← All vessels
LADY JANE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named LADY JANE
LADY JANE is a 1987 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2003, most recently in February 2026, along with 130 deficiencies, 1 operational control and 1 casualty investigation in 2016.
Records from 2003 to 2026. Most recent: inspection, 17 February 2026.
- Built
- 1987
- Last inspected
- 17 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 130 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2016
Identity
918082
299056
Flag
UNITED STATES
367078380 (licence lapsed)
Maury page id
psix-299056
Inspections, by type
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)57.0 ft × 20.0 ft × 8.0 ft
Registered tonnagegross 61 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEAN J AUTHEMENT · CHAUVIN, LA, UNITED STATES · built 1987
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portBRUNSWICK, GA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Simplified, Gross Ton
48 - Simplified, Net Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDC7878MMSI 367078380 · expired · compulsorily equipped · granted 15 September 2015, cancelled 7 March 2026
WCY4756MMSI not assigned · expired · voluntarily equipped · granted 16 June 1998, cancelled 16 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 27
17 February 2026
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8311305
30 January 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8072284
1 February 2024
In-Service Inspection · Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7859144
8 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7794997
9 June 2022
COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7457884
25 January 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7386469
9 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7324152
8 September 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7047268
28 January 2020
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6893644
11 September 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6805471
11 September 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6540288
3 January 2018
Examination of Repairs · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6329644
12 June 2017
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6166326
21 July 2016
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5940257
10 May 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5873327
8 January 2016
Hull Examination · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5793651
16 June 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4891128
5 June 2012
COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4342811
10 January 2012
Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4225941
3 January 2011
Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3919234
27 July 2009
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3547174
13 January 2009
Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3413443
1 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3208625
10 May 2007
Initial Certification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2930256
4 April 2007
Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2900854
30 April 2005
Type not recorded
No type recorded · Station Brunswick · USCG Southeast District (CGD-SE) · Activity 2346367
30 July 2003
Type not recorded
No type recorded · USCGC SHRIKE (WPB 87342) · USCG Northeast District (CGD-NE) · Activity 1868686
Deficiency record · 130
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2026
Resolved
Shutoff valves,installed so as toclose against thefuel flow, shall befitted in the fuelsupply lines, one atthe tankconnection and one at the en-gine end of the fuel line to stop fuelflow whenservicing accessories. Theshutoff valve at the tank shall beoper-able from outside the tank compart-ment, preferablyfrom an accessible po-sition on the weatherdeck. The emergency fuel shutoff did not close all the way.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 February 2026
Resolved
Except as otherwise provided inthis section,all vessels shall carrypy-rotechnicdistress signals as follows:(1)6hand red flare distresssignals,and 6 hand orange smokedistress sig-nals; or,(2) 12hand combination flare andsmoke distress signals. Vessels distress signals were expired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 February 2026
Resolved
Each life preserver carried on avessel must have at least 200 sq. cm(31sq. in.) of retroreflective material at-tached on its front side, at least 200 sq.cm on its back side, and at least 200 sq.cm of material on each of its reversiblesides.(b)Retroreflective material requiredbythis section must be Type I materialthat is approved under subpart 164.018of this chapter. 02 Lifejackets and 01 life rings need retro tape replaced.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 17 February 2026
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station. Vessel was missing the Oil Dischage Placard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2025
Resolved
On a Small Passenger Vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. The bilge high level alarm audible alarm was operating intermittently. Make repairs and demonstrate proper operation of the bilge high level audible alarm sounding continually in the presence of an attending Coast Guard Marine Inspector prior to carrying passengers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2025
Resolved
A pre-engineered fixed gas fire extinguishing system on a Small Passenger Vessel must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. During a test of the system, the engines would not shut down thereby making the system ineffective to extinguish an engine room fire. In the presence of a Marine Inspector, have the fire servicing company demonstrate the proper operation of the fixed fire extinguishing system to include alarm, engine shutdowns, and manual override at the operating station prior to carrying passengers.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 February 2025
Resolved
