MAURY USCG vessel records Sign in
← All vessels

WILLIAM A SODERMAN

WILLIAM A SODERMAN is a 2002 public vessel, unclassified. The Coast Guard has recorded 82 inspections since 2002, most recently in April 2026, along with 29 deficiencies and 2 operational controls.

Records from 2002 to 2026. Most recent: inspection, 29 April 2026.

Built
2002
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9232254 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-29867

Inspections, by type

…with no type recorded17
Years with a record 23 calendar years (2002–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)911.7 ft × 105.8 ft × 89.1 ft
Registered tonnagegross 72,977 / net 21,893
ITC dimensions (L × B × D)911.7 ft × 105.8 ft × 89.1 ft
ITC tonnagegross 72,977 / net 21,893
BuilderGENERAL DYNAMICS, NATIONAL STEEL AND SHIPBUILDING COMPANY · SAN DIEGO, CA, UNITED STATES · built 2002
Hull materialSteel
PropulsionGas Turbine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72977 - Convention (Subpart B), Gross Ton
21893 - Convention (Subpart B), Net Ton
35950 - Dead Weight, Ton
69968 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 82

29 April 2026 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8358013
20 March 2026 MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8329116
20 November 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8319188
10 November 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8266801
8 September 2025 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8229312
23 August 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8216161
19 May 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8136911
7 March 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8090923
3 December 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042838
25 November 2024 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8040098
30 September 2024 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8011480
6 June 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7929446
16 May 2024 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7914016
1 May 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7904834
24 March 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8084649
13 April 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7668358
12 April 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7679224
3 April 2023 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7645921
30 September 2021 Annual Inspection · ACP COI Oversight · ACP Drydock Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7323881
16 December 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7112993
27 October 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7114545
21 October 2020 Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7092695
31 August 2020 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7047166
1 May 2020 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6946615
10 March 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6923622
13 November 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6854448
23 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6668183
10 December 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6595369
12 January 2018 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6338608
6 November 2017 Annual Inspection · Drydock Exam · ACP COI Oversight · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6301407
5 August 2017 Re-Inspection · ACP COI Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6223008
22 December 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5847124
15 August 2016 ACP Annual Oversight
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5961116
25 April 2016 In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5863467
25 April 2016 In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5879190
16 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5855748
21 January 2016 Underwater Inspection in lieu of Drydock
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5800837
30 October 2015 ACP Annual Oversight
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 5733161
27 August 2015 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5227296
5 August 2014 ACP Periodic Oversight
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4945465
19 May 2014 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4861710
7 May 2012 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4303946
9 January 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4335782
20 September 2011 ACP Annual Oversight · Damage Survey · Examination of Repairs
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4149469
15 September 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3839735
10 July 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3533142
13 March 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3432774
20 February 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3425110
11 February 2009 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3416652
23 January 2009 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3416569
13 November 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3362175
14 October 2008 Administrative Inspection
Administrative · Activities Europe · Activity 3344145
7 February 2008 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3143356
4 February 2008 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3141555
18 December 2007 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3099648
13 September 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3056700
5 September 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3051019
11 October 2006 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2798037
4 October 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2793373
13 September 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2777228
15 May 2006 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 2649328
26 April 2006 Deficiency Check · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2637376
12 April 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2622920
25 March 2006 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 2623593
13 September 2005 Underwater Inspection in lieu of Drydock · Internal Structural Exam · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · ACP Periodic Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2498370
7 March 2005 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2304622
18 February 2005 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2294956
3 February 2005 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2285699
12 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2219387
8 September 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2183829
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104866
3 March 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2014294
13 February 2004 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2008427
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976312
14 November 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1948005
27 October 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1928152
20 August 2003 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1881659
13 May 2003 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1792596
8 May 2003 In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1805229
26 March 2003 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1763334
12 November 2002 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1704163
18 September 2002 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1677512

