KAHANUOLA

KAHANUOLA is a 1988 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1988, most recently in September 2025, along with 106 deficiencies and 2 casualty investigations between 2018 and 2023.

Records from 1988 to 2025. Most recent: inspection, 22 September 2025.

Built
1988
Last inspected
22 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL2792
299966
Flag
UNITED STATES
367390730
Maury page id
psix-299966

Inspections, by type

…with no type recorded8
Years with a record 35 calendar years (1988–2025)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.0 ft × 11.0 ft × 5.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIGHTNING FIBERGLASS · KILAUEA, HI, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL2792MMSI 367390730 · active · compulsorily equipped · granted 5 October 2019, expires 5 October 2029
WDE7234MMSI 367390730 · expired · compulsorily equipped · granted 14 January 2009, cancelled 16 March 2019
WCY6819MMSI not assigned · expired · compulsorily equipped · granted 4 September 1998, cancelled 8 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

22 September 2025 Drydock Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8239356
10 July 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7946819
26 May 2023 Annual Inspection · Damage Survey · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7696900
26 May 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7758335
20 October 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7585128
5 October 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7343529
28 July 2021 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7270872
17 November 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7094988
30 October 2019 Annual Inspection · Deficiency Check · Drydock Exam · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6842264
31 October 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6570804
24 May 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6423984
6 December 2017 Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6316587
26 October 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6295252
3 January 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6065449
12 September 2016 Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5995649
6 May 2016 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5884831
13 October 2015 Hull Examination · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5792595
10 August 2011 Internal Structural Exam · Simplified Stability Test · COI Inspection · DAPI Audit · Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4111841
21 December 2010 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3914589
29 October 2010 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3881101
28 January 2009 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3413067
11 December 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3378246
28 September 2007 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3067832
15 September 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2781509
29 September 2005 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2603294
9 November 2004 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2221133
15 October 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1929287
2 October 2003 Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1922677
30 September 2003 Deficiency Check · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1917956
25 September 2002 Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1686064
12 August 2002 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1660595
17 October 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1074147
28 September 2001 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366595
30 August 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406790
16 February 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372934
18 August 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1402950
23 October 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1131650
21 August 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1390820
6 February 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1408046
3 April 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1095219
3 April 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1095802
13 February 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1422781
18 November 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1177871
31 August 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388116
20 August 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357709
30 July 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374695
16 April 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1404139
10 March 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 38958
30 October 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1417832
9 July 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 227126
13 April 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387742
8 February 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1449773
27 September 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1174754
8 September 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 697018
31 August 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1419303
1 February 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1463806
24 November 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1410874
20 April 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 841568
16 March 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 832347
1 March 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 165980
10 August 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 952364
22 June 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 232057
21 April 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1256810
30 March 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 948295
5 March 1991 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1303033
7 February 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1224169
2 October 1990 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1230631
20 February 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 927546
5 April 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1210436
25 January 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 892860
9 March 1988 Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1203166

