Records from 2001 to 2022. Most recent: inspection, 1 February 2022.
Inspection history · 33
1 February 2022
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7412609
27 January 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386703
6 January 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7120127
26 November 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6862365
15 February 2019
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6621388
3 April 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6385086
18 March 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6377693
28 February 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6366483
13 February 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6363699
1 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6348793
24 January 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6343041
17 January 2018
Type not recorded
No type recorded · USCGC OLIVER BERRY (WPC 1124) · USCG Oceania District (CGD-O) · Activity 6340916
18 December 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6326327
31 March 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6114861
2 February 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6082461
14 December 2016
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6051768
14 August 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5973913
9 July 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5945508
13 January 2016
Administrative Inspection · Drydock Exam · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5792209
3 March 2014
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4810027
28 June 2012
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4360360
8 October 2008
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3340939
11 October 2007
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3077726
6 June 2006
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2672233
15 September 2005
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2504204
23 September 2004
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2203153
9 August 2004
Annual Inspection · Administrative Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2158184
16 October 2003
Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1937927
21 August 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1663549
19 July 2002
Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1644989
6 November 2001
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1076094
20 August 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1072594
17 July 2001
Hull Examination · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362371
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 January 2022
No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. The vessel did not conduct a dry dock inspection before the vessel's anniversary date. The vessel needs to conduct a credited dry dock.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 January 2021
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: a means to reset device used to automatically shut down ventilation systems and engines. During inspection override switch did not re-energize engines.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2021
Resolution: Marine Inspector verified proper operation of pre-engineered fixed gas fire extinguishing system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 February 2019
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shutdown all engines that draw intake air from within the protected space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2019
Resolution: Marine Inspector verified functionality of fixed gas fire extinguishing system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2019
Resolved
Satisfactory master power sea trials to test the propulsion/steerage capabilities of the vessel in the presence of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2019
Resolution: Attending Marine Inspector verified sucessful sea trials.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2019
Resolved
Satisfactory crew drills are to be conducted in accordance with the prescribed emergency instruction loist in the presence of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2019
Resolution: Attending marine inspector verified sucessful crew drills.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 15 February 2019
Resolved
Provide a working float water light for the vessel's ring buoy.
Restricted to daylight operations.
Action required: 705 - Other - as specified
Resolved 28 February 2019
Resolution: Marine Inspector verified working float water light on vessel's ring buoy.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 February 2019
Resolved
Provide a working light for the installed compass at the helm.
Restricted to daylight operations.
Action required: 705 - Other - as specified
Resolved 28 February 2019
Resolution: Marine Inspector verified working light for installed compass.
Stability › Unintentional Flooding › General
Issued 1 February 2018
Resolved
Conduct over collar stress test in acoordance with MTN 01-8. 46 CFR 176.100(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 28 February 2018
Resolution: Stress test conducted.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 14 December 2016
Resolved
Replace the name of the vessel on the port and starboard hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: Rectified to the satisfaction of the Coast Guard MI.
Lifesaving › Lifebuoys › Serviceable
Issued 14 December 2016
Resolved
Replace wasted ring buoy grab line. Attach light to the body of the ring buoy with a corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: Operator purchased a new grab line and the light was attached correctly.
Navigation › Hydrodynamic Effects › Other Hydrodynamic Effects
Issued 14 December 2016
Resolved
Replace starboard side collar fasteners #9, #17, #25 and port side fasteners #12 and #18. Number value 0 at bow to 37 at stern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: Rectified to the satisfaction of the attending MI.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 December 2016
Resolved
Passenger count reduced to 15 based on 17 servicable adult lifejackets and 1 child found onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: Operator purchased new lifejackets to reflect passenger count on the valid COI.
Navigation › Piloting/Steering › Marine Charts
Issued 14 December 2016
Resolved
Provide current charts, light list, tide table, and coast pilot for operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 12 January 2017
Resolution: Current publications found onboard. Charts are for operating area and up to date.
