MAURY USCG vessel records Sign in
← All vessels

OCEAN ONYX

OCEAN ONYX is a 1973 mobile offshore drilling unit. The Coast Guard has recorded 70 inspections since 1988, most recently in March 2010, along with 142 deficiencies.

Records from 1988 to 2010. Most recent: inspection, 15 March 2010.

Built
1973
Last inspected
15 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8753366 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
299046
Flag
PANAMA
—
Maury page id
psix-299046

Inspections, by type

…with no type recorded24
Years with a record 20 calendar years (1988–2010)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it6481 - Regulatory (Subpart C or D), Gross Ton
4201 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LEVIATHAN Offshore Supply Vessel · MISLE 54678 · 30 September 1997 · activity 178605CAMERON Offshore Supply Vessel · MISLE 52690 · 14 October 1996 · activity 123724

Inspection history · 70

15 March 2010 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3711425
5 June 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2952128
12 May 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2930884
16 January 2007 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2856611
26 September 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2787040
12 September 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2776409
5 September 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2769839
4 September 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2776583
9 June 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2677786
25 January 2006 COC-MODU Annual
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2549888
20 October 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2518554
20 October 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2518592
8 December 2004 COC-MODU Renew
Type not classified · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2258912
26 January 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481548
26 January 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481581
5 October 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444629
22 September 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073580
8 September 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073283
25 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073136
19 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 33821
14 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061611
20 February 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766375
8 February 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 201180
13 October 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425003
8 December 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812528
13 October 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468536
16 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120897
19 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131885
20 October 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427587
23 February 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779425
15 February 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 71582
15 February 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 118596
5 February 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 773248
2 December 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111036
22 October 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1445279
30 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 178605
29 August 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1119847
23 June 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1112281
12 May 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1094644
12 May 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1103281
29 April 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1090377
13 March 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106127
13 November 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457422
14 October 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 123724
26 December 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873170
20 November 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458251
10 July 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882978
10 June 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 178258
1 December 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409204
15 August 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 685439
10 August 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 4833
7 December 1993 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1353552
30 August 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1137878
7 July 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1152463
14 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 10882
9 December 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438021
15 October 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 140113
21 May 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 954315
21 April 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263280
6 April 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254546
11 December 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255068
13 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904683
10 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216190
5 April 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231040
10 January 1991 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927843
16 February 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922013
7 February 1990 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234425
11 January 1990 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927342
25 January 1989 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032719
19 February 1988 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969556

Deficiency record · 142

Fire Fighting
Issued 5 October 2001 Resolved
CROP AND RENEW WASTED SECTION OF FIREMAIN COMING OFF SALT WATER SERVICE PUMP IN MACHINERY SPACE.
Condition: Unknown
Due 5 November 2001
Resolved 23 October 2001
Lifesaving
Issued 20 October 1998 Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 110% OR AN ALTERNATIVE TEST ACCEPTABLE TO [name withheld].
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Lifesaving
Issued 20 October 1998 Resolved
RENEW WINDOWS, LIFELINES AND LIFELINE BRACKETS TO LIFEBOATS NO.2 AND 4.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Lifesaving
Issued 20 October 1998 Resolved
RENEW AS ORIGINAL, FORWARD LIFEBOAT FALL BLOCK WHERE WASTED, ON LIFEBOAT NO.4. TEMPORARILY SECURE BOAT "OUT OF SERVICE" UNTIL PERMANENT REPAIRS AFFECTED AND APPROVED TO SATISFACTION OF CLASS SOCIETY OR COGNIZANT OCMI.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Fire Fighting
Issued 20 October 1998 Resolved
INSTALL APPROPRIATE A-CLASS FIREDOOR IN GALLEY AND SERVING LINE ENTRANCE TOMESSROOM, TO THE SATISFACTION OF CLASS SOCIETY AND [name withheld].
