Records from 2016 to 2026. Most recent: inspection, 6 January 2026.
Inspection history · 20
6 January 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8289147
18 August 2025
Type not recorded
No type recorded · Station Cape May · USCG East District (CGD-E) · Activity 8212125
20 May 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8139610
29 January 2025
Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8067106
8 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8032374
22 May 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7917408
12 October 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7806515
19 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7580254
12 May 2022
COI Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7437551
4 May 2022
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7443702
1 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7166854
31 August 2020
Type not recorded
No type recorded · Station New London · USCG Northeast District (CGD-NE) · Activity 7047780
16 July 2020
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6906044
10 March 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6906043
8 July 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6681223
23 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6363348
15 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6363346
27 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6131582
19 May 2016
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5880942
21 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5837651
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 January 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must be in compliance with § 181.420 of this part. The pre-engineered fire extinguishing system failed to shut down the main engines. Have the system serviced by an approved service technician.
46 CFR 181.400(b)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 January 2026
Resolved
A vsl must be provided w/bilge pumps in accordance w/ Table 182.520(a). The vsl’s primary mechanical pump was inoperable, in add’n to the submersible pump in cabin. Repair/replace the mechanical pump & submersible pump to the satisfaction of a marine inspector.
46 CFR 181.400(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 January 2026
Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessels IBA was send ashore for service at time of inspection. Provide a copy of the service report & reinstall the IBA.
46 CFR 180.202(a)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 January 2026
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines. Starboard valve was stuck open. Replace valve.
46 CFR 182.20-40(b)(3) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 January 2025
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Rescue platform was inadequate for intended use. Replace with adequate rescue platform.
46 CFR 185.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Replaced with new rescue platform. Inspected satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 29 January 2025
Resolved
Rails on passenger decks of a ferry or a vessel engaged in excursion trips, including but not limited to sightseeing trips, dinner and party cruises, and overnight cruises, must be at least 1,000 millimeters (39.5 inches) high. Rails on vessel are under 39.5 inches. Install new railing on aft deck to 39.5 inches.
46 CFR 177.900(d)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Inspected new 40-inch railing. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2025
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Affix vessel name to port and starboard bow and stern. Affix hailing port to vessel stern.
46 CFR 67.123(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Vessel name and hailing port were properly affixed to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 January 2025
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS.” Watertight container not properly stenciled.
46 CFR 185.614
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Distress signals were properly stenciled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff markings were diminished and unreadable.
46 CFR 185.608
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Fuel shut-offs were properly marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 January 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Bonding strap forward and outboard of port side main propulsion engine affixed to the hull was corroded and had discontinuity.
46 CFR 183.01-15
(Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2025
Resolution: Bonding terminal was made continuous.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2023
Resolved
Vessel had a waterlight of the wrong type. Required to be self actuating. This one was not.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 November 2023
Resolved 12 October 2023
Resolution: Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 12 October 2023
Resolved
Vessel did not have correct number or correct type of flares on board.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2023
Resolved 13 October 2023
Resolution: Puchased.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 October 2023
Resolved
Vessel did not have an adequate first aid kit on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2023
Resolved 16 November 2023
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 12 October 2023
Resolved
Vessel had not installed interconnected smoke detectors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2023
Resolved 16 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 12 October 2023
Resolved
Vessel did not have alcohol testing strips on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2023
Resolved 16 November 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 October 2023
Resolved
Vessel did not have an adequate means for recovering a MOB.
Extended time until May 2024 to coincide with vessels drydock. Vsl does not have any more trips for the season.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2023
Resolved 22 May 2024
Resolution: Ladder on board.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 October 2023
Resolved
Vessel had not logged drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2023
Resolved 16 November 2023
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 12 October 2023
Resolved
Vessel had not been logging monthly required EPIRB checks,
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2023
Resolved 16 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 October 2023
Resolved
Vessel did not have updated charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2023
Resolved 16 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2022
Resolved
Vessel may not operate more than three miles from shore and no more than twenty miles from a harbor of safe refuge until an IBA is installed onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 19 October 2022
Resolution: Owner provided proof of IBA installed onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2020
Resolved
Restrict passengers to 13 max (1 master, 1 deckhand, and 13 passengers) on routes greater than 20 nm from shore and greater than 3 NM from shore in cold waters as defined by NVIC 7-91. 15 person life float is installed while inflatable buoyant apparatus is being serviced.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 30 September 2020
Resolution: Vessel's IBA service record was scanned and sent. Inspected IBA for proper configuration.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2020
Resolved
Reconfigure vessel's survival craft to allow for float free operation. Life float was found strapped down using bungee cords to secure the raft to the vessel's overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 20 August 2020
Resolution: Bungee cord retaining the life float was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 July 2020
Resolved
Create and maintain a life saving log to include maintenance and inspection of life saving equipment and EPIRB.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 30 September 2020
Resolution: Log established.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2020
Resolved
Provide 1 40 B:C portable fire extinguisher in accordance with COI. Vessel was equipped with 3 10 B:C/ 2-A portable fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 30 September 2020
Resolution: 10B:C fire extinguisher provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2019
Resolved
Provide 09 adult life jackets with lights. Vessel restricted to 19 persons until provided. 46CFR180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 30 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2019
Resolved
Provide lights on 04 adult PFDs and 01 childrens PFDs that were not equipt with them. 46CFR180.75(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 30 July 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 July 2019
Resolved
Replace hydrostatic release on EPIRB. Vessel restricted from operating outside of 3 miles from shore. 46CFR180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 30 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019
Resolved
Clean fuel filters. 46CFR182.455(b)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 30 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2019
Resolved
Provide corrosion resistant nozzle for fire hose. 46CFR181.320(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 10 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2019
Resolved
Replace fuel system piping with hard piping. Flex hose may not exceed 30"
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 10 March 2020