Deficiency record · 29

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The company representative reported the emergency diesel generator is not working properly. 74 SOLAS (2020 Con. Ed.) I/11(a); 60a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2025
Resolution: Received report and finding numbers from ABS accepting deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 August 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. VSL reported failure of their #1 steering system and STBD rudder. Rectify prior to movement 74SOLAS (2020) 1/11 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 August 2025
Resolution: Accepted by RO
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 May 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The painter for life raft #3 on starboard side main deck is not permanently attached to the ship. 74 SOLAS (20 Con)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 May 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection. Heat detectors at approximate frame numbers 75, 91, 94, 98, 99, and 103 on 4B deck did not operate within manufactures specifications and were rendered inoperable/taken out of service by the fire servicing company with no estimated time of repair. To be rectified prior to cargo operations but no later than 30 days. 74 SOLAS (20 Con) II-2/14.2.1.1.2
Action required: 705 - Other - as specified
Due 16 June 2025
Resolved 20 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 May 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, and protection of openings and penetrations in these divisions. Found wooden cover access plate installed on ventilation ducting on 1B deck. 74 SOLAS (20 Con) II-2/ 14.2.1.1.1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 May 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. MI observed multiple holes approx. 1/4" diameter drilled through B-class bulkhead of the 02 deck unlicensed crew lounge. 74 SOLAS (20 Con) II-2/ 14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2025
Resolved 20 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2025 Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. CGMI identified multiple electrical hazards in the Engine Control Room in the form of extension cords plugged into surge protectors. 74SOLAS(01CONS) II-1 / 40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2025
Resolved 20 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 16 May 2024 Resolved
The angular position of the rudder shall: be indicated on the navigation bridge; be recognizable in the steering gear compartment. The rudder angle indicator in both the steering gear compartment and the navigation bridge varied at different ranges from the indicator on the steering gear. 74 SOLAS (04 Cons) II-1/29.11 1 and 2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2024
Resolved 29 May 2024
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2024 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Fire doors in the galley were held open with hold-back hooks that were not capable of being remotely released. 74 SOLAS (01 Cons) II-2/47.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2024
Resolved 29 May 2024
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 May 2024 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Laundry vent on port side located next to lifeboat davit controls, was wasted and unable to be closed. 74 SOLAS (01 Cons) II-2/16.9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2024
Resolved 29 May 2024
Resolution: Accepted by RO.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 18 December 2020 Resolved
Oil filtering equipment shall be provided with alarm arrangements to indicate when oil content exceed 15 PPM. Oil content monitor on engine room OWS failed to activate alarm. Conduct repairs IAW equipment's manufacture procedures and provide CG a copy of ABS Class Survey for Compliance Report.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2021
Resolved 14 January 2021
Resolution: MSD Saipan approved compliance report from vessel.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 January 2018 Resolved
Vessel is approved for Periodically Unattended Engine Room. Vessel has 5 generators #1 Generator is down for routine repairs and was not able to go through any of the required Periodic Safety Test Procedures (PSTP). Until the PSTPs for the #1 generator are demonstrated in the presence of American Bureau of Shipping, the Periodically Unattended Engen Room endorsement is removed.
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 12 January 2018
Resolution: Received ABS Class report attesting to the successful test of automation to the #1 SSDG.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 26 April 2016 Resolved
Demonstrate proper operation of the vessel emergency diesel generator.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 17 May 2016
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 25 April 2016 Resolved
Failure of engine drive end coupler.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 12 May 2016
Resolution: Class report & tests carried out.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 22 September 2011 Resolved