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Accommodation/Occupational Safety
Issued 20 October 1998 Resolved
PROPERLY MAKE WATERTIGHT BY STEEL INSERT HULL DECK PLATE IN AC HANDLING ROOM WHERE UNIT CONDENSATE DRAINS PENETRATE. MAKE REPAIRS TO SATISFACTION OF ATTENDING CLASS SURVEYOR.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Accommodation/Occupational Safety
Issued 20 October 1998 Resolved
CROP AND RENEW WASTED AND HOLED HANDRAILS THROUGHOUT RIG, AS NECESSARY.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Unknown
Issued 20 October 1998 Resolved
PROPERLY OUTFIT FORKLIFT WITH PORTABLE FIRE EXTINGUISHER, FORK SAFETIES, AND 4LB. DC EXTINGUISHER AT REFUELING STATION. RECOMMEND FORKLIFT UNIT BE REPLACED DUE TO AGED CONDITION.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Electrical
Issued 20 October 1998 Resolved
COMPLETE REPAIRS TO NO.8 DC GENERATOR AND REINSTALL PROPERLY. CONDUCT TESTOF REVERSE POWER RELAY OF BOTH AC GENERATORS.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Unknown
Issued 20 October 1998 Resolved
INSTALL PRESSURE SAFETY VALVE ON ELECTRIC EMERGENCY AIR COMPRESSOR IN ENGINE ROOM BETWEEN COMPRESSOR DISCHARGE AND ISOLATION VALVE.
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Fire Fighting
Issued 22 October 1997 Resolved
PROVIDE RECHARGED/CURRENT HYDRO'D SCBA CANNISTERS FOR ON TOUR FIRE FIGHTINGENSEMBLES
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Lifesaving
Issued 22 October 1997 Resolved
PROVIDE A TOTAL OF 4 TYPE 1 PFD'S FOR LIFEBOAT STATIONS #3 AND #4.
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Fire Fighting
Issued 22 October 1997 Resolved
PROVIDE MISSING GASKET AND APPLICATOR CHAINS FOR NOZZLES AT FIRE STATIONS #17 AND #4.
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Fire Fighting
Issued 22 October 1997 Resolved
PROVIDE BATTERY FOR SMOKE DETECTOR IN ADDITIONAL CREW QUARTERS ON DECK.
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Electrical
Issued 22 October 1997 Resolved
PROVIDE BULB FOR E-LIGHT IN CO2 BOTTLE BANK COMPARTMENT.
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Engineering
Issued 22 October 1997 Resolved
PROVIDE FUEL TRANSFER PROCEDURES AFT/PORT BULKHEAD
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Lifesaving
Issued 22 October 1997 Resolved
PROVIDE READABLE LIFERAFT INSTRUCTIONS AT ALL STATIONS
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Electrical
Issued 22 October 1997 Resolved
TEST RIG EMERGENCY SHUTDOWN(VENTILATION)AT ALL LOCATIONS AND SEND RESULTS TO [name withheld], TX
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Lifesaving
Issued 22 October 1997 Resolved
REMOVE ANTENNA WIRING FROM WAY OF L/B #1 DAVIT SHEAVES
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Lifesaving
Issued 22 October 1997 Resolved
PROVIDE RING BUOY AFT/PORT BULKHEAD
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Lifesaving
Issued 22 October 1997 Resolved
PROVIDE 4 HAND FLARES FOR EACH LIFE BOAT
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Lifesaving
Issued 22 October 1997 Resolved
REMOVE EXCESS WATER FROM BILGES OF ALL LIFEBOATS
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Lifesaving
Issued 22 October 1997 Resolved
PROVIDE A TOTAL OF 4 PERSONAL LIGHTS AND 2 NEW RETRO TAPE JOBS FOR RIG LIFEJACKETS
Condition: Unknown
Due 23 November 1997
Resolved 3 November 1997
Engineering
Issued 22 October 1997 Resolved
PROVIDE STURDY SIGHT GLASS SHIELDS FOR OIL STORAGE TANKS, PORT AFT.
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Lifesaving
Issued 22 October 1997 Resolved
LABEL ALARMS/ALARM LIGHTS THROUGHOUT RIG WHERE PAINT COVERED/MISSING.
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Construction/Loadline
Issued 22 October 1997 Resolved
REPAIR WEATHERTIGHT DOOR TO MCC#3-4 ROOM; BOTTOM GASKET HANGING, CHANNEL CORRODED.
