Inspection record

Last inspected 15 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI7960
301352
Flag
UNITED STATES
Maury page id
psix-301352

Documentation record

Registered dimensions (L × B × D)77.7 ft × 28.6 ft × 8.4 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBLDG · SOMERSET, MA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMUNISING, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
90 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 33 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

15 June 2026 COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8385714
28 April 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8358070
8 September 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8234552
3 June 2025 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8173935
9 September 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8003948
19 August 2024 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7984955
19 August 2024 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7997098
3 June 2024 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7964330
7 September 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7789312
5 September 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7795883
10 August 2023 Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7770670
13 June 2023 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7742578
22 May 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7700196
15 September 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7560274
15 July 2022 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7552364
7 June 2022 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7476521
31 May 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7464146
25 May 2022 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7476599
12 April 2022 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7431824
8 September 2021 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7317128
17 June 2021 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7200406
15 April 2021 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7178599
15 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7062717
11 November 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6860742
3 September 2019 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6810835
14 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6540422
6 September 2018 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6534893
2 May 2018 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6422077
13 September 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6269679
21 June 2017 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6182198
24 August 2016 Deficiency Check · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5983997
17 August 2016 DAPI Audit
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6047331
24 May 2016 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5893058

Deficiency record · 25

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 June 2025 Resolved
Both sponson forepeaks have frame cracks which require permanent repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 13 June 2025
Resolution: permanent repairs completed, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 June 2025 Resolved
Maindeck forward watertight door gasket is worn & no longer seals properly, must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2025
Resolved 28 April 2026
Resolution: Corrected last season however O/O failed to notify our office. Confirmed gasket was replaced, inspected all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 3 June 2025 Resolved
MOB recovery davit line is chaffed, must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 June 2025
Resolved 3 June 2025
Resolution: Corrected prior to our departure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Conduct a damage survey and affect necessary repairs to the satisfaction of the USCG. 46 CFR 116.100(a) / 701 / c
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 August 2024
Resolved 28 August 2024
Resolution: completed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 June 2023 Resolved
Anchor light inop. Correct and demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2023
Resolved 26 June 2023
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 June 2023 Resolved
GPS/chart plotter requires updating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 12 July 2023
Resolution: resolved.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 June 2022 Resolved
#2 port side void has cracked weld forward as marked. Monitor & repair required after this operating season.
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 22 May 2023
Resolution: repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 June 2022 Resolved
Halon bottles need anti-chafe material installed at mounting plate.
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 22 May 2023
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 June 2022 Resolved
Both bow fuel tank vents require flame screen installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 15 July 2022
Resolution: confirmed corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 June 2021 Resolved
STBD GENSET in inoperable due to a mechanical failure. Troubleshoot and make operable again to the satisfaction of the attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 June 2021
Resolved 22 June 2021
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 June 2021 Resolved
Found port engine room to be dirty and oil coated. Clean port engine room to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 22 June 2021
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 June 2021 Resolved
Found cracked glass on the door to the second deck passenger cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 22 June 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 September 2019 Resolved
Provide servicing reports for stbd FFE system and fire detection system. 46CFR115.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 11 November 2019
Resolution: received report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 4 September 2019 Resolved
Port MDE exhaust lagging dilapidated, must be replaced. 46CFR116.970
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 16 September 2019
Resolution: replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2019 Resolved
2nd deck child size lifejackets must be stowed segregated from adult lifejackets. 46CFR117.78
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2019
Resolved 16 September 2019
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018 Resolved
The vessel is currently broadcasting (1) Improper Name, (2) Zero Length and Beam, (3) No Shit Type. Vessel must use ship type per the US official encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2018
Resolved 9 October 2018
Resolution: Information has been updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2018 Resolved
Lifebuoy on bridge must be properly marked with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 24 September 2018
Resolution: Lifebuoy properly marked
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2018 Resolved
Renew retro reflective tape on 13 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 24 September 2018
Resolution: Lifejackets removed, vessel carries 390 functional lifejackets which is above required amount.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 September 2018 Resolved
Replace EPIRB hydrostatic release due to expiration date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 24 September 2018
Resolution: EPIRB hyrdrostatic release replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 September 2018 Resolved
Replace batteries in emergency lights on all decks and ensure proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 24 September 2018
Resolution: All batteries replaced, lights are fully functional
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 September 2018 Resolved
Replace first aid kit due to expired medication and outdated supplies.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2018
Resolved 24 September 2018
Resolution: New first aid kit purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2018 Resolved
Ensure exhaust lagging is cleaned and replaced in areas of wear on port side engine.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2018
Resolved 9 October 2018
Resolution: Owner replaced lagging with temp exhausted blankets, a permenant installation has been ordered.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 September 2018 Resolved
Remove old flexibale hydraulic line on starboard side rudder installation and cap valves, if necessary.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2018
Resolved 24 September 2018
Resolution: Hydraulic line removed
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 September 2017 Resolved
Properly mount stbd engineroom portable fire ext.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 20 September 2017
Resolution: Received photo showing proper mounting.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 August 2016 Resolved
No training for supervisors in order to do reasonable cause testing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 17 August 2016
Resolution: Training ordered for supervisors