DIVER TWO is a 1988 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1988, most recently in April 2026, along with 74 deficiencies and 1 casualty investigation in 2011.

Records from 1988 to 2026. Most recent: inspection, 28 April 2026.

Built
1988
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE5511
301098
Flag
UNITED STATES
367367770
Maury page id
psix-301098

Inspections, by type

…with no type recorded9
Years with a record 37 calendar years (1988–2026)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 13.5 ft × 4.5 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMUNSON MFG., INC. · EDMONDS, WA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE5511MMSI 367367770 · active · compulsorily equipped · granted 22 June 2018, expires 10 July 2028
WTA6210MMSI not assigned · expired · compulsorily equipped · granted 14 April 1998, cancelled 16 August 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 84

28 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8357729
1 April 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8343920
10 October 2025 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 8254303
1 May 2025 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8127041
8 May 2024 Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7909696
1 February 2024 COI Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7859216
29 April 2023 Examination of Repairs · Damage Survey · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7677800
13 June 2022 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7479935
8 June 2022 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7474051
3 May 2022 Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7443474
13 April 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7430612
22 March 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7416621
3 June 2021 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7229705
27 May 2021 In-Service Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7240988
29 April 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7229697
26 May 2020 Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6961949
22 April 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6945329
1 February 2019 Internal Structural Exam · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6617562
15 May 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6423639
18 April 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6394215
5 April 2017 Hull Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6126747
5 April 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6319570
8 April 2016 Hull Examination · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5913846
21 July 2015 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5191879
17 July 2015 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5228216
1 May 2014 Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4881521
1 June 2012 Administrative Inspection · Hull Examination · Simplified Stability Test · Internal Structural Exam · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4357392
9 February 2012 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4241773
21 December 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4213372
16 September 2011 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4147068
30 August 2011 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4131396
4 January 2011 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3920475
23 January 2009 DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3399021
13 January 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3393364
10 September 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3322097
14 September 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3057800
23 January 2007 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2954642
17 August 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2850916
24 May 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2544991
16 September 2004 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2319013
2 August 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2296497
12 June 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2135500
27 January 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1994200
18 August 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1880406
3 July 2003 Annual Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1838606
14 January 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1731650
1 August 2002 Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1655185
14 June 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373518
19 April 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 26837
19 March 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1061211
29 January 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361962
23 January 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1057564
9 June 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1399398
2 May 2000 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048539
1 April 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 184005
16 June 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1470219
7 January 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1462718
9 November 1998 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 804101
20 August 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 796774
6 June 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416723
19 June 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364213
26 December 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 162101
7 November 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1460036
10 October 1996 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374765
21 August 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 953735
19 July 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371493
9 January 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 147601
18 May 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357164
16 November 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1444916
27 October 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358596
14 July 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354813
24 March 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1471310
18 June 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154432
13 October 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1265443
14 September 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1263257
28 August 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 958699
29 August 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1308398
30 July 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 939667
13 June 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1352929
7 August 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235535
16 November 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1223810
14 August 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1042168
30 August 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1199118
5 August 1988 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1342231