Deficiency record · 106

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 May 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel sustained damage after running aground. Vessel rep must submit repair plan proposal approval and oversight of repair to OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2023
Resolved 30 June 2023
Resolution: Vessel rep submitted repair plan proposal for approval and oversight of repairs.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 May 2023 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel had expired alcohol test swabs onboard. Vessel rep must acquire sufficient alcohol test swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 29 June 2023
Resolution: Vessel rep provided alcohol test swabs to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 October 2019 Resolved
Prove proper operation of fixed gas fire system.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2019
Resolved 4 November 2019
Resolution: Witnessed proper operation of fixed gas fire system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 October 2019 Resolved
Provide bilge visual and audible indicators at helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 4 November 2019
Resolution: Provide bilge visual and audible indicators at helm.
Construction/Loadline › Hull › Hull Plating
Issued 12 September 2011 Resolved
Make raw water thru hull valves and exterior hull below the waterline available for inspection prior to receiving credit for drydock.
Due 30 September 2011
Resolved 26 September 2011
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 12 September 2011 Resolved
Provide proof of current CPR/first aid certification for 50% of crew.
Due 30 September 2011
Resolved 5 October 2011
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 12 September 2011 Resolved
Renew and prove operation of starboard engine vent closure pull cable.
Due 30 September 2011
Resolved 5 October 2011
Engineering › Bilge Water Management System › Pump
Issued 23 November 2010 Resolved
Prove operation of forward bilge pump.
Due 23 December 2010
Resolved 21 December 2010
Resolution: Forward bilge pump was operating satisfactorily.
Engineering › Fuel Oil Service System › Valve
Issued 23 November 2010 Resolved
Renew/prove operation of starboard emergency fuel shut off valve IAW 46CFR182.455.
Due 23 December 2010
Resolved 21 December 2010
Resolution: Starboard emergency fuel shut off valve was operating satisfactorily.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 November 2010 Resolved
Provide alchol testing devices onboard for the maximum number of crew IAW 46CFR4.06.
Due 23 December 2010
Resolved 21 December 2010
Resolution: Sufficient number of alcohol testing devices was purchased.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 November 2010 Resolved
Replace expired first aid kit items IAW 46CFR184.710.
Due 23 December 2010
Resolved 21 December 2010
Resolution: Expired first aid items were replaced.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 November 2010 Resolved
Provide and appropriately mark child lifejacket stowage separated from adult lifejacket stowage IAW 46CFR180.78.
Due 23 December 2010
Resolved 21 December 2010
Resolution: Child life jackets were stowed in a seperate & marked storage bag.
Documentation › Certificates/Documents › FCC SSL
Issued 11 December 2008 Resolved
Provide valid FCC Station License. Application pending transfer of ownership.
Due 25 December 2008
Resolved 28 January 2009
Lifesaving › Lifebuoys › Serviceable
Issued 11 December 2008 Resolved
Replace grab line on ring life buoy.
Due 25 December 2008
Resolved 28 January 2009
Fire Fighting › Fire Bucket › Quantity
Issued 11 December 2008 Resolved
Provide (2) additional fire buckets w/ "FIRE BUCKET" labeling and 6' lanyard.
Due 25 December 2008
Resolved 28 January 2009
Engineering › Fuel Oil Service System › Valve
Issued 11 December 2008 Resolved
Adjust stbd fuel shut-off valve and prove operation.
Due 25 December 2008
Resolved 28 January 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 September 2007 Resolved
Provide servicing report for portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 28 September 2007 Resolved
Provide servicing report for fixed FE-241 system to include testing of engine shut-downs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 September 2007 Resolved
Replace ring buoy grab line.
Due 12 October 2007
Resolved 17 October 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 September 2007 Resolved
Replace line on float light.
Due 12 October 2007
Resolved 17 October 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 September 2007 Resolved
Replace battery in EPIRB (expired AUG07).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 September 2005 Resolved
Splice 60 ft lifeline to lifering
Due 29 October 2005
Resolved 28 October 2005
Documentation › Markings/Placards › Warning Signs
Issued 29 September 2005 Resolved
Label emergency broadcast placard
Due 29 October 2005
Resolved 28 October 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 September 2005 Resolved
Prove proper operation of port running light and mast light
Due 29 October 2005
Resolved 28 October 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 29 September 2005 Resolved
Prove servicing for portable and fixed firefighting
Due 29 October 2005
