MAURY USCG vessel records Sign in
← All vessels

ANTICIPATION II *

ANTICIPATION II * is a 1988 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1988, most recently in June 2001, along with 73 deficiencies — 5 with no resolution recorded —.

Records from 1988 to 2001. Most recent: inspection, 6 June 2001.

Built
1988
Last inspected
6 June 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUU8054
301397
Flag
UNITED STATES
—
Maury page id
psix-301397

Inspections, by type

…with no type recorded10
…past their stated due date5
Years with a record 14 calendar years (1988–2001)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Net Ton
39 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY4509MMSI not assigned · expired · compulsorily equipped · granted 10 June 1998, cancelled 16 August 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

6 June 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1379479
16 October 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 822137
3 August 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1437764
28 June 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 819306
9 June 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1444351
27 January 2000 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 814359
24 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1046502
27 July 1999 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1106241
1 June 1999 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 804931
2 February 1999 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1125363
7 August 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 720044
19 July 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 77965
13 April 1998 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 788572
7 August 1997 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 782666
31 July 1997 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 781581
24 June 1997 Re-Inspection · Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1113966
2 May 1997 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1406140
31 December 1996 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1454384
26 July 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1380665
25 March 1996 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437091
23 January 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 885791
20 June 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 878285
17 May 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1236185
30 March 1995 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 861018
21 February 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1177660
7 March 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176766
28 May 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146415
11 March 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838707
23 February 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149405
21 September 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 958013
3 March 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1255334
11 March 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 899977
5 March 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1238009
19 March 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 929791
18 September 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1335378
3 April 1989 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1200204
17 February 1989 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 900528
1 November 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 889675
15 April 1988 Initial Construction-Excluding Oversight · Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1345617