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Navigation
Issued 22 October 1997 Resolved
REPAIR CRACKED STERN NAV LIGHT.
Condition: Unknown
Due 23 November 1997
Resolved 4 November 1997
Documentation
Issued 13 November 1996 Resolved
PROVIDE A CONSTRUCTION PORTFOLIO OR PROVE IT IS NOT REQUIRED.
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Accommodation/Occupational Safety
Issued 13 November 1996 Resolved
CONDUCT INTERNAL EXAM OF ALL PRESSURE VESSELS NO LATER THAN 01 APRIL 1997 AND SUBMIT ABS REPORT TO THIS OFFICE.
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Fire Fighting
Issued 13 November 1996 Resolved
PROVIDE TIME DELAY, SHUTDOWN AND SIRENS FOR CO2 PROTECTED SPACES OR PROVE THEY ARE NOT REQUIRED.
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Fire Fighting
Issued 13 November 1996 Resolved
PROVIDE TIME DELAY, SHUTDOWN AND SIRENS FOR CO2 PROTECTED SPACES (NORMALLY MANNED) OR PROVE THEY ARE NOT REQUIRED.
Condition: Unknown
Due 10 March 1997
Resolved 10 March 1997
Engineering
Issued 1 December 1994 Resolved
INSTALL LAGGING ON EXHAUST PIPE FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Electrical
Issued 1 December 1994 Resolved
Prove proper operation of battery powered emergency lighting in accommodations spaces.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Lifesaving
Issued 1 December 1994 Resolved
PROVIDE 1500 FEET OF AUXILLIARY LINE FOR LINE THROWING DEVICE.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Fire Fighting
Issued 7 December 1993 Resolved
REPAIR GENERAL ALARM BELL IN MAIN FLOOR LIVING QUARTERS.
Condition: Unknown
Due 7 January 1994
Resolved 18 January 1994
Unknown
Issued 7 December 1993 Resolved
PROVIDE FUELING STATION FOR FORKLIFT.
Condition: Unknown
Due 7 January 1994
Resolved 18 January 1994
Lifesaving
Issued 7 December 1993 Resolved
PROVIDE FOOD RATIONS ON ALL 4 LIFEBOATS.
Condition: Unknown
Due 7 January 1994
Resolved 26 April 1994
Accommodation/Occupational Safety
Issued 7 December 1993 Resolved
PROVIDE DOCUMENTATION OR DEMONSTRATE PROPER OPERATION OF PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 7 December 1993
Resolved 7 December 1993
Lifesaving
Issued 9 December 1992 Resolved
PROVIDE MANUFACTURER DATA AND FLAG STATE APPROVAL FOR USE OF 'DS' TYPE FORKLIFT IN CLASS I DIV I AREA.
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992
Accommodation/Occupational Safety
Issued 9 December 1992 Resolved
PROVIDE DOCUMENTATION OF ANNUAL TESTING OF ALL PRESSURE VESSL RELIEF VALVESOR TEST IN PRESENCE OF A USCG MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992
Lifesaving
Issued 9 December 1992 Resolved
REFILL PORT AIR CYLINDER ON LIFEBOAT #1._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 1993
Resolved 9 February 1993
Lifesaving
Issued 9 December 1992 Resolved
PROVIDE OF TESTING OF L/B RADIOS AND SUBMIT LOG ENTRY OF SAME TO [name withheld]._x001C_
Condition: Unknown
Due 10 January 1993
Resolved 9 February 1993
Lifesaving
Issued 9 December 1992 Resolved
MAKE SUB-SEA MAINTENANCE ROOM ELECTRICAL EQUIPMENT MEET THE REQUIREMENTS FOR CLASS I DIV I HAZARDOUS LOCATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992
Navigation
Issued 21 April 1992 Resolved
INSTALL WEDGES TO ELIMINATE ROCKING OF SEVERAL AIR BOTTLES.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Navigation
Issued 21 April 1992 Resolved
PROVIDE GAUGING REPORT FOR ALL 2400 PSI AIR BOTTLES. GUAGING SHOULD BE TAKEN WITH PARTICULAR INTREST IN END CONES AND IN WAY OF UPPER & LOWER RACKSUPPORTS. PROVIDE ORIGINAL THICKNESSES. CONDUCT GAUGING IN PRESENCE OF MARINE INSPECTOR._x001C_
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Navigation
Issued 21 April 1992 Resolved
INSTALL PIPE NIPPLES, BETWEEN AIR BOTTLES AND RELIEF VALVE RATED AT MAWP OFSYSTEM NOT TO BE LESS THAN THE RELIEF VALVE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Accommodation/Occupational Safety
