MAURY USCG vessel records Sign in
← All vessels

BUENOS AIRES

BUENOS AIRES is a 1984 freight ship. The Coast Guard has recorded 36 inspections since 1988, most recently in July 2009, along with 35 deficiencies and 3 operational controls.

Records from 1988 to 2009. Most recent: inspection, 28 July 2009.

Built
1984
Last inspected
28 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC2952
300504
Flag
UNITED STATES
—
Maury page id
psix-300504

Inspections, by type

…with no type recorded18
Years with a record 15 calendar years (1988–2009)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10591 - Regulatory (Subpart C or D), Net Ton
29930 - Dead Weight, Ton
23790 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OEL PEACE Freight Ship · MISLE 287596 · 1 February 2007 · activity 2867613

Inspection history · 36

28 July 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3548350
3 January 2008 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3124249
4 June 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2951622
3 April 2007 Deficiency Check
Physical examination · Activities Europe · Activity 2900523
6 February 2007 Hull Examination
Physical examination · Activities Europe · Activity 2867609
1 February 2007 Type not recorded
No type recorded · Activities Europe · Activity 2867613
31 January 2007 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 2865797
26 October 2006 Damage Survey
Physical examination · Activities Europe · Activity 2808298
25 October 2006 Type not recorded
No type recorded · Activities Europe · Activity 2830452
10 April 2006 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2621144
16 February 2006 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2586323
1 February 2006 Annual Inspection
Physical examination · Activities Europe · Activity 2538860
14 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2566322
30 October 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2565702
16 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2464691
16 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2464059
23 June 2005 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2400117
21 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2339610
14 December 2004 MTSA/ISPS Verification · Reflagging & Initial Certification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2259380
10 December 2004 Reflagging & Initial Certification
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2276721
23 November 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2246901
19 October 2004 NPV Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2223628
10 July 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2128096
10 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2128235
5 February 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2004139
9 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1845706
13 June 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290979
30 November 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 435249
5 October 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433429
15 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 419313
16 October 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 371601
19 April 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 350144
18 December 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 452531
22 April 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 343261
20 May 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 330560
12 April 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 322582

