Records from 2006 to 2026. Most recent: inspection, 4 May 2026.
Inspection history · 37
4 May 2026
Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8367079
26 September 2025
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8241717
16 June 2025
Administrative Inspection · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8160046
24 February 2025
Plan Review (Other than "T")
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8113528
15 October 2024
Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8019048
16 August 2024
In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7989301
28 July 2024
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7972050
26 July 2024
Type not recorded
No type recorded · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7971537
24 June 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7931544
14 November 2023
Drydock Extension · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7824799
14 November 2023
Plan Review (Other than "T")
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7885706
14 August 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7791259
25 July 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7765100
17 July 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7740509
27 May 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7697468
24 May 2023
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7704381
22 May 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7694124
10 April 2023
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7665593
28 October 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7585316
22 September 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7583297
19 May 2022
Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7473594
6 May 2022
COI Inspection · In-Service Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7431604
15 February 2022
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7399669
30 September 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7322858
20 May 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7199277
20 July 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7007998
20 June 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6719286
16 May 2019
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6684630
12 April 2019
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6669649
10 January 2019
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6608552
1 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6572655
26 July 2018
In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6490571
29 March 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6113601
28 February 2017
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6096581
22 June 2016
DAPI Audit · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5916288
15 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5908404
17 May 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5879788
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2026
Resolved
(a) One length of fire hose shall be provided for each fire hydrant required.
Fire hose on main deck was found with two holes leaking water once energized. Replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2026
Resolved 7 May 2026
Resolution: New hose installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 May 2026
Resolved
(a) At each initial and subsequent inspection for certification, reinspection and at every other vessel inspection the marine inspector shall require that all
observed unsafe practices and hazardous situations be corrected.
Both generators on vessel have an excess buildup of oil inside exhaust fan vents. Oils needs to be cleaned up and identify where the oil is coming from. Once identified, repairs need to be completed to prevent buildup of oil.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 22 June 2026
Resolution: Both gens cleaned, no evidence of leaking oil
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2026
Resolved
(b) Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
Port Main propulsion engine temperature gauge is not operational at the operating station. Replace in kind. Until repairs are made, engine room rounds need to be completed to ensure engine is not overheating.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 24 June 2026
Resolution: Vessel crew repired gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2026
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
Throttle on port main propulsion engine has a retaining clip that rattles off when engine is running. To prevent loss of propulsion, retention clip needs to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 1 July 2026
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
To prevent future loss of ships electrical power while underway, positive terminal on port generator starter needs to be tightened.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 4 May 2026
Resolution: Vessel crew tighteded terminals.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2026
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
Second deck bar area needs to be cleaned.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2026
Resolved 24 June 2026
Resolution: Vessel crew cleaned concession area.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2026
Resolved
(c) Each fire hydrant must have a valve installed to allow
the firehose to be removed while the fire main is under
pressure.
Testing second deck fire hose forward, valve was found to be leaking. Valve replaced in kind prior to MI departure. All sat.
Action required: 10 - Deficiency Rectified
Due 4 May 2026
Resolved 4 May 2026
Resolution: New valve installed. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2026
Resolved
(c) L. The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage.
Pressure gauge was found non-operational, vessel rep replaced in kind prior to MI departure. All sat.
Action required: 10 - Deficiency Rectified
Due 4 May 2026
Resolved 4 May 2026
Resolution: New gauge installed, all sat.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 26 September 2025
Resolved
(b) On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members.
Public address system is not working on the main deck interior. Passengers are not permitted in the interior main deck space until the public address system is corrected.
Action required: 705 - Other - as specified
Due 10 October 2025
Resolved 14 October 2025
Resolution: Unit was not properly turned on. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 September 2025
Resolved
(b) At each inspection for certification and at every other
vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
Engine room bilge has oil soaked oil absorbents under each engine, oil on top of both MDE blocks, and oil buildup on starboard engine air intake. Oil within the space needs to be cleaned up and new oil absorbents placed where needed and changed daily or more often as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 14 October 2025
Resolution: Engine room has been cleaned
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 September 2025
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
Build up of debris on engine room exhaust piping on starboard engine needs to be cleaned to reduce fire hazard potential.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 14 October 2025
Resolution: Engine room has been cleaned
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 September 2025
Resolved
(a) At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
Electrical outlets faceplates are broken behind main deck bar and second deck bar need new replaced. The electrical panel on the main deck has an open space, need to install blank or a breaker to prevent electrical shock. Extension cords are being used behind the second deck bar and and refrigerator/microwave. If additional outlets are needed install new outlets once approved.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 8 January 2026
Resolution: Received attestation from vessel rep of correction. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 September 2025
Resolved
(b) Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
Multiple gauges at operating station not functioning properly. New gauges need to be installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 8 January 2026
Resolution: Received attestation from vessel rep of correction. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 September 2025
Resolved
(c) A voltmeter and an ammeter, which can be used for
measuring voltage and current of a generator that is in
operation, must be provided for a generator rated at 50
volts or more. For each alternating current generator, a
means for measuring frequency must also be provided.