Issued 11 December 1991 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION OR HYDROSTATICALLY TEST ALL TENSIONER BOTTLES AND PROVIDE FOR TESTING OF RELIEF VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Unknown
Issued 11 December 1991 Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF #2 DRAWWORKS LOSS OF VENTILATION ALARM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Engineering
Issued 11 December 1991 Resolved
HYDROSTATICALLY TEST PORT AND STBD FUEL TRANSFER HOSES (225 PSI) IAW 33 CFR155.800._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Deck/Cargo
Issued 11 December 1991 Resolved
PROVIDE EVIDENCE OF SATISFACTORY 5-YR CRANE WEIGHT TEST ON CRANES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Documentation
Issued 11 December 1991 Resolved
PROVIDE UPDATED FIRE CONTROL PLAN REFLECTING CURRENT FIXED CO2 SYSTEMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Lifesaving
Issued 11 December 1991 Resolved
PROVE PROPER OPERATION OF THE REMOTE LIFEBOAT LOWERING RELEASE FOR LIFEBOATS #1 AND #3._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Unknown
Issued 11 December 1991 Resolved
PROVE PROPER OPERATION OF THE AIR PURGE SYSTEMS LOCATED ON THE DRILL FLOOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Documentation
Issued 11 December 1991 Resolved
PROVIDE ON BOARD THE ORIGINAL CERTIFICATE OF FINANCIAL RESPONSIBILITY FOR THE VESSEL. (COPY ON BOARD)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Documentation
Issued 11 December 1991 Resolved
PROVIDE ON BOARD A VALID NPDES PERMIT PER 33 CFR 155.400._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Documentation
Issued 11 December 1991 Resolved
PROVIDE EVIDENCE OF A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY FOR THEOUTER CONTINENTAL SHELF PER 33 CFR 130-132._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Accommodation/Occupational Safety
Issued 11 December 1991 Resolved
PROVIDE FOR TESTING OF ALL PRESSURE VESSEL RELIEF VALVES IN PRESCENCE OF USCG MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Fire Fighting
Issued 11 December 1991 Resolved
REPLACE FIREMAIN PIPING IN FOLLOWING AREAS: 1. F/S #6 @ ELBOW 2. F/S #12 @ELBOW 3. HELO DECK MONITOR TO FIRST "T" IN FIREMAIN 4. PORT SIDE FUELING STATION AFT OF MOTORROOM TO HELO DECK 5. VICINITY OF CO2 ROOM AND REMOTE SHUTDOWNS._x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Lifesaving
Issued 11 December 1991 Resolved
RECHARGE VENTILATION AIR BOTTLES IN #4 LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Accommodation/Occupational Safety
Issued 11 December 1991 Resolved
HYDROSTATICALLY TEST OR REPLACE DRILL FLOOR AIR RECIEVER AND INSTALL AN APPROVED RELIEF VALVE. (HYDR TEST @ 1.25 MAWP)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Lifesaving
Issued 11 December 1991 Resolved
MAKE OPERATIONAL THE ENGINE IN LIFEBOAT #1._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Documentation
Issued 11 December 1991 Resolved
PROVIDE CURRENT IMO MODU ANNUAL RADIO INSTALLATION INSPECTION CERTIFICATE._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Lifesaving
Issued 11 December 1991 Resolved
REPLACE GASKETS ON #3 LIFEBOAT PERSONNEL DOORS PORT AND STBD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Lifesaving
Issued 11 December 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Construction/Loadline
Issued 11 December 1991 Resolved
RENEW VAPOR TIGHT BULKHEAD FROM MUDPIT/MUDPUMP ROOM TO UNCLASSIFIED AREAS FWD AND STBD BULKHEADS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Accommodation/Occupational Safety
Issued 11 December 1991 Resolved
REPAIR MUD PUMP MOTOR AIR DISCHARGE VENT PIPING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Construction/Loadline
Issued 11 December 1991 Resolved
MAKE OPERATIONAL THE PORT FWD CENTER COLUMN WATERTIGHT DOOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Unknown
Issued 11 December 1991 Resolved
