← All vessels
AUTO BANNER
AUTO BANNER is a 1988 freight ship. The Coast Guard has recorded 53 inspections since 1988, most recently in February 2018, along with 29 deficiencies and 3 operational controls.
Records from 1988 to 2018. Most recent: inspection, 1 February 2018.
- Built
- 1988
- Last inspected
- 1 February 2018
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8608066 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FVN2
301110
Flag
PANAMA
—
Maury page id
psix-301110
Inspections, by type
…with no type recorded31
Years with a record
24 calendar years (1988–2018)
The 53 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it52442 - Regulatory (Subpart C or D), Gross Ton
52422 - Convention (Subpart B), Gross Ton
23052 - Dead Weight, Ton
37320 - Displacement, Ton
17216 - Convention (Subpart B), Net Ton
52422 - Convention (Subpart B), Gross Ton
23052 - Dead Weight, Ton
37320 - Displacement, Ton
17216 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 53
1 February 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6346617
8 July 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6199831
22 May 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6152670
31 August 2016
PI Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5988621
20 May 2016
Ballast Water Examination · ISPS III Exam · Deficiency Check · PII Safety Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5875228
5 April 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5848050
25 March 2016
PI Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5840503
14 February 2016
Deficiency Check · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5811716
16 August 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4944631
27 December 2010
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3914662
16 February 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3418553
24 October 2008
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3350091
8 March 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3160826
8 March 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3161285
6 March 2008
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3159626
27 July 2006
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2726180
27 July 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2726562
26 July 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2725678
28 May 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2371849
15 March 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2310583
31 October 2004
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2231875
26 February 2003
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1749661
12 November 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1701231
7 November 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1702375
25 August 2002
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1665969
24 August 2002
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1670462
19 August 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1663430
19 May 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1616906
11 February 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 287007
3 July 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 279419
9 April 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 276489
25 March 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 426825
30 December 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 411315
23 December 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 411277
24 September 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 395678
21 September 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 395612
17 September 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 395376
15 September 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 395374
17 August 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 381629
15 February 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 375247
14 January 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 54023
12 September 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 370377
15 August 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 369414
2 June 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 540284
16 December 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 483049
9 December 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 355091
23 April 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 504546
24 August 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 345570
6 May 1991
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 343640
2 November 1989
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 436466
17 May 1989
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 330412
9 November 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 474183
21 April 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 322970
Deficiency record · 29
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 22 May 2017
Resolved
0610: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. During lowering and recovery of #2 lifeboat, brake lever bent and failed resulting in the release of lifeboat to the waterline. Control wire rope frayed and broke as a result of being caught in winch cable spool. 74 SOLAS (14 CONS.) III/20.2
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 May 2016
Resolved
1730-Oily-water separating equipment-The oil filtering equipment shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. When effluent exceeds 15ppm the oily water separator fails to stop the flow of discharge overboard-MARPOL Annex I/14.7
Engineering › Compressed Air System (control) › Valve
Issued 7 April 2016
Resolved
74 SOLAS (97 CONSD) II-2 / 5.1.11 - A means shall be provided for the crew to safetl check the quantity of medium in the containers. The liquid level isolation valves on the containers were completely iced over.
Lifesaving › Launching Appliances › Winch
Issued 14 February 2016
Resolved
0613 - Stowage of Lifeboats - Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. Port davit winch and starboard rescue boat davit winch inoperable. 74 SOLAS (14) III/ 20.2 Action: 30abc
Lifesaving › Launching Appliances › Winch
Issued 14 February 2016
Resolved
0999 - Other (safety in general) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship and all respects will remain fit to proceed to sea without danger to the ship or persons on board. Supply line to pneumatic winch on port lifeboat ruptured in two locations. 74 SOLAS (14) I/11 Action: 30abc
Lifesaving › Lifebuoys › Size
Issued 14 February 2016
Resolved
0650 - Lifebouys - Each lifebuoy intended to operate the quick-release arrangement for the self-activated smoke signals and self-igniting lights, have a mass sufficient to operate the quick-release arrangement or 4 kg whichever is greater. The lifebuoy on the stbd bridge wing connected to the light and smoke signal has been found to be less than 4kg. SOLAS (97)III/31.1.7 Action: 40ac
Operations/Management › Pollution › Control of Garbage
Issued 14 February 2016
Resolved
2120 - Garbage - Every ship of 400 GT and above shall carry a garbage management plan which the crew shall follow. Plastics were found in the food waste which violates the garbage management plan. MARPOL 73/78 Annex V/ 9.2 Action: 10c
Stability › Weathertight Integrity › General
Issued 8 March 2008
Resolved
Vessel sustained damage to stern loading ramp during excessively high winds while moored (lower flap of ramp sheared off). Vessel unable to load/unload cargo in current condition. Vessel to provide proof of proper operation of ramp including weather/water tight integrity as well as temp or permanent repairs to the satisfaction of class.
ICLL 66 Annex I Reg 14, 27
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 6 March 2008
Resolved
Bridge did not receive audible alarm when power was secured to number one and two steering pumps. Corrected during inspection by replacing cable and tested to satisfaction of Coast Guard.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 July 2006
Resolved
Fire door on deck 6A leading to car deck from stairway will not fully close. Tension device pulling off of door frame, one broken rivet and one screw pulling out of frame.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 15 March 2005
Resolved
REPLACE DAMAGED FOOD RATIONS (VAPOR SEAL BROKEN), 4 PORT, 2 STBD, FOR A TOTAL OF 6 RATIONS TOTALING NOT LESS THAN 10,000 KJ EACH.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 February 2003
Resolved
All three ship service generator control boxes are missing back panels, a violation of SOLAS 74/78 II-1/45-1.3 and 45-2.