Generator hertz gauge and ampres gauge are not working properly, install new gauages in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 8 January 2026
Resolution: Received attestation from vessel rep of correction. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 September 2025
Resolved
An exposed hazard, such as gears or rotating machinery,
must be protected by a cover, guard, or rail.
Guard missing on starboard main diesel engine around fan belt to alternator. Install guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2025
Resolved 14 October 2025
Resolution: Guard was reinstalled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 September 2025
Resolved
(b) At each inspection for certification and at every other
vessel inspection the bilges and other spaces may be
examined to see that there is no excessive accumulation
of oil, trash, debris, or other matter that might create a
fire hazard, clog bilge pumping systems, or block
emergency escapes.
Starboard main diesel engine was leaking oil one drip approx. every 5 seconds due to a loose bolt behind the oil filter. Mechanic tightened bolt before MI departure, all sat.
Action required: 10 - Deficiency Rectified
Due 26 September 2025
Resolved 26 September 2025
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2025
Resolved
(a) On a vessel of at least 7.9 meters (26 feet) in length,
a visual and audible alarm must be provided at the operating station to indicate a high water.
Missing visual (light) high level alarm for tank room at operating station. Replace indicating light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2025
Resolved 30 June 2025
Resolution: New bilge alarm installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2025
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
Missing guard on Port Main Diesel Engine (MDE), remount guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2025
Resolved 30 June 2025
Resolution: Guard re-installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2025
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire
hazards, and other hazardous situations must be
corrected and all required guards and protective devices
must be in satisfactory condition.
Exposed electrical around refer space on stern needs to be in an electrical box to prevent electrocution.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2025
Resolved 30 June 2025
Resolution: Exposed electrical rewired and placed into junction box. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2025
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
CO2 bottle under main deck bar area needs to be properly secured for sea.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2025
Resolved 30 June 2025
Resolution: CO2 bottle is properly secured for sea. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 June 2025
Resolved
(b) At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
Engine room needs to be organized. Tools, rags, gear, etc are not stowed properly in engine room. A metal storage cabinet should be added for stowage of gear to prevent gear/tools from clogging bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2025
Resolved 30 June 2025
Resolution: Engine room is cleaned up and a rag bin installed. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2024
Resolved
(a) Propulsion machinery must be suitable in type and
design for propulsion requirements of the hull in which
it is installed and capable of operating at constant marine
load under such requirements without exceeding its
designed limitations.
Starboard engine overheated, resulting in engine failure. Engine must be repaired or replaced in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2024
Resolved 2 August 2024
Resolution: Rebuild complete. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2024
Resolved
(g) Nonconducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard.
Main distribution panel and switchboard panel missing nonconductive mat to protect crew from electrical shock. Install nonconductive matting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 15 July 2024
Resolution: Received email from vessel rep with picture showing corrected deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 June 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
First aid kit does not meet new requirements. Purchase appropriate items to update first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 16 June 2025
Resolution: New first aid meeting regulation
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 June 2024
Resolved
Two distress flares are expired, replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 2 August 2024
Resolution: New flares placed into service
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 June 2024
Resolved
(b) Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
Starboard MDE oil pressure gauge not working properly at operating station. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 15 July 2024
Resolution: Received email from vessel rep showing corrected deficiency.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 July 2023
Resolved
Found bilge alarms for the tank room and the lazerette not working when tested. Repair bilge high water alarms to have sound and visual alarms activate at the operating station.
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each normally unmanned spaces.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 July 2023
Resolved 17 July 2023
Resolution: MI received email from vessel rep stating that both bilge high water alarms are repaired and operate properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2023
Resolved
Found portable electrical cords coupled together at the operating station plugged in on the stbd side and ran to the port side.
Portable cords should be used only for connection of portable lamps and appliances and other equipment not suitable for fixed wiring. IEEEStd 45-2002; 24.6.1.
