Records from 1988 to 2017. Most recent: inspection, 21 April 2017.
Inspection history · 78
21 April 2017
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6129340
1 December 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6048628
25 November 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6047394
19 October 2015
Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5745878
13 March 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4812694
13 March 2014
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4812729
18 February 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4244906
5 August 2011
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4100737
19 July 2011
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4086998
4 February 2011
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3939305
14 January 2011
ISPS III Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3924811
30 December 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3386434
23 December 2008
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3379057
23 December 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3386399
28 October 2008
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3353045
21 May 2008
Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3212591
13 May 2008
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3205291
14 March 2008
ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3162260
25 May 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2658665
4 May 2006
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2640671
13 February 2006
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2584085
11 April 2005
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2330896
7 April 2005
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2328206
5 February 2005
ISPS III Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2287208
2 December 2004
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2251836
10 September 2004
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2192057
17 July 2004
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2136253
14 July 2004
ISPS II Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2133272
11 May 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2064742
7 April 2004
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2039389
6 April 2004
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2038628
3 March 2004
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2017630
12 August 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1874097
20 June 2003
Security Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1822171
14 March 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1757267
24 January 2003
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1734781
6 October 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1683363
30 April 2002
Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1613859
29 April 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1608850
22 February 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1488533
3 December 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295881
30 November 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 295848
27 June 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 291360
16 March 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 288136
27 April 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 277911
22 April 2000
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 276862
25 September 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 433159
17 May 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 428601
13 March 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 413598
17 November 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 409624
18 July 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 405942
29 January 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 527286
26 January 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 96199
5 September 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 394930
18 June 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 108662
18 June 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 166007
12 June 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 379253
13 April 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 377168
7 October 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 371556
5 October 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 370954
19 July 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 656057
15 July 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 368656
11 July 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 667146
10 July 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 368365
14 March 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 508198
23 July 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 359826
16 December 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 532342
11 June 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 351307
9 June 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 501679
16 December 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 526266
9 May 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 343654
11 November 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 538370
1 May 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 336829
5 October 1989
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 468444
14 March 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 514133
10 March 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 328979
12 September 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 520390
13 April 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 322583
Construction/Loadline › Markings › Load Line Mark
Issued 9 March 2014
Resolved
The rings, lines, and letter shall be painted in white or yellow on a dark ground or in balck on a white ground. Vessel's loadline is the same color as the ships hull and should be painted white.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 March 2014
Resolution: Vessel painted loadline and sent photos to USCG
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 19 July 2011
Resolved
Insufficient or missing insulation on main propulsion engine aft turbo charger bellows connection to manifold. Damaged or burned insulation on main propulsion engine forward turbo charger bellows connection to exhaust manifold. Burned insulation on main propulsion engine exhaust manifold center bellows connection. 2009 (CONS) I-11 (a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 August 2011
Resolved 5 August 2011
Resolution: Vessel was attended and the repair made to the insufficient insulation on the turbo charger and main engine exhaust were rectified to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 14 January 2011
Resolved
Every ship shall be provided with fire pumps that comply with the applicable requirements of this regulation. Emergency fire pump had pin hole leak in water outlet pipe on emergency fire pump. SOLAS 74 (97 cons.) II-2/ 4.1 (50a/b)
Action required: 705 - Other - as specified
Due 14 February 2011
Resolved 4 February 2011
Resolution: Received NKK class report attesting to repairs.
Fire Fighting › Fire Pumps › Suction Valve
Issued 23 December 2008
Resolved
During the test of the emergency fire pump, an oil sheen was observed on the water surface. Further investigation revealed what appeared to be fuel oil coming out of port fire main deck hydrant. This poses a fire risk to the vessel. 17a/c 0700
SOLAS 2004 Ch.I/11
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2008
Resolution: Received Class report stating the fire main had been flushed with no further sheen. It is thought that the oil got into the fire line from the emergency suction in the engine room. A caution plate is to be installed on the valve. Deficiency cleared.
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 December 2008
Resolved
Crew unable to start the STBD life boat due to extreme cold weather. 17a/c 0610
SOLAS 92 CHIII/26.1.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2008
Resolution: Received Class report stating the starboard side lifeboat engine was repaired and started to the satisfaction of the attending surveyor. Deficiency cleared.
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 December 2008
Resolved
Unable to start the emergency generator on the #2 battery bank. Batteries appear to be dead due to cold weather. 17a/c 1400 SOLAS 2004 CH II-1/43.3.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2008
Resolution: Received Class report stating the batteries of the #2 bank with a successful start to the satisfaction of the attending surveyor. Deficiency cleared.
Fire Fighting › Fire Main › Condition
Issued 23 December 2008
Resolved
There is a break in the fire main on the 01 deck, mid ship port side. 40a 0700
SOLAS 2004 CH.1/11
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 24 December 2008
Resolution: Received Class report stating the break had been temporarily repaired and is to be permanently repaired by Jan 23rd, 2009. Deficiency cleared.