PROVIDE EVIDENCE THAT THE FORKLIFT IS SUITABLE FOR THE CLASSIFIED AREA (ZONE 1)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1991
Resolved 11 December 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE WASTED COVERS ON WATER COOLER BY PORT AFT DERRICK LEG ON MEZZANINE DECK.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE ALL CHARRED WIRING AND PROPERLY INSTALL ALL WIRING RUNS AND CABLE TRAYS / SUPPORTS LOCATED PORT AFT DERRICK LEG ON MEZZANINE DECK.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROVIDE MISSING GLOBES AND COVERS FOR LIGHTS ON INTERIOR OF LIVING SPACES.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY INSTALL WIRING WITH BANDING FROM PORT PUMP ROOM THROUGH ACCESS TRUNK TO MAIN DECK (1" DIAMETER BRAIDED WIRE.)
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY INSTALL ALL 1 1/2" DIAMETER AND 1" DIAMETER WIRES ABOVE CABLE TRAYFORWARD PUMPROOM PORT SIDE (TIED UP CURRENTLY AND HELD IN PLACE WITH MANILLA LINE.)
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY MOUNT "LUBRICATING LP SHUT DOWN SWITCH" FOR PROPULSION MOTOR PORT PROPULSION ROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY INSTALL WIRING WITH BARE CONDUCTORS TO REMOTE OPERATED VALVE "V-3"PORT PUMP ROOM (TO ACTUATOR).
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REVISE UNIT OPERATIONS MANUAL TO MEET REQUIREMENTS OF 46 CFR 109.121 (C)(20) AND 46 CFR 109.121(C)(21).
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY MOUNT JUNCTION BOX ABOVE VALVE "V-3" PORT PUMP ROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE WASTED JOINT OF PIPING WITH DOUBLER PATCH BETWEEN MANUAL SEA INLET VALVE AND REMOTE OPERATED VALVE PORT PUMP ROOM._x001C_ _x001C_
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE SCOTCH CASTS WITH PROPER JUNCTION BOXES ON WIRES PORT AFT DERRICK LEG.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REMOVE DEAD ENDED WIRING INBOARD PORT PUMP ROOM BY SEA VALVE INLET.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
RENEW WIRE WAYS TO AREAS INBOARD PORT PUMP ROOM BENEATH REMOTE OPERATED VALVES ABOVE BILGE AREA.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE BROKEN JUNCTION BOX, PROVIDE PROPER JUNCTION BOX FOR SPLICED WIRES CONNECTED WITH WIRE NUTS PORT SIDE PUMP ROOM LOCATED BY REMOTE OPERATED VALVE "V-8"
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROVIDE MISSING GLOBES / GUARDS / BULBS ON LIGHTS FORWARD OF MAIN MOTOR BENEATH DECK GRATINGS STARBOARD PUMP ROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE WIRING WITH BARE CONDUCTORS. PROPERLY MOUNT JUNCTION BOX TO MANUALVALVE INDICATOR FOR DRILL WATER CROSS OVER.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY MARK FOR IDENTIFICATION ALL VALVES IN STARBOARD PUMPROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE WIRING WITH TAPED SPLICED JUNCTION TO ACTUATOR ON "BALLAST CST 7" SUCTION STARBOARD PUMPROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE WASTED SECTIONS OF VENTILATION PLENUM BELOW GRATINGS STARBOARD PUMPROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE WIRES WITH TAPED SPLICED JUNCTION TO VALVE "V-16" ACTUATOR JUNCTIONBOX STARBOARD PUMP ROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROVIDE PROPER INSTALLATION OF WIRING AND EXPLOSION PROOF JUNCTION BOXES_x001C_ ABOVE CATWALK BENEATH RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY INSTALL ALL VERTICAL RUNS OF WIRING BY PHONE UNIT IN CELLAR DECK.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
COMPLETE REPAIRS TO CABLE TRAYS, SECURING OF LOOSE WIRES AND MAKE PROPER FOR SUITABLE ZONE 1 INSTALLATION ALL ELECTRICAL EQUIPMENT IN MUD PIT AREA. _x001C_
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROVIDE ADEQUATE CONTAINMENT BENEATH FUEL OIL MANIFOLD AND FLANGES OUTSIDE ENGINE ROOM.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PAINT LIFEBOATS INTERNATIONAL ORANGE (BUFFING MAY BE AN ACCEPTABLE ALTERNATIVE.)