Resolved 28 October 2005
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 September 2005 Resolved
Make drug and alcohol program available for inspection
Due 29 October 2005
Resolved 28 October 2005
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 29 September 2005 Resolved
Install retroreflective tape on lifejackets as discussed
Due 29 October 2005
Resolved 28 October 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 9 November 2004 Resolved
Provide valid copy of FCC safety certificate.
Due 9 December 2004
Resolved 5 January 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 9 November 2004 Resolved
Install new shaft packing on port shaft.
Due 9 December 2004
Resolved 5 January 2005
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 November 2004 Resolved
Install new retroreflective tape on lifejackets
Due 9 December 2004
Resolved 5 January 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 November 2004 Resolved
Separate child lifejackets from adult lifejackets
Due 9 December 2004
Resolved 5 January 2005
Accommodation/Occupational Safety › Ventilation
Issued 2 October 2003 Resolved
Provide closure devices for the port & stbd aft engine room vents and repair the closure devices for the port & stbd forward vents.
Action required: 705 - Other - as specified
Due 2 November 2003
Resolved 6 November 2003
Communications › Alarms/Indicators
Issued 2 October 2003 Resolved
Provide high water alarm for the forward compartment. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 2 November 2003
Resolved 6 November 2003
Resolution: The vessel''s MSD thru-hull was located in the engine room not the forward compartment. Cleared requirement with out installing the high water alarm.
Engineering › Shafting/Propeller Arrangements
Issued 30 September 2003 Resolved
Replace the stbd strut cutlass bearing. LEGACY COMPONENT DESC: Bearing
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 2 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 October 2002 Resolved
Conduct a static weight test of the lifting arm. The test shall be completed using 125% of the safe working load. Upon completion, the safe working load shall be placed on the lifting arm.
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 12 November 2002
Navigation › Collision/Grounding Avoidance
Issued 1 October 2002 Resolved
Install dive lights per navigation rules. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 12 November 2002
Construction/Loadline › Structures
Issued 1 October 2002 Resolved
Repair the aft hatch so that it can be properly secured. LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 12 November 2002
Engineering › Fuel Oil Service System
Issued 1 October 2002 Resolved
Repair the port and stbd fuel securing valves. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 12 November 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 1 October 2002 Resolved
Repair the installed fire extinguisher alarm system. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 12 November 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 1 October 2002 Resolved
Repair the port oil psi gauge.
Action required: 705 - Other - as specified
Due 1 November 2002
Resolved 12 November 2002
Lifesaving
Issued 28 September 2001 Resolved
Install rails on the port & stbd side of vessel per the approved drawings.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 November 2001
Resolved 12 November 2002
Construction/Loadline
Issued 5 September 2001 Resolved
Provide documentation that the vessel meets the requirements of 46 CFR 171.150.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 12 November 2002
Lifesaving
Issued 5 September 2001 Resolved
Patch holes and tears in life float.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Fire Fighting
Issued 5 September 2001 Resolved
Replace fixed fire extinguishing discharge cables.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Documentation
Issued 5 September 2001 Resolved
Provide logs of all drills conducted aboard the vessel in accordance with 46 CFR 185.520.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Documentation
Issued 5 September 2001 Resolved
Provide documentation that the vessels drug and alcohol program has been audited with in the last year.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Engineering
Issued 5 September 2001 Resolved
Repair stbd F/O copper line and install CG approved F/O hose and fittings per 182.720.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Lifesaving
Issued 5 September 2001 Resolved
Update first aid kit per attached list.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 November 2001
Resolved 25 September 2002
Construction/Loadline
Issued 5 September 2001 Resolved
Renew all bilge pump flexible hoses and overboard drain lines with marine grade hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 November 2001
Resolved 25 September 2002
Documentation
Issued 21 August 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 September 1998
Resolved 16 October 1998
Documentation
Issued 21 August 1998 Resolved
Obtain copy of vessel Stability Letter.
Condition: Unknown
Due 21 September 1998
Resolved 16 October 1998
Documentation
Issued 21 August 1998 Resolved
Obtain Certificate of Documentation._x001C_
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 21 August 1998 Resolved