The movement of a small passenger vessel shall be under the direction and control of the master or a licensed mate at all times. The Owner/Master of the vessel did not have a current and valid Masters license. The Master's license expired on May 29, 2024, but continued to operate on an expired license. Prior to getting underway with passengers, provide an appropriately licensed captain on board. In addition, provide a copy of their license and proof of enrollment in a random drug testing program to the Coast Guard Marine Inspector. The licensed captain must be in direct supervision of anyone operating the vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 February 2025
Resolved
On a Small Passenger Vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. The bilge high level alarm in the engine room was inoperable and did not provide any warning at the operating station of flooding in that space. Make repairs and demonstrate proper operation of the bilge high level alarm in the presence of an attending Coast Guard Marine Inspector prior to carrying passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 February 2025
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. The vessels current Certificate of Documentation expired on August 31, 2024. Provide a Certificate of Documentation for the vessel and ensure the original is on board at all times whenever the vessel is underway.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a Small Passenger Vessel. The vessel had two, Type II Lifejackets mingled with the other lifejackets stowed in the aft life jacket locker. Provide two (02) additional Type I life jackets for a total of 51 Adult Life Jackets in accordance with the Certificate of Inspection. Vessel is reduced to the carriage of 46 passengers plus 3 crew until the replacement jackets are on board.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 February 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. During a test of the electric bilge pumps, the indication light for the bilge pump in compartment #1 was not operational. Make repairs and demonstrate proper operation of the light in the presence of an attending Coast Guard Marine Inspector
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 January 2025
Resolved
(b) All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section.
(1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel missed its 2024 inspection and has to conduct a new COI inspection before operating with passengers onboard.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 January 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. There were no Fire Buckets at the time of the inspection. Provide 3 fire buckets as required, properly mark and provide lanyards.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 February 2024
Resolved
Crop & Renew one wasted deck stiffener located in the forepeak tank (Void #1), port side, second stiffener from the forward bulkhead. Stiffener should be cropped from the keel bar to the next longitudinal frame. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 February 2024
Resolved
Crop & Renew one wasted deck stiffener located in the forepeak tank (Void #1), port side, third stiffener from the forward bulkhead. Stiffener should be cropped from the keel bar to the next longitudinal frame. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 27 February 2024
Resolved
Crop and Renew wasted section of the overhead located in the engine room, starboard side in the aft corner in way of the emergency fuel shut down cables. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 27 February 2024
Resolved
Properly clean and dry the bilge in the fish hold for inspection. Fish hold had a couple inches of standing water and debris and the condition of the hull in this space could not be inspected. Bilges must be ready for inspection by an attending Coast Guard Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 February 2024
Resolved
Crop and Renew entire section of wasted hatch coaming in way of the access hatch to the lazarette. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 February 2024
Resolved
Crop and Renew the entire wasted bulkhead stiffener on the transom in the lazarette. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 February 2024
Resolved
Crop and Renew the wasted section of the cap rail on the port side, aft deck in the corner. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 27 February 2024
Resolved
Crop and Renew several wasted sections of the bulwarks on the port side as marked and discussed. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 27 February 2024
Resolved
Either Crop and Renew wasted natural goose neck air ventilation pipe on the port side, midship or crop out area of the deck around where the air ventilation pipe was. The minimum plate insert size should be no smaller than 18 inch by 18 inch. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 27 February 2024
Resolved
Either Crop and Renew wasted natural goose neck air ventilation pipe on the starboard side, midship or crop out area of the deck around where the air ventilation pipe was. The minimum plate insert size should be no smaller than 18 inch by 18 inch. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 February 2024
Resolved
Crop and Renew cracked section of the hull at the starboard side corner of the transom. This cracked section is adjacent to a fresh water tank in the lazarette and is above the waterline. The owner has requested to make a temporary repair with a wrap around piece and intends to make permanent repairs no later than May 31, 2024 where the vessel will be hauled out again for a subsequent dry dock. No later than May 31, 2024, crop out the cracked section of that corner and insert a new plate with a minimum size of 18 inches by 18 inches. All the work completed must be completed and tested to the satisfaction of an attending Coast Guard Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 February 2024
Resolved
Crop and Renew wasted section of plating on the interior of the cork nozzle as discussed. All repairs must be to the satisfaction of an attending Coast Guard Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2023
Resolved
Sanitary inspection.At each inspection for certification and at every other vessel inspection lockers may be examined to determine that they are serviceable and in a sanitary condition. Locker under catch table that hold the children and adult life jackets is not sanitary, make locker and life jackets sanitary. Due oct 8
