MAURY USCG vessel records
← All vessels

RIVER QUEEN

Built
1988
Last inspected
19 May 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

300180
Flag
UNITED STATES
Maury page id
psix-300180

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
1 - Simplified, Net Ton
0 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

19 May 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8382790
14 May 2025 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8139158
28 August 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7991235
25 April 2024 Hull Examination · Simplified Stability Test · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7905634
25 April 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7710726
8 June 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7478697
29 July 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7277177
31 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7021313
21 May 2019 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685809
21 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6719057
12 April 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6121343
18 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5849901

Deficiency record · 6

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2026 No resolution recorded
An enclosed space containing machinery powered by gasoline or other fuels having a flash point of 43.3 °C (110 °F) or lower must be equipped with a flammable vapor detection device in compliance with § 182.480. The flammable vapor detection device for the engine room was not functioning. Owner has ordered a replacement and will send a video of operation once installed.
Action required: 17 - Rectify deficiencies prior to departure
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 May 2025 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vsl was missing alcohol test equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2025
Resolved 22 May 2025
Resolution: Test strips placed on board.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 1 May 2017 Resolved
Install and prove proper operation of the fixed fire fighting system (FireBoy) in the engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2017
Resolved 1 June 2017
Resolution: Vessel owner provided picture and servicing report showing that the FireBoy extinguisher had been properly installed in the machinery space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2017 Resolved
Properly terminate dead-end wires in the engine compartment.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 June 2017
Resolution: Owner provided pictures showing that previously installed dead-end wires had been removed from the engine compartment.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 18 April 2016 Resolved
Annual service not conducted on FireBoy. Operator directed to have annual inspection conducted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 21 May 2019
Resolution: Servicing checked during activity 6685809, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2016 Resolved
PT-2: Items in the first aid kit expired. Operator instructed to replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 21 May 2019
Resolution: First Aid Kit checked during activity 6685809, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.