Properly install life float (float free arrangement) with appropriate size weak link.
Condition: Unknown
Due 21 September 1998
Resolved 16 October 1998
Engineering
Issued 6 February 1998 Resolved
Replace port and starboard cutlass bearings._x001C_ _x001C_ _x001C_ x
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Construction/Loadline
Issued 6 February 1998 Resolved
Replace port and starboard sea valves.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Lifesaving
Issued 13 February 1997 Resolved
Provide for 50 percent primary lifesaving. Replace 10-person buoyant apparatus with 12-person buoyant apparatus or provide two additonal life rings. Total persons on board reduced to 20 until compliance.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Engineering
Issued 13 February 1997 Resolved
Install labeling/placard for operation of two emergency fuel shutoffs in accordance with 46CFR185.608.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Engineering
Issued 13 February 1997 Resolved
Vessel prohibited from carrying passengers until completion of Certificate of Inspection as deemed satisfactory by the attending CG marine inspector.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Lifesaving
Issued 13 February 1997 Resolved
Provide auto release 406 EPIRB or submit letter for reduction in route to no more than three miles from shore.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Documentation
Issued 13 February 1997 Resolved
Provide original stability letter.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Engineering
Issued 13 February 1997 Resolved
Repair oil pressure gauge (install sending unit) for starboard MDE.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Construction/Loadline
Issued 30 July 1996 Resolved
PROPERLY PLUG OFF AT THE THRU HULL FITTING OR CONNECT TO AN ELECTRIC BILGE PUMP THE PORT AND STBD AFT OVERBOARD BILGE HOSES TO THE SATISFACTION OF A USCG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 30 July 1996 Resolved
PROVIDE DIVE LIGHTS IAW REGULATION 27 OF THE NAVIGATION RULES PRIOR TO CONDUCTING NIGHT DIVE OPERATIONS.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 30 July 1996 Resolved
PROVIDE CODE ALPHA DIVE FLAG IAW REGULATION 27 OF THE NAVIGATION RULES FOR DAY LIGHT DIVING.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Fire Fighting
Issued 30 July 1996 Resolved
REPLACE EXTREMELY RUSTY FIRE EXINGUSHER BRACKETS TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Engineering
Issued 30 July 1996 Resolved
REPAIR WATER LEAK TO PORT ENGINE EXHAUST WATER COOLING EXCHANGER TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 30 July 1996 Resolved
PROVIDE PROPER DAY SHAPE FOR ANCHORING.
Condition: Unknown
Due 30 July 1996
Resolved 30 July 1996
Lifesaving
Issued 16 April 1996 Resolved
COMPLETE THE 10 ITEM CG-835 LIST FOR NEW "T"; ATTACHED TO 840 BOOK.
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996
Construction/Loadline
Issued 16 April 1996 Resolved
PROVIDE POSITIVE ACTION SHUT OF VALVE FOR THE ENGINE COMPARTMENT ELECTRIC BILGE PUMP AS CLOSE AS POSSIBLE TO THE HULL PENETRATION.
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996
Lifesaving
Issued 16 April 1996 Resolved
REPAIR AS PER ORIGNINAL BUOYANT APPARATUS; FABRIC LOOPS WORN/TORN THAT HOLDOUTER LIFE LINE. OPERATOR HAS NEW BA ON ORDER.
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996
Documentation
Issued 16 April 1996 Resolved
PROVIDE PROOF OF CHEMICAL TESTING PROGRAM TO THE USCG MARINE INSPECTION OFFICE PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Engineering
Issued 16 April 1996 Resolved
PROVE PROPER OPERATION OF THE STBD FUEL SHUT OFF VALVES PRIOR TO CARRYING PASSENGERS. TAPE UP SNAG AREA.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Fire Fighting
Issued 16 April 1996 Resolved
PROVE ANNUAL SERVICING OF 10LB HALON CYLINDER TO THE SATSIFACTION OF A USCGMARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Lifesaving
Issued 16 April 1996 Resolved
PROVIDE CAPTIVE CHAINS TO AFT AND FWD HATCHES.
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996
Lifesaving
Issued 16 April 1996 Resolved
WATER LIGHT TO BE ATTACHED TO BUOYANT APPARATUS WITH 18' LINE._x001C_
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996
Lifesaving
Issued 16 April 1996 Resolved
VESSEL NEEDS TWO EXTRA ADULT PFDs FOR A TOTAL OF 24 ADULT PFDs IN ORDER TO CARRY ITS MAX 24 PASSENGERS WITH ONE MASTER AND ONE DECKHAND. VESSEL RESTRICTED TO CARRING 20 PASSENGERS.
Condition: Unknown
Due 16 April 1996
Resolved 16 April 1996
Documentation
Issued 16 April 1996 Resolved
POST EMERGENCY CHECK OFF LIST NEAR PILOT STATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Fire Fighting
Issued 13 April 1995 Resolved
PROVIDE 10lbs OF EXTINGUISHING AGENT IN ONE BOTTLE OR DISTRIBUTED BETWEEN TWO BOTTLES THAT ARE CONNECTED TO DISCHARGE SIMULTANEOUSLY. PROVIDE PROPERFIRE PROTECTION/DETECTION MEANS IN ENGINE ROOM THAT MEET THE REQUIREMENTS OF NVIC 8-87 FOR NON-FIRE RETARDANT RESIN CONSTRUCTED VESSELS.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Lifesaving
Issued 8 February 1995 Resolved
RENEW/REPAIR LIFELINE ON BUOYANT APPARATUS.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Lifesaving
Issued 8 February 1995 Resolved
REPAIR/RENEW GRAB LINE ON RINGBUOY
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Construction/Loadline
