Records from 1988 to 2022. Most recent: inspection, 18 March 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
18 March 2022
SIP Initial Entry
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7414391
28 May 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 801778
14 May 1998
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364752
23 May 1997
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386090
20 September 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 828671
14 August 1996
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1411344
3 May 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1083698
12 April 1995
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355198
9 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 371304
6 July 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1423970
21 April 1994
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1456159
6 May 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1138965
12 April 1993
MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1146512
17 April 1992
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1258826
17 April 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1261764
21 March 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1318315
7 June 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015484
7 June 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1250716
14 February 1991
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 918824
1 February 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 926378
22 January 1990
Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902909
11 May 1989
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 892886
18 February 1988
Hull Examination · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1336746
Lifesaving
Issued 12 April 1995
Resolved
PROVIDE PROOF OF PURCHASE OF LIFE JACKET LIGHTS FOR ALL LIFE JACKETS. VESSEL RESTRICTED FROM OPERATING WITH PASSENGERS UNTIL COMPLIANCE.
Condition: Unknown
Due 12 May 1995
Resolved 1 May 1995
Construction/Loadline
Issued 21 April 1994
Resolved
MAKE PERMANENT REPAIRS TO THE #1 AND #2 INTERNAL VERTICAL BULKHEADS, WHERE LEAKING, STARBOARD SIDE INFLATION TUBE. VESSEL IS PROHIBITED FROM THE CARRIAGE OF PASSENGERS PENDING COMPLIANCE.
Condition: Unknown
Due 21 April 1994
Resolved 21 April 1994
Fire Fighting
Issued 12 April 1993
Resolved
PROVIDE PORTABLE HAND FIRE/BILGE PUMP WITH 5 GPM CAPACITY.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Lifesaving
Issued 12 April 1993
Resolved
PROPERLY LABEL ALL PFD'S.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Navigation
Issued 12 April 1993
Resolved
PROVIDE MAGNETIC COMPASS.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Documentation
Issued 18 February 1988
Resolved
PROVIDE COPY OF AND PLACE ON BOARD FCC FORM 824, SAFETY RADIO TELEPHONY CERTIFICATE. ROUTE IS RESTRICTED TO NOT MORE THAN 1,000 FEET FROM SHORE UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988