Deficiency record · 73

Construction/Loadline
Issued 3 August 2000 No resolution recorded
Prior to the completion of a Credit Drydock Examination, submit repair proposal for wasted areas above main deck, fuel oil sounding tube STBD side, stern PORT and STBD, and cracks under windows, (etc. etc. etc).
Condition: Unknown
Due 4 August 2000 — due date passed with no resolution recorded
Construction/Loadline
Issued 3 August 2000 No resolution recorded
Prior to the completion of a Credit Drydock Examination, repair all wasted deck hatches so they are watertight.
Condition: Unknown
Due 4 August 2000 — due date passed with no resolution recorded
Engineering
Issued 3 August 2000 No resolution recorded
Prior to the completion of a Credit Drydock Examination, replace both PORT and STBD strut bearings.
Condition: Unknown
Due 4 August 2000 — due date passed with no resolution recorded
Construction/Loadline
Issued 3 August 2000 No resolution recorded
Prior to the completion of a Credit Drydock Examination, remove all carpet on 2nd deck for inspection. We were told that the vessel has several deck areas that are wasted and that are cosmetically covered.
Condition: Unknown
Due 4 August 2000 — due date passed with no resolution recorded
Construction/Loadline
Issued 3 August 2000 No resolution recorded
Prior to the completion of a Credit Dry Dock Examination, submit repair proposal for all undersized readings to the local USCG [name withheld].
Condition: Unknown
Due 4 August 2000 — due date passed with no resolution recorded
Documentation
Issued 1 June 1999 Resolved
PROVIDE CURRANT STAMP ON CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 1 July 1999
Resolved 21 July 1999
Lifesaving
Issued 1 June 1999 Resolved
REINSTALL AC BELT COVER.
Condition: Unknown
Due 1 July 1999
Resolved 21 July 1999
Accommodation/Occupational Safety
Issued 1 June 1999 Resolved
DOUBLE HOSE CLAMP SEWAGE LINE.
Condition: Unknown
Due 1 July 1999
Resolved 21 July 1999
Construction/Loadline
Issued 1 June 1999 Resolved
DOUBLE HOSE CLAMP SEA WATER HOSE ON GENERATOR.
Condition: Unknown
Due 1 July 1999
Resolved 21 July 1999
Lifesaving
Issued 1 June 1999 Resolved
REPAIR RING BUOY WATER LIGHT AND ATTACH WATER LIGHT LINE WITH HALYARD CLIP AROUND BODY OF RING BUOY.
Condition: Unknown
Due 1 July 1999
Resolved 4 June 1999
Construction/Loadline
Issued 1 June 1999 Resolved
REPLACE WASTED BILGE STRAINER IN FWD COMPARTMENT.
Condition: Unknown
Due 1 July 1999
Resolved 21 July 1999
Fire Fighting
Issued 1 June 1999 Resolved
SERVICE FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 July 1999
Resolved 4 June 1999
Electrical
Issued 1 June 1999 Resolved
HARD WIRE FREEZER.
Condition: Unknown
Due 1 July 1999
Resolved 21 July 1999
Electrical
Issued 1 June 1999 Resolved
REWIRE AC CONDENSATE BILGE PUMP.
Condition: Unknown
Due 1 July 1999
Resolved 21 July 1999
Documentation
Issued 13 April 1998 Resolved
Document missing renewal sticker.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Documentation
Issued 13 April 1998 Resolved
Operator does not have an FCC operators license.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Construction/Loadline
Issued 13 April 1998 Resolved
Repair light for automatic bilge pump in engine room.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Engineering
Issued 13 April 1998 Resolved
Properly label emergency fuel shut offs.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Construction/Loadline
Issued 13 April 1998 Resolved
Replace wasted strainers on bilge suctions.
Condition: Unknown
Due 13 April 1998
Resolved 13 April 1998
Accommodation/Occupational Safety
Issued 24 June 1997 Resolved
REPAIR LEAKS TO SUPPLY WATER FOR A/C UNITS.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Electrical
Issued 24 June 1997 Resolved
REMOVE HOTPLATES & WAFFLE MAKER.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Lifesaving
Issued 24 June 1997 Resolved
PAINT & LABEL VISUAL DISTRESS SIGNALS BOX.
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Fire Fighting
Issued 24 June 1997 Resolved
MAKE PERMANENT REPAIRES TO FIREMAIN STANDPIPE.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Lifesaving
Issued 24 June 1997 Resolved
Renew grab stbd aft ring buoy.
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Accommodation/Occupational Safety
Issued 24 June 1997 Resolved
REPAIR LEAKING SINK DRAINS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Lifesaving
Issued 24 June 1997 Resolved
Replace 8 pfds
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Fire Fighting
Issued 24 June 1997 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Fire Fighting
Issued 24 June 1997 Resolved
REPLACE FIRE HOSES.
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Accommodation/Occupational Safety
Issued 24 June 1997 Resolved
SUPPORT A/C WATER LINES.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Construction/Loadline
Issued 24 June 1997 Resolved
REPAIR HINGE TO PORTSIDE FWD LOADING DOOR.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Fire Fighting
Issued 24 June 1997 Resolved
MAKE TEMPORARY REPAIRS TO PORT FIREMAIN STANDPIPE SO IT DOES NOT MOVE OR LEAK WATER AROUND BASE INTO INTERIOR.
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Construction/Loadline
Issued 24 June 1997 Resolved
SEAL OVBD DISCH LOCATED STBD SIDE OF A/C SPACE ABOUT 1/2 WAY BACK FROM FWD BLKHD.
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Lifesaving
Issued 24 June 1997 Resolved
REPLACE 60' OF LINE AND WATER LIGHT LINE FOR RING BUOY UPPER DECK STBD SIDE.
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Unknown
Issued 24 June 1997 Resolved
RENEW UPPER DECK CAPACITY WARNINGS.
Condition: Unknown
Due 24 June 1997
Resolved 30 July 1997
Construction/Loadline
Issued 2 May 1997 Resolved
Make permanent repairs to port quarter bulwarks and upper deck support structure above main deck.
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Deck/Cargo
Issued 2 May 1997 Resolved