Construction/Loadline › Hull
Issued 25 August 2002
Resolved
COMPLETED TEMP. REPAIRS TO STBD AFT QTR. RECIEVED CLASS REPORT NO: KRNYK 0024-002 DATED 26AUG02. ATTESTING TO TEMP. REPAIRS AND PERMANT REPAIRS NLT 25NOV02. USCG MARINE INSPECTOR ACT BALT ATTESTED TO TEMP REPAIR. PERMANT REPAIRS TO BE COMPLETED PRIOR TO NEXT US PORT CALL AFTER SAILING FORIEGN LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 25 August 2002
Resolved
VESSEL DAMAGED ON STARBOARD SIDE AFT QUARTER AT 9.8M MARK. HOLED APPROX. 3M LOG BY 0.5M WIDE. VESSEL TO PROVIDE CLASS REPORT OF DAMAGED AREA WITH PROPOSAL FOR REPAIR TO US COAST PRIOR TO EFFECTING REPAIR LEGACY COMPONENT DESC: Hull Plating
Operations/Management
Issued 25 August 2002
Resolved
VESSEL IS AUTHORIZED TO SHIFT BERTHS TO ADJACENT PIER TO AFFECT REPAIRS
LEGACY COMPONENT DESC: AUTHORIZED FOR BERTH SHIFT
Construction/Loadline › Hull
Issued 25 August 2002
Resolved
VESSEL TO PROVIDE CLASS REPORT OF COMPLETED REPAIRS TO US COAST GUARD PRIOR TO DEPARTURE LEGACY COMPONENT DESC: Hull Plating
Operations/Management
Issued 25 August 2002
Resolved
VESSEL TO SUBMIT COMPLETED CG 2692 TO US COAST GUARD PRIOR TO SAILING LEGACY COMPONENT DESC: CG 2692
Accommodation/Occupational Safety › Washroom/Toilet
Issued 19 May 2002
Resolved
Toilet in hospital space not operational - will not flush. Diaphragm leaking on 13th deck below hospital space. Repair and supply class report to USCG. LEGACY COMPONENT DESC: Toilet
Lifesaving › Liferaft Equipment
Issued 19 May 2002
Resolved
Max storage height for liferafts is 18 meters, liferafts stored at about 25 meters. Have class address liferaft storage height. Need certificate from class/manufacturer stating that liferaft storage is acceptable. Drop test was performed on 20 Jun 00 but no certificate issued.
Navigation
Issued 11 February 2001
Resolved
Stbd electric motor shaft/hydraulic oil tank for emergency steering has an excessive oil leak at the seal where the shaft enters the tank. IAW SOLAS 74/78 II-1/29.
Electrical
Issued 9 April 2000
Resolved
Repair full phase ground in the emergency switchboard prior to return to a U. S. port from sailing foreign. The ground is reportedly in the WX deck lighting system. _x001C_ SOLAS 74 amd II-1/40.1
Electrical
Issued 23 December 1997
Resolved
PROPERLY DEAD END/DISCONNECT ELECTRICAL LIVE WIRES IN LAUNDRY ROOM. (SOLAS 74 AMENDED REG. II-1/45.1) CORRECT PRIOR TO NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 23 December 1997
Resolved
MAKE SATISFACTORY REPAIRS TO THE SEWAGE PIPE LEAK ON MARINE SANITATION DEVICE. (SOLAS 74 AMENDED REG. II-2/15.2) CORRECT PRIOR TO NEXT U.S. PORT.
Engineering
Issued 15 September 1996
Resolved
OILY WATER SEPERATOR WAS INOPERATIVE AND DISASSEMBLED. REPAIR PRIOR TO ARRIVAL NEXT U.S. PORT.
Navigation
Issued 15 August 1994
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH CHARTS 12326, 12327, 12333, AND 12334 NOT CORRCTED UP TO DATE AS REQUIRED BY 33 C.F.R. 164.33(a)(1)(ii).
Navigation
Issued 9 December 1992
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE CHARTS FOR JACKSONVILLE WERE NOT CORRECTED FOR PORT OF JACKSONVILLE. THESE CHARTS SHOULD HAVE BEEN CORRECTEDTHRU NTM 41-92 FOR CHART 11491 AND NTM 25-92 FOR CHART 11490. THESE CORRECTIONS WERE APPLICABLE AND READILY AVAILABLE TO THE VESSEL.
Navigation
Issued 6 May 1991
Resolved
A VIO OF 33CFR164.30 IN THAT THE US COAST PILOT (VOL 3) USED BY THE VSL WASNOT CORRECTED THRU NTMS 7/91, WHICH WERE REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS APPLICABLE TO THE VSLS RTE FROM SMITH PT VA TO BALTO HARBOR. NOFOREIGN EQUIVALENT O/B.
Navigation
Issued 6 May 1991
Resolved
A VIO OF 33CFR164.30 IN THAT THE USCG LIGHT LIST (VOL 2) USED BY THE VSL WAS NOT CORRECTED THRU NTMS 7/91, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS RTE FROM SMITH PT VA TO BALTO HARBOR. NO FOREIGN EQUIVALENT O/B.
Navigation
Issued 21 April 1988
Resolved
NOS CHARTS 18740 NOT CORRECTED TO DATE AND 18746 OR FOREIGN EQUIVALENTS NOT ON BOARD.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.