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2023
Resolved
Provide first aid kit, current one is expired and does not meet
46CFR184.710/160.041. Due October 8
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2023
Resolved
Vessels Fuel shutoff valves are not marked and does not meet the minimum
standard of Remote fuel shutoff stations must be marked in clearly legible
letters at least 25 millimeters (1 inch) high indicating purpose of the
valve and direction of operation. The vessel will be restricted from
carrying passengers after September 6, 2019 if the deficiency has not been
corrected to the satisfaction of an attending Coast Guard Marine Inspector." Due October 8
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2023
Resolved
Unless otherwise specified, vessel owners must pay the fees required by this subpart before inspection or examination services are provided. 2.10-20(a) General requirements. User Fees not paid.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 June 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Main engine shows signs of excessive oil leaks that is creating a excessive accumulation of oil and main engine exhaust is oil soaked and saturated and creates a fire hazard. 46CFR182.200(a)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 June 2022
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard. Compartment 2 (Engine Room) has excessive accumulation of oil that might create a fire hazard. 46CFR176.830(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 9 June 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Insulation for the main engine exhaust piping is oil soaked and saturated and creates a fire hazard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 June 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Main Engine will not automatically shut down. 46CFR181.420 (a)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 2 Adult Life jackets found unserviceable. Vessel is restricted to the carriage of not more than 46 passengers plus 3 crew until two type I PFD's are provided on board. 46CFR180.71(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2022
Resolved
All equipment, including switches, fuses, lamp holders, etc., must be suitable for the voltage and current utilized. Inspector observed evidence of melting cable to what appeared to be the fuel filter pressure switch, operator must identify cause and replace if needed.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 9 June 2022
Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel’s normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Operator unable to show availability of written count ashore at the vessel’s normal berthing location or with a representative of the owner or managing operator of the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 June 2022
Resolved
At each inspection for certification and at every other vessel inspection lockers may be examined to determine that they are serviceable and in a sanitary condition. Locker under catch table that hold the children and adult life jackets is not sanitary, make locker and life jackets sanitary.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 June 2022
Resolved
The Coast Guard shall evaluate emergency drills to ensure that each crew member is familiar with his or her duties in case of emergencies including response to fires, man overboard and abandon ship in accordance with 46 CFR 185.520 and 46 CFR 185.524. Because of material deficiencies on vessel, the Coast Guard was unable to witness emergency drills during this annual inspection. Owner must make crew available for drills.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 January 2022
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of Steel hull vessels. Repair washed out weld on strut. 46CFR177.300(b)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 September 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. No operable portable battery light at the access to the propulsion machinery space. 46 CFR 183.430
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2021
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Whistle non functional. 33 CFR 83.33
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2020
Resolved
Lighting fixtures: Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Guards were missing on outside deck lighting and Compartment 1 lighting on starboard side. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR183.410(a)
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 September 2020
Resolved
Unsafe practices: At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard. Compartment 2 (Engine Room) needs to be cleaned of oil. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR176.830 (b)
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 8 September 2020
Resolved
Unsafe practices: At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive trash, debris, or other matter that might create clog bilge pumping systems. Compartment 3 need to be cleaned of debris. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR176.830 (b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2020
Resolved
General requirements. In systems and applications where flexible hoses are permitted to be clamped, Double hose clamping is required where practicable. 2 locations on Keel cooler inlet port side need double hose clamps. Marked in blue tape. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR182.410(d)(1)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2020
Resolved
General design, installation, and maintenance requirements: Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Cable entering battery charger box is not protected from abrasion. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR183.200 (b)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2020
Resolved
Protection from wet and corrosive environments: Electrical equipment used in a machinery space must be dripproof. Breaker and terminal on port side aft ER bulkhead is not drip proof. Dripproof means enclosed equipment so constructed or protected that falling drops of liquid or solid particles striking the enclosure at any angle from 0 to 15 degrees downward from the vertical do not interfere with the operation of the equipment. A National Electrical Manufacturers Association type 1 enclosure with a dripshield is considered to be dripproof. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. 46CFR183.210(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 September 2020