Deficiency record · 74

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2026 Resolved
Operator required to have a shut-off valve at the fuel tank manifold that is capable of closing remotely. Valve handle on left pick-up line broke off upon actuation. Must repair/replace to satisfaction of USCG. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 1 April 2026
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 April 2026 Resolved
Firefighting extinguishers must be inspected and maintained in accordance with NFPA 10. Need to verify date of last inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 2 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 February 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The port and starboard engines have excessive vibration, starboardside vibration is worse than the port. Vessel owner must identify and fix the issues and clear it with a CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2024
Resolved 2 February 2024
Resolution: Third party mechanic diagnosed the vibration issue and determined the controls were in the wrong setting, the mechanic conducted a sea trial after resetting the controls and confirmed no vibrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 February 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. The port engine battery was unserviceable and could not start the engine under the battery power. Vessel owner must replace the battery in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2024
Resolved 8 February 2024
Resolution: A new battery was installed to support the port engine.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 February 2024 Resolved
Waterlights should be serviceable and batteries replaced annually if not marked with an expiration date. The waterlight battery was unserviceable and must be replaced to approved type. Vessel restricted to daytime operations only. Once battery is replaced, clear with CG inspector.
Action required: 705 - Other - as specified
Due 1 February 2024
Resolved 2 February 2024
Resolution: The battery in the waterlight has been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 February 2024 Resolved
The portable hand bilge pump shall be provided with suitable hoses for pumping bilges on the suction and discharge ends. The vessel was not equipped with a portable hand bilge pump. Vessel owner must supply adequate portable bilge pump with a minimum pump capacity of 5 gallons per minute. Clear to CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2024
Resolved 2 February 2024
Resolution: The vessel rep purchased a new portable hand pump which is now onboard the DIVER TWO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2023 Resolved
Where both plastic and metallic pipes are used in a bulkhead penetration system, the required shutoff valve shall be installed at the bulkhead in the metallic part of the system. The vessel is not outfitted properly and does not have the required shutoff valves at the bulkhead for the bilge piping in the forward MSD space or the aft engine room compartment. Vessel rep must install shutoff valves in required locations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Shutoff valves were installed properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. The engine room and forward MSD compartments have open electrical buses with corrosion and water on the wires and terminals presenting an electrical hazard. Vessel rep must ensure electrical wiring is protected in a junction box or watertight electrical box in both spaces. OCMI must approve plan prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Open buses are now protected in a marine grade watertight electrical box in both spaces.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2023 Resolved
Electrical equipment exposed to the weather must be watertight. Vessels electrical navigation light wire installation is not watertight, and was shorting when moved and wires with crimped connections are exposed to weather. Vessel rep must ensure wiring is protected and watertight and connection secure to prevent shorting.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Wiring is not in a conduit and is weathertight.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 April 2023 Resolved
Material condition, vessels shall be inspected for compliance with the standards required by this sub chapter. The shaft stern tube has significant galvanic corrosion and must be addressed. Submit plan to identify the source and repair plan proposal. OCMI must approve plan and oversee repair.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2023
Resolved 19 May 2023
Resolution: Vessel rep completed approved repair plan, MI tested machinery propulsion, verified new installation sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel, 6 adult life jackets were deemed not serviceable, reduced passenger carriage to 22. OCMI must verify replacement of 6 adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: All L/J's have been replaced and properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2023 Resolved
Portable watertight containers for distress flares and smoke signals. Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in .5 inches high letters DISTRESS SIGNALS. Vessel did not have a watertight container onboard. Vessel rep must store flares in accordance with the regulation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: Flares are now in portable watertight container meeting regs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 April 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel is missing the light for the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: All required lights are onboard and working.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2023 Resolved
Vessel must meet requirements of the Federal Communications Commission FCC, vessel did not have onboard an FCC License.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: FCC License in now onboard
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 April 2023 Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. During the inspection, the EPIRB was activated. Vessel rep must replace the EPIRB and register the new one and show proof of registration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2023
Resolved 19 May 2023
Resolution: New EPIRB installed, new registration completed with new reg sticker
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 April 2023 Resolved