Deficiency record · 35

Documentation › Markings/Placards › Warning Signs
Issued 31 January 2007 Resolved
Properly mark the evacuation route for the machinery spaces. Report cleared via E-mail 03 April 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 3 April 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 January 2007 Resolved
Show proof the OWS has been calibrated to 15 ppm. Report cleared via E-mail 03 April 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 3 April 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 January 2007 Resolved
Provide itemized servicing report for the fixed CO2 system. Report cleared via E-mail 03 April 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 3 April 2007
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 31 January 2007 Resolved
Provide copy of ISM Document of Compliance aboard the ship. Report cleared via E-mail 03 April 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 3 April 2007
Lifesaving › Lifeboat Equipment › Searchlight
Issued 31 January 2007 Resolved
Repair of replace the search light in the port side life boat. Report cleared via E-mail 03 April 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 3 April 2007
Lifesaving › Inflatable Liferafts › Float Free
Issued 31 January 2007 Resolved
Make the port and starboard side life rafts free from overhead obstructions. Report cleared via E-mail 03 April 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 3 April 2007
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 31 January 2007 Resolved
At next CG attendance items 1 and 2 identified in MSC Automation test procedure review letter dated 06-06-05, must be tested.
Condition: Unknown
Due 18 March 2008
Resolved 3 April 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 October 2006 Resolved
Demonstrate proper operation of the #3 generator to the satisfaction of the attending Marine Inspector or Lloyds Register surveyor.
Action required: 705 - Other - as specified
Due 28 November 2006
Resolved 15 November 2006
Resolution: See attached LR report and e-mails.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 October 2006 Resolved
Provide a detailed report explaining the cause of the failure to the #3 generator and actions taken to prevent re-occurrence. The report must be signed by the Master and Chief Engineer and reviewed by Lloyds Register prior to submission to the Coast Guard.
Action required: 705 - Other - as specified
Due 28 November 2006
Resolved 15 November 2006
Resolution: See attached LR report and e-mails.
Engineering › Steering Gear System › Feedback Unit
Issued 1 February 2006 Resolved
Repair stbd steering gear pump switch indicator on bridge. Switch has 15 second delay before light comes on and the steering failure alarm activates.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 1 February 2006 Resolved
Replace lifejacket lights on all lifejackes which do not work.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 1 February 2006 Resolved
Update lifeboat equipment.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2006 Resolved
Provide safety grating/guard around emergency exhaust.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 February 2006 Resolved
Replace hydro releases on liferafts with dated releases.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Accommodation/Occupational Safety › Ventilation › General
Issued 1 February 2006 Resolved
Repair and replace the #2 fan supply motor.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 1 February 2006 Resolved
Repair and replace all flame screens on deck.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Lifesaving › Immersion Suits › General
Issued 1 February 2006 Resolved
Conduct drill where the immersion suits are donned and logged.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 1 February 2006 Resolved
Replace the sprinkler pipe in the paint locker and outside paint locker.
Due 18 December 2006
Resolved 31 January 2007
Lifesaving › Launching Appliances › Davit
Issued 1 February 2006 Resolved
Port/stbd davit are extremely corroded; port davit has a 3 inch rust hole in the center of the davit bracket. Repair the arms to original condition. Provide documentation that the repairs are Coast Guard approved or to the class society satisfaction.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 1 February 2006 Resolved
Replace insulation on piping on Generators 1, 2, and 3 and the boiler.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Lifesaving › Lifeboat › Propulsion Engine
Issued 1 February 2006 Resolved
Replace o-ring in fuel filter on port side lifeboat.
Due 1 March 2006
Resolved 15 February 2006
Resolution: CG-835 deficiency status is cleared, Lloyd''s office in Dubai had made item a Class Recommendation.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 10 December 2004 Resolved
The vessel's SOPEP has not been approved. Provide a copy of the approval letter from Coast Guard Office of Response (G0MOR) to the Houston OCMI prior to 17JAN05.
Action required: 705 - Other - as specified
Due 17 January 2005
Resolved 31 January 2005
Resolution: Received approval letter from G-MOR dated 31JAN2005.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 December 2004 Resolved
Provide Fire Safety Plan corrected to reflect location of all fire axes, fire applicators, and newly designated fire station (prior deck wash hydrant) located forward portside tunnel, and ensure symbols indicated on the plan are IAW IMO Resolution A.654 (16), prior to 17JAN05.
Action required: 705 - Other - as specified
Due 17 January 2005
Resolved 15 April 2005
Resolution: Received class report from LR dated 15APR2005 regarding annual survey conducted for Safety Equipment Certificate.
Documentation › Certificates/Documents › Intact Stability Booklet
Issued 10 December 2004 Resolved
Vessel may operate within the parameters of the existing Lloyd's Register approved Trim & Stability Book until final Deadweight Survey is incorporated into the new approved Trim & Stability Book.
Action required: 705 - Other - as specified
Due 10 March 2005
Resolved 11 February 2005
Resolution: Received approval letter from class indicating approval of Trim & Stability book incorporating loading condition No. 10 satisfying the Intact and Damage Stability requirements as indicated.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 10 December 2004 Resolved
Provide proposed maintenance schedule for 24-inch sea chest valves to ensure proper seals are maintained prior to 17JAN05. If valve approval isn't granted subsequently by Coast Guard Marine Safety Center (MSC) for installed valves, they are to be replaced at next dry-docking IAW Memoranda issued by LR.
Action required: 705 - Other - as specified
Due 17 January 2005
Resolved 14 January 2005
Resolution: Received maintenance schedule from Chief Engineer regarding 24" sea chest valves.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 10 December 2004 Resolved
Vessel granted an extension of 90 days (IAW LR Condition of Class) to modify both port/starboard lifeboats to demonstrate proper on-load release capability as indicated in approval letter dated 18JUL99 from Head of the Netherlands Shipping Inspection. Therefore, due date is 180 days after date imposed.
Action required: 705 - Other - as specified
Due 10 September 2005
Resolved 18 November 2005
Resolution: Corrected per [name withheld], class society liason.
Lifesaving › Lifeboat › Propulsion Engine
Issued 10 December 2004 Resolved
Vessel to lower port lifeboat, release and run in the water no later than 17JAN05. Provide video demonstrating this to Coast Guard Marine Safety Office (MSO) Houston if vessel does not return to Houston by specified date.
Action required: 705 - Other - as specified
Due 17 January 2005
Resolved 3 March 2005
Resolution: Received copy of logbook excerpt indicating port lifeboat was lowered, released, and run in the water.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 10 December 2004 Resolved
Demonstrate proper lowering of port-side lifeboat utilizing brake release via wire from inside lifeboat no later than 17JAN05. Provide video demonstrating this to Coast Guard MSO Houston if vessel does not return to Houston by specified date.
Action required: 705 - Other - as specified
Due 17 January 2005
Resolved 3 March 2005
Resolution: Received copy of vessel logbook indicating port lifeboat was lowered using wire from inside lifeboat.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 10 December 2004 Resolved
Provide approved Periodic Automation Test Procedures from CG MSC prior to 17FEB05.
Action required: 705 - Other - as specified
Due 17 February 2005
Resolved 18 November 2005
Resolution: Corrected per [name withheld], class society liason.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 10 December 2004 Resolved
LR to provide Condition of Class (if needed), to address Structural Fire Protection regarding cable penetration firestop & A-60 deck underlayment insulation (which were not CG MSC approved) prior to 17FEB05. Class must explain reasoning if determination is given indicating that they believe the SFP IWO these areas is equivalent.
Action required: 705 - Other - as specified
Due 17 February 2005
Resolved 7 February 2005
Resolution: Received class reported finding A-60 deck underlayment acceptable.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 December 2004 Resolved
Submit "As Is" plan to MSC indicating actual locations of CO2 actuated alarms in machinery spaces prior to 17JAN05.
Action required: 705 - Other - as specified
Due 17 January 2005
Resolved 31 May 2005
Resolution: Vessel submitted LR approved plan to MSC.
Lifesaving › Lifeboat › Markings
Issued 10 December 2004 Resolved
Plaques on lifeboats indicating "A" and "B" weights and davits indicating Maximum Safe Working Load, to be stamped by CG Marine Inspector prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2004
Resolved 18 December 2004
Resolution: Plaques provided and placed on lifeboats and davits.
Fire Fighting › Fire Main › Valves
Issued 10 December 2004 Resolved
Provide weathertight caps for all deck wash hydrants on weatherdeck prior to 01JAN05.
Action required: 705 - Other - as specified
Due 1 January 2005
Resolved 13 January 2005
Resolution: Received letter from owner indicating weathertight caps for all deck wash hydrants had been installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 December 2004 Resolved
Provide report from FPS indicating factory test of all soft hoses and pressure fittings tested to 6000 psi prior to 1JAN05.
Action required: 705 - Other - as specified
Due 1 January 2005
Resolved 13 January 2005
Resolution: Received report from Fire [name withheld] indicating soft hoses and pressure fittings passed a test when pressed to 6000 psi, report was dated 4DEC2005.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 July 2004 Resolved
Vessel granted inbound deviation due to inoperable primary marine radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2004
Resolution: Received technicians report attesting to satisfactory repairs to primary marine radar.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.