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Provide Vessel 2 hand orange smoke or 2 red had flares per 160.021. 46CFR180.68
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 September 2020
Resolved
o Vessel is over 12 meters (39.4 Feet) and does not exhibit 225 degree masthead light forward with 3 mile visibility, 135 degree stern light visibility of 2 mile as described in 33CFR83.23(d). The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 8 September 2020
Resolved
Provide at least one crewmember on each vessel with CPR/First Aid training per NVIC 1-91 no later than 12APR18. Deficiency, if not addressed prior to the allotted due date become prior to carriage of passengers. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 September 2020
Resolved
o Fire bucket § 181.610 Fire bucket. A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21 / 2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’ must be stenciled in a contrasting color on each bucket. Vessels fire bucket need to be configured to meet the regulations. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2020
Resolved
Lifesaving equipment markings 185.604(f) The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Forward outside seating and port side forward signs are missing. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 September 2020
Resolved
Charts and nautical publications (a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; (b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. 184.420 The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2020
Resolved
Sanitary inspection.At each inspection for certification and at every other vessel inspection lockers may be examined to determine that they are serviceable and in a sanitary condition. Locker under catch table that hold the children and adult life jackets is not sanitary, make locker and life jackets sanitary. The vessel will be restricted from carrying passengers after October 8, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.46CFR176.818
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 September 2020
Resolved
A vessel when engaged in trawling, by which is meant the dragging through the water of a dredge net or other apparatus used as a fishing appliance, shall exhibit Two all-round lights in a vertical line, the upper being green and the lower white, and a shape consisting of two cones with their apexes together in a vertical line one above the other 33CFR 83.26(b)(i)
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Forepeak port side upper deck is wasted. 46CFR 177.300
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 January 2020
Resolved
A submersible electric bilge pump must be listed by an independent laboratory as meeting the requirements in UL 1113. Forward submersible electric bilge pump replaced with non UL 1113 pump. 46CFR182.520(e)(1).
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Forepeak starboard side upper deck is wasted. 46CFR 177.300
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Starboard Side top deck under the rest room deck completely wasted. 46CFR 177.300
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 January 2020
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Main engine shows signs of excessive oil leaks. 46CFR182.200(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 January 2020
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. There is a Soft Patch transmission cooler. 46CFR182.200(a)
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Bottom longitudinal frame port side engine room is wasted. 46CFR177.300
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 28 January 2020
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard. Engine Room has excessive oil accumulation. 46CFR176.830(b)
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 January 2020
Resolved
At each inspection for certification and at every other vessel inspection all required guards and protective devices must be in satisfactory condition. Winch guard Welds have failed. 46CFR176.830(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. 5 welds have cracked and or wasted on the rail courses on main deck . 46CFR177.300
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. 2 Transom transverse frames are wasted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 28 January 2020
Resolved
A vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Rudder support frames are wasted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 28 January 2020
Resolved
All accessible parts of the vessel’s underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Make forward of the collision bulkhead available for inspection. 46CFR176.610(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 September 2019
Resolved
Vessel will fail to undergo a annual inspection by 12SEP19 which is past its 3 month anniversary date of 12JUN2019 as required by 46CFR176.500(b)(1). Vessel is restricted operating with passengers after 12SEP19 to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 September 2018
Resolved
Vessels pre-engineered fixed gas fire system in the engine room does not shut off the generator and does not meet the minimum standard of automatically shutting down all engines that draw air from it in the protected space per 46CFR181.420(a)(3). Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger defs if they become past the due date noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 September 2018
Resolved
Vessels bilge high level alarm in compartments 1,2,3,4 were not operating properly and does not meet the standard of visual and audible alarm must be provided at the operation station per 46CFR182.530(a) Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger defs if they become past the due date noted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 September 2018
Resolved
