Professional
The full record for this vessel
Behind this panel: 12 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 12
19 May 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8382790
14 May 2025
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8139158
28 August 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7991235
25 April 2024
Hull Examination · Simplified Stability Test · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7905634
25 April 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7710726
8 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7478697
29 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7277177
31 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7021313
21 May 2019
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685809
21 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6719057
12 April 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6121343
18 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5849901
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2026
No resolution recorded
An enclosed space containing machinery powered by gasoline or other fuels having a flash point of 43.3 °C (110 °F) or lower must be equipped with a flammable vapor detection device in compliance with § 182.480. The flammable vapor detection device for the engine room was not functioning. Owner has ordered a replacement and will send a video of operation once installed.
Action required: 17 - Rectify deficiencies prior to departure
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 May 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vsl was missing alcohol test equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2025
Resolved 22 May 2025
Resolution: Test strips placed on board.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 1 May 2017
Resolved
Install and prove proper operation of the fixed fire fighting system (FireBoy) in the engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2017
Resolved 1 June 2017
Resolution: Vessel owner provided picture and servicing report showing that the FireBoy extinguisher had been properly installed in the machinery space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2017
Resolved
Properly terminate dead-end wires in the engine compartment.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 June 2017
Resolution: Owner provided pictures showing that previously installed dead-end wires had been removed from the engine compartment.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 18 April 2016
Resolved
Annual service not conducted on FireBoy. Operator directed to have annual inspection conducted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 21 May 2019
Resolution: Servicing checked during activity 6685809, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2016
Resolved
PT-2: Items in the first aid kit expired. Operator instructed to replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 21 May 2019
Resolution: First Aid Kit checked during activity 6685809, all sat.