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROVIDE NON-SKID SURFACE FOR HELO DECK.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPAIR ALL OBSTRUCTION LIGHTS.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REMOVE ALL DEAD ENDED WIRING ON RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REMOVE ALL DISCONTINUED EXPLOSION PROOF LIGHTS AND JUNCTION BOXES ON RIG FLOOR. _x001C_
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY MOUNT ALL EXPLOSION PROOF JUNCTION BOXES LAYING ON CABLE TRAYS ON RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY SUPPORT ALL VERTICAL AND HORIZONTAL WIRE RUNS ON RIG FLOOR, CLOP /RENEW AS NECESSARY TO GOOD METAL ALL A WASTED CABLE TRAYS ON RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY INSTALL AND MOUNT EXPLOSION PROOF JUNCTION BOX ABOVE SUBSEA TV ROOM RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY INSTALL OR REMOVE DEAD ENDED WIRING INSIDE DRILLER'S CONSOLE RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROPERLY INSTALL OR REMOVE DEAD ENDED WIRING INSIDE DRILLER'S CONSOLE RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
PROVIDE GLAND FITTING FOR WIRING PENETRATION TO "RUCKER" CONTROL PANEL - RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Unknown
Issued 10 January 1991 Resolved
REPLACE WIRING / PROPERLY INSTALL WITH WASTED SHEATH LOCATED BEHIND MARTIN DECKER CONSOLE - RIG FLOOR.
Condition: Unknown
Due 10 January 1991
Resolved 10 January 1991
Electrical
Issued 11 January 1990 Resolved
REPLACE MISSING BOLTS ON EXPLOSION PROOF JUNCTION BOX ABOVE MUD PUMP #1.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Unknown
Issued 11 January 1990 Resolved
REPLACE COOLING FAN GUARD ON ROD OILING PUMP ON #2 MUD PUMP AND REPLACE PROCTECTIVE SHAFT COVER.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Unknown
Issued 11 January 1990 Resolved
RE-ATTACH GUARD FOR ROD WASH PUMP BY #2 MUD PUMP.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
POUR EYS FITTINGS ON PORTABLE FAN BY MUD PUMP #1.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Construction/Loadline
Issued 11 January 1990 Resolved
SEAL BULKHEAD PENETRATION IN DOWELL CEMENT UNIT ROOM. THIS ROOM IS ADJACENT TO CL I DIV II SPACE.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REPLACE NON- EXPLOSION PHONE UNIT WITH A TYPE APPROVED FOR CL. I DIV. II AREA ON CELLAR DECK HAND RAIL NEXT TO PIPE RACK.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Unknown
Issued 11 January 1990 Resolved
REFASTEN PROTECTIVE GUARD ON THE TRIP TANK PUMP ON THE CELLAR DECK.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REPLACE WASTED WIRE WAYS BY FOWARD SUBSEA SHOP..
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Fire Fighting
Issued 11 January 1990 Resolved
REPLACE MISSING FIRE EXTINGUISHER IN THE LAUNDRY ROOM (19B).
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Unknown
Issued 11 January 1990 Resolved
MAKE GAS TIGHT ALL BOUNDARIES IN CL I DIV II AREA FOR LAUNDRY ROOM.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Engineering
Issued 11 January 1990 Resolved
MAKE OPERABLE REMOTE OPERATED VALVE V5 IN STBD PROPULSION ROOM.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Engineering
Issued 11 January 1990 Resolved
REPLACE RIG FLOOR AIR RECEIVER FLANGE BOLTS WITH PROPER GRADE, DUE TO EXCESSIVE WASTAGE.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Unknown
Issued 11 January 1990 Resolved
RE-ATTACH GUARD ON DRILL WATER PUMP (PORT PUMP ROOM).
