COCKS FROM FUEL FILTER AND REPLACE WITH PLUGS
Condition: Unknown
Due 30 October 1991
Resolved 7 February 1992
Construction/Loadline
Issued 6 October 1991
Resolved
CLEAN OIL AND TRASH FROM BILGES.
Condition: Unknown
Due 6 October 1991
Resolved 6 October 1991
Construction/Loadline
Issued 6 October 1991
Resolved
INSTALL A REACH ROD ON THE MDE SEA SUCTION VALVE.
Condition: Unknown
Due 6 October 1991
Resolved 6 October 1991
Engineering
Issued 6 October 1991
Resolved
RENEW WASTED SECTIONS OF EXHAUST PIPES NEAR ENGINE MANIFOLDS PRIOR TO SAILING.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Electrical
Issued 6 October 1991
Resolved
RESECURE FUSE CASE ON PORT 240/110 VAC GENERATOR.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Electrical
Issued 6 October 1991
Resolved
RESURE SOLENOID NEAR INBOARD AFT MOTOR MOUNT OF PORT MDE PRIOR TO SAILING.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 15 April 1988
Resolved
CONDUCT SEA-TRIAL WITNESSED BY CG MARINE INSPECTOR. PROVE PROPER OPERATION OF MAIN PROPULSION, SERVICE GENERATORS, FIRE AND BILGE SYSTEM, STEERING SYSTEM, PILOT HOUSE CONTROL, FIRE DETECTION SYSTEM, AND ALL ALARMS INSTALLED ON BOARD.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Documentation
Issued 15 April 1988
Resolved
PROVIDE STABILITY LETTER ISSUED BY MSC BASED ON STABILITY TEST AND CALCULATIONS MADE AND SUBMITTED, PRIOR TO ISSUE OF COI.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988
Resolved
PROVIDE PROPER STOWAGE OF TWO LIFERAFTS ON BOARD AND PROPERLY MOUNTED OR SECURED TO THE VESSEL.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Navigation
Issued 15 April 1988
Resolved
PROVE THE PROPER OPERATION OF ALL ELECTRONIC NAVIGATING EQUIPMENT FITTED INTHE PILOT HOUSE.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Engineering
Issued 15 April 1988
Resolved
PRESENT P&S MDE EXHAUST SYTEM INSTALLATIONS ARE NOT ACCEPTABLE. PROVIDE PLANS AND MEANS OF RE-ROUTING THE INSTALLED SYSTEM FOR APPROVAL TO THE SATISFACTION OF COGNIZANT OCMI, NOT LATER THAN 15MAY88.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988