Install permenant cable and recepticle and remove portable electrical cords for permenant equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 14 August 2023
Resolution: Crew installed permanent electrical outlet on the port side of the operating station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2023
Resolved
Main deck and 02 deck concession area had CO2 bottles not secured from tipping.
In accordance with industry safety standards, CO2 bottles should be secured from to prevent from falling or being knocked over by securing them to a fixed object by use of a restraint such as a chain, strap, or bracket.
Secure CO2 bottles from the possibility of tipping or falling.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 10 August 2023
Resolution: Vessel rep procured bottle brackets with straps and installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2023
Resolved
Outlets next to sinks are not protected from splashing water in the 02 deck concessions and the main deck concessions.
Electrical equipment used in a location normally exposed to splashing water or wet conditions must be drip proof.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 14 August 2023
Resolution: Crew installed splash guards or GFCI outlets
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2023
Resolved
02 deck concession was found to have old food about the deck and general dirt and debris throughout the deck.
At every other vessel inspection,toilets and washing spaces, serving pantries, and similar spaces may be examined to determine that they are serviceable and in sanitary condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 14 August 2023
Resolution: Crew cleaned concession area deck
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 July 2023
Resolved
Found excessive oily-water and debris in the engine room bilge.
At every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 10 August 2023
Resolution: Crew pumped out excessive oily/water from bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 May 2023
Resolved
(b) Gages to indicate cooling water discharge temperature and lubricating, oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. When engine is freshwater cooled and exhaust pipe is cooled by a separate water, cooling system, a suitable warning, visible or audible at the operating station, shall be provided to indicate any failure of water flow in the exhaust system.
Vessel currently does not have a working cooling water discharge gauge in view of the operator. Vessel shall maintain a manned watch in the engine room to monitor Starboard engine (main propulsion) until gauge is repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2023
Resolution: Gauge has been repaired. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 May 2021
Resolved
All the weather-tight door seals on the main deck and 01 deck were found to be deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 25 May 2021
Resolution: Crew installed new weather stripping around door frames.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 20 May 2021
Resolved
Rudder angle indicator is showing 5 degrees off to stbd at amidship helm/rudder.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2021
Resolved 25 May 2021
Resolution: Crew adjusted rudder angle indicator arm in lazerette.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2021
Resolved
Found two deck lights missing globe lens on the main deck forward exterior.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2021
Resolved 18 August 2021
Resolution: Received text with pictures from vessel representative showing the new globes installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2020
Resolved
Portable fire extinguishers are not being checked on a monthly basis as per NFPA.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 7 August 2020
Resolution: Crew started to conduct monthly maintenance on portable fir extinguishers.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 July 2020
Resolved
Renew expired contents and ensure all contents of first aid kit are available as per 160.041.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 7 August 2020
Resolution: Rep purchased new first aid kits.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 July 2020
Resolved
Coast pilot and light list were not available on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2020
Resolved 7 August 2020
Resolution: Updated nav publications were placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2020
Resolved
Port engine exahust leak in mechanical room. Found exhaust lagging with soot at seems and traces of exhaust in space when engine started.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2021
Resolved 20 May 2021
Resolution: No exhaust leak could be found.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 July 2020
Resolved
Fire station #1 valve on main deck was found spraying from bonnet. Crew was able to tighten the bonnet but a drip still persists. Replace valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2020
Resolved 7 August 2020
Resolution: Crew replaced valve.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 April 2019
Resolved
Damage to the port propeller, port strut was torn away from the hull hanging on the port shaft by the bearing tube, and port rudder was missing leaving only the upper section of the rudder shaft through the hull.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 14 June 2019
Resolved 23 May 2019
Resolution: Port propeller, port rudder and port strut have been repaired in dry-dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2018
Resolved
Found one battery terminal loose on one stbd side battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2018
Resolved 26 July 2018
Resolution: Vessel maintenance personnel tried to tighten battery terminal with negative results. Battery terminal was replaced during inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2016
Resolved
Renew floating waterlight. Vessel restricted to daylight operations until light is replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 15 June 2016
Resolution: A new waterlight is installed onboard.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 23 May 2016
Resolved
Replace starboard running light bulb. Vessel restricted to daylight operations until new bulb is installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 15 June 2016
Resolution: New bulb is installed and light is operating properly.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 May 2016
Resolved
Stencil ring lifebuoy with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 15 June 2016
Resolution: Lifebuoy has been stenciled.