Requirements for alcohol and drug testing following a serious marine incident. Company reps and master were unaware of the time limits for alcohol and drug testing and were unfamiliar with serious marine incident criteria. Recommend refresher training for all crew members, submit proof of refresher training including all employees in attendance, to OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 19 May 2023
Resolution: All employees received refresher training
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 April 2022 Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. The welds at attachment bracket for the hydraulic steering ram are fractured. 182.30-1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 12 May 2022
Resolution: 1/2 thick aluminum plate welded in place to provide the required rigidity.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 April 2022 Resolved
Provision must be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Ventilation duct openings on cabin top was not readily accessible and unsafe. Provide alternate means to secure the ventilation openings. 181.20-35
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 12 May 2022
Resolution: New ventilation closers fabricated and tested.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 April 2017 Resolved
Vessel needs to have a full compliment of working navigational lights. The vessels stern light is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: The vessel has a full compliment of working navigational lights.
Engineering › Fuel Oil Service System › Filter
Issued 5 April 2017 Resolved
Vessel fuel strainers need to have proper flame protection installed. Missing flame bowls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Vessel has installed proper flame protection under the strainers.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 July 2015 Resolved
Vessel had 7 adult lifejackets in dilapidated/unserviceable condition that were taken out of service. Vessel can provide 23 serviceable lifejackets and is therefore restricted IAW 46CFR180.71(a) to carrying 23 persons.
Action required: 705 - Other - as specified
Due 24 July 2015
Resolved 5 April 2017
Resolution: The deficiency was verified to be completed during the 05APR2017 annual inspection. Vessel had all required lifejackets that met CG approval standards onboard.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 July 2015 Resolved
Visual high water alarm not functioning. Vessel must provide visual alarm at operating station IAW 46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2015
Resolution: Wiring was corrected so that lights at operating station activate when high water alarm sounds.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 July 2015 Resolved
Automatic bilge pump indicators not functioning. Vessel must have visual indicator to indicate when an automatic bilge pump is operating IAW 46CFR182.530(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2015
Resolution: Wiring corrected so that light indicator activates when auto bilge pumps are operating.
Engineering › Bilge Water Management System › Valve
Issued 26 June 2012 Resolved
Install a positive shutoff valve at the hull penetration for discharge hose of submersible electric dewatering pumps IAW 46 CFR 182.520(e)(7).
Due 28 June 2012
Resolved 27 June 2012
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 26 June 2012 Resolved
Conduct sea trials upon completion of engine re-power to the satisfaction of an attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2012
Resolved 26 June 2012
Lifesaving › Lifefloat › Markings
Issued 12 April 2012 Resolved
Renew faded life float to original color (international orange).
Due 12 May 2012
Resolved 24 April 2012
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 April 2012 Resolved
Attach lifeline to ring buoy IAW 46 CFR 180.70.
Due 12 May 2012
Resolved 24 April 2012
Construction/Loadline › Hull › Hull Plating
Issued 12 April 2012 Resolved
Make transom penetration watertight in way of swim step mount.
Due 12 May 2012
Resolved 24 April 2012
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 August 2011 Resolved
EAP Display Requirements - Missing
Due 30 September 2011
Resolved 18 October 2011
Resolution: EAP community service hot-line telephone number for crewmember assistance are included in the company policy and will now be posted in the monthly "shop notes."
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 30 August 2011 Resolved
EAP Training Requirements - Missing
Due 30 September 2011
Resolved 22 November 2011
Resolution: Purchased Training Material from Alpha Pro Solutions. Took supervisor training and trained staff
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 30 August 2011 Resolved
Not conducting complete random testing, not completing 50% annual requirement. Expect company to explain how they will ensure that all parties of the drug testing pool are included in the random selection. Company needs to complete at least 8 more random tests for 2011 to be in compliance.
Due 30 September 2011
Resolved 10 January 2012
Resolution: Completed all required random drug tests for 2011.
Documentation › Logs/Records › MIS Form
Issued 30 August 2011 Resolved
MIS Form - Missing
Due 30 September 2011
Resolved 18 October 2011
Resolution: VSL Rep presented the 2010 MIS Form.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2011 Resolved
Crop and renew identified wasted internal hull plating area surrounding starboard exhaust piping prior to receiving credit drydock.
Due 28 February 2011
Resolved 17 February 2011
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2011 Resolved
Crop and renew identified wasted hull plating and associated frames in way of the sewage tank space prior to receiving credit drydock.
Due 28 February 2011
Resolved 17 February 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 September 2007 Resolved
Replace 10 adult and 3 child lifejackets as identified. Jackets are nearing end of service.
Due 29 September 2007
Resolved 2 October 2007
Lifesaving › Lifefloat › Paddle
Issued 14 September 2007 Resolved
Label lifefloat paddles with vessel name.
Due 29 September 2007
Resolved 2 October 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2007 Resolved
Provide all items for first aid kit per list provided by USCG.
Due 29 September 2007
Resolved 2 October 2007
Lifesaving › Lifefloat › Pendant
Issued 14 September 2007 Resolved
Provide pendants for lifefloat IAW 46 CFR 160.027.
Due 29 September 2007