Communications › Radio Communications › EPIRB
Issued 14 December 2016
Resolved
Mount EPIRB in a location that allows EPIRB to float free without obstructions above.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: The EPIRB is now mounted in a float free area on the vessel.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 14 December 2016
Resolved
Clean or renew terminal connections, found oily, connected to the bus bar located port side, immediately aft of the port main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: Bus bar was replaced in kind.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 December 2016
Resolved
Renew and replace wasted cooling water flexible hose located after the thru hull valve penetration on the port and starboard main engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: Cooling water flexible hose was replaced in kind.
Engineering › Fuel Oil Service System › Hose
Issued 14 December 2016
Resolved
Replace non-approved flexible fuel hose beginning at the fuel filter (located starboard side inside of the center console) to the bulkhead penetration in the engine room with approved fuel hose IAW Subchapter T.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 12 January 2017
Resolution: Fuel hose in compliance with vessel's approved plans. Purchased by operator and placed into service.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 December 2016
Resolved
Install double clamps on the flexible hose connection for cooling water at the thru hull penetration in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: MI verified double clamps installed on the flexible hose connections.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2016
Resolved
Install wiring support every 24 inches for the conductors located in the engine compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: Wiring supports replaced every 24 inches in the engine room.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 14 December 2016
Resolved
Replace corroded positive conductor and grounding conductor connections on the port and starboard main engine starters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: Corroded conductors renewed and placed back into service.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 14 December 2016
Resolved
Replace corroded conductor connections to the bus bar located inside of the center consol on the starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: Bus bar connections renewed and placed back into service.
Electrical › Electrical Distribution System (service) › Conductor
Issued 14 December 2016
Resolved
Replace corroded conductor connections for the bilge pump switches located inside of the center console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: MI verified corroded conductors replaced in kind.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2016
Resolved
Properly secure the dead end wire connected to the fuel gauge inside of the center console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: MI verified dead end conductor connected to ground.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 14 December 2016
Resolved
Replace corroded terminal connections on each positive and negative battery conductor connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: MI verified battery terminal connections renewed.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 December 2016
Resolved
Engine room bilge float switch is not permanently installed/mounted. MI discovered float switch floating freely in the bilge and the switch will not activate as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 14 December 2016
Resolution: Bilge float switch was properly installed so it does not float free in the bilge.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 14 December 2016
Resolved
The starboard main engine exhaust was found leaking water at the flexible hose connection just before the muffler. Refit the port and starboard main engine exhaust flexible hose, located before the muffler, with double clamps and ensure no water is leaking from the exhaust system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 30 December 2016
Resolution: Stbd main engine exhaust piping is no longer leaking cooling water and has double clamps on the flexible piping.
Engineering › Steering Gear System › Rudder Bearing
Issued 14 December 2016
Resolved
MI discovered the port rudder thru hull fitting leaking water into the engine room during underway sea trials at a rate of 1 gallon per hour. Replace port rudder thru hull fitting and tighten so no water enters the engine room through the fitting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: MI verified the port rudder thru hull penentration was no longer leaking. Operator installed a new O-ring for the penetration per the manufacturer's instructions.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 December 2016
Resolved
Provide lagging on the port and starboard main engine exhaust from the turbo charger to the first elbow of piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: MI verified temps on the main engine exhaust with an infrared temp gauge. Temps do not exceed 150 deg F and lagging is not required.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 14 December 2016
Resolved
Renew nuetral ground conductor connection on the port main engine located above the shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2016
Resolved 22 December 2016
Resolution: MI verified the operator renewed the grounding connection.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 January 2016