Vessels automatic bilge pump visual indicators for compartments 1,2,3,4 were not operating properly abd does not meet the standard of visual indications must be at the operation station. Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger defs if they become past the due date noted.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 September 2018
Resolved
Vessels starboard side aft engine room celling is damaged so that the fixed gas extinguishing system would escape the space in the event of a discharge and does not meet the standard of the system may only be installed with a gross volume of not more than 2000 cubic feet. Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger defs if they become past the due date noted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2018
Resolved
Vessel is missing one 2-A fire extinguisher as required by certificate of inspection per 46CFR181.500(a). Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
Vessels has several dead end wires and does not meet the standard of minimizing accidental contact with electrical installations per 46CFR183.200(c) . Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. The serval areas were discussed with vessel rep, identified and explained. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
Two locations in engine room (outlet box aft and distribution panel are exposed and not drip proof as required by46CFR183.210(a)(1). Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
Various location on the weather deck had exposed electrical equipment that was not watertight as required by 46CFR183.210(b). Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. The various locations were discussed with vessel rep, identified and explained. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
Vessel has several locations where twist on wire nuts were not being correctly used per 46CFR183.340(i) and pressure type connectors that did not meet UL 486(A) (IE. Not heat shrink connections) per 46CFR183.340(b). Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. The various locations were discussed with vessel rep, identified and explained. Def will become prior to carrying passenger def if they become past the due date noted.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 September 2018
Resolved
Remove the accumulation of oil IAW 46CFR 176.830(b). Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
Engine room starting wires were not secured and laying on the deck. Install with metal supports as required by 46CFR182(340(b)(4). Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
battery must be mounted in trays per46CFR183.350(c). Generator batteries not in trays. Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
Vessel is utilizing an extension cord vie existing approved arraignment in the aft starboard side galley bulkhead leading to the aft deck. Installation must be IAW 46CFR183.340. Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 September 2018
Resolved
Replace outlet cover in the main deck aft starboard side galley. Currently it is off and is a electrical hazard per 46CFR183.200. Vessel has 14 days to correct to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 September 2018
Resolved
Vessels trawling gear arrangement is constructed so that the equipment is being operated over top of the passengers. Vessel must provide a plan on how they intend to prove this equipment is suitable for the service in which its employed IAW 46CFR176.840. Vessel has 30 days to submit a plan to the satisfaction of a Coast Guard Marine Inspector. Def will become prior to carrying passenger def if they become past the due date noted
Construction/Loadline › Penetrations › Weld
Issued 8 February 2018
Resolved
Replace wasted keel cooler piping and test (NDT) in the presence of the attending USCG Marine Inspector IAW 46 CFR 182.422
Construction/Loadline › Hull › Weld
Issued 8 February 2018
Resolved
Repair/Replace wasted steel on cort nozzle IAW 46 CFR 176.600(d) / 46 CFR 182.200(a)
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 February 2018
Resolved
Ensure all valves are capable of full closure for keel closure hull penetration IAW 46 CFR 182.422(b)
Construction/Loadline › Structures › Manhole
Issued 8 February 2018
Resolved
Crop and Replace all hatches so that they are watertight, have securing devices and attached to the hatch frame by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2017
Resolved
Permanently mount bilge high level alarm in engine room per 46CFR182.570(a)(2).
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 12 June 2017
Resolved
Provide 1 floating watertight prior to non daylight operations per 46CFR180.70(d).
Communications › Radio Communications › VHF Radiotelephone
Issued 12 June 2017
Resolved
Enable DSC VHF capabilities past the baseline per 46CFR80.905.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 12 June 2017
Resolved
Provide a marine operators permit or higher class license to all persons who operate the marine radio per 47CFR80.159(e)(1).
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2016
Resolved
01-Demonstrate proper operation of all bilge high level alarms prior to carrying passengers and to the satisfaction of an attending Coast Guard Marine inspector in accordance with 46CFR182.530
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 July 2016
Resolved
02-Demostrate proper operation of the emergency fuel shut offs prior to carrying passengers and to the satisfaction of an attending Coast Guard Marine inspector in accordance with 46CFR182.455(b)(4)
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 July 2016
Resolved
03- Properly install a forward mast head light with an arch of visibility of 225 degrees and a stern navigational light with a arch of visibility of 135 degrees in accordance with 33CFR83. 22 and 23. The all around light is only acceptable for a vessel less than 12 meters (39.4 feet) in accordance with 33CFR83.23(d)
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 21 July 2016
Resolved
04- Install both port and starboard running lights in a vertical position in accordance with 33CFR84.02. Running lights are currently positioned in a horizontal arrangement.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 July 2016
Resolved
05- Properly post all pages of the COI in a conspicuous place so that passengers can see it in accordance with 46CFR176.302.