Engineering › Lubricating Oil Storage/Transfer System › Flange
Issued 21 May 2008
Resolved
Excessive lube oil observed underneath main engine lube oil settling tank. Vessel's crew had replaced gasket on lube oil return line flange which had been leaking. Oil underneath the tank was not properly cleaned up.
Condition: Improper/Lack of Maintenance
Due 21 May 2008
Resolved 21 May 2008
Resolution: Vessel''''''''''''''''''''''''''''''''s crew cleaned underneath the main engine lube oil settling tank prior to departure of USCG inspection team.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 14 March 2008
Resolved
Emergency fire pump is unable tro supply sufficient water to two hoses on the top deck creating undue risk to the ship and crew in the event of fire. 30a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2016
Resolution: Received a Flag State waver allowing the vessel to operate with the malfunctioning fire pump due to the unavailability of parts in the U.S. The vessel will provide a roving fire patrol and repairs must be completed on the vessels next call to Japan.
Fire Fighting › Fire Hydrants › Condition
Issued 14 March 2008
Resolved
Foward port station on accomodation deck is not able to discharge fire fighting water causing undue risk to the ship and crew in the event of fire. 30a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2008
Resolution: FIRE STATION WAS CLEANED OUT, TESTED AND FOUND SATISFACTORY BY CLASS
Lifesaving › Rescue Boat › Propulsion Engine
Issued 14 March 2008
Resolved
Ships rescue boat (STBD side) did not start and is not ready for immediate use causing undue risk to the crew if abandoning ship is necessary. Crew worked for over 30 minutes to start the rescue boat with no success. 30a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2008
Resolution: STBD SIDE LIFEBOAT WAS REPAIRED, TESTED AND FOUND SATISFACTORY BY CLASS
Engineering › Steering Gear System › Power Unit
Issued 14 March 2008
Resolved
Steering gear hydraulic oil tank does not contain sufficient hydraulic oil to recharge one power actuating system and resevoir causing undue risk to ship and crew. 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2008
Resolution: HYDRAULIC OIL TANK FILLED UP TO SUFFICIENT LEVEL AND FOUND SATISFACTORY BY CLASS
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 14 March 2008
Resolved
Incineratior unable to immediately start. Required crew to make temporary repair to wires to ignitor in order to operate. 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2008
Resolution: INCENERATOR WAS REPAIRED, TESTED AND FOUND SATISFACTORY BY CLASS
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 14 March 2008
Resolved
Received a Flag State waver allowing the vessel to operate with the malfunctioning fire pump due to the unavailability of parts in the U.S. The vessel will provide a roving fire patrol and repairs must be completed on the vessels next call to Japan and no later than 30APR2008. 70a.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 April 2008
Resolved 13 May 2008
Resolution: On 13 May 2008 visit the M/V Queen Ace at pier 15 San Juan, to do a Def-Check follow up for a deficiencies issue at Sector Seattle on 14 March 2008. Captain provide a class report attesting the repairs, also witness a operational test of fire pump.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 April 2005
Resolved
Lights missing cover in workshop area near engine control room. New cover put in place.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Resolution: Placed new cover on light.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 7 April 2005
Resolved
Heating light placed in CO2 Room for pipe.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Resolution: Removed heating light from CO2 Room.
Lifesaving › Launching Appliances › Falls
Issued 7 April 2005
Resolved
Limit switch and or electric retrieving device not working. Prove to satisfaction of Class, that limit switch and or electric retrieving device on Port lifeboat is working properly prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 11 April 2005
Resolution: Rcv''d Class Report (NKK) dated 07Apr05. Permanent repairs were made to davit winch. Winch and limit switch tested and in working order.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 September 2004
Resolved
SEAWATER COOLING PIPING FOR CO2 COMPRESSOR MOTOR HAS A SOFT PATCH OVER HOLE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 December 2004
Resolution: RECIEVED FAX FROM NKK, VESSELS CLASS SOCIETY THAT THE DEFICIENCY HAS BEEN CORRECTED TO THE SATISFACTION OF THE ATTENDING CLASS SOCIETY.
Engineering › Lubricating Oil Service System › Cooler
Issued 10 September 2004
Resolved
FOWARD END CAP OF MAIN ENGINE LUBE OIL COOLER HAS A SOFT PATCH.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 December 2004
Resolution: RECIEVED FAX FROM NKK, VESSEL CLASS SOCIETY STATING THIS DEFICIENCY HAS BEEN CORRECTED TO THE SATISFACTION OF THE CLASS SURVEYOR.
Engineering › Lubricating Oil Service System › Cooler
Issued 10 September 2004
Resolved
INLET AND OULET PIPES TO MAIN ENGINE LUBE OIL COOLER HAS TWO SOFT PATCHES, ONE LEAKING GASKET, AND A DOUBLER.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 5 February 2005
Resolution: Observed inlet and outlet pipes to main engine lube oil cooler were replaced, gaskets replaced. All Sat
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 September 2004
Resolved
MAIN ENGINE SALT WATER BY-PASS OVERBOARD PIPE BEFORE 3-WAY VALVE HAS A TEMPORARY REPAIR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 5 February 2005
Resolution: Observed by-pass overboard pipe for main engine salt water cooling before 3-way valve was replaced and in proper repairs in the satisfaction of class society.
