Records from 2016 to 2026. Most recent: inspection, 8 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)77.5 ft × 25.4 ft × 6.6 ft
Registered tonnagegross 76 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROS ENTERPRISES · LOREAUVILLE, LA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 2 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
23 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 23
8 April 2026
MSP Additional Oversight - Risk Assessment · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344422
12 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8266726
9 April 2025
MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8108179
9 April 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7892595
16 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7825533
18 October 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7810395
12 April 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7594891
19 November 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7596907
10 May 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7447725
13 April 2022
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7424334
10 November 2021
Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7348601
3 September 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7312274
28 July 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7270454
16 July 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7258029
19 April 2021
Internal Structural Exam · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7178089
27 May 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6964653
9 December 2019
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6869752
17 April 2019
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6665181
23 April 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6397214
20 November 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339613
30 October 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6297525
10 April 2017
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6121402
5 April 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847411
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2026
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips are expired. 46 CFR 4.06-15 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 22 April 2026
Resolution: Resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2026
Resolved
The VSO must ensure that at least one security drill is conducted at least every 3 months, except when a vessel is out of service due to repairs or seasonal suspension of operation provided that in such cases a drill must be conducted within one week of the vessel's reactivation. Security drills may be held in conjunction with non-security drills where appropriate. Vessel has not conducted security drills as required by applicable regulations. Conduct security drill.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 20 April 2026
Resolution: Rectified. Conducted security drill. All sat.
14 - Pollution Prevention › 143 - MARPOL Annex III › Other (MARPOL Annex III)
Issued 8 April 2026
Resolved
All personnel must complete the training specified in
paragraphs (d)(1)(ii) through (v) of this section by January 12, 2026, and annually thereafter. Crew did not complete cyber security training. Complete cyber security training.
33 CFR 101.650(d)(4)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 June 2026
Resolution: Cyber security training has been conducted with crew.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 November 2025
Resolved
Found 02 cracked welds on longitudinal framing inboard of the clete support framing on port and starboard sides. Complete repairs prior to credit drydock/within 14 days.
Action required: 705 - Other - as specified
Resolved 15 January 2026
Resolution: Recieved pictures from operator attesting to repairs inside of the forepeak.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 April 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flares... and six hand orange smoke distress signals. Identified 04 missing flares. Limit route to lakes, bays, and sounds until flares onboard.
46CFR117.68 (a)(1) & (2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 November 2025
Resolution: Flares on board.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2025
Resolved
Vessels described by 46 CFR 114.110(e) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. MI Identified no fire detection in the accommodation space. Submit repair plan within 30 days.
46 CFR 118.400(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 November 2025
Resolution: Interconnected fire detection system installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 18 October 2023
Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of—(1) The location of emergency exits, survival craft embarkation areas, and ring life buoys;(2) The stowage location(s) of life jackets;(3) Either:(i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning of a lifejacket, or(ii) That passengers may contact a crew member for a demonstration, as appropriate, prior to beginning an oceans or coastwise voyage;(4) The location of the instruction placards for life jackets and other lifesaving devices;(5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master; and(6) If the vessel is operating with reduced manning or equipment requirements in § 115.114 of this chapter. Vessel's master was unable to remember all required items or produce written passenger brief. 46 CFR 122.506
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 16 November 2023
Resolution: Vessel has developed and implemented a written passenger brief. Deficiency has been resolved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 October 2023
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Port side fire station did not have the fire hose connected. Crew connected hose to the hydrant after being informed of requirement. 46 CFR 118.320(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 October 2023
Resolved 18 October 2023
Resolution: Crew connected hose to hydrant when inspectors were on board.