MAURY USCG vessel records
← All vessels

TIKI QUEEN

TIKI QUEEN is a 1969 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in August 2026, along with 46 deficiencies and 2 casualty investigations in 2020.

Records from 2016 to 2026. Most recent: inspection, 7 August 2026.

Built
1969
Last inspected
7 August 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 August 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5080
301543
Flag
UNITED STATES
Maury page id
psix-301543

Documentation record

Registered dimensions (L × B × D)43.3 ft × 12.3 ft × 3.3 ft
Registered tonnagegross 40 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAKECRAFT WELDING COMPANY · PORT CLINTON, OH, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portSURF CITY, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 46 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

7 August 2026 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8455169
12 March 2025 Deficiency Check · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8092298
10 July 2024 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7954821
5 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7733678
7 February 2023 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7633094
7 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7426256
12 July 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7253287
16 February 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7141102
8 September 2020 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7053524
8 September 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7054964
13 August 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7036214
16 July 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7007514
7 July 2020 Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6999579
18 May 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6955024
12 July 2019 Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6746896
27 November 2018 Internal Structural Exam · Drydock Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6587241
18 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6417529
19 February 2016 Deficiency Check · Administrative Inspection · COI Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Simplified Stability Test
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5819632

Deficiency record · 46

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 August 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Stern light not operational. Vessel is restricted to day time operations only until properly repaired.
Action required: 705 - Other - as specified
Resolved 11 August 2026
Resolution: New stern light installed and operational
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 June 2025 Resolved
The vessel must be provided with a visual and audible alarm at the operating station, which indicates high water level in required spaces. The bilge alarms for the tank room and lazarette are not working.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 June 2025
Resolved 2 June 2025
Resolution: Repaired on the spot
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 June 2025 Resolved
Portable fire extinguishers and fixed fire fighting systems must be serviced annually IAW NFPA rules. Servicing was due 31 MAY 25
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 21 July 2025
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 2 June 2025 Resolved
A vessel must carry a first aid kit with ISO approval or a kit with equivilant contents; the exisiting kit is in need of burn gel, antispetic wipes and bandanges
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 21 July 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2025 Resolved
Remote fuel shutoff valves must be properly marked; valves are not marked
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 21 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 June 2025 Resolved
The marine employer must have a drug testing program in place. The owner could not provide proof of the current contract, list of employees or MIS report.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 21 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 June 2025 Resolved
As appropriate for the intended voyage a vessel must carry adequate navigation publications; the existing light list is out-of-date
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 21 July 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2025 Resolved
Provisions must be made for closing supply ducts and exhaust ducts for spaces protected by a fixed extinguishing system
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 21 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 March 2025 Resolved
A vessel must have navigation lights that are compliant with the inland navigation rules. the anchor light is intermittent and did not work initially.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2025
Resolved 21 July 2025
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 July 2024 Resolved
Any vessel of at least 5 net tons which engages in commercial service must have a certificate of documentation; the operator did not have a current COD on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 15 July 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 July 2024 Resolved
The operator is required to have a drug and alcohol testing program in place in accordance with 46 CFR Part 16; The operator did not have a copy of the current contract, the MIS annual report, and there was no alcohol testing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 22 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2024 Resolved
Water light batteries must be replaced in accordance with manufacturers instructions or upon the battery expiration date; the water light battery is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 15 July 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 July 2024 Resolved
A vessel must carry an approved first aid kit with the proper inventory; the existing kit does not have aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 15 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 July 2023 Resolved
All vessel shall be equipped with a hand operated portable fire/bilge pump having a capacity of 5 GPM IAW 46 CFR 181.10-5; the vessel is not so equipped.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 12 July 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 July 2023 Resolved
Waste receptacles must be constructed of non-combustible materials with no holes in the sides or bottom; the existing trash cans are plastic.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 12 July 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load; the port transmission is inoperable and unable to engage forward or reverse gears.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 July 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 April 2022 Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent content; the existing kit does not have a complete inventory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 21 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2022 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel, its operation, and for the purpose intended; the port shaft is rubbing in the bulkhead penetration causing damage to the shaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 4 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2022 Resolved
The name of the vessel must be marked in clearly legible letter on each piece of lifesaving equipment; numerous life jackets are not marked or marked with the improper vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 21 April 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 July 2021 Resolved