Fire Fighting › Structural - A Class Divisions
Issued 12 August 2003
Resolved
5 "A" class fire doors are not self-closing.
1) Fire Door to escape trunk in aft steering. 2) Foward access to steering room 3-4) Port and Starboard escape trunks
5) Starboard access to escape trunk to bunker station on car deck #9 LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 11 September 2003
Resolved 7 April 2004
Resolution: REPAIRED TO THE SATISFACTION OF THE COAST GUARD BOARDING OFFICER.
Engineering › Diesel Engine (auxiliary)
Issued 24 January 2003
Resolved
#2 + #3 SHIP DIESEL GENERATORS INTERCOOLER BYPASS VALVE WASTED. REPAIR / REPLACE TO THE SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2003
Resolved 22 February 2003
Resolution: CLASS ATTESTED TO PERMANENT REPAIRS.
Pollution Prevention/Response › Prevention Equipment
Issued 24 January 2003
Resolved
SEWAGE TANK VENT HOLED AND WASTED. REPAIR TO THE SATISFACTION OF CLASS SOCIETY. LEGACY COMPONENT DESC: Sewage System Tank
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2003
Resolved 22 February 2003
Resolution: CLASS ATTESTED TO PERMANENT REPAIRS.
Navigation › Piloting/Steering
Issued 24 January 2003
Resolved
PROVIDE CURRENT COPY OF SAILING DIRECTION PUB OR FOREIGN EQUIVALENT, PRIOR TO DEPARTUR COPT BALTIMORE. LEGACY COMPONENT DESC: US Coast Pilot
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2003
Resolved 24 January 2003
Resolution: COPY OF RECIPT
Lifesaving › Immersion Suits
Issued 6 October 2002
Resolved
Repair all immersion suits (glove areas) to satisfaction of classification society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 24 January 2003
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPLACEMENT OF IMMERSION SUITS.
Construction/Loadline
Issued 30 November 2001
Resolved
REPLACE GASKET AND GREASE DOGS ON DOOR TO LOW PRESSURE CO2 ROOM. ICLL 66 ANNEX 1/15.
Condition: Unknown
Due 30 December 2001
Resolved 22 February 2002
Resolution: Conducted Port State Control II deficiency follow-up with 01cleared (activity #295848) 00 issued, 00 remain outstanding.
Fire Fighting
Issued 22 April 2000
Resolved
Two fire hose stations below the port bridge wing had no water pressure during fire fighting drill. Both stations need to be cleaned of debris, andserviceable before returning to the United States from a foreign port.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Lifesaving
Issued 17 May 1999
Resolved
PROVE PROPER OPPERATION OF PORT LIFEBOAT LIMIT SWITCH PRIOR TO 17JUN99.
Condition: Unknown
Due 26 September 1999
Resolved 26 September 1999
Fire Fighting
Issued 17 November 1997
Resolved
PROVIDE AN APPROPRIATE PROTECTION OF PAINT LOCKER WITH A FIRE EXTINGUISHINGSYSTEM APPROVED BY THE ADMINISTRATION. (SOLAS AMENDED CHAPTER II-2/21) CORRECT TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Electrical
Issued 17 November 1997
Resolved
PROVIDE INSULATED RUBBER FLOOR MATTING AT POWER DISTRIBUTION PANEL IN EMERGENCY GENERATOR ROOM. (SOLAS 74 AMENDED CHAPTER II-1-45.1) CORRECT PRIOR TO 23 DECEMBER 1997).
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Navigation
Issued 15 July 1994
Resolved
U.S. COAST GUARD LIGHT LIST WAS NOT CURRENT EDITION.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Navigation
Issued 15 July 1994
Resolved
VESSEL WAS A PRIORTY 3 WITH AN OUTSTANDING DEFICIENCE. VESSEL WAS BOARDED FOR A NAV SAFETY INSPECTION.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Navigation
Issued 15 July 1994
Resolved
U.S. COAST PILOT WAS NOT CURRENT EDITION.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Documentation
Issued 10 July 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Navigation
Issued 23 July 1993
Resolved
U.S. COAST PILOT NOT CURRENTLY CORRECTED. AGENT BROUGHT ON BOARD CURRENT NOTICE TO MARINERS AND THE COAST PILOT WAS CORRECTED ON THE SPOT.
Condition: Unknown
Due 23 July 1993
Resolved 28 July 1993
Navigation
Issued 23 July 1993
Resolved
LIGHT LIST WAS NOT CURRENTLY CORRECTED. AGENT BROUGHT ON BOARD CURRENT NOTICE TO MARINERS AND LIGHT LIST WAS CORRECTED ON THE SPOT.
Condition: Unknown
Due 23 July 1993
Resolved 28 July 1993
Navigation
Issued 10 March 1989
Resolved
VESSEL TRANSITED PUGET SOUND WATERS UTILIZING CHARTS NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(1)(II) OR EQUIVALENT FOREIGN GOVERNMENT CHARTS IN ACCORDANCE WITH 33 CFR 164.33(B).
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989