MAURY USCG vessel records Sign in
← All vessels

EW SNOWDON

EW SNOWDON is a 1984 freight ship. The Coast Guard has recorded 29 inspections since 1988, most recently in February 2009, along with 17 deficiencies and 2 operational controls.

Records from 1988 to 2009. Most recent: operational control imposed, 6 February 2009.

Built
1984
Last inspected
6 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8317356 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
299835
Flag
LIBERIA
—
Maury page id
psix-299835

Inspections, by type

…with no type recorded20
Years with a record 17 calendar years (1988–2009)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it6368 - Convention (Subpart B), Gross Ton
2740 - Convention (Subpart B), Net Ton
6368 - Dead Weight, Ton
10389 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

6 February 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3413319
4 February 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3413362
13 January 2009 PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3393176
7 November 2008 Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3356943
14 August 2008 ISPS I Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3317746
6 August 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3290714
5 August 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3289911
29 March 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3169065
19 June 2007 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2966713
24 October 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2807276
20 January 2005 ILO-147 Exam · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2278163
5 November 2003 Security Inspection · Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1942376
17 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292010
22 March 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275959
13 March 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275656
30 June 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 417430
12 August 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 406830
12 March 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 388882
7 September 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 382428
26 April 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 464204
21 October 1994 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 371702
24 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 446630
30 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 369878
20 July 1993 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 359677
18 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 515628
7 December 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 488634
22 June 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 351519
1 November 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 340012
29 March 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 322229

Deficiency record · 17

Deck/Cargo › Cargo Transfer (solid) › General
Issued 7 November 2008 Resolved
During the deck walk, it was brought to the attention of the PSCO that the forward crane boom fell during operation this morning. There is visible damage to the handrails on top of the forward deck house. It was also noted that paint has been scraped off the boom in the vicinity of the impact with the hand rails. Repair, inspect structural integrity and conduct operational test of fwd deck crane.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 4 February 2009
Resolution: Received class report attesting to the required repairs.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 7 November 2008 Resolved
A static liquid pressure test has not been conducted to bunkering lines in accordance with 33 CFR 156.170. The vessel is prohibited from bunkering in U.S. waters until the required test is conducted and documented.
Action required: 703 - Prior to bunkering operations
Due 7 November 2008
Resolved 8 November 2008
Resolution: Received documentation from Master stating Bunker Lines were hydrostatically tested in accordance with 33 CFR 156.170.
Documentation › Logs/Records › Oil Record Book
Issued 19 June 2007 Resolved
Vessel's oil record book had improper log entries about its oily water separator. There were several entries stating that vessel was able to pump from the bilge, bilge tank, and clean bilge tank all at once to send through the oily water separator. It was found that all must be pumped to bilge tank which is pumped through the oily water separator. Rectify Def by entering proper log entries
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 March 2008
Resolution: PSCO reviewed the said Oil Record Book and found that all entries to be true and accurate statements of record.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 20 January 2005 Resolved
The boiler fuel oil supply piping filter leaks excessively. SOLAS 74A I/II.
Condition: Unknown
Due 20 January 2005
Resolved 20 January 2005
Resolution: Corrected satisfactory.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 20 January 2005 Resolved
Steam piping located in the STBD forward area of the lube oil purifier space leaks excessively resulting in failure of the protective coating systems (paint) & damage to the underlying metal structure. SOLAS 74A I/II.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 25 October 2006
Engineering › Electric Propulsion System › Circuit Breaker (overload/over current protection)
Issued 20 January 2005 Resolved
Earth detection system for the 100 volt electrical distribution panel shows that the system is grounded.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 25 October 2006
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 20 January 2005 Resolved
#2 ship's service generator high pressure fuel delivery lines are not protected with a jacketed piping system.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 25 October 2006
Engineering › Lubricating Oil Service System › Piping
Issued 20 January 2005 Resolved
Machinery space machinery & containments are covered with oil.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 25 October 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 20 January 2005 Resolved
Lighting in machinery spaces are without protective lenses.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 25 October 2006
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 20 January 2005 Resolved
Sewage treatment plant discharge pump suction piping is wasted and leaking. 33CFR159
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 January 2005
Resolved 25 October 2006
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 5 November 2003 Resolved
RENEW OR REPAIR THE FOLLOWING FUEL TANK VENTS DUE TO WASTED FLAME SCREENS OR WASTED HOUSINGS: #2 F/O TANK, FWD AND AFT. #3 F/O TANK, CENTER. #4 F/O TANK, PORTSIDE. #5 F/O TANK, STBD.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 January 2005
Resolution: Corrected satisfactory.
Pollution Prevention/Response › Prevention Equipment
Issued 5 November 2003 Resolved
PROVIDE SUFFICIENT QUANTITY OF CHLORINE TABLETS FOR SEWAGE TREATMENT SYSTEM. SHIP MUST PROVIDE PROOF OF PURCHASE PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2003
Resolution: Received fax copy of receipt for chlorine treatment tablets for MSD.
Fire Fighting › Fire Main › Condition
Issued 17 July 2001 Resolved
Fire Main piping has a soft patch in starboard passageway, on the main deck, near the valve. Make permanent repairs not later than 04Aug01.
Condition: Unknown
Due 4 August 2001
Resolved 20 January 2005
Resolution: Corrected satisfactory.
Navigation
Issued 30 June 1998 Resolved
BRITISH ADMIRALTY COAST PILOT #69 WAS MISSING SUPPLEMENT #10 WHICH IS NEEDED TO MAKE THE PUB CURRENT. CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 July 1998
Resolved 25 August 1998
Navigation
Issued 1 November 1990 Resolved
164.33: VESSEL DID NOT HAVE A CORRECTED COAST PILOT
Condition: Unknown
Due 1 November 1990
Resolved 1 November 1990
Navigation
Issued 1 November 1990 Resolved
164.33(a)(2)(ii): VESSEL DID NOT HAVE COAST LIGHT LIST ONBOARD.
Condition: Unknown
Due 1 November 1990
Resolved 1 November 1990
Navigation
Issued 1 November 1990 Resolved
164.33(a)(1)(ii): VESSEL DID NOT HAVE MARINE CHARTS WHICH WERE CURRENTLY CORRECTED.
Condition: Unknown
Due 1 November 1990
Resolved 1 November 1990

Ownership record