Resolved
Vessel did not have paperwork proving enrollment in a DAPI program. Must provide proof prior to operation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2016
Resolution: Vessel representative provided appropriate DAPI paperwork
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 January 2016
Resolved
12 adult lifejackets identified as excessively faded; master required to replace
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 1 February 2016
Navigation › Piloting/Steering › Marine Charts
Issued 13 January 2016
Resolved
Chart not up-to-date
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 22 January 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 June 2006
Resolved
Post SPV decal in a visible location on the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Resolution: SPV decal issued at the completion of the inspection and placed in the proper location.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 6 June 2006
Resolved
Create lifesaving equiptment checklist.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 June 2006
Resolved
Replace hydrostatic release for EPIRB.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2006
Resolved 27 July 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 June 2006
Resolved
Post lifejacket donning placard in a location that is visible to the passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2006
Resolved 27 July 2006
Lifesaving › Buoyant Apparatus › Serviceable
Issued 6 June 2006
Resolved
Replace BA with LF. Make repairs to current BA until it can be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2006
Resolved 27 July 2006
Engineering › Bilge Water Management System › Hose
Issued 6 June 2006
Resolved
Replace hose on the portable bilge pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2006
Resolved 27 July 2006
Electrical › Electric Supply System (service) › Cable
Issued 6 June 2006
Resolved
Remove all loose wiring from overhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 June 2006
Resolved
Conduct underway drills with CG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 31 July 2006
Construction/Loadline › Hull › Side Shell
Issued 6 June 2006
Resolved
Repair whole iwo port bow.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Engineering › Steering Gear System › Fastener
Issued 6 June 2006
Resolved
Repair bushing on the port steering rod on the inside rod. Replace with proper bolt and nut.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Construction/Loadline › Hull › Bracket
Issued 6 June 2006
Resolved
Repair bow u-bolt fitting.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Construction/Loadline › Hull › Side Shell
Issued 6 June 2006
Resolved
Complete repairs to the starboard aft pontoon and make ready for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Construction/Loadline › Hull › Side Shell
Issued 6 June 2006
Resolved
Repair separation of pontoon from collar port side aft.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 27 July 2006
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 6 June 2006
Resolved
Repair hand holds on inside starboard side for passengers, replace all straps that are worn in excess of 50%.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 27 July 2006
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 September 2005
Resolved
Provide captain with valid Masters License.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2005
Resolved 15 September 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 August 2004
Resolved
Provide brackets for portable fire extinguishers as required by thier uUL label.
Due 9 September 2004
Resolved 23 September 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 August 2004
Resolved
Provide identification markings for the fixed firefighting manual pull handle.
Due 9 September 2004
Resolved 23 September 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 August 2004
Resolved
Provide copy of annual servicing certificate for the fixed firefighting system.
Due 9 September 2004
Resolved 23 September 2004
Engineering › Fuel Oil Service System
Issued 19 July 2002
Resolved
Provide label for emergency fuel oil valve cutoffs in accordance with 46 CFR 182.455. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 26 July 2002
Resolved 21 August 2002
Communications › Radio Communications
Issued 19 July 2002
Resolved
Replace hydrostatic release for EPIRB in accordance with 46 CFR 185.728. EPIRB will be maintained in a float free condition until hydrostatic release is replaced. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 26 July 2002
Resolved 21 August 2002
Lifesaving › Lifebuoys
Issued 19 July 2002
Resolved
Replace grab line for ring life buoy in accordance with 46 CFR 180.70. LEGACY COMPONENT DESC: Grab line
Condition: Improper/Lack of Maintenance
Due 26 July 2002
Resolved 21 August 2002
Construction/Loadline
Issued 17 July 2001
Resolved
Mark vessel with Hailing port and vessel name IAW 46CFR185.602._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 2001
Resolved 28 August 2001
Navigation
Issued 17 July 2001
Resolved
Install navigation lights IAW 46CFR183.420 prior to night time operations._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 July 2001
Resolved 28 August 2001
Documentation
Issued 17 July 2001
Resolved
Provide Certificate of Documentation IAW 46CFR67.7.
Condition: Unknown
Due 17 August 2001
Resolved 28 August 2001
Documentation
Issued 17 July 2001
Resolved
Provide a FCC Safety Radio Certificate IAW 46CFR184.502._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 2001
Resolved 28 August 2001