During testing of emergency diesel generator (EDG) after installation of the new coupling it failed on the fifth start. This is the second failure of the EDG coupling in the past week. Because of this the EDG is inoperable now and the coupling needs to be replaced. Vessel cannot depart the Port of Guam until satisfactory repairs are made to the EDG to the satisfaction of ABS or USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2011
Resolution: Coupling was replaced and tested satisfactory.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 13 March 2009 Resolved
Vessel has SOC from EPA for SSG's but still needs EIAPP from EPA as required by MARPOL Annex VI, Reg 13 and CG policy letter 09-01 part 5.b.i. Vessel is being issued IAPP but has 90 days to meet and show proof of EPA issued EIAPP for each SSG.
Action required: 705 - Other - as specified
Due 1 September 2009
Resolved 22 September 2009
Resolution: Vessel obtained EPA EIAPP certificate
Operations/Management › Drills/Instruction › Fire
Issued 19 February 2009 Resolved
Complete fire/boat drills, prove safe manning and update all charts and pubs as needed upon activation prior to departing port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2009
Resolution: Completed fire/boat drills, proved safe manning and made updated charts and nav pubs available for inspection.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 19 February 2009 Resolved
Provide proof of required provisions for all lifeboats prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2009
Resolution: Replaced and provided proof of required provisions for all lifeboats.
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 19 February 2009 Resolved
Provide proof of compliance with MARPOL Annex VI / IAPP within two weeks from inspection.
Due 5 March 2009
Resolved 13 March 2009
Resolution: Completed and issued IAPP as required.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 19 February 2009 Resolved
Provide proof of annual surveys on ABS certs as needed within two weeks from inspection.
Due 5 March 2009
Resolved 13 March 2009
Resolution: Provided proof of completion of annual ABS surveys as required.
Construction/Loadline › Structures › Superstructure
Issued 19 February 2009 Resolved
Replace safety hand rails throughout ship as needed within 30 days from inspection.
Due 19 March 2009
Resolved 13 March 2009
Resolution: Safety hand rails throughout ship repair/replaced as needed.
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 14 October 2008 Resolved
24 inch crack at hull-deck interface; delamination of hull structure in way of crack.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 December 2008
Resolved 23 January 2009
Resolution: Replaced rescue boat from USNS Watkins
Communications › Alarms/Indicators › General Alarm
Issued 4 October 2006 Resolved
Renew and test warning beacons on both watertight doors.
Action required: 705 - Other - as specified
Due 25 December 2006
Resolved 13 December 2006
Resolution: Faxed invoice of purchase for lights.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 26 April 2006 Resolved
EDG failed during routine test. Make repairs prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2006
Resolved 27 April 2006
Lifesaving › Lifeboat › Propulsion Engine
Issued 3 February 2005 Resolved
Demonstrate proper operation of #1 lifeboat. Lifeboat engine would not start. Demonstration shall be to the satisfaction of the attending CG Marine Inspector or ABS Surveyor. Until repairs are completed and demonstrated, vessel is limited to 50 persons onboard.
Action required: 705 - Other - as specified
Resolved 18 February 2005
Fire Fighting › Structural - A Class Divisions › Ro-ro Cargo Spaces
Issued 8 September 2004 Resolved
Utilize ships SMS to notify company of nonconformity in regard to missing structural fire protection. Firestop missing in several places at wire runs.
Action required: 705 - Other - as specified
Resolved 9 September 2004
Resolution: Vessel contacted company with a nonconformity and a fire protection plan for the Watson class vessels was sent in reply. Also, plans were in motion to attain the proper amount and type of firestop.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 8 September 2004 Resolved
Vessel did not have an acceptable testing program for the fixed detection system, as witnessed by USCG inspectors during exam. Vessel must attain an acceptable testing program from company.
Action required: 705 - Other - as specified
Resolved 9 September 2004
Resolution: Ship utilized SMS to contact company with nonconformity regarding detection testing. Company repsonded with Watson class fire detection test procedure.
Fire Fighting › Fixed Deck Foam System
Issued 19 August 2003 Resolved
Make proper repair to damaged foam sprinkler piping in cargo hold #3D prior to next U.S. port departure but no later than 15Nov03. LEGACY COMPONENT DESC: Piping
Due 15 November 2003
Resolved 27 October 2003
Resolution: Foam sprinkler piping properly repaired.
Documentation › Safety/Response Plans/Programs
Issued 12 November 2002 Resolved
Provide onboard for Coast Guard inspection, proper color-coded Fire Protection Plans in accordance with IMO Assembly resolution A.654(16). LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 1 December 2003
Resolved 27 October 2003
Resolution: Proper Fire Protection Plans provided.

Ownership record