Provide proper anchor and anchor line prior to carrying passengers.
Condition: Unknown
Due 2 June 1997
Resolved 23 June 1997
Construction/Loadline
Issued 2 May 1997 Resolved
Grind and re-weld as necessary fractured welds in lazarette side shell/frame connections.
Condition: Unknown
Due 2 June 1997
Resolved 23 June 1997
Electrical
Issued 2 May 1997 Resolved
Remove dead-ended wiring from engine room._x001C_ _x001C_
Condition: Unknown
Due 2 June 1997
Resolved 23 June 1997
Construction/Loadline
Issued 2 May 1997 Resolved
Crop and renew as original wasted frame under aft side of fresh water tank.
Condition: Unknown
Due 2 June 1997
Resolved 23 June 1997
Construction/Loadline
Issued 2 May 1997 Resolved
Make forward engine room bulkhead watertight.
Condition: Unknown
Due 2 June 1997
Resolved 23 June 1997
Engineering
Issued 2 May 1997 Resolved
Provide proper supports for exhaust piping.
Condition: Unknown
Due 2 June 1997
Resolved 23 June 1997
Engineering
Issued 2 May 1997 Resolved
Install flame shields on Raycor filters prior to carrying passengers._x001C_
Condition: Unknown
Due 2 June 1997
Resolved 23 June 1997
Unknown
Issued 25 March 1996 Resolved
REPLACE MISSING PIECES OF INSULATION IN ENGINEROOM OVERHEAD.
Condition: Unknown
Due 2 April 1996
Resolved 9 May 1996
Engineering
Issued 25 March 1996 Resolved
REPAIR WATER/EXHAUST LEAK ON PORT ENGINE.
Condition: Unknown
Due 2 April 1996
Resolved 9 May 1996
Accommodation/Occupational Safety
Issued 25 March 1996 Resolved
LABEL EACH STAIR TO UPPER DECK 60 PERSONS MAXIMUM.
Condition: Unknown
Due 2 April 1996
Resolved 9 May 1996
Documentation
Issued 17 May 1995 Resolved
Change managing owners address on documentation papers to reflect correct suite number. Provide this office with copy of corrected certificate.
Condition: Unknown
Due 25 June 1995
Resolved 7 June 1995
Electrical
Issued 30 March 1995 Resolved
Replace missing circuit breaker in distribution panel or blank off opening.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Engineering
Issued 30 March 1995 Resolved
Demonstrate proper operation of both main engines and the PTO bilge pump.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 30 March 1995 Resolved
Properly mount the fire extinguisher behind the bar. Label its location.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 30 March 1995 Resolved
Provide 6 hand held orange smoke and 3 hand held red flares.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 30 March 1995 Resolved
Replace the line around the ring buoy stored on the bow.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995
Navigation
Issued 30 March 1995 Resolved
Properly align the masthead light. It is bent back.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Accommodation/Occupational Safety
Issued 30 March 1995 Resolved
Post the emergency check off list as required by 46 CFR 185.25
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 30 March 1995 Resolved
Service all portable fire extinguishers prior to carrying passengers.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 30 March 1995 Resolved
Attach the waterlight to the ring buoy on its own lanyard vice the 60' line.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Electrical
Issued 30 March 1995 Resolved
Properly hard wire the A/C condensate ovbd pump in the forward hold space.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Construction/Loadline
Issued 7 March 1994 Resolved
REPLACE WASTED BILGE STRAINER IN #3 COMPARTMENT.
Condition: Unknown
Due 21 March 1994
Resolved 7 September 1994
Lifesaving
Issued 7 March 1994 Resolved
REPLACE GRABLINE ON RING BOUY.
Condition: Unknown
Due 21 March 1994
Resolved 7 September 1994
Construction/Loadline
Issued 7 March 1994 Resolved
PROVE PROPER OPERATION OF BILGE LINE AND PTO PUMP IN ENGINE ROOM.
Condition: Unknown
Due 21 March 1994
Resolved 7 September 1994
Engineering
Issued 7 March 1994 Resolved
REPAIR LEAKS ON FEED WATER LINE TO PORT SHAFT PACKING GLAND.
Condition: Unknown
Due 21 March 1994
Resolved 7 September 1994
Electrical
Issued 7 March 1994 Resolved
PROPERLY SECURE ALL DEAD END WIRES IN ENGINE ROOM AND ON BRIDGE.
Condition: Unknown
Due 21 March 1994
Resolved 7 September 1994
Engineering
Issued 11 March 1993 Resolved
GUARDS MISSING AT BUILT DRIVES AT (2) MAIN ENGINES AND (1) DIESEL GENERATORSET._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 11 March 1993 Resolved
MISSING PROPER LABELING OF BILGE AND FIRE LINES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Engineering
Issued 11 March 1993 Resolved
emergency fuel shutoff valve not labled._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Lifesaving
Issued 11 March 1993 Resolved
MISSING LANYARD TO PROPERLY AFFIX WATERLIGHT TO RING BOUY.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Engineering
Issued 3 April 1989 Resolved
RE-LOCATE "EMERGENCY FUEL SHUT-OFF" SIGN WHERE VISIBLE.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Deck/Cargo
Issued 3 April 1989 Resolved
PROVIDE ONE ANCHOR ACCESSIBLE TO MAIN DECK.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Engineering
Issued 3 April 1989 Resolved
SECURE OIL LEAKS OVER STARBOARD ENGINE.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Fire Fighting
Issued 3 April 1989 Resolved
LABEL FIRE AX WITH VESSEL NAME.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Documentation
Issued 3 April 1989 Resolved
POST EMERGENCY CHECK-OFF LIST ON BULKHEAD ACCESSIBLE TO PASSENGERS AND CREW.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Documentation
Issued 3 April 1989 Resolved
MAKE APPLICATION FOR FCC COMMUNICATIONS ACT RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Engineering
Issued 3 April 1989 Resolved
HARD-WIRE SUBMERSIBLE BILGE PUMP IN ENGINEROOM.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Navigation
Issued 1 November 1988 Resolved
POST VESSEL'S AND OPERATOR'S FCC LICENSES.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.