A vessel of at least 26' in length must be provided with a visual and audible alarm, at the operating station, which indicates high water level in required spaces; three bilge alarms are not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2021
Resolution: New float switches were installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 July 2021 Resolved
A vessel must be fitted with navigation lights that are in compliance with the inland navigation rules; the anchor light is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2020 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load; the starboard transmission is presently not operational and requires repair or replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2020 Resolved
A vessel on a rivers route must carry three red and three orange distress signals; the red flares are expired and the orange smoke signals will expire next month.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
Resolution: corrected
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 May 2020 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water levels in the bilges; the visual alarm for the lazarette and the audible alarm for the engine compartment are not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 May 2020 Resolved
Provisions shall be made by way of covers to prevent the admission of air to a space that is protected by a fixed fire fighting system; the vent covers for the engine compartment are corroded and will not fit into the vent closures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 May 2020 Resolved
A marine employer must have a drug and alcohol program in place and ensure that all crew members are enrolled in the program; the existing program is expired, there is no list of crew members enrolled, and there is no proof of the Management Information System (MIS) report for calander year 2019.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 May 2020 Resolved
A vessel shall carry on board a means to conduct alcohol testing in the event of a serious marine casualty; the existing test strips are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2020 Resolved
A vessel must carry a floating waterlight; the existing waterlight is not operational, the vessel is restricted to daylight operations only.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2020 Resolved
The name of the vessel must be marked in clearly legible letters on each life jacket; numerous life jackets are marked with the improper vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 May 2020 Resolved
A vessel must be equipped with a sound signal which emitts a signal with an intensity which can be heard at .5 miles; the existing horn is not emitting a signal of adequate intensity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020 Resolved
Electrical installations shall be such that they don not present an electrical or safety hazard to personnel; the wire run from the port engine for the RPM gauge is hanging loose and disconnected in the engine compartment bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2019 Resolved
Main propulsion engines shall be designed and serviceable for marine systems. After replacing both shafts and couplings there is significant interference at the coupling bolts and reduction gear housing and where the shafts penetrate the machinery space bulkhead. Submit repair proposal to correct both issues.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2019
Resolution: Repairs complete, sea trials conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2019 Resolved
VSL shall be provided with a type I PFD for each person authorized on the COI. Condemned 7 adult life jackets. Passenger count reduced to 42. Ensure replacement jackets are Type I with VSL name and reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2019
Resolution: Additional jackets have been placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2019 Resolved
Fire extinguishers shall be provided with an approved bracket. The fire extinguisher by the head is not serviceable. Provide a new bracket (marine style) as designate4d by the extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2019
Resolution: New brackets have been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2019 Resolved
Main propulsion engine shall be designed and serviceable. The STBD reduction gear seal is pulling out of the housing. RE-insert seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2019
Resolution: Seal has been reinserted and is holding oil properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2019 Resolved
The alignment of both propulsion engines is causing accelerated wear in the prop shaft keyways. Provide written repair proposal to OCMI for review and approval by 17JUL19.
Action required: 705 - Other - as specified
Resolved 12 August 2019
Resolution: Deficiency cleared and another issued.
Engineering › Bilge Water Management System › Pump
Issued 18 May 2018 Resolved
Replace all 4 switches for bilge pump controls. Prior to carrying passengers prove proper operation to Coast Guard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2018
Resolution: O/O provided photographs and a statement that all switches have been replaced and tested and are operating properly.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 May 2018 Resolved
Have all portable fire extinguishers & installed halon serviced by approved third party.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 11 June 2018
Resolution: Reviewed third party servicing report for fire extinguishers which included the installed halon system.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2018 Resolved
Replace 2 condemned adult type I PFD's. Ensure jackets ae marked and have approved reflective tape.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 11 June 2018
Resolution: Two new type I pfd have been placed onboard and properly marked.
Engineering › Bilge Water Management System › Strainer
Issued 18 May 2018 Resolved
Vacuum all granular oil absorbent from engine room.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 11 June 2018
Resolution: Engine Room bilge was free of debris. Advised O/O not to use granular absorbant any longer and if needed to use a "oil sock".
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 May 2018 Resolved
Provide updated tide tables and local notice to mariners.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 11 June 2018
Resolution: Updated tide and current tables and light list were verified onboard.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 18 May 2018 Resolved
Properly install pipe bracket on port engine.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 11 June 2018
Resolution: Bracket has been properly installed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 May 2018 Resolved
Establish drill and training log.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 11 June 2018
Resolution: A new drill and training log was provided onboard.
Lifesaving › Hand Flares › Storage
Issued 26 April 2016 Resolved
Provide waterproof box and mark "Distress Signals" for stowage of flares.
Due 26 May 2017
Resolved 15 June 2017
Resolution: Received acceptable photographs to clear deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 April 2016 Resolved
Provide first aid kit waterproof box and contents as provided on inventory sheet.
Due 26 May 2017
Resolved 15 June 2017
Resolution: Received acceptable photographs to clear deficiency.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 April 2016 Resolved
Provide two (2) in date alcohol test strips.
Due 26 May 2017
Resolved 15 June 2017
Resolution: Received acceptable photographs to clear deficiency.

Casualty record · 2

13 August 2020Routine · role: Involved in a Marine Casualty · activity 7036214
8 September 2020Routine · role: Involved in a Marine Casualty · activity 7054964
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.