Issued 8 February 1995 Resolved
RENEW/REPAIR KEEPER CHAINS ON ENGINE ROOM HATCH COVERS.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Fire Fighting
Issued 8 February 1995 Resolved
PROVIDE 10 lbs of extinguishing agent and proper fire protection/detection means in engine room meeting requirements of NVIC 8-87 for vessels constructed of non-fire retardant resin FRP.
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Documentation
Issued 31 August 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE EVIDENCE OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 31 August 1994
Resolved 1 September 1994
Construction/Loadline
Issued 31 August 1994 Resolved
PRIOR TO 30 SEPT 1994, SUBMIT FOR APPROVAL PLANS SHOWING THE BILGE PIPING SYSTEM, HULL PENETRATIONS, SHELL CONNECTIONS AND MATERIALS USED. INSTALLATION SHALL BE AT THE NEXT DRYDOCK BUT NO LATER THAN 30 NOVEMBER 1994.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Engineering
Issued 16 March 1993 Resolved
Make permanent repairs to stbd main deisel engine. Vessel is restricted to_x001C_1 nautical mile from shore and 5 nautical miles from port until compliance has been made to the satisfaction of [name withheld].
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Documentation
Issued 16 March 1993 Resolved
Post the vessel's stability letter on board the vessel.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Engineering
Issued 16 March 1993 Resolved
Properly stencil the locations of the remote fuel shut off valves.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Engineering
Issued 16 March 1993 Resolved
Stencil the direction in which the fuel shut off valves located in the engine room are closed or open.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Engineering
Issued 16 March 1993 Resolved
On the port and starboard diesel engines, permanently affix the springs located at the throttle cable.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Fire Fighting
Issued 16 March 1993 Resolved
Hook up the fixed halon bottle located in the aft part of the machinery space in parallel to the forward halon cylinder alarm.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 16 March 1993 Resolved
Renew the switch located on electrical power panel.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 16 March 1993 Resolved
Place a cover over the gauge on the electrical power panel.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 16 March 1993 Resolved
Properly attatch the ground wire located on the port diesel engine.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Electrical
Issued 16 March 1993 Resolved
Install guards on the turbochargers located on both diesel engines.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Fire Fighting
Issued 16 March 1993 Resolved
Fabricate covers for port and starboard vents to the engine room.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Engineering
Issued 16 March 1993 Resolved
Install 30x30 mesh flame screens on the port and starboard fuel tank vents.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Documentation
Issued 16 March 1993 Resolved
Post an emergency check off list on the vessel.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Lifesaving
Issued 16 March 1993 Resolved
In the presence of a USCG marine inspector, conduct underway drills with the required crew on board.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Lifesaving
Issued 16 March 1993 Resolved
Provide vessel with an audible signaling device
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Lifesaving
Issued 16 March 1993 Resolved
Seperate the child size pfd's from the adult size pfd's and label those areas with the number and size of PFD's stowed in that space.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Lifesaving
Issued 16 March 1993 Resolved
Stencil the ring bouy with the name of vessel.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Construction/Loadline
Issued 16 March 1993 Resolved
Free up the two watertight hatches for easy operation.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Lifesaving
Issued 30 March 1992 Resolved
INSTALL PENDANTS AROUND THE INSIDE AND OUTSIDE OF THE BUOYANT APPARATUS APPROXIMATELY 18 INCHES APART. EACH PENDANT MUST BE AT LEAST 1/4 INCH DIAMETER AND AT LEAST 12 FEET LONG SECURED IN THE MIDDLE TO THE BUOYANT APPARATUS.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Navigation
Issued 2 October 1990 Resolved
DOUBLE NUT OR DRILL AND PIN RUDDER THROUGH HULL BOLTS AND ALL STEERING GEARASSEMBLY AND BASE.
Condition: Unknown
Due 2 October 1990
Resolved 2 October 1990
Engineering
Issued 2 October 1990 Resolved
PROVIDE FUEL OIL SUPPLY/RETURN PIPING IN ACCORDANCE WITH 46 CFR 182.20-40. FLEXIBLE HOSE LENGTH MAY NOT EXCEED A REASONABLE LENGTH (NOT TO EXCEED 30 INCHES) AND ONLY FOR REASON OF FLEXIBILITY (IE. VIBRATION).
Condition: Unknown
Due 2 October 1990
Resolved 2 October 1990
Lifesaving
Issued 20 February 1990 Resolved
PROVIDE 2 MORE ADULT PFD,S TO BRING TOTAL TO 24. CERTIFICATE LIMITED TO 22ADULT PERSONS UNTIL 2 ADDITIONAL ABOARD.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990

Casualty record · 2

24 May 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6423984
26 May 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 5 injured · activity 7758335
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.