BURNING DAYLIGHT

BURNING DAYLIGHT is a 1988 passenger vessel (uninspected). The Coast Guard has recorded 4 inspections since 2016, most recently in June 2019, along with 14 deficiencies and 1 casualty investigation in 2019.

Records from 2016 to 2019. Most recent: inspection, 24 June 2019.

Built
1988
Last inspected
24 June 2019
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2019
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF8719
301675
Flag
UNITED STATES
Maury page id
psix-301675

Documentation record

Registered dimensions (L × B × D)50.0 ft × 15.7 ft × 7.7 ft
Registered tonnagegross 40 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSITKA, AK
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 8 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

24 June 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6751115
22 May 2018 Uninspected Passenger Vessel
Physical examination · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 6482499
9 June 2017 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6170838
17 August 2016 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5975393

Deficiency record · 14

Lifesaving › Inflatable Liferafts › Servicing
Issued 17 August 2016 Resolved
Send out vessel lifraft for servicing which was overdue for last two months. Vessel is restricted in carrying revenue passengers until liferaft is onboard to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 17 August 2016 Resolved
Properly service fixed CO2 system by a qualified servicing company to the satisfaction of an attending Marine Inspector. Last date service tag: 5/17.2014 by Sitka.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Communications › Public Address System › Amplifier
Issued 17 August 2016 Resolved
Demonstrate proper operation of the vessel public address system after the new amplifier is installed to the satisfaction of an attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 August 2016 Resolved
Renew vessel EPIRB expired battery, hydro-static released, & NOAA Registration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Communications › Visual Communication › Red Warning Signal
Issued 17 August 2016 Resolved
Provide additonal (3) - each missing red signals flares & hand held orange smoke signals.
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 August 2016 Resolved
Modify deck rails to comply as per 46 CFR 177.900. Rail courses, bar slats, or equivalent like chain link fencing, wire mesh that has openings of no more than (4) inches. Rail courses spacing at intervals of not more than 4 inches (100 millimeters).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 August 2016 Resolved
Complete the vessel first aid kit as per Table 46 CFR 160.041-4(b), items for First Aid Kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 August 2016 Resolved
Properly stow dead end wires located overhead in a way of STBD side bridge control area.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Fire Fighting › Fire Bucket › Quantity
Issued 17 August 2016 Resolved
Provide missing two - 2 1/2 gallon fire buckets & label "FIRE BUCKETS" with tending line long enough to reach water on the vessel side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Documentation › Logs/Records › Logbook (official)
Issued 17 August 2016 Resolved
Provide a vessel logbook & maintained documentation as per 46 CFR 185. Recommended logging like drills, equipment maintenance, machinery or navigation casualties, voyages & number of passengers onboard, or any particular events related to vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Operations/Management › Drills/Instruction › Fire
Issued 17 August 2016 Resolved
Perform emergency drills (Fire, Abandon Ship, & Man-overboard) & demonstrate safety orientation to the satisfaction of an attending Marine Inspector prior to carrying revenue passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Fire Fighting › Means of Escape › Blocked
Issued 17 August 2016 Resolved
Make the emergency exit hatch forward compartment bow area operational to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Construction/Loadline › Structures › Scuttle
Issued 17 August 2016 Resolved
Install the missing tending line for the aft hatch for the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 17 August 2016 Resolved
Restore the exhaust pipe for the onboard diesel fired cooking stove to original height as per approved plans.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 9 June 2017
Resolution: COI Surrendered.

Casualty record · 1

24 June 2019Routine · role: Involved in a Marine Casualty · activity 6751115
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.