Documentation › Certificates/Documents › Stability Letter
Issued 21 July 2016
Resolved
06-Properly post stability letter dated April 23rd, 2007 in the operating station so it can be viewed by the master in accordance with 46 CFR 176.306
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 July 2016
Resolved
07- Provide a safety radio certificate in accordance with 40CFR80
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 July 2016
Resolved
08- Provide and post emergency instructions that meets the requirements of 46CFR185.510 & .512
Documentation › Markings/Placards › Lifejacket Placard
Issued 21 July 2016
Resolved
09- Provide and post a life jacket placard for every type lifejacket onboard or need to provide 4 of the York type PFD's
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 21 July 2016
Resolved
10- Remove all power strips in the operating station in accordance with 46CFR183.200.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 July 2016
Resolved
11- Provide suitable covers for all exposed lighting in the engine room 46CFR183.200.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 January 2016
Resolved
Remove all oily water mixture from the bilges in the machinery space and properly dispose of the same. Bilges should be pumped to a minimum content at all times in accordance with the vessel's stability letter.
Engineering › Bilge Water Management System › Pump
Issued 12 January 2016
Resolved
Make repairs and demonstrate proper operation of the float activation switch in way of the electric submersible bilge pump in the machinery space.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 January 2016
Resolved
Properly repair wasted through hull pipe in the foward space that penetrates the bulbous bow to the satisfaction of an attending Coast Guard Marine Inspector.
Lifesaving › Hand Flares › Not on Board
Issued 16 June 2014
Resolved
Vessel must have 6 orange smoke flares. 46 CFR 185.614
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 June 2014
Resolved
Lifebuoy light lanyard is wasted and must be renewed. 46 CFR 180.70(d)(3)
Lifesaving › Lifefloat › Serviceable
Issued 16 June 2014
Resolved
One of the two required lifefloats is in unservicable condtion. 46 CFR 180.175
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 June 2014
Resolved
Life jacket stowage was not marked in accrodance with regulations. 46 CFR 185.604
Communications › Radio Communications › EPIRB
Issued 16 June 2014
Resolved
EPIRB hydrostatic release expired. 46 CFR 180.64. Item must be corrected prior to sailing beyond 3 NM from land.
Communications › Radio Communications › EPIRB
Issued 16 June 2014
Resolved
EPIRB NOAA registration expired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2014
Resolved
First aid kit was not of the approved type and missing required items. 46 CFR 180.710
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 16 June 2014
Resolved
Fuel oil vent pipe partially clogged with paint. 46 CFR 182.20-35 (Old T)
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 June 2014
Resolved
Fill pipe for fuel oil not marked. 46 CFR 182.23-30 (Old T)
Engineering › Bilge Water Management System › Pump
Issued 16 June 2014
Resolved
Vessel did not have portable hand pump capable of pumping directly over the side. 46 CFR 182.510(b)(2)
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 16 June 2014
Resolved
Exhaust lagging was oily and smoking, possible leak. 46 CFR 182.430
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2012
Resolved
Out of date and needed restocking
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2012
Resolved
Connectors corroded
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2008
Resolved
Several items in first-aid kit were beyond expiration date.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 May 2008
Resolved
Lanyards on floatlights for both life floats were deteriorated and needed to be replaced. Vsl restricted to L, B, & S route until this is corrected.
Lifesaving › Launching Appliances › Release Mechanism
Issued 1 May 2008
Resolved
Hydrostatic release for EPIRB was beyond expiration date. Vsls route restricted until new release is installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 June 2007
Resolved
The generator does not shut down when system is activated, the main engine does.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 10 May 2007
Resolved
Vessel did not have a fixed fire extinguishing system in the engine room as required.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2007
Resolved
Waterlight did not have a lanyard attached.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 May 2007
Resolved
Storage areas for lifejackets were not properly marked.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 10 May 2007
Resolved
Vessel missing 3 red flares and 3 orange smokes for the route requested.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 10 May 2007
Resolved
Fuel tank vents did not have flame screens installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 10 May 2007
Resolved
Portable extinguisher near exit of passenger space not properly mounted.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 May 2007
Resolved
Emergency instructions list not posted.
Casualty record · 1
10 May 2016Routine · role: Involved in a Marine Casualty · activity 5873327
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.