Records from 2011 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 23
28 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8357729
1 April 2026
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8343920
10 October 2025
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 8254303
1 May 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8127041
8 May 2024
Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7909696
1 February 2024
COI Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7859216
29 April 2023
Examination of Repairs · Damage Survey · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7677800
13 June 2022
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7479935
8 June 2022
Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7474051
3 May 2022
Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7443474
13 April 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7430612
22 March 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7416621
3 June 2021
Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7229705
27 May 2021
In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7240988
29 April 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7229697
26 May 2020
Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6961949
22 April 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6945329
1 February 2019
Internal Structural Exam · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6617562
15 May 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6423639
18 April 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6394215
5 April 2017
Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6126747
5 April 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6319570
8 April 2016
Hull Examination · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913846
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2026
Resolved
Operator required to have a shut-off valve at the fuel tank manifold that is capable of closing remotely. Valve handle on left pick-up line broke off upon actuation. Must repair/replace to satisfaction of USCG. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 1 April 2026
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 April 2026
Resolved
Firefighting extinguishers must be inspected and maintained in accordance with NFPA 10. Need to verify date of last inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 2 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 February 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The port and starboard engines have excessive vibration, starboardside vibration is worse than the port. Vessel owner must identify and fix the issues and clear it with a CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2024
Resolved 2 February 2024
Resolution: Third party mechanic diagnosed the vibration issue and determined the controls were in the wrong setting, the mechanic conducted a sea trial after resetting the controls and confirmed no vibrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 February 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. The port engine battery was unserviceable and could not start the engine under the battery power. Vessel owner must replace the battery in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2024
Resolved 8 February 2024
Resolution: A new battery was installed to support the port engine.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 February 2024
Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. The waterlight battery was unserviceable and must be replaced to approved type. Vessel restricted to daytime operations only. Once battery is replaced, clear with CG
inspector.
Action required: 705 - Other - as specified
Due 1 February 2024
Resolved 2 February 2024
Resolution: The battery in the waterlight has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 February 2024
Resolved
The portable hand bilge pump shall be provided with suitable hoses for pumping bilges on the suction and discharge ends. The vessel was not equipped with a portable hand bilge pump. Vessel owner must supply adequate portable bilge pump with a minimum pump capacity of 5 gallons per minute. Clear to CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2024
Resolved 2 February 2024
Resolution: The vessel rep purchased a new portable hand pump which is now onboard the DIVER TWO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2023
Resolved
Where both plastic and metallic pipes are used in a bulkhead penetration system, the required shutoff valve shall be installed at the bulkhead in the metallic part of the system. The vessel is not outfitted properly and does not have the required shutoff valves at the bulkhead for the bilge piping in the forward MSD space or the aft engine room compartment. Vessel rep must install shutoff valves in required locations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Shutoff valves were installed properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. The engine room and forward MSD compartments have open electrical buses with corrosion and water on the wires and terminals presenting an electrical hazard. Vessel rep must ensure electrical wiring is protected in a junction box or watertight electrical box in both spaces. OCMI must approve plan prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Open buses are now protected in a marine grade watertight electrical box in both spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2023
Resolved
Electrical equipment exposed to the weather must be watertight. Vessels electrical navigation light wire installation is not watertight, and was shorting when moved and wires with crimped connections are exposed to weather. Vessel rep must ensure wiring is protected and watertight and connection secure to prevent shorting.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Wiring is not in a conduit and is weathertight.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 April 2023
Resolved
Material condition, vessels shall be inspected for compliance with the standards required by this sub chapter. The shaft stern tube has significant galvanic corrosion and must be addressed. Submit plan to identify the source and repair plan proposal. OCMI must approve plan and oversee repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Vessel rep completed approved repair plan, MI tested machinery propulsion, verified new installation sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel, 6 adult life jackets were deemed not serviceable, reduced passenger carriage to 22. OCMI must verify replacement of 6 adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: All L/J's have been replaced and properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2023
Resolved
Portable watertight containers for distress flares and smoke signals. Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in .5 inches high letters DISTRESS SIGNALS. Vessel did not have a watertight container onboard. Vessel rep must store flares in accordance with the regulation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: Flares are now in portable watertight container meeting regs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 April 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel is missing the light for the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: All required lights are onboard and working.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2023
Resolved
Vessel must meet requirements of the Federal Communications Commission FCC, vessel did not have onboard an FCC License.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: FCC License in now onboard
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 April 2023
Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. During the inspection, the EPIRB was activated. Vessel rep must replace the EPIRB and register the new one and show proof of registration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2023
Resolved 19 May 2023
Resolution: New EPIRB installed, new registration completed with new reg sticker
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 April 2023
Resolved
Requirements for alcohol and drug testing following a serious marine incident. Company reps and master were unaware of the time limits for alcohol and drug testing and were unfamiliar with serious marine incident criteria. Recommend refresher training for all crew members, submit proof of refresher training including all employees in attendance, to OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: All employees received refresher training
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 April 2022
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. The welds at attachment bracket for the hydraulic steering ram are fractured. 182.30-1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 12 May 2022
Resolution: 1/2 thick aluminum plate welded in place to provide the required rigidity.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 April 2022
Resolved
Provision must be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Ventilation duct openings on cabin top was not readily accessible and unsafe. Provide alternate means to secure the ventilation openings. 181.20-35
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 12 May 2022
Resolution: New ventilation closers fabricated and tested.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 April 2017
Resolved
Vessel needs to have a full compliment of working navigational lights. The vessels stern light is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: The vessel has a full compliment of working navigational lights.
Engineering › Fuel Oil Service System › Filter
Issued 5 April 2017
Resolved
Vessel fuel strainers need to have proper flame protection installed. Missing flame bowls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Vessel has installed proper flame protection under the strainers.