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Engineering
Issued 11 January 1990 Resolved
IN LINE CHECK VALVE FOR DRILL WATER PUMP INOPERABLE, LOCATION IN PORT PUMP ROOM.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Lifesaving
Issued 11 January 1990 Resolved
CORRECT THE SLIPPAGE IN THE #2 BOAT WINCH SYSTEM.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Lifesaving
Issued 11 January 1990 Resolved
POST INSTRUCTIONS FOR THE LIFERAFTS ON LOCATION THAT REFLECT THE TYPE OF RAFT WHICH IS INSTALLED.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Unknown
Issued 11 January 1990 Resolved
RENEW FLAME SCREENS IN THE FUEL VENTS AS NECESSARY 30X30 MESH.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Fire Fighting
Issued 11 January 1990 Resolved
MAKE REPAIRS TO FIREMAIN WHERE LEAKS WERE POINTED OUT.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Lifesaving
Issued 11 January 1990 Resolved
DERUST THE DAVIT ASSEMBLY, RUNNING GEAR HOOKS, ECT. ON THE #2 LIFEBOAT.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Documentation
Issued 11 January 1990 Resolved
PROVIDE A COPY OF THE ANNUAL PANAMANIAN INSPECTION WHEN COMPLETED.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Lifesaving
Issued 11 January 1990 Resolved
REPLACE THE TEMPORARY POWER SOURCE EMERGENCY LIGHT AT THE #2 LIFEBOAT.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Accommodation/Occupational Safety
Issued 11 January 1990 Resolved
REPLACE SEAL ON VENTILATION DUCT PASSING THROUGH ENGINE ROOM TO QUARTERS AREA.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Construction/Loadline
Issued 11 January 1990 Resolved
REPLACE BROKEN HAND RAIL ON PORT STERN BY #7 & #8 ANCHOR WINCHES.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REWIRE, REMOUNT OR REMOVE TWO EXPLOSION PROOF JUNCTION BOXES BEHIND MARTIN DECKER CONSOLE ON RIG FLOOR.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REMOVE OR INSTALL TO CLASS I DIV II STANDARD JUNCTION BOX ABOVE GAS VENT ALARM PANEL.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
PROVIDE EXPLOSION PROOF JUNCTION BOX FOR WIRE NUT CONNECTIONS BENEATH RUCKER MOTION COMPENSATION SYSTEM ON RIG FLOOR.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
PROVIDE SEALED FITTINGS FOR EXPLOSION PROOF SWITCHBOX FOR DRAW WORKS LUBE OIL PUMP LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Construction/Loadline
Issued 11 January 1990 Resolved
REPLACE WASTED WIRE WAY ABOVE DRAW WORKS ON RIG FLOOR.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REPLACE WIRING WITH BROKEN OUTER COVERING ON THE INBOARD SHALE SHAKER.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REMOUNT EXPLOSION PROOF SWITCH BOX IN WIRE WAY OVERHEAD IN PITS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
REMOUNT TWO (O2) EXPLOSION PROOF JUNCTION BOXES BY MUD CENTRIFUGAL PUMPS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Unknown
Issued 11 January 1990 Resolved
RE-ATTACH GUARDS TO MUD CENTRIFUGAL PUMPS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
POUR EYS FITTINGS ON #3, #4 MUD PIT AGITATOR MOTORS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990 Resolved
POUR EYS FITTING ON EXPLOSION PROOF SPEAKER HORN, IN MUD PITS.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Deck/Cargo
Issued 25 January 1989 Resolved
CLEAN AND GUAGE PITTED AREAS BENEATH THE RETENSION STRAPS ON THE HIGH PRESSURE BOTTLES (MOTION COMPENSATOR) 3 TOTAL.
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Lifesaving
Issued 19 February 1988 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Lifesaving
Issued 19 February 1988 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Lifesaving
Issued 19 February 1988 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.