Resolved 2 October 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 September 2007 Resolved
Provide current copy of tide tables for operating area.
Due 29 September 2007
Resolved 2 October 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 August 2006 Resolved
Prove 100% crew training in drill logbook
Due 17 September 2006
Resolved 20 September 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 17 August 2006 Resolved
Install new retro-reflective tape on 5 lifejackets
Due 17 September 2006
Resolved 20 September 2006
Construction/Loadline › Structures › Superstructure
Issued 17 August 2006 Resolved
Replace crqacked window on stbd side of bridge
Due 17 September 2006
Resolved 20 September 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 August 2006 Resolved
Secure painter and light to lifefloat tab and not grab lines
Due 17 September 2006
Resolved 20 September 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 16 September 2004 Resolved
Obtain copy of FCC Safety Certificate
Due 16 December 2004
Resolved 5 January 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 16 September 2004 Resolved
Provide an updated list of employees covered under company drug program
Due 16 December 2004
Resolved 5 January 2005
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 16 September 2004 Resolved
Obtain rules of the road, light list, coast pilot, and tides + currents.
Due 16 December 2004
Resolved 5 January 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 16 September 2004 Resolved
Provide adequate means to secure engine room ventilation
Due 16 December 2004
Resolved 5 January 2005
Lifesaving › Lifefloat › Float-free Link
Issued 16 September 2004 Resolved
Replace weak link to lifefloat
Due 16 December 2004
Resolved 5 January 2005
Construction/Loadline › Hull › Hull Plating
Issued 16 September 2004 Resolved
Replace zincs throughout vessel at next drydock (Jan 05)
Due 31 January 2005
Resolved 5 January 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 3 July 2003 Resolved
Service all portable fire extinguishers. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 15 July 2003
Lifesaving › Lifejacket/PFD (General)
Issued 1 August 2002 Resolved
Provide four additional adult life jackets. The vessel shall not carry more than 26 adults until a Marine Inspector clears this requirement. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 18 September 2002
Operations/Management › Drills/Instruction
Issued 1 August 2002 Resolved
Update vessel's drill log.
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 18 September 2002
Engineering › Bilge Water Management System
Issued 1 August 2002 Resolved
Repair the engine room bilge alarm.
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 18 September 2002
Engineering › Bilge Water Management System
Issued 1 August 2002 Resolved
Install a bilge alarm in the sewage tank space.
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 18 September 2002
Stability › Watertight Integrity
Issued 1 August 2002 Resolved
Provide a means to secure the engine room hatches.
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 18 September 2002
Documentation
Issued 7 January 1999 Resolved
Obtain valid FCC Safety Radio Certificate.
Condition: Unknown
Due 7 February 1999
Resolved 23 February 1999
Lifesaving
Issued 7 January 1999 Resolved
Perform and log emergency drills as required.
Condition: Unknown
Due 7 February 1999
Resolved 23 February 1999
Navigation
Issued 7 January 1999 Resolved
Provide current navigational chart of operational area for vessel.
Condition: Unknown
Due 7 February 1999
Resolved 23 February 1999
Electrical
Issued 6 June 1998 Resolved
Install ventilation in MSD/battery compartment in accordance with 46CFR111.15-10(d) or relocate batteries to engine compartment.
Condition: Unknown
Due 6 June 1998
Resolved 6 June 1998
Fire Fighting
Issued 6 June 1998 Resolved
Service all portable fire extinguishers.
Condition: Unknown
Due 6 June 1998
Resolved 6 June 1998
Navigation
Issued 19 July 1996 Resolved
EXTEND NIGHT DIVE LIGHTS TO PROPER DISTANCE OF SEPERATION IAW NAVIGATION RULES.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Construction/Loadline
Issued 19 July 1996 Resolved
INSTALL DOUBLE HOSE CLAMPS ON ALL ELECTRIC BILGE PUMP HOSES' AT THE PUMP & THRU HULL AND INSTALL POSITIVE ACTIVE SHUT OFF VALVES AT EACH THRU HULL.
Condition: Unknown
Due 19 July 1996
Resolved 19 July 1996
Construction/Loadline
Issued 27 October 1994 Resolved
Paint vessel name and hailing port on stern in contrasting color to vessel hull._x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 27 October 1994 Resolved
Renew gasket material on both engine room watertight hatches.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Engineering
Issued 27 October 1994 Resolved
Permanently repair S/W leak on stbd MDE exhaust pipe located at aft connection of the muffler._x001C_
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Engineering
Issued 27 October 1994 Resolved
Provide an electrical bonding strap for the fuel tank fill hose.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Engineering
Issued 28 August 1992 Resolved
INSTALL HEAT SHIELD FOR RACOR FILTER ON STARBOARD SIDE.
Condition: Unknown
Due 28 August 1992
Resolved 28 August 1992
Engineering
Issued 30 July 1991 Resolved
INSTALL THE FUEL SHUTOFF VALVES AT THE TANK SO THEY ARE OPERABLE FROM THE OUTSIDE THE TANK COMPARTMENT, PREFERABLY FROM AN ACCESSIBLE POSITION ON THEWEATHER DECK.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Documentation
Issued 5 August 1988 Resolved
PROVIDE CURRENT COPY OF 46 CFR, SUBCHAPTER T.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Lifesaving
Issued 5 August 1988 Resolved
PROVIDE ONE ADDITIONAL ADULT AND ONE ADDITIONAL CHILD PERSONAL FLOATATION DEVICE.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Navigation
Issued 5 August 1988 Resolved
SWING/BOX COMPASS AND PROVIDE ACCURATE DEVIATION TABLE.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Unknown
Issued 5 August 1988 Resolved
MAKE VESSEL AVAILABLE FOR INSPECTION BY [name withheld], HI. PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Navigation
Issued 5 August 1988 Resolved
PROVIDE UP TO DATE CHARTS, AND TIDE/CURRENT TABLES FOR AREA OF OPERATION.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Documentation
Issued 5 August 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988

Casualty record · 1

21 December 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4213372
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.