Records from 1988 to 1998. Most recent: inspection, 23 February 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
23 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412891
3 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 391253
10 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 378302
9 November 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 372401
4 November 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1172436
31 October 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 99736
3 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 369243
3 August 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1179781
1 November 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 362040
18 September 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 354686
11 December 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 521707
18 March 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 322263
Navigation
Issued 23 February 1998
Resolved
A discrepancy of 33 CFR 164.38(b) in that the vessel did not have an operable ARPA. Permanent repairs must be completed and tech report sent to MSO Philadelphia prior to departing.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Lifesaving
Issued 23 February 1998
Resolved
A deficiency of SOLAS 74 Reg III/27.2 in that the vessel did not have functioning light bulbs compatable with the lanterns located on all life jackets._x001C_ Correct prior to departure -- fax reciept for light bulbs.
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Fire Fighting
Issued 3 June 1996
Resolved
REPAIR EXHAUST LEAK ON EMERGENCY FIRE PUMP.
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Navigation
Issued 4 November 1994
Resolved
PROVIDE NTMS TO UPDATE CHARTS.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Navigation
Issued 4 November 1994
Resolved
PROVIDE NTMS TO UPDATE COAST PILOT.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Lifesaving
Issued 4 November 1994
Resolved
PROPERLY INSTALL WEAK LINKS TO LIFERAFTS.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Fire Fighting
Issued 4 November 1994
Resolved
MAKE TEMPORARY REPAIR TO HOLE IN FIREMAIN.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Navigation
Issued 3 August 1994
Resolved
LIGHT LIST VOL IV OR FOREIGN EQUIVALENT NOT CURRENTLY CORRECT.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Navigation
Issued 3 August 1994
Resolved
FAILED TO HAVE CURRENTLY CORRECTED COAST PILOT VOL. 5 OR FOREIGN EQUIVALENT
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Fire Fighting
Issued 3 August 1994
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN WHERE HOLED, TO SATISFACTION OF CLASS SOCIETY. SOLAS CH. II-2 REG 4.1
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Engineering
Issued 3 August 1994
Resolved
REPAIR EXHAUST SYSTEM ON EMERGENCY FIRE PUMP SO AS TO REDUCE THE AMOUNT OF SMOKE IN THE SPACE. SOLAS CH. II-2 REG 4, 3.3.2.8
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Navigation
Issued 3 August 1994
Resolved
VESSEL REQUIRED TO HAVE CHART 11370 OF THE AREA TO BE TRANSITED.
Condition: Unknown
Due 3 August 1994
Resolved 9 August 1994
Documentation
Issued 3 August 1994
Resolved
OIL RECORD BOOK WAS MISSING SIGNATURE OF PERSON IN CHARGE OF EACH TRANSFER OPERATION.
Condition: Unknown
Due 3 August 1994
Resolved 9 August 1994
Lifesaving
Issued 3 August 1994
Resolved
INSTALL WEAK LINK SYSTEM ON LIFE RAFTS. SOLAS CH. III REG 38 6.2.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Navigation
Issued 18 March 1988
Resolved
33CFR164.33(A)(2)(II) ADMIRALTY VOLUME J LIGHT LIST NOT CORRECTED.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Navigation
Issued 18 March 1988
Resolved
33CFR164.41 NO ELECTRONIC POSITION FIXING DEVICE INSTALLED.
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Documentation
Issued 18 March 1988
Resolved
33CFR155.45 VESSEL DID NOT HAVE POLLUTION PLACARD POSTED IN ENGINE ROOM.
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Documentation
Issued 18 March 1988
Resolved
33CFR155.75 INCOMPLETE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Documentation
Issued 18 March 1988
Resolved
33CFR155.820(A) MASTER COULD NOT PRODUCE A WRITTEN RECORD DESIGNATING A PERSON IN CHARGE OF OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Navigation
Issued 18 March 1988
Resolved
33CFR164.33(A)(1)(II) CHARTS 11324, 11327, 11328 AND